Attachment to Certificate IECEx PTB X

Similar documents
Power supply. Calibration. Surface finishing. Seal. Process connection

OPTIMASS / 300 / 010 Guidelines for the use of Coriolis meters in hazardous areas

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

ATEX Installation Drawings and Instructions

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

Intrinsic Safety Control Drawing

MFC 300 Technical Datasheet

Ex instruction manual. Rotamass Coriolis mass flow meter ATEX. IM 01U10X01-00EN-R_002, 2nd edition,

Fieldbus Isolating Repeater Series 9185/11

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

MFC 400 Technical Datasheet

Safety Instructions Proline Promag 500

MFC 400 Technical Datasheet

TMU. Coriolis Mass Flow Meter. for liquids and gas

Safety Instructions Proline Promass 300

Proline Promass 83, 84

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

MFC 400 Technical Datasheet

Remote I/O. 74 Remote I/O. Remote I/O System

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

MFC 400 Technical Datasheet

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

Coriolis Massflowmeter

ProcessMaster, HygienicMaster FEX300, FEX500

Signal converter for electromagnetic flowmeters

CERTIFICATE OF COMPLIANCE

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

ProcessMaster / HygienicMaster

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

Model 3244MV MultiVariable Temperature Transmitter with Profibus-PA

OPTIWAVE 7300 C Supplementary instructions

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

PROline promag 53 Division 1

Design and applications

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

IECEx Certificate of Conformity Annexe

Analog Universal Module HART for Zone 2 Series 9468/33

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

DPharp Differential Pressure and Pressure Transmitters

Proline Promass 40. Safety Instructions. NEPSI Zone 1, Zone 21

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

IFC 300 Technical Datasheet

SINEAX TI 807 Passive DC signal isolator

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Alphaline Temperature Transmitters

Coriolis Massflowmeter

VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications

MFC 300 Handbook. Signal converter for mass flowmeters. Electronic Revision: ER 3.3.xx (SW.REV. 3.3x)

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

Installation guide 971 SmartRadar LTi

OPTIMASS 1000 Technical Datasheet

Emerson (Appleton Group ATX)

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Certificate of Conformity

R88000 T (including ATEX)

FLOWMETER. Siemens MAG 5000/6000. Overview

Description of equipment

Safety Instructions Nivotester FTC625, FTC325

Isolators A3/1.

IP26 Series Current to Pneumatic Converter

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Installation guide 970, 971 and 973 series SmartRadar

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Coriolis Mass Flow Meter Model TM

IFC 100 Technical Datasheet

Head mounted Temperature Transmitter TF02/TF02-Ex

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

OPTISONIC 7300 Technical Datasheet

Series 1000 and 2000 Transmitters with MVD TM Technology

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

OPTISONIC 3400 Technical Datasheet

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Two-channel safety barriers Series 9002

Lexium integrated drives

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Two-channel safety barriers Series 9002

Safety Instructions Micropilot NMR81, NMR84

Digital Input Output Module for Zone 2 Series 9470/33

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Rosemount 148 Temperature Transmitter

Transcription:

Applicant: Electrical Apparatus: KROHNE Ltd. Measuring converter, type MFC400F Description of equipment The measuring converter, type MFC400F is used as part of a mass flow measuring system to determine display the mass flow rate of flammable non-flammable liquids. The equipment consists of the separately certified components, electronic assembly, type MFC400, measuring converter housing, type MH300, cable gl, type LC-MASS-Ex as well as a mounting bracket with remote junction box. The measuring converter, type MFC400F is designed as associated apparatus may be installed in the hazardous area. The permissible range of the ambient temperature depends on the design of the housing as follows: Aluminium converter housing: T amb = 40 C... + 65 C Stainless steel converter housing: T amb = 40 C... + 60 C Painted versions: T amb = 40 C... + 40 C Electrical data: Auxiliary power (non-intrinsically safe) depending on version U N = 12 24 V DC, +30 % / -10 %, Terminals, PCB power supply (f sht periods -25 %), 12 W X2-A28...A31 (L/L+) internal fuse I N 2 A X2-A23...A26 (N/L-) U m = 253 V X2-A13, A14, A16, A19...A21 (PE) f connection to protective extra low voltage with safe isolation (PELV) U N = 24 V AC/DC, 22 VA/12 W 24 V AC, +10 % / -15 %, 50/60 Hz 24 V DC, +30 % / -25 % internal fuse I N 2 A U m = 253 V f connection to protective extra low voltage with safe isolation (PELV) U N = 100 230 V AC, +10 % / -15 %, 50/60 Hz, 22 VA internal fuse I N 1.6 A Page 1 of 7

Input/output s (non-intrinsically safe) Printed board: Nominal voltage: U N 32 V DC U m = 253 V Basic IO Terminals IO1-A2, B2 Status output, passive I max = 100 ma IO1-A6, B6 Status output, passive I max = 100 ma control input U max = 32 V IO1-A11, B11 Puls output, passive I max = 100 ma IO1-A15, B15, A16 Current output, active/passive HART Modular IO Terminals IO1-A2, B2 Current output, active/passive HART IO1-A11, B11 Status/puls output, active I max = 20 ma Status/puls output, passive I max = 100 ma Modular Carrier + IO Module depending on module (max. 2 modules) Terminals Mod. A: IO2-A11, B11 Current output, active/passive 0(4) 20 ma Mod. B: IO2-A2, B2 Status/puls output, active I max = 20 ma Status/puls output, passive I max = 100 ma Control input active/passive U max = 32 V Control input, active/passive 0(4) 20 ma, U max = 32 V Fieldbus IO Terminals IO1-A2/A11, B2/B11 accding to function Profibus-PA, passive Foundation Fieldbus, passive Nominal voltage 9 V 32 V Profibus DP IO Terminals IO1-A6/B2, A11/B6 IO1-A2, B11 Profibus-DP, active, 12 Mbit/s Termination Modbus IO Terminals IO1-B2, A11, B11 RS 485 Modbus, active Page 2 of 7

Input/output s (intrinsically safe) (depending on PCB IO-function) Printed board: Exi-IO Current output, passive HART communication Ex ib IIC Terminals IO1-A2, B2 Current output, active HART communication Ex ib IIC Terminals IO1-A2, B2 U o = 21 V I o = 90 ma P o = 0.5 W C o 90 nf 110 nf L o 2.0 mh 0.5 mh Puls/Status output Control input, passive Ex ib IIC Terminals IO1-A11, B11 Page 3 of 7

Exi-Option Current output, passive Terminals IO2-A2, B2 Ex ib IIC Current output, active (Terminals IO2-A2, B2 Ex ib IIC U o = 21 V I o = 90 ma P o = 0.5 W C o 90 nf 110 nf L o 2.0 mh 0.5 mh Puls/Status output Control input, passive Ex ib IIC Terminals IO2-A11, B11 Page 4 of 7

Exi-Option 2 Current input, passive Terminals IO2-A2, B2 Ex ib IIC Current input, active Terminals IO2-A2, B2 Ex ib IIC U o = 24.1 V I o = 99 ma P o = 0.6 W C o = 75 nf L o = 0.5 mh Puls/Status output Control input, passive Ex ib IIC Terminals IO2-A11, B11 Page 5 of 7

Fieldbus IO Profibus-PA Foundation Fieldbus Ex ib IIC passive Terminals IO2-A2, B2 IO2-A11, B11 U i = 24 V I i = 380 ma P i = 5.32 W C i = 5 nf L i = 10 µh FISCO-field device accding to EN 60079-27 Driver A (terminals, Ex ib IIC Dubox Connect X5-1...X5-6) I o = 2130 ma P o = 920 mw C o = 500 nf L o = 16 µh 0 when connected infallibly Driver B (terminals, Ex ib IIC Dubox Connect X5-9...X5-14) I o = 1325 ma P o = 530 mw C o = 500 nf L o = 36 µh 0 when connected infallibly Page 6 of 7

Sens (terminals, Ex ib IIC Dubox Connect X3-1 X3-6) I o = 13 ma P o = 39 mw C o = 90 nf L o = 100 mh RTD / DMS- (terminals, Ex ib IIC Dubox Connect X3 7 10) I o = 9 ma P o = 27 mw C o = 310 nf L o = 1 mh The intrinsically safe s are safely electrically isolated from all non-intrinsically safe s up to a peak value of the nominal voltage of 375 V. Special conditions f safe use 1. The flow meters of type series OPTIMASS 1400C, 2400C, 3400C, 6400C, 7400C shall be included in the equipotential bonding system of the hazardous area. 2. Opening the enclosure inside the hazardous area is only permissible in a de-energized state with keeping a subsequent waiting time (warning label!) This waiting time is: 35 minutes f temperature class T6 10 minutes f temperature class T5 No waiting time is required f temperature classes T4... T1. 3. Only certified cable gls may be applied as cable entries. Non-used openings shall be sealed by means of certified blind plugs. 4. The connecting cables shall be installed as fixed wiring in such a way that they are sufficiently protected against damage. Page 7 of 7