Using the Microscope for a NANSLO Remote Web-based Science Lab Activity

Similar documents
Lab format: this lab is delivered through a combination of lab kit (LabPaq) and RWSL

Relationship to theory: This activity involves the motion of bodies under constant velocity.

Zeiss AxioImager.Z2 Brightfield Protocol

Brightfield Microscopy and Image Acquisition on Spotcam1. by Ryan Taylor/Nancy Kleene Last modified 10/02/05 by Birgit Ehmer

MEASUREMENT CAMERA USER GUIDE

Simplified Instructions: Zeiss Brightfield Microscope S1000

User Operation of JEOL 1200 EX II

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING

Basic Microscopy. OBJECTIVES After completing this exercise, you should be able to do the following:

Match the microscope structures given in the left column with the statements in the right column that identify or describe them.

Operating Instructions for Zeiss LSM 510

Zeiss LSM 880 Protocol

Photoshop Elements Hints by Steve Miller

Zeiss LSM 780 Protocol

RENISHAW INVIA RAMAN SPECTROMETER

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 1: THE LIGHT MICROSCOPE

REMEMBER: You have 5GB of disk space on this microscope. Check before you start if you have room for your experiment. If not delete your old data.

MIF ZEISS LSM510 CONFOCAL USER PROTOCOL

Digital Microscope. User Manual

Adobe Photoshop CS5 Tutorial

University Libraries ScanPro 3000 Microfilm Scanner

Leica DMi8A Quick Guide

Adobe Photoshop. Levels

Adobe Photoshop CC 2018 Tutorial

The user should already be familiar with operation of the instrument in STEM mode, use of the Microscope Control interface, and TIA.

X-Mag. High-Magnification Workstation User s Guide Revision A

Chapter 1: Introduction

Installation & User Manual Micro-Image Capture 7

The Main Screen. Viewing Area - show the photos that were selected in the Source List.

TOPAZ LENS EFFECTS QUICK START GUIDE

Photo Editing in Mac and ipad and iphone

GlobiScope Analysis Software for the Globisens QX7 Digital Microscope. Quick Start Guide

HDR Darkroom 2 User Manual

Attaching the chucks to workholding devices/machines

CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE

Fuzzy Image Editor. User Manual

Blend Textures With Photos

Visual Anatomy ansd Physiology Lab Manual Pig Version 2nd Edition Sarikas TEST BANK

Getting Started. with Easy Blue Print

Session 3: Getting to Know Photoshop Elements. Keep in mind that there are many others ways of solving the problems.

Characterization Microscope Nikon LV150

JEOL 6500 User Manual

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

Photoshop CC Editing Images

Dickinson College Department of Geology

CHROMACAL User Guide (v 1.1) User Guide

Guide to Confocal 5. Starting session

MICROSCOPY MICROSCOPE TERMINOLOGY

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

LEO 912 TEM Short Manual. Prepared/copyrighted by RH Berg Danforth Plant Science Center

2809 CAD TRAINING: Part 1 Sketching and Making 3D Parts. Contents

HISTOGRAMS. These notes are a basic introduction to using histograms to guide image capture and image processing.

User Manual. Copyright 2010 Lumos. All rights reserved

User Guide for TWAIN / DirectX interface for GRYPHAX USB 3.0 cameras

Microscopy. Danil Hammoudi.MD

The invention of the microscope made it possible for scientists to view and study cells. Cells the basic units of all living organisms.

OPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE. by Doug Bray Department of Biological Sciences University of Lethbridge

AF Area Mode. Face Priority

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Image Processing Tutorial Basic Concepts

Zeiss Axio Imager.A1 manual

1. Preliminary sample preparation

STRUCTURE OF THE MICROSCOPE

Revosoft Operators Manual

Lab: The Compound Microscope

Nikon E800 Operating Instructions.

Topaz Labs DeNoise 3 Review By Dennis Goulet. The Problem

PHOTOSHOP1 15 / WORKSPACE

The original image. Let s get started! The final result.

Color and More. Color basics

ADOBE PHOTOSHOP CS TUTORIAL

Image Viewing. with ImageScope

Adobe Studio on Adobe Photoshop CS2 Enhance scientific and medical images. 2 Hide the original layer.

Basic Microscopy for Plant Biology

Welcome 1. Precaution

Guide to AmScope SZM Series Dissecting Scope for Sample Imaging with MU Series Camera

Renishaw InVia Raman microscope

CHAPTER1: QUICK START...3 CAMERA INSTALLATION... 3 SOFTWARE AND DRIVER INSTALLATION... 3 START TCAPTURE...4 TCAPTURE PARAMETER SETTINGS... 5 CHAPTER2:

Processing RAW files in ACR Roy Killen, APSEM, EFIAP, GMPSA

AxioVision 4.5 Brightfield Image Capture Procedure

Digitally Removing Uneven Field Illumination

How to use advanced color techniques

Introduction to Simulation of Verilog Designs. 1 Introduction. For Quartus II 13.0

Workflow. Sample Project

GXCapture 8.1 Instruction Manual

Using Photoshop Elements

Photoshop CS2. Step by Step Instructions Using Layers. Adobe. About Layers:

ONYX Deskset HD. Portable Video Magnifier User s Guide. Freedom Scientific, Inc Revision A

Lab: Using a Compound Light Microscope

Care and Use of the Compound Light Microscope

MAKE SURE YOUR SLIDES ARE CLEAN (TOP & BOTTOM) BEFORE LOADING DO NOT LOAD SLIDES DURING SOFTWARE INITIALIZATION

Imaging Features Available in HTML5. it just makes sense

Planmeca Romexis. quick guide. Viewer EN _2

MAKING THE FAN HOUSING

IMPAX 6 DISPLAY TOOL LIST

Figure 3.4 Approximate size of various types of cells. ~10 um. Red Blood Cells = mm 1500 um. Width of penny Pearson Education, Inc.

Operating Procedures for MICROCT1 Nikon XTH 225 ST

Olympus Digital Microscope Camera (DP70) checklist

Copyright 2014 SOTA Imaging. All rights reserved. The CLIOSOFT software includes the following parts copyrighted by other parties:

An Introduction to Layers, Masks and Channels in Photoshop

Transcription:

Using the Microscope for a NANSLO Remote Web-based Science Lab Activity MICROSCOPE RWSL LAB INTERFACE INSTRUCTIONS The Remote Web-based Science Lab (RWSL) microscope is a high quality digital microscope located at the NANSLO Node. Using a web interface as shown below, you can control every function of the microscope just as if you were sitting in front of it. We've provided you with two ways to learn how to use the microscope for a NANSLO lab activity: 1. Read these instructions or print them for review. 2. Watch a short video found at http://www.youtube.com/watch?v=m7w9ssigvdw. NOTE: The conference number in this video tutorial is an example. See Communicating with Your Lab Partners below to determine the toll free number and pin to use for your NANSLO lab activity. NANSLO LAB ACTIVITY INTERFACE The equipment control software shown below is written using the LabVIEW software from National Instruments. The user interface is presented as a LabVIEW control panel which will be referred to as the lab interface for the remainder of the tutorial. Figure 1: Remote Web-based Science Lab (RWSL) Microscope Lab Interface 1 P a g e

COMMUNICATING WITH YOUR LAB PARTNERS As soon as you have accessed this lab interface, call into the toll free conference number shown on the lab interface to communicate with your lab partners and with the Lab Technicians. Use the PIN code noted to join your lab partners. Only one person can be in control of the equipment at any one time so talking together on a conference line helps to coordinate control of the equipment and creates a more collaborative environment for you and your lab partners. GAINING CONTROL OF THE MICROSCOPE Right click anywhere in the grey area of the lab interface and choose Request Control of VI from the dialogue box that appears when multiple students are using the microscope at the same time. After you request control, you may have to wait a short time before you actually receive control and are able to use the features on this lab interface. RELEASING CONTROL OF THE MICROSCOPE Figure 2: Selecting "Request Control of VI" To release control of the microscope so that another student can use it, right click anywhere in the grey area of the lab interface and choose "Release Control of VI" from the dialogue box that appears. Figure 3: Selecting "Release Control of VI" 2 P a g e

MICROSCOPE CONTROLS The Stage Controls allow you to adjust the visual of the specimen that has been placed on the stage of the microscope, select lenses with various magnifications, and select whether or not the condenser lens is in the light beam. Below are more specific instructions on using these controls. When using the arrows on this lab interface, click and hold the arrow until the desired effect is achieved or click and wait to view the result before clicking again. Quick clicks on the arrows may cause the system to lock up. Figure 4: Microscope Controls - Stage, Objective & Condenser Stage Controls: Using the left and right and up and down arrows found to the right of the microscope image in the Stage Control area, moves the microscope stage which holds the specimen. These arrows allow you to precisely control the position of the specimen on the stage. 1. Use the "Right" and "Left" arrows to move the Stage so that you can view the specimen from left to right. 2. Use the "Backward" and "Forward" arrows to move the Stage so that you can view the top, middle or bottom of the specimen. 3. Use the "Up" and "Down" arrows to move the stage closer or farther away from the objective lens to bring a specimen into focus. BE CAREFUL! Don't move the stage too close to the lens. When selecting the button between the "Up" and "Down" arrows, you can toggle between Coarse and Fine focus. When the button is dark green and Coarse/Fine is displayed to the right of the button, the microscope is in Coarse focus. When the button is bright green and Fine is displayed, the microscope is in Fine focus. Typically, you will start with coarse focus which moves the stage in large increments and then use fine focus to complete your final focusing as it moves the stage in smaller increments. There is no difference between the course and fine focus when using the 60X objective 3 P a g e

NOTE: When you click on these arrows, the specimen appears to move in the opposite direction. Since the objective stays fixed, the image moves in the opposite direction of the stage. This is how these controls work on most microscopes so the "feel" of the microscope is preserved over the web. Figure 5: Right/Left & Backward/Forward Stage Controls Figure 6: Up/Down Stage Controls & Coarse/Fine Focus Control Objective: A microscope mounts an objective lens very close to the object to be viewed. Depending on need, different lenses with different power will be used on the microscope. This microscope feature multiple objectives, each with different power, mounted on a rotating turret. The larger the magnification numbers the greater the magnification. For example, if a specimen is viewed through a 40X objective lens, the magnifier in that lens displays the specimen 40 times larger than an equivalent view as seen by the unaided eye. Remember that the ocular or other lenses also add to the magnification. This microscope has five lenses 4X, 10X, 20X, 40X, and 60X. Use the arrows below the objective lens box that indicates the magnification of the current objective lens to move to a higher or lower magnification lens. If you have activated the Picture-in-Picture Preset 2 (see below) you will be able to see the objective lens move when you select a new magnification. Condenser: The condenser controls whether or not the condenser lens is in the light beam. You want to have the condenser OUT for the 4x objective but IN for all the others. 4 P a g e

SELECTING A CASSETTE AND LOADING SLIDES ONTO THE STAGE There are two tabs on the lab interface. When you first access the lab interface, the "Microscope" tab is displayed by default. Click on the Slide Loader tab at the top of the screen to access the controls for the Slide Loader robot. There can be up to four cassettes available on the Slide Loader. These cassettes are used to store slides, and each can hold up to 50 slides. The cassettes available to you are dependent on the lab activity to be completed. Once a cassette has been selected, you will use the drop-down list to select your slides. EXAMPLE OF HOW TO LOAD SLIDES Figure 7: Select the Slide Loader Tab to select a cassette and slides. In this example, we have selected Cassette #1. Using the drop-down menu, we have selected "1: Colored Threads Whole Mount." Then, we selected the "Load" button. A message indicates that the slide is loading. Using the picture-in-picture camera, you can watch this happening. The robotics selects the slide and places it on the microscope stage. 5 P a g e Figure 8: Selecting the slide "1: Colored Threads Whole Mount" from Cassette #1

Notice that when a slide is actually on the microscope (or when it is being loaded or unloaded), the cassette controls are greyed out so you cannot load a second slide until the first is removed. Once the slide is on the microscope stage, it will be listed in the "Current Slide on Stage" box. The only thing that the Slide Loader robot can do is return it to the cassette when the "Return Slide to Cassette" button is selected. Figure 9: "LOADING SLIDE... PLEASE WAIT" is displayed in the "Current Slide on Stage" window Select the "Microscope" tab to perform the NANSLO lab activity. Once you are finished with the slide, select the "Slide Loader" tab and select "Return Slide to Cassette" button. Once the slide is returned to the cassette, the Slide Loader controls are again available to select another slide from the cassette. 6 P a g e

ENHANCING THE MICROSCOPE IMAGE The digital camera mounted on the microscope has a camera control unit that is equipped with a series of image processing functions that enable you to quickly and easily correct imaging problems that arise from low or high contrast, poor focus, insufficient or uneven illumination, sample shading or discoloration and noise. The most common reason for uneven elimination is a light source that does not completely fill the field of view on lower magnifications. The White Balance should be used only if the image appears to be brown or grey and you think you might need to adjust it (although it won't hurt anything to click this button.) A choice of color modes can be selected in the Microscope Image area and are used to display the image in different color palettes in order to highlight certain features. The default setting is "Normal." 7 P a g e Figure 10: Microscope Image Special Effects and Other Image Controls for Camera Here is a description of each option: 1. In the Normal mode, the sample is displayed in its true colors. 2. In the Negative mode, the sample is displayed in a color-inverted form, where red, green, and blue values are converted into their complementary colors. The technique is useful in situations when color inversion can be of benefit in exposing subtle details or in quantitative analysis of samples. 3. In the Blue Black mode, the black portions of a grayscale negative sample are displayed in blue. This mode is often useful to reveal details in samples having a high degree of contrast. The Blue Black filter can aid you in examining a wide spectrum of difficult samples. 4. In the Black & White mode, a grayscale image of the sample is displayed. 5. In the Sepia mode, a brown scale (black and white) image of the sample is displayed. Although typically this filter is of little utility, it can be employed to alter image color characteristics to improve the visualization of sample detail.

6. At times, the sample may have an unacceptable color quality. Use White Balance calibration to remove the color cast. This process is often referred to as white balancing. 7. Auto Exposure is on automatically. You do not need to do anything with Auto Exposure unless you are adjusting the luminance. If you are doing so, you should turn off Auto Exposure by clicking on the button. The green light is now off. Now adjust the luminance. See explanation below. Reference: http://www.microscopyu.com/articles/digitalimaging/dn100/correctingimages.html Auto Exposure is normally turned on, but you can turn it off if you want to play around with the brightness of the light source and not have the microscope camera automatically adjust it. It is usually best, though, to leave it turned on. When you turn off the Auto Exposure, the button turns dark green. Some new controls appear that let you turn the LED off or on, and also adjust the intensity of the light source. The intensity of the light source can be increased or decreased manually with the dial that now appears next to the Objective control when Auto Exposure is turned off. Figure 11: Additional controls available when Auto Exposure is turned off 8 P a g e

CAPTURING AND SAVING A MICROSCOPE IMAGE When the Capture Image button is pressed, a high-resolution image of what is currently in the field of view of the objective is captured. While the image is being captured, the button will be illuminated bright green. The capture is complete when the light turns off. Be patient as this may take several seconds to complete. After the Capture Image light turns off, select the View Captured Image tab on the bottom of this control panel to view the image. Figure 12: Click the capture image button (#1), wait until the green light goes off, and then select the View Captured Image tab (#2) After opening this image through the View Captured Image tab, you will need to take a snapshot of it and save it to your computer. There are several ways to do this, depending on your operating system. Windows: 1. Pressing the two keys ALT and Print Screen simultaneously will copy the active window into your computer clipboard. Then you can past it into a document. 2. Windows 7 and above has a Snipping Tool program under Programs/Accessories which can capture selected areas of the screen. 3. Right click on it and select "Copy" from the menu presented. After right clicking and selecting Copy, just open a document and right click and select Paste. You can either paste it directly into your lab report document or into another one for safe keeping until you use it later. You can 9 P a g e

use drawing tools in your word processing editor to annotate this image so you can show your instructor that you know what you were suppose to be looking for! Figure 13: Right click and select Copy to paste the image into a document MAC: 1. Press these three keys simultaneously -- and Shift and 4. This will change your cursor icon into a little cross. 2. Now, press the spacebar and the icon becomes a camera. Click in the image window you want to take a snapshot of, and it will save the image to a file on your desktop. There are lots of free screenshot utilities you can also use to capture this image. If you are familiar with saving a document to your computer, you also can select Save Image As from the pop-up menu, give the image a name and then select a location on your computer where you want this image to be saved for future use. MICROSCOPE IMAGE VIEW WINDOW The Image View Window displays the real-time video feed from the digital camera looking through the microscope. 10 P a g e

Figure 14: Image View Window PICTURE-IN-PICTURE CONTROLS - CAMERA PRESET POSITIONS AND PAN-TILT-ZOOM CONTROLS When you click on the "Picture-in-Picture" button, it turns bright green. A second real-time video feed from another digital camera appears in the Image View Window. The controls shown in Figure 15 are all operational when the Picture-in-Picture feature is selected. 11 P a g e

Figure 15: Picture-in-Picture Image Controls CAMERA PRESETS There are six camera preset positions. Figure 16: Picture-in-picture Camera Preset 1 and 6 - Displays the microscope, microscope camera, and a camera control unit projecting the sample on the Stage. 12 P a g e

Figure 17: Picture-in-picture Camera Preset 2: Displays a closeup of the objective lens. Figure 18: Picture-in-picture Camera Preset 3 - Displays a closeup of the camera control unit projecting the sample on the Stage. Figure 19: Picture-in-picture Camera Preset 4 - Displays the microscope eye piece and the camera mounted to the microscope. 13 P a g e

Figure 20: Picture-in-picture Camera Preset 5 - Displays the Condenser Lens underneath the Stage that focuses the light on the sample. The Condenser Lens controls the width of the beam. In some instances you will want a tighter beam while in other cases you will want a broader beam to control the image quality. This setting has been optimized for you. PAN, TILT, ZOOM CONTROLS FOR PICTURE-IN-PICTURE For each camera preset view, additional camera options are available. 1. Use the up and down arrows to tilt the camera up or down. 2. Use the right and left arrows to pan right or left. 3. Use the left "Zoom OUT" arrow and right "Zoom IN" arrow to zoom out and in. Figure 21: Picture-in-picture Camera - Example of "Zoom In" capability For more information about NANSLO, visit www.wiche.edu/nanslo. 14 P a g e

All material produced subject to: Creative Commons Attribution 3.0 United States License 3 This product was funded by a grant awarded by the U.S. Department of Labor s Employment and Training Administration. The product was created by the grantee and does not necessarily reflect the official position of the U.S. Department of Labor. The Department of Labor makes no guarantees, warranties, or assurances of any kind, express or implied, with respect to such information, including any information on linked sites and including, but not lim ited to, accuracy of the information or its completeness, timeliness, usefulness, adequacy, continued availability, or ownership. 15 P a g e