Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

PML 711A-RO High impedance passive probe Features:

PML 791-RO. High impedance passive probe. Features: 2.5 mm Diameter Tip. Coaxial Design. Interchangeable Spring Contact Tip

As all PMK probes the PML 751-RO features CeramCore TM technology. The entire probe

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

PHV RO High Voltage Passive Probe. Instruction Manual

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

400 MHz Passive High-Voltage Probe R&S RT-ZH

PKT 512A-RO High Impedance Passive Cable Divider

TETRIS User's Guide. High Impedance Active Probe DO177-1

TETRIS 1000 High Impedance Active Probe. Instruction Manual

TK 100 Probe Calibrator. Instruction Manual

TA MHz oscilloscope probe TA MHz oscilloscope probe

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

Operator s Manual. PP016 Passive Probe

Operator s Manual. PP022 Passive Probe

Operator s Manual. PP017 and PP018 Passive Probes

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

9 Specifications. Specifications NOMINAL CHARACTERISTICS

Appendix A: Specifications

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TT-SI MHz DIFFERENTIAL PROBE

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TT-SI MHz Active Differential Probe

SA1500X. Operating Basics. Cautions DEVICE SPECIFICATIONS. High Impedance Active Probe

TT-SI 9001 / TT-SI MHz Active Differential Probes

TT-SI MHz Active Differential Probe

SCXI MHz Quad 8x1 50 Ω Multiplexer

NI SCXI Specifications

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:


INSTRUCTIONS MODELS AVX-TFR-MELF TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER:

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

INSTRUCTIONS MODELS AVX-TRR-SQMELF TEST JIG FOR USE WITH AVTECH AVR-EB4-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

Passive High Voltage Probes P5100 P5102 P5120 P6015A

Passive High Voltage Probes P5100A-TPP0850-P5122-P5150-P6015A Datasheet

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

NI PXI-2520 Specifications 80-Channel SPST Relay Module

USER MANUAL. DC 13kHz High Voltage Amplifier WMA V to +175V output. Stable with all capacitive loads, generates no overshoot

Oscilloscope Probes and Accessories

BENNING. CM7 Electrical Tester. Service Information

User s Manual Current Probe. IM E 2nd Edition IM E

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

NI PXI-2521 Specifications 40-Channel DPST Relay Module

DM-45 Digital Multimeter

Current clamps for AC current

High Voltage Differential Probes HVD3605, HVD3206 HVD310x

USER MANUAL. Ultra-Low Noise High Voltage Amplifier WMA V to +150V output. 300µV rms output noise. 2mV output offset voltage

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

INSTRUCTIONS MODEL AVX-S1-P2-EX1 PLUG-IN SOCKET OUTPUT MODULE SERIAL NUMBER:

NI PXI-2555 Specifications

Current ON state current ma minimum, 6 ma typical, 10 ma maximum OFF state current ma maximum

2017 Advanced Energy Industries, Inc. HITEK POWER MH60 SERIES VERSATILE HIGH-VOLTAGE POWER SUPPLY MODULES

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

High precision measurement system for current and voltage IHC-A/B-RM01/03

Thin Film Rectangular Chip Resistors

High Voltage Differential Probes HVD3605A, HVD3206A HVD310xA

Flexible AC current probes

INSTRUCTIONS MODELS AVX-CA-SEMA TEST JIG FOR USE WITH AVTECH AVR-EB2A-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Current clamps for AC current

NI PXI-2557 Specifications

MiniFlex MF HF MF HF FLEXIBLE AC CURRENT SENSOR. User Manual. High Frequency Response for Oscilloscopes

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

NI PXIe-5601 Specifications

USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

VERI50 EFT for EFT calibration applicable to all TRA2000 generators and CDN2000 coupling filters

AC/DC Current Probe TCP0150 Datasheet

NI USB Contents DEVICE SPECIFICATIONS. 50 MS/s Bus-Powered USB Oscilloscope

P331-2 set ESD generator (IEC )

Digital Clamp Meter Model: &

BROADBAND'LINEAR'AMPLIFIER Model&F10AD

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

BROADBAND LINEAR AMPLIFIER Model F1020 (models F10A and F20A combined)

Electrical Multimeter

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

Keysight N2771B 30 kv High Voltage Probe

NI PXI/PXIe-2529 Specifications

Series OLS10KD 10kW HIGH VOLTAGE POWER SUPPLY

NI PXI/PXIe-2540 Specifications

Kentech Instruments Ltd. CPS3/S pulser Serial No. J03*****

NI PXI/PXIe-2532 Specifications

Appendix A: Specifications

Choosing the right Pico Technology active differential probe

User s Manual Current Probe IM E. 6th Edition

N2792A and N2793A Differential Probes User s Guide

Model /701913/ PBA1000/2500/1500 Active Probe

Transcription:

High impedance passive probe Features: CeramCore TM hybrid probe Modular construction Coaxial design Interchangeable spring contact tip Certificate of calibration available on request Read-out BNC connector The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments having 1 MΩ input resistance. This probe is recommended for probing applications in service and development environments and is adjustable for low and high frequencies. It is also recommended for transient measurements up to 6 kv such as EMC testing applications. The probe is rated with 1000 V CAT II maximum input voltage and complies with latest safety standards. The DC fine adjustment enables trimming for preferred voltage ranges. Like every PMK passive probe the PHV 1000-RO features CeramCore TM technology. The probe's entire core is made of a high quality ceramic hybrid. Pure coaxial design and laser trimmed resistors ensure highest signal fidelity along the signal path offering high bandwidth and fast risetimes for accurate impulse measurements. All passive probes are equipped with PMKs signature spring loaded, needle sharp tips to support precise and safe measurements minimizing the risk of slipping. Various types of tips are available. Besides the spring contact tip there is also a solid tip available at the users choice. Probe tips are interchangeable and can be replaced easily. Basic probe accessories and replacement tips are provided within the scope of delivery or can be purchased separately. The case option includes additional accessories listed in this datasheet. The probes mechanical construction is modular and therefore spare probe leads are available. See this datasheet and corresponding documents for further details. Thank you for your interest in our product! 1

This datasheet supersedes all previously published material. Specifications that are defined typical are not guaranteed and are published as general information to the user. The instrument should have warmed up for at least 20 minutes and the environmental conditions must not exceed the specified limits of the probe. Note that specifications are subject to change without notice. Electrical specifications Attenuation ratio (1) 100:1 ± 2 % at DC Voltage coefficient 0.0025 % / V (typical) System bandwidth 400 MHz (-3 db) System risetime 900 ps (10 % 90 %) (typical) Maximum rated input voltage (2) Measurement category I: 1000 V rms 4000 V transient overvoltage Measurement category II: 1000 V rms CAT II Pollution Degree 2 Voltage derating Amplitude AC rms [V]sinus 1200 1000 800 600 400 200 Typical voltage derating PHV1000 Measurement category I Note that the max. input voltage rating of the probe decreases as the frequency of the applied signal increases. 0 0,1 1 10 100 1000 Frequency [MHz] (1) Connect to oscilloscope with an input impedance of 1 MΩ ± 1 %. (2) As defined in IEC 61010-031. 2

Maximum pulse ratings For pulse measurements make sure to comply with the ratings as shown on this page. Maximum Pulse Derating PHV1000 Measurement Category I Maximum Peak Pulse Voltage 6000 5500 5000 Duty cycle 4500 10% 4000 25% 3500 50% 3000 2500 2000 1500 1000 10 100 1000 Duration [msec] 3

Electrical Characteristics Input resistance (system) 50 MΩ ± 1 % Input capacitance (system) 7.5 pf (typical) Compensation range 10 pf 50 pf (typical) Input coupling of the measuring instrument 1 MΩ AC / DC Input impedance 100000,00 Typical input impedance PHV1000 10000,00 1000,00 Z [KOhm] 100,00 10,00 1,00 0,10 0,01 1E-05 0,0001 0,001 0,01 0,1 1 10 100 1000 Frequency [MHz] Note that the input impedance of the probe decreases as the frequency of the applied signal increases. Mechanical characteristics Weight (probe only) Cable length Probe tip diameter 67 g 2 m 5 mm 142.8 [5.63"] Ø18.2 [0.72"] Ø5.0 [0.20"] Ø17.8 [0.70"] 76 [2.99"] 3.5 [0.14"] Ø11.0 [0.43"] 4

Environmental specifications Altitude operating up to 2000 m non-operating up to 15000 m Temperature range operating 0 C to +50 C non-operating -40 C to +71 C Maximum relative humidity operating 80 % relative humidity for temperatures up to +31 C, decreasing linearly to 40 % at +50 C Declaration of conformity The manufacturer declares the conformity of his products with the actual required safety standards in accordance with the Low Voltage Directive (LVD) 73/23/EEC and amendment 93/68/EEC: CEI/IEC 61010-031:2002 Safety requirements for electrical equipment for measurement, control and laboratory use. Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test. WEEE/ RoHS directives PMK electronic products are classified within the WEEE/ RoHS* category list as monitoring and control equipment (category 9). Category 9 products are exempt from the restrictions under the scope of the RoHS directive. Your help and efforts are required to protect and keep clean our environment. Therefore return any electronic product at the end of its life either to the manufacturer or take care of separate WEEE collection and professional WEEE treatment yourself. Do not dispose as unsorted municipal waste! * EC Directives: WEEE Directive 2002/96/EC Waste Electrical and Electronic Equipment RoHS Directive 2002/95/EC Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment 5

Scope of delivery PHV 1000-RO Order-No. 860-622-A02 Probe Ground lead 22 cm Instruction manual Insulating cap 5.0-L Protection cap 5.0-L Solid tip 0.8 mm Spring tip 0.8 mm Sprung hook 5.0-L Adjustment tool T Protection cap 5.0-L Safety information To avoid personal injury and to prevent fire or damage to this product or products connected to it, review and comply with the safety informations stated in the manual before using this product. Be aware that if you use this probe assembly in a manner not specified the protection this product provides may be impaired. Only qualified personnel should use this probe assembly. Manufacturer PMK GmbH Mess- und Kommunikationstechnik Industriestr. 17 63150 Heusenstamm, Germany Phone: +49 (0) 6104 6453 Fax: +49 (0) 6104 6457 Internet: www.pmk.de E-Mail: sales@pmk.de service@pmk.de Revision B September 2007 6