&S ontrols Limited Upland Road exleyheath KENT. DA NR Tel: Fax: Email: Web: + (0)0 0 + (0)0 0 sales@candscontrolsltd.com www.candscontrolsltd.com VP Series Relay Miniature radle Relays World-wide compatibility ma/mv to A or 0V switching RoHS compliant istable magnetic latching types available Mounting options T and T approved types available Life tested to 00,000,000 mechanical operations omprehensive technical service road custom capability Keyswitch Varley VP Series miniature cradle relays offer contact, coil and mounting options to meet a wide range of applications. They are extremely reliable, proven through many years manufacture and use and are compatible with all similar products manufactured world-wide.. SUMMARY OF TYPES.. ASI VP SERIES ontacts:,, & pole contact arrangements are available, with a choice of contact materials to suit applications from low to heavy duty. oils: Nominal coil voltages range from to 00V D and to 0V A to give the user a liberal choice of operating voltages. A Operation: For A operation a range is available with built in rectifiers. Sensitive operation: Special adjustments can be made which provide increased sensitivity of operation, denoted by SEN in the ordering code. Mounting: Available as a plug-in relay (also suitable for direct wiring) or for printed circuit board mounting with alternative pin layouts. Socket and Retaining lip: Relay sockets and retaining clips (ordered separately) are available to suit the different case sizes. Sockets are available with printed circuit pins or solder tags. Omission of Earth Screw/Pin: For Applications where an earth facility is not required, the earth screw or pin can be omitted, obviating the need to drill printed circuit boards or panels. Earth lip: Wiring sockets are supplied complete with an earth clip (loose piece) enabling the relay to be earthed via the fixing screw... VPR Series istable, polarised relays with either single or double wound coils, capable of being pulsed at a minimum of 0 milliseconds... Telecom approved relays These relays conform to ritish Telecom codes T and T. For T the contact material is always code 'G' while for T code 'F' is used. VP Relay-&S ontrols Ltd. // Page of
. SHEMATI DIAGRAMS The arrangements shown are applicable to all asic VP Series relays. They are also applicable to the VPR Series where relevant; see Standard ontact Arrangements and ase Sizes. For additional contact arrangements available contact sales. POLE 0 0 or A changeovers HD changeovers, T make before break HI break HI make HI make + break POLE 0 0 0 0 POLE or A changeover HD changeover make before break 0 0 0 0 0 0 or A changeover make before break or A break or A make POLE 0 0 0 0 or A break or A make VP Relay-&S ontrols Ltd. // Page of
. STANDARD ONTAT ARRANGEMENTS AND SIZES Table ontact Type S / T / A / HI HD No. of Poles asic VP Series ase Sizes M VPR Series ase Sizes M SEN Options available for all types of Relays except HD and VPR Relays. M = make. = break. = changeover. S = standard single contact (0. or amp). T = twin contact (0. or amp). A = amp single contact. HI = High Insulation HD = heavy duty A contact (increased pin spacing). = not available. Note that the amp (A & I) contact material is 0% Silver with 0% admium Oxide (DX alloy). A relay fitted with amp contacts in a quantity greater than two changeover or four make or four break, will have >0.% admium Oxide content.. ase Sizes, Socket & Retaining lip Order odes. Table ase Size Dimensions (See drawing) Printed ircuit Socket Wiring Socket Retaining lip A A Order ode Order ode Order ode. 0.. SVP0P0 SVP0W0 SVP0R0 0 0.. SVPP0 SVPW0 SVPR0. 0.. SVPP0 SVPW0 SVPR00 An earth clip is supplied with each wiring socket (loose part). OIL DATA.. ASI VP SERIES Table. Short coils (case,,, see tables & ). The tables below list the characteristics of all standard asic VP Series relay coils. Note, against 'Minimum Volts' the subheadings refer to various options, i.e. S = Low level or light duty single contacts, T = twin contacts, A = Amp contacts, HD = heavy duty contacts, SEN = sensitive adjustment. The characters below these subheadings refer to the number of poles and contact action, i.e. M = make, = break, = changeover. Table D oil (Nominal Voltage) Max. power at 0 ambient = W Resistance (ohm) ±0% (except *±%) Number of Turns 0 0 0 00 0 00 0 00 00 00 0 00 00 000 00 000 *000 0000 *000 000 MAXIMUM VOLTS (0 ambient) 0 0 0 S T A HD SEN..0..0.0.0.0.0.0.0 Min Volts,M,.0.0 0.0.0.0.0.0 0.0.0.0... 0...0.0.0 0.0 0.0......0.0. 0.0.0,M, M.....0.0..0.0 00.0,M,... 0.0...0.0..0 VP Relay-&S ontrols Ltd. // Page of
.. M TYPE OILS Table. M Type (Short) coils for relays with, M or contact actions and for other actions where lower minimum operating voltage is required. Designated in the ordering code by 'M' immediately after the coil voltage. Table D oil (Nominal Voltage) M M M M M M M M 00M 0M Resistance (ohm) ±0% (except *±%) Number of Turns 0 0 00 0 00 0 0 00 0 00 00 00 00 00 00 000 *0 00 MAXIMUM VOLTS (0 ambient).. 0. 0 0 S T A HD SEN Min Volts......0...0.0,M,... 0...0..0.0.0.... 0.. 0..0.0.0.........0.0,M,,M,,M........ 0.0.0,M,........0.0 0.0,M,.....0.0.0 0.0.0.0,M,,M,.0.0.0 0.0.0.0.0 0.0 0.0.0.. ASI VP SERIES WITH UILT-IN RETIFIERS FOR A OPERATION Table. Designated in the ordering code by 'A' immediately followed by the nominal voltage. Short coils (ase, or see tables & ). Table oil Type (Nominal Voltage) Resistance Ohms ±0% Voltage @ 0Hz Maximum Minimum A (Double coil) x.. A*.. A* A* 00 0A* 0 0A* 0 0A* 00 oil power: Frequency range: Available contact combinations:.va max..w max. 0-0Hz & light duty contacts,, M or twin contacts,, M or amp contacts heavy duty contacts (HD) *A to 0A have a single coil with a series/parallel diode arrangement... VPR SERIES ISTALE POLARISED RELAYS Short coils (ase, or see tables & ) These are bistable polarised relays having magnetic latching by means of a ceramic magnet. The relay can be pulsed at 0 milliseconds (minimum) sine or square wave. The physical dimensions and base terminals are identical to the asic VP Series, and they are available in single or double wound coils. Data in the tables below apply to available contact arrangements i.e. or pole changeover, pole make or break.... SINGLE WOUND OILS AT 0 (TERMINALS &) Table. Table Polarity (N closed) To change state a) Apply positive to terminal b) To return to N closed, apply negative to terminal D oil (Nominal Voltage) 0 Resistance ohms ±0% (except *±%). 00 0 00 00 00 *00 Number of turns 0 00 0 000 000 00 0 000 000 Nominal Voltage 0 Minimum Voltage.... 0 Maximum Voltage... 0 0 Max. Pulse Voltage. 0 0 0 VP Relay-&S ontrols Ltd. // Page of
... DOULE WOUND OILS AT 0 (TERMINALS & AND & ) Table. Table Each coil may be used separately as above. To change state using both coils a) Apply positive to either terminal or terminal. b) To return to original position apply negative to terminal or terminal. RELAY ONTATS.. ONTAT MATERIALS ode A Fine silver (gold flashed) the most effective material for general purposes and has the highest conductivity of all metals. The bare metal is prone to tarnishing in sulphurous atmospheres, but in all but the very lightest of settings, the wiping action of all the contacts rapidly breaks down the film. ode F % Gold % Nickel arc and weld resistant, hard wearing and the best material for low level applications. (T type ontact Material) ode G 0% Palladium, 0% Silver - It is arc resistant and the least costly of the tarnish-free alloys at normal temperatures. (T type ontact Material) ode I Silver admium Oxide - a hard sintered alloy ideally suited for heavy duty applications with inductive loads. It is less prone to material transfer than Silver on D circuits, but it is not suitable for low voltage low current applications.. ONTAT RATINGS Table. Table ontact Type ode Max. Amps Max. Volts Max. Watts Max. VA Gold/Nickel (%:%) Single & Twin ontacts Fine Silver (Gold Flash) Single & Twin ontacts Palladium/Silver (0%:0%) Single & Twin ontacts Amp Silver/admium Oxide Single contact HD Fine Silver (Gold Flash) Single ontact D oils (nominal volts). 0 00 Resistance ohms ±0% & (*±%) & Number of turns & &... 00 0 00 00 *00 *0... 00 00 00 00 *00 *0 0 0 0 0 00 00 00 00 000 0 0 00 0 00 0 0 00 000 Minimum volts.0..... Maximum volts (continuous).0..... 0 0 Maximum pulse volts.0 0.. 00 0 0 0 F 0. 00 0 A.0 00 0 0 G.0 00 0 0 I.0 0 00 00 A.0 0 00 00 Relays VP*/A/*A*/* (silver) no longer available, replacement relays supplied with silver cadmium contacts (ode I). ONTAT TYPES Single light duty & Amp Twin (T) light duty Heavy duty (HD) Suitable for most general purpose applications. Recommended for all critical applications that require reliable high integrity switching. The relays are constructed using two sets of standard contacts (of the selected type and rating) fixed to bifurcated contact springs. Made from fine silver (code A), the contacts are physically larger than the standard light duty contact to allow for increased dissipation. Double spacers are inserted between springs so that the spring set is larger than that on the normal duty Amp (A) contacts. onsequently the case size and terminal numbering is different from the A types. VP Relay-&S ontrols Ltd. // Page of
. RELAY ODE REOGNITION. Relay Series VP # Standard relay VPR # istable polarised relay # = Number of poles,,, or (sets of contacts) Operation Unspecified Standard setting SEN Sensitive setting Mounting style Unspecified Plug-in/solder P Plug-in/wired types DM Printed circuit.mm (0.") grid ontact type Unspecified Standard light duty T Twin contacts light duty A Amp (silver cadmium oxide only) HD Heavy duty (silver) ontact functions M Make (N/O) reak (N/O) hangeover (/O) K Make before break ontact material A Fine silver (gold flash) F Gold/Nickel (%:%) G Palladium/Silver (0%:0%) I Silver cadmium oxide Terminal material Steel, nickel plated (standard) oil identification oil voltage required Example of Relay Descriptive code = VP / SEN/ P/ A/ I / / T. (for M type coils insert M after voltage; for bifiliar windings insert resistance in lieu of voltage) Overlaid (twin) coil winding (voltage )W(voltage ) Special requirements A uilt-in rectifier T Tropicalised coil RSD Anti-residual stud ifilar windings LES Less earth screw (plug-in and P types) LEP Less earth pin (direct mount (DM) types) Typical examples of relay codes: - VP/P/A//RSD/T/LES VP/A/A VP/HD/A/0ohm asic pole changeover action with.mm pitch P terminals, amp silver contacts, volt D coil, anti-residual stud, tropicalised, less earth screw. asic pole changeover action with amp silver contacts, volt coil with built-in rectifier for A operation. asic pole changeover action with heavy duty silver contacts, 0ohm bifilar windings. VP/F/W (pull and hold) asic pole break action with 0. Amp gold nickel contacts, overlaid coils (volt inner 'pull', volt outer 'hold'). For product support, information on our extensive range of VP relay configurations and options available, project support enquiries and replacement support for cradle relays not available from their OEM s, contact sales. VP Relay-&S ontrols Ltd. // Page of
. Outline drawings and layout diagrams. PLUG-IN / WIRING RELAY. SIZE. SOKETS. 0 0 A WIRING SOKET MAX.. PRINTED IRUIT SOKET. Hole for manual operation SIZE.. 0 A SIZE 0.. MAX Figure Figure PRINTED IRUIT OARD LAYOUTS opper side up 0. P Relay. Relay ase 0.. opper side up....0 A.0.. Terminal centres are identical to the wiring/plug-in relays. 0. standoff DM Relay or Printed ircuit Socket A.... Relay ase.0 x 0.. max. Earth Pin Figure Terminal numbering is identical to plug-in wiring relays (figure ), but with 'staggered' pin layout on DM & P sockets as shown. A Hole for manual relay operation if required Hole required for P relay with standard A earth/mounting stud. Not required for DM relay, P socket or P relay with LES in its code. VP Relay-&S ontrols Ltd. // Page of
. ONTAT NUMERING (See figs & for pin positions for each case size) Relays with changeover contacts see table Relays with make or break contacts see table 0 Table - pole - pole - pole Type S, T & A HD S, T & A HD S, T & A ase size NO OM N 0 0 0 0 0 0 Table 0 -pole (case size ) -pole (case size ) -pole (case size ) ontact pairs 0 0 0 VP Relay-&S ontrols Ltd. // Page of