Specialists in Remote Monitoring

Similar documents
RMU3 Remote Monitoring Unit and GPS Interrupter

REMOTE MONITORING AND CONTROL SYSTEM

CIPS, DCVG & GPCM Pipeline Surveyor. Corrosion Control Equipment

Surface Potential Surveys Training Manual DA Meter Version

Monitoring DC Decoupling Devices at Isolation Flanges for Compliance and Pipeline Integrity

DCVG Coating Survey Data Sheet

Technical Seminar for Cathodic Protection to GOGC Design Unit Specialists. Dr. Nick Kioupis, Cathodic & Lightning Protection Section Head, DESFA

Radiodetection Pipeline Products

Pipeline Current Mapper

PIPELINE DEFECT MAPPER

WATCHDOG Tracker CP Test Station Monitor & Data Logger Critical Bond Monitor. Installation and Product Specification Manual

Cathodic Protection & Monitoring

pipeline integrity PCM + Pipeline Current Mapper

60Hz Ratings. Typical Applications. Features & Characteristics. Ratings

Supervision and analyse of the electrical network EN50160 & POWER QUALITY

EverBlu. Wireless fixed data collection system

Instant-Off (I-O) Measurements on Decoupled Systems

ELITE PRO. Automation Components, Inc.

AccuSolar SOLAR POWERED SYSTEM

Static Stray DC Current Interference Testing

WAY AHEAD IN CORROSION CONTROL OFFSHORE WIND. stoprust.com

GEONICA, S.A. - Alejandro Rodríguez, nº Madrid - Spain Tel Fax

Frequently Asked Questions

OVERCOMING THE NEW THREAT TO PIPELINE INTEGRITY - AC CORROSION ASSESSMENT AND ITS MITIGATION -

Electronic Pipeline Technology Ltd

(IDC) INTEGRATED DATA COLLECTION TECHNOLOGY. Presented by: Kevin Pastotnik

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

The wireless alternative to expensive cabling...

HANWELL UTILITY DATA SHEET

Precision Pipeline Locator System User Guide. Rev

Key Features. Base-line surveys for planning Construction site monitoring Road traffic noise monitoring

SPECIAL SPECIFICATION 6744 Spread Spectrum Radio

AUTOMATIC WEATHER AND HYDROLOGICAL STATIONS

Operation Manual for CTL-3000

Environmental Noise Management Sofia December Brüel & Kjær S&V Torben Munk

CATHODIC PROTECTION FIELD TESTING

CORD-Pager USER MANUAL

in Control When It Counts LED Indicators Mounting Bracket Meter Seal Mounting Brackets ½ seal tight or ¾ NPT

Wireless Pulse Counter - 1 Input

Beyond AMI. We Put You in Control When It Counts

Chloride 80-NET Secure Power For Mission Critical Applications 60kVA to 120kVA. AC Power For Business-Critical Continuity

The wireless alternative to expensive cabling...

Architectural/Engineering Specification for a. Microwave Perimeter Intrusion Detection System

ēko Pro Series System

AUTOMATIC WEATHER STATIONS FOR HYDRO-METEOROLOGY

PIPELINE CORROSION RISKS ASSOCIATED WITH AC VOLTAGES

Bloodhound RMS Product Overview

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

AC Voltage- Pipeline Safety and Corrosion MEA 2015

Improve asset protection and utilization

Problem. How we solve the problem.

Wireless Activity Sensors

Trunking Information Control Console

Multilin DGT. Distributed Generation Trip Control Fast & Wireless Trip of Distributed Generators. Control. Advanced Communications

Non-Intrusive Ultrasonic Corrosion-Rate Measurements in Lieu of Manual and Intrusive Methods

Wireless Magnet Detection Sensor

Session Number: 13 Application of Wireless Communication for Monitoring of Critical Infrastructure

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

Brochure nº

SECTION WIRELESS CLOCK/TONE GENERATOR SYSTEM

PRODUCTS. Radios. Accessories As shown, and more GPS. Other PUSH-TO-TALK OVER CELLULAR. Heavy Duty, Bluetooth and Smart Digital Headsets.

Simple Guide to In-Building Coverage Systems

Wireless Temperature Sensor with Probe

Wireless Temperature Sensor

Installation Manual. Ultra RF Analogue Transmitter QC0168. Manual Ref: QC0168. Version: March

The wireless alternative to expensive cabling...

OFFSHORE CATHODIC PROTECTION AND INTEGRITY

Simoco Xd Professional Digital Mobile Radio System. The complete end-to-end DMR solution supporting both Tier II conventional and Tier III trunked

Leica Digisystem i-series Safe and fast location of underground utilities

FE014: Cathodic Protection Systems: Design, Fabrication, Installation, Operation & Repair

STARTRAK PIGGING TECHNOLOGIES, INC. PIPELINE PIG MONITORING

Installation Manual Multi Input Temperature Logger QC0163. Manual Ref: QC0163. Version: FEB17 1.0

Using Remote Data-Logging Techniques to Evaluate Transit System Interference

Connecting Mains Electrical Power

StarTrak Pigging Technologies

Building Intelligence

CR:247 Invictus. Portable Noise Monitor. Features. Features. Applications

Networks of any size and topology. System infrastructure monitoring and control. Bridging for different radio networks

The SFC 1000PA P2DAAA can be mounted on a prover trailer, which can be moved from field to field to provide proving services.

Level Limit Switch nivotester FTL 325 P

TSA 6000 System Features Summary

Leica Digicat i-series Safe and fast location of underground services

DeltaV SIS Logic Solver

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

OMR and Image Scanner. System Solutions. Reliability You Need From The Company You Trust. The Power of Multiple Data Collection Capabilities

MAKING WIRELESS SENSOR NETWORKS TRULY WIRELESS USING RF POWER

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

OASIS. Application Software for Spectrum Monitoring and Interference Analysis

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

PROCESS & TEMPERATURE CONTROLLERS

Mission Critical DAS Solution

DCVG Training Manual DA Meter Version

Advanced, accurate and intelligent monitoring for your transformer

Increasing security. Saving space. Gaining flexibility. Signal Conditioners for Industrial Automation

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

Professional Grade Wireless Communication. Keeping People Connected sm

DMR. PROFESSIONAL DIGITAL MOBILE RADIO Connections that Count

737 LF/HF/VHF/UHF/SHF Spectrum Monitoring System

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

The Rosemount 848T Wireless Temperature Transmitter

Transcription:

ABRIOX www.abriox.com MERLIN CATHODIC PROTECTION MONITORING Specialists in Remote Monitoring

REDUCING THE COST OF DATA COLLECTION - IMPROVING THE QUALITY OF DATA - INCREASING THE EFFICIENCY OF INTEGRITY TEAMS Cathodic Protection (CP) is an important method of preventing corrosion on buried metal pipelines, but it must be applied at the correct level. Every pipeline operator must carry out regular measurements of CP at rectifiers or solar stations and at CP tests points (in impressed current systems) and at sacrificial anodes (in galvanic systems). Some key pipelines crossing main roads, rivers or centres of population may have additional protection against corrosion in the form of a sleeve filled with an inert gas (nitrogen). The gas pressure in the sleeve has to be maintained above a specific threshold, which requires regular checks. Collecting and analysing field measurements is labour-intensive and costly. And (very importantly) they can only be reactive problems can lie undetected for long periods, during which the pipeline is insufficiently protected. INTRODUCING MERLIN Abriox has developed the MERLIN system with input from pipeline operating companies and independent CP consultants. The MERLIN system remotely monitors cathodic protection levels at rectifiers and test points along pipelines, and also the pressure within nitrogen sleeves. All measured data is automatically transmitted in a management report to the system HQ where it is displayed and archived in Abriox s icpsm/cpsm software. The system is proactive - identifying potential corrosion problems wherever and whenever they occur and alerting the operator immediately. MERLIN Remote Cathodic Protection Monitors (also known as Remote Monitoring Units - RMUs) are commonly used at: s and Solar Stations - measuring electrical supply, voltage output, current output, ON and OFF potentials and also interrupting the current output for above ground surveys Test Stations, CP Posts and Riser Posts measuring pipe to soil ON potentials, instant OFF potentials, coupon currents On-shore Tanks, Sacrificial Anodes, Isolation Joints and Critical Bonds Nitrogen filled sleeves - measuring nitrogen pressure to ensure sleeve integrity Pipeline sleeves - ensuring sufficient isolation between the pipeline and the sleeve Innovative Design Through careful consideration of what pipeline operators require from a monitoring system, Abriox has been able to combine low power consumption electronics with remote telemetry to create a compact, affordable package offering all the key CP measurements. Our design is intelligent, yet practical. Some of the points our customers repeatedly comment on are: The ease of installation of our monitors. No specialist equipment is required, simply standard tools and a cell phone. The ability to get readings in the field from our monitors. Transformer monitors are continuously powered, so technicians can get readings sent directly to their cell phone on demand. Reliability is ensured by extensive testing during production all units are 100% tested with particular attention to ingress and lightning protection. Benefits With installations across the globe, MERLIN offers major economic, operational, safety and environmental benefits; providing significant cost savings and make our customers operations more efficient by: Reducing the cost of data collection and pipeline surveys Increasing the efficiency of Integrity teams Improving the quality of data Offering zero carbon footprint for data collection Reducing health and safety risks to technicians 24/7 proactive monitoring Technical Success merlin cathodic protection Monitoring MERLIN has been installed on across the globe and has been proven over time to offer the following advantages: Reducing the cost and time for installation Elimination of data loss through product failure Automatic and on-demand transmission of data Reputational benefit to network from faster resolutions leading to increased customer satisfaction Visit us online at www.abriox.com for further information on how our remote monitoring systems can improve your network management

REDUCING HEALTH AND SAFETY RISKS TO TECHNICIANS - ZERO CARBON FOOTPRINT FOR DATA COLLECTION - 24/7 MONITORING - AUTO ALARMS MERLIN GX Transformer Monitor The MERLIN GX Transformer Monitor is a compact Remote Monitoring Unit (RMU) that can be housed within the rectifier cabinet or supplied in a separate enclosure ready for mounting externally. It carries out the functional checks of rectifier output (voltage and current) required in order to ensure a continuous CP supply to the pipeline and to comply with regulatory guidelines. The unit checks that the rectifier remains powered by its external electrical supply. If the power fails, an alarm is transmitted and the unit s internal batteries take over monitoring for up to 2 years. They quickly repay their capital cost when compared to monthly manual checks. The MERLIN GX Transformer Monitor offers additional CP measurements (ON and OFF potentials) as well as the facility to synchronize remotely with other rectifiers on a pipeline for CIPS (Close Interval Potential Surveys) or DCVG (Direct Voltage Gradient) surveys. The Excel model additionally controls a solid state Interrupter to provide a signal for tracing the pipeline route. Compatible with 4G and 3G networks Cell phone test & set-up, on-demand readings and control of rectifier output relay Sealed, weatherproof unit with robust lightning protection and wide operational temperature AC powered (110V to 230V) with 2 year battery backup. DC power option for solar stations Hourly check of rectifier outputs, ON/OFF potentials Synchronization enables close interval surveys to be carried out more quickly, with no rectifier setup Pipeline locate (offered on Excel model) Immediate alarm generation (user pre-set thresholds on all channels) Alarms when protection inadequate or power fails at rectifier MERLIN XT Transformer Monitor The MERLIN XT Transformer Monitor is an externally mounted durable Remote Monitoring Unit (RMU) that monitors the operation of a transformer rectifier or solar station. It carries out the functional checks of rectifier output (voltage and current) required in order to ensure a continuous CP supply to the pipeline and to comply with regulatory guidelines. The unit checks that the rectifier remains powered by its external electrical supply (including from a solar station or wind turbine). If the power fails, an alarm is transmitted immediately and its internal batteries take over monitoring for up to 2 years. Because they are usually deployed in remote locations, they will very quickly repay their capital cost when compared to monthly manual checks. MERLIN XT Transformer Monitor offers additional CP measurements (ON and OFF potentials) as well as the facility to synchronize remotely with other rectifiers on a pipeline for CIPS (Close Interval Potential Surveys) or DCVG (Direct Voltage Gradient) surveys. MERLIN XT uses iridium satellite communications and is designed for use in areas where no cell network service is available. This ensures connectivity across the globe in the most remote locations. Full global satellite coverage with fast messaging Sealed, weatherproof unit with robust lightning protection and wide operational temperature Fully automatic test and set-up (no laptop required) AC powered (110V to 230V) with 2 year battery backup - DC power option Hourly check of rectifier outputs, ON/OFF potentials Control of rectifier output relay for remote synchronized interruption Pipeline locate (offered on Excel model) Immediate alarm generation (user pre-set thresholds on all channels) Electrical Supply Voltage ON/OFF Potential 2 nd Remote Sync SUPER or - EXCEL or Electrical Supply Voltage ON/OFF Potential 2 nd Remote Sync SUPER or - Pipeline Locate Pipeline Locate EXCEL or 4.9 x 3.35 x 2.17 NEMA 4-40 F to +185 F 100% condensing humidity 4G (LTE Cat.1) and 3G networks 2 year life, replaceable battery module Additional protection using recommended arrestors AC supply (indirectly) output voltage 0 to 150V DC 0.1V resolution output current (using shunt) ± 100mV DC 0.01mV resolution ON potential of the pipe OFF potential of the pipe (using optional relay) Fail-safe relay drive, 0.43A maximum at 12V DC nominal Interruption drive, 0.43A maximum at 12V DC nominal Output patterns from 1s to 60s with 0.1s resolution Short circuit and surge protection Synchronization error less than 1ms 8.5 x 12.4 x 6.9 NEMA 4-31 F to +158 F 100% condensing humidity Iridium satellite (meshed constellation) 2 year life, replaceable batteries Additional protection using recommended arrestors AC supply (indirectly) output voltage 0 to 150V DC 0.1V resolution output current (using shunt) ± 100mV DC 0.01mV resolution ON potential of the pipe OFF potential of the pipe (using optional relay) Fail-safe relay drive, 0.43A maximum at 12V DC nominal Interruption drive, 0.43A maximum at 12V DC nominal Output patterns from 1s to 60s with 0.1s resolution Short circuit and surge protection Synchronization error less than 1ms Visit us online at www.abriox.com for further information on how our remote monitoring systems can improve your network management

MERLIN GX CP Monitor INNOVATIVE DESIGN - EASE OF USE - DEDICATED SUPPORT - RELIABILITY - COST-EFFECTIVE - BUILT-IN LIGHTNING PROTECTION The MERLIN GX CP Monitor is a compact Remote Monitoring Unit (RMU) housed within a test post. MERLIN monitors collect CP data automatically, checks the measurements against specified alert criteria and reports immediately if an alarm threshold is exceeded. They can be deployed anywhere on the pipeline network where it is important to record ON/OFF pipe-to-soil potentials, native coupon potentials and measurements of bonding or interfering currents. Alternatively it may simply be that certain measurement points on the pipeline create risks to CP technicians, such as at busy road or rail crossings, or are difficult to access, such as on private land. At these points remote monitoring is very cost-efficient and can improve safety. All measurements are taken automatically by the MERLIN monitor and data is seamlessly sent in a management report to the system HQ where it is displayed and archived in Abriox s MERLIN CPSM software or online via icpsm. Compatible with 4G and 3G networks Cell phone test & set-up Compact size, sealed weatherproof unit for deployment inside test posts Robust lightning protection and wide operational temperature for all extremes Daily CP level check (hourly optional for problem solving) DC and AC monitoring for full corrosion prevention ON / OFF / Native Potentials and coupon current monitoring channels Alarms reported immediately (user pre-set thresholds for all channels) The MERLIN GX CP Hemi Monitor is a compact Remote Monitoring Unit (RMU) designed to fit invisibly within a CP riser post. MERLIN monitors collect CP data automatically, checks the measurements against specified alert criteria and reports immediately if an alarm threshold is exceeded. They can be deployed anywhere on the pipeline network where it is important to record ON/OFF pipe-to-soil potentials, native coupon potentials and measurements of bonding or interfering currents. Alternatively it may simply be that certain measurement points on the pipeline create risks to CP technicians, such as at busy road or rail crossings, or are difficult to access, such as on private land. At these points remote monitoring is very cost-efficient and can improve safety. All measurements are taken automatically by the MERLIN monitor and data is seamlessly sent in a management report to the system HQ where it is displayed and archived in Abriox s MERLIN CPSM software or online via icpsm. Compatible with 4G and 3G networks Cell phone test & set-up Compact size, sealed weatherproof unit for deployment inside riser posts Robust lightning protection and wide operational temperature for all extremes Daily CP level check (hourly optional for problem solving) DC and AC monitoring for full corrosion prevention ON / OFF / Native Potentials and coupon current monitoring channels Alarms reported immediately (user pre-set thresholds for all channels) Pipe-to-Soil 1 MERLIN GX CP Hemi Monitor Pipe-to-Soil 2 or Instant OFF Coupon or Bond DC DC (OFF) AC DC DC (OFF) AC DC AC 3 Channel - - 3 Channel - - - 4 Channel - - Pipe-to-Soil 1 Pipe-to-Soil 2 or Instant OFF Coupon or Bond DC DC (OFF) AC DC DC (OFF) AC DC AC 3 Channel - - 3 Channel - - - 4 Channel - - 4.9 x 3.35 x 2.17 NEMA 6-40 F to +185 F 100% condensing humidity 4G (LTE Cat.1) and 3G networks 5 year life, replaceable battery module DC Potential AC 0-70V AC RMS, 10mV resolution Shunt 0-100mV 0.01mV resolution AC and DC measured All monitoring channels are fully independent Pair of relay contacts, normally closed Contacts open to take instant OFF Contacts rated at 1A at 30V DC 10.83 x 3.15 x 2.36 NEMA 6-40 F to +185 F 100% condensing humidity 4G (LTE Cat.1) and 3G networks 5 year life, replaceable battery module DC Potential AC 0-70V AC RMS, 10mV resolution Shunt 0-100mV 0.01mV resolution AC and DC measured All monitoring channels are fully independent Pair of relay contacts, normally closed Contacts open to take instant OFF Contacts rated at 1A at 30V DC Visit us online at www.abriox.com for further information on how our remote monitoring systems can improve your network management

MERLIN TX Solid State Interrupter IMPROVE INTEGRITY OF DATA FOR AUDITING - PLAN PREVENTATIVE MAINTENANCE SCHEDULES - SUITABLE FOR ALL EXISTING SYSTEMS The MERLIN Interrupter TX is designed for precise solid state interruption of rectifiers connected to a buried pipeline. Used in conjunction with specific MERLIN GX and MERLIN XT Transformer Monitors, it enables interruption (switching of the current output) at a rectifier to be controlled remotely. interruption is used to carry out Close Interval and DCVG (Direct Voltage Gradient) surveys, major ON/OFF surveys at CP test posts and pipeline maintenance work. Compatible with industry standard interruption patterns, the Interrupter TX may be switched on and off, or the cycle changed, from Abriox s icpsm or CPSM software. Interruption and cycle time management can also be controlled from a cell phone when in the field. The MERLIN Interrupter TX is suitable for switching a current of 40A at -40 F to +77 F or 20A at +77 F to +185 F. When coupled with a MERLIN Excel Transformer Monitor the Interrupter TX can also be used for pipeline location. The Interrupter TX will transmit a user defined frequency between 30Hz and 2000Hz. This will provide a signal range far greater than portable transmitters with minimal additional cost over your remote monitoring system, all controlled by either SMS text messaging in the field or from the office via our dedicated software. Compact size for ease of installation within most rectifier enclosures Robust unit housed in metal casing Quick and easy to install, with labelled connections to MERLIN monitor Wide operational temperature for all extremes Can be used worldwide - unlike mercury relays (which cannot be used in certain countries) Designed for all interruption cycles and extended use Precision solid state switching Less than 500us switching delay Electromechanical fail safe Short circuit and surge protection on output Switches up to 20A current (40A below +77 F) Compatible with all industry recognised Close Interval and DCVG survey patterns and most portable above-ground survey equipment Outputs a pipeline locate signal when used with MERLIN Excel Transformer Monitors DATABASE SOFTWARE icpsm & CPSM Data from MERLIN monitors is automatically stored and transmitted in a management report to the system HQ where it is then accessed online via the internet based icpsm or displayed and archived in the PC based MERLIN CPSM software. The software also provides full remote configuration of all MERLIN monitors. An icpsm or CPSM package is required for every MERLIN monitoring network. icpsm (Internet based Cathodic Protection System Manager) is an online database software package for displaying, archiving and exporting data from MERLIN monitors. It also provides full remote configuration of all MERLIN monitors directly from a web browser. Data is held in a client-specific, secure database, hosted by Abriox, where it can be viewed and downloaded from any web browsing device. CPSM (Cathodic Protection System Manager) is a PC based database software package installed on a dedicated PC, usually located within the Corrosion/Integrity Section. CPSM provides full remote configuration of all MERLIN monitors. If required, two instances of CPSM can be installed as separate HQs. This can be useful where CP Engineers are in different locations Changes made at one HQ are automatically updated at the other HQ with a full audit trail of all changes made to the system. Remote access to rectifier and CP data Graphical and numerical data display shows status of all monitors on a pipeline Configurable alerts to specified users Notes facility for locations and individual reports Plan scheduled interruptions for above ground surveys and maintenance Configurable data export and interface options Licences allow different authorisation levels to software/user options icpsm Licence Types Controller Licence - Full control over the icpsm system, including remote monitor configuration. Technician Licence - Operational control but without the ability to change the system or unit configuration. A Technician has full viewing functionality and can also perform operations such as pipeline interruption, taking on-demand readings and exporting data. Viewer Licence - Read-only access to system but no configuration or control of the units. CPSM Licence Types Controller Licence - Full control over the CPSM system, including remote monitor configuration. Viewer Licence - Read-only access to the CPSM system but no configuration or control of the units. 8.6 x 6.9 x 4.2 NEMA 1-40 F to +158 F Switched Terminals: Suitable for M6 ring terminals (included) Control Input Terminals: Suitable for 1.5mm² wire Maximum Switching Voltage: 100V peak Maximum Switching : 40A @ -40 F to +77 F 20A @ +77 F to +185 F Maximum Turn-on/Turn-off Time: 500us Locate Frequency Range: 30Hz - 2000Hz Fail Safe: Electromechanical Control Voltages: 12VDC ± 10% 320mA max for fail safe 12VDC ± 10% 25mA max for solid state relay Output Protection: Short circuit and surge MERLIN Monitor Configuration: Pipeline/Location ID Measurement modes and reporting times Channel labels Shunt/coupon values Chainage distances (CPSM only) Time zone Help wizards (CPSM only) for configuring: Location settings prior to installation Data export settings Communications Data Display: Pipeline overview or monitor location Graphical display with supporting numerical data table Configurable for days/weeks/months/all data and some/all measurement channels Auto-scaling with viewable min/max levels Network and satellite communications information Unit battery level and status information Alarm Identification: Low/high alarm thresholds on all channels SMS (text message) or email alerts to staff All units in alarm highlighted in folders Data Management: Configurable data period and channels Export as CSV file or cut/paste from data table Exportable installed assets snapshot Data export into asset management software Add notes to specific locations or reports On-demand Data from s: On-demand measurements on all channels Status and configuration of MERLIN monitors Synchronized Interruption: Start/stop interruption of all/specific rectifiers Configurable ON/OFF intervals Colour-coded interruption status Data Export: Configurable data export and interface options AC-I-009-MERLIN Datasheet US Web - V4

ABRIOX www.abriox.com Specialists in Remote Monitoring