supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

Similar documents
BumbleBee. High Voltage Differential Probe Ord.-No: Features:

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

As all PMK probes the PML 751-RO features CeramCore TM technology. The entire probe

PML 711A-RO High impedance passive probe Features:

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

PML 791-RO. High impedance passive probe. Features: 2.5 mm Diameter Tip. Coaxial Design. Interchangeable Spring Contact Tip

PKT 512A-RO High Impedance Passive Cable Divider

PHV RO High Voltage Passive Probe. Instruction Manual

TK 100 Probe Calibrator. Instruction Manual

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual

TETRIS User's Guide. High Impedance Active Probe DO177-1

400 MHz Passive High-Voltage Probe R&S RT-ZH


TA MHz oscilloscope probe TA MHz oscilloscope probe

TT-SI MHz Active Differential Probe

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TT-SI MHz DIFFERENTIAL PROBE

TT-SI 9001 / TT-SI MHz Active Differential Probes

TT-SI MHz Active Differential Probe

9 Specifications. Specifications NOMINAL CHARACTERISTICS

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

DC MHZ PXI Differential Instrumentation Amplifier

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

Operator s Manual. PP022 Passive Probe

Operator s Manual. PP016 Passive Probe

Current clamps for AC current

MD 200A High voltage differential probe

USER MANUAL. Ultra-Low Noise High Voltage Amplifier WMA V to +150V output. 300µV rms output noise. 2mV output offset voltage

7051Plus / 5051Plus. Extended Specification

Operator s Manual. PP017 and PP018 Passive Probes

Oscilloscope Probes and Accessories

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

NI SCXI Specifications

Quick Start RSDPB5000/RSDPB4000. High Voltage Differential Probe Series

Wide-band Models from DC to 100 MHz

E Series 9.00 (1/2) E series

NI PXI-2520 Specifications 80-Channel SPST Relay Module

Pre-Amplifier SPA Series

USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical

Wide-band Models from DC to 100 MHz

8558A 8 1/2 Digit Multimeter

DS 6000 Specifications

Series OLH10KD 10kW HIGH VOLTAGE POWER SUPPLIES

NI PXI-2521 Specifications 40-Channel DPST Relay Module

Wide-band Models from DC to 100 MHz

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

Documentation. PerfectPulse Fast Edge Signal Generator

High Voltage Differential Probes HVD3605, HVD3206 HVD310x

Fluke 5820A Oscilloscope Calibrator Specifications

SA1500X. Operating Basics. Cautions DEVICE SPECIFICATIONS. High Impedance Active Probe

Digital Clamp Meter Model: &

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

NI USB Contents DEVICE SPECIFICATIONS. 50 MS/s Bus-Powered USB Oscilloscope

USER MANUAL. DC 13kHz High Voltage Amplifier WMA V to +175V output. Stable with all capacitive loads, generates no overshoot

Series OLS10KD 10kW HIGH VOLTAGE POWER SUPPLY

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

High Voltage Differential Probes HVD3605A, HVD3206A HVD310xA

Appendix A: Specifications

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

AC/DC Current Probe TCP0150 Datasheet

N2790A Differential Voltage Probe

User s Manual Current Probe IM E. 8th Edition

Low Noise Variable Gain Low Frequency Voltage Amplifier

PRELIMINARY DATA. Fiber Optic Isolated Voltage Probe. GE50 Gate Explorer FEATURES

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Analog Characteristics

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

N2792A and N2793A Differential Probes User s Guide

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators

8588A Reference Multimeter

Keysight N2790A Differential Voltage Probe. User Guide

DECLARATION OF CONFORMITY

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

World-Class Accuracy & Measurement Range (40 Conventional Models)

INSTRUCTION MANUAL CLAMP ON PROBE

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

Pulse Amplifier DIV 20 Instruction Manual 03/2016

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

AP034-OM-E Rev D ISSUED: January 2000 ²

DataSheet SIGLENT Series Probe

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

User s Manual Current Probe IM E. 6th Edition

AC/DC Current Measurement Systems

N2790A 100 MHz, N2791A 25 MHz and N2891A 70 MHz High-voltage Differential Probes

User s Manual Current Probe. IM E 2nd Edition IM E

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Transcription:

High Voltage Differential Probe Order-No: 880-102-501 Features: 1000 V CAT III 400 MHz Bandwidth < 1 % Deviation within Specified Operating Temperatures (0 C to +50 C) High CMRR 4 Mode Attenuation Useable with any 50 Ω Measuring Instrument BumbleBee is a 400 MHz, 1 kv CAT III high-voltage, differential probe that can be used with any oscilloscope or device providing 50 Ω termination. The probe is very effective in power device evaluation such as measurements in IGBT circuits used in design of motor drives, switching power supplies and frequency converters. BumbleBee is also very effective in fast transient measurements with bandwidths up to 400 MHz. It provides a 4 Mode Attenuation which allows higher resolution measurements. The probe provides overload indicators for each input channel as well as for the output. That makes it easy to observe, that the differential probe is working in the specified range. The probe also provides an active offset correction in a range of ±4 V, related to the output voltage, with a resolution of 15 Bit. The newly designed input leads are less sensitive to changes of position or twisting. Utilizing lowest ppm components available, the probe offers exceptional stability. Especially long term measurements profit from such low drifts at varying temperatures. Another feature is the probe channel identifier, providing a channel indicator LED.

This datasheet supersedes all previously published material. Specifications that are not marked as guaranteed are published as general information to the user. The specifications stated are achieved with a PMK Power Supply and can vary, if BumbleBee is powered by another source. The instrument should have warmed up for at least 20 minutes and the environmental conditions must not exceed the specified limits of the probe. We recommend a calibration period of 1 year or less. Note that specifications are subject to change without notice. Electrical Specifications (1) Attenuation Ratio (switchable) 50:1 100:1 250:1 500:1 Bandwidth (-3dB) Input Voltage 50 V 300 MHz 300 MHz 400 MHz 400 MHz Input Voltage 500 V n.a n.a 300 MHz 300 MHz Input Voltage 1000 V n.a n.a n.a 300 MHz Risetime (10 %- 90%) Input Voltage 50 V 1.2 ns 1.2 ns 875 ps 875 ps Input Voltage 500 V n.a n.a 1.2 ns 1.2 ns Input Voltage 1000 V n.a n.a n.a 1.2 ns Typical Noise (rms) (2) 55 mv 55 mv 75 mv 75 mv (referred to input) Typical Propagation Delay 10 ns Max. Input Voltage Measurement Category I Measurement Category III Pollution Degree 2 2000 V rms 6000 V transiente Overvoltage 1000 V CAT III Max. Differential Input Voltage ±200 V DC ± 400 V DC ± 1000 V DC ±2000 V DC (incl. AC peak) Common Mode Voltage ± 2000 V pk (± 1400 V rms) DC Gain Accuracy ± 0.7 % ± 0.7 % ± 0.35 % ± 0.35 % Offset Range (3) ± 4 V Offset Resolution (3) 15 Bit / minimum Step < 125 µv Offset Drift (3) 150 µv / C 150 µv / C 40 µv / C 40 µv / C Input Impedance Each Input to Ground Differential Input Impedance Input Coupling of the Measuring Instrument (4) 5 MΩ 4 pf 10 MΩ 2 pf 50 Ω Typical CMRR DC > 80 db 100 khz > 70 db 1 MHz > 62 db 3.2 MHz > 50 db 2

Voltage Derating Typical Voltage Derating BumbleBee Note that the max. input voltage rating of the probe decreases as the frequency of the applied signal increases. Amplitude AC rms [V] Sinus Amplitude AC rms [V]sinus 2000 1600 1200 800 400 0 100K 1M 10M 100M 1G Frequency [Hz] Input Impedance Typical Input Impedance BumbleBee 100M 10M Note that the input impedance of the probe decreases as the frequency of the applied signal increases. Z [Ohm] 1M 100K 10K 1K 100 10 10 100 1K 10K 100K 1M 10M 100M 1G Frequency [Hz] 3

Power Supply Model Description Order Number PS-02 2 Channel Power Supply 889-09V-PS2 PS-03 4 Channel Power Supply 889-09V-PS3 Mechanical Specifications Weight (Probe only) Cable Length Input Leads Length Input Connectors Output Connector 370 g 2 m 25 cm 2 x 4 mm (male) BNC (male) Environmental Specifications operating non- operating Altitude up to 2000 m up to 15000 m Temperature Range Probe Assembly 0 C to +50 C -20 C to +70 C Input Leads only -40 C to +85 C Maximum Relative Humidity 80 % RH for temperatures of up to +31 C, decreasing linearly to 40 % at +50 C. Keyboard Layout - BumbleBee (1) Measured at + 23 C environment connected to PS-02 Power Supply (2) Broadband Noise, Bandwidth 30 MHz (3) Referred to Output (4) Must be met to achieve best Performance and avoid Damage to the Probe 4

WEEE/ RoHS Directives PMK electronic products are classified within the WEEE/ RoHS* category list as monitoring and control equipment (category 9). Category 9 products are exempt from the restrictions under the scope of the RoHS directive. Your help and efforts are required to protect and keep clean our environment. Therefore return this electronic product at the end of its life either to the Service Department of PMK Mess- und Kommunikationstechnik GmbH or take care of separate WEEE collection and professional WEEE treatment yourself. Do not dispose as unsorted municipal waste. * EC Directives: WEEE Directive 2002/96/EC Waste Electrical and Electronic Equipment RoHS Directive 2002/95/EC Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment Safety Information To avoid personal injury and to prevent fire or damage to this product or products connected to it, review and comply with the safety informations stated in the manual before using this product. Be aware that if you use this probe assembly in a manner not specified the protection this product provides may be impaired. Only Qualified Personnel should use this Probe Assembly. Manufacturer PMK Mess- und Kommunikationstechnik GmbH Königsteiner Str. 98 65812 Bad Soden am Taunus, Germany Internet: www.pmk.de Tel: +49 (0) 6196 5927-930 E-Mail: sales@pmk.de Fax: +49 (0) 6196 5927-939 Revision H March 2015 5