MECOS-C2 microscopy systems

Similar documents
Automated Digitization of Gram Stains. Centralized Reading. Decentralized Assessment. Improved Quality Management.

EXC500p-- PATHOLOGY MICROSCOPE. EXC500hd -- HD DIGITAL PATHOLOGY MICROSCOPE. EXC500r -- RESEARCH MICROSCOPE EXC500-LABORATORY SCOPE

AUTOMATED MALARIA PARASITE DETECTION BASED ON IMAGE PROCESSING PROJECT REFERENCE NO.: 38S1511

Computational approach for diagnosis of malaria through classification of malaria parasite from microscopic image of blood smear.

Color aspects and Color Standardization in Digital Microscopy

VIDEOTEST-KARYO 3.1 SPECIFICATION

Stereotopix Research. Precision Pathology. Highthroughput. pathology. powered by newcast. Advantages of Stereotopix : RUO

Estimating malaria parasitaemia in images of thin smear of human blood

GALILEO TMA CK 4500 HTS Tissue Microarray Platform

Colony Imaging with powerful Analysis Software

Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

Using a Microscope. Year Group: BVSc1 + Document number: CSL_L07

CLEMEX intelligent microscopy

Media Cybernetics White Paper Spherical Aberration

Exercise 2-A MICROSCOPIC TECHNIQUE & EXAMINATION OF MICROORGANISMS

Enhanced Identification of Malarial Infected Objects using Otsu Algorithm from Thin Smear Digital Images

Exercise 2-A MICROSCOPIC TECHNIQUE & EXAMINATION OF MICROORGANISMS

COMPUTERIZED HEMATOLOGY COUNTER

DMETRIX S (FUTURE) PERSPECTIVES ON DIGITAL IMAGING & DIGITAL PATHOLOGY SYSTEMS

Internal Medicine Imaging Core Emory University Department of Medicine

OPELCO OPtical ELements COrporation LB Objective Series for Biological Use

FRAUNHOFER INSTITUTE FOR INTEGRATED CIRCUITS IIS. MANUAL PANORAMIC MICROSCOPY WITH istix


Microscopy Techniques that make it easy to see things this small.

Morphologi. Advanced image analysis for high sensitivity particle characterization. Particle size. Particle shape

MAKE SURE YOUR SLIDES ARE CLEAN (TOP & BOTTOM) BEFORE LOADING DO NOT LOAD SLIDES DURING SOFTWARE INITIALIZATION

contents TABLE OF The SECOM platform Applications - sections Applications - whole cells Features Integrated workflow Automated overlay

Microbiology Laboratory 2

Digital Pathology and Tissue-based Diagnosis. How do they differ?

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Quick and simple installation and no maintenance needed. 3 Times More affordable Than a normal SEM. Obtaining results in less than 4 minutes

An Image Processing Approach for Screening of Malaria

Teaching Digital Histology

Quick Operation Guide

LAB 1 Introduction to Microscopy

Very short introduction to light microscopy and digital imaging

The microscope is useful in making observations and collecting data in scientific experiments. Microscopy involves three basic concepts:

Leading in Desktop SEM Imaging and Analysis

Chapter 2 The Study of Microbial Structure: Microscopy and Specimen Preparation

Technical Aspects in Digital Pathology

ImageXpress Micro XLS Widefield High Content Screening System. Imaging with a vision.

FLUOLED 21 the plug-and- play microscope for TB (Mycobacterium tuberculosis), based on Olympus CX 21 microscope

ScanArray Overview. Principle of Operation. Instrument Components

INTRODUCTION We believe that every laboratory working in the field of nanotechnology needs an SEM, therefore we would like to introduce to you our IEM

Marine Invertebrate Zoology Microscope Introduction

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

Microscopic Structures

Studying of Reflected Light Optical Laser Microscope Images Using Image Processing Algorithm

MIRAX SCAN The new way of looking at pathology

CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE

Positive Pixel Count Algorithm. User s Guide

The light microscope

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 1: THE LIGHT MICROSCOPE

MICROSCOPE LAB. Resolving Power How well specimen detail is preserved during the magnifying process.

Nikon E800 Operating Instructions.

FEATURES Industry windows paperless solutions High speed portable document scanner is well-suited for a wide variety of Window industry

Figure 1. Oil-immersion objectives available for use with the Lionheart FX.

White Paper Focusing more on the forest, and less on the trees

Direct Contact Fiberoptic Plates for the Detection of Luminescent Cells

Figure 3.4 Approximate size of various types of cells. ~10 um. Red Blood Cells = mm 1500 um. Width of penny Pearson Education, Inc.

Light Microscopy. Upon completion of this lecture, the student should be able to:

TGR EDU: EXPLORE HIGH SCHOOL DIGITAL TRANSMISSION

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

In our previous lecture, we understood the vital parameters to be taken into consideration before data acquisition and scanning.

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

The fully equipped all-round compound microscope for schools, training and laboratories

CARAT 930/950. Hardness Testing & Analysis CARAT 930 / 950

Colony Imaging with powerful Analysis Software

SPOT PathSuite Solutions

Match the microscope structures given in the left column with the statements in the right column that identify or describe them.

Using the Nikon TE2000 Inverted Microscope

Axio Zoom.V16 The Fluorescence Zoom Microscope for Large Fields

Microscopes. A guide to use, general Maintenance, and repair tailored to the Olympus CX-21 microscope

Confocal Laser Scanning Microscopy

Veterinary Technician s Handbook of Laboratory Procedures COPYRIGHTED MATERIAL

QAQC LAB 589 Rappahannnock Drive White Stone Va TEL (866)

Seeing in Biology. Resolving Power of Optical Devices. Bio 101 Laboratory 2. Microscope Intro to Cell Cycle Mitosis

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

The AutoScope: An Automated Point-of-Care Urinalysis System. Sidney R. Primas and Charlie Sodini

MICROSCOPE (3 x 2 hour lesson)

11 Optical Microscopy

Lab format: this lab is delivered through a combination of lab kit (LabPaq) and RWSL

Microbiology: Observing Bacteria Laboratory -1. Name Date

Quick Guide for Zeiss 710 Laser Scanning Confocal MGH Cancer Center

Light microscopy BMB 173, Lecture 14, Feb. 21, 2018

DIGITAL-MICROSCOPY CAMERA SOLUTIONS USB 3.0

State Library of Queensland Digitisation Toolkit: Scanning and capture guide for image-based material

THE ULTIMATE DOCUMENT EXAMINATION SYSTEM STATE-OF-THE-ART SPECTRAL ANALYSIS FORENSIC LABS SECURITY PRINTERS IMMIGRATION AUTHORITIES

Cellular Bioengineering Boot Camp. Image Analysis

H S P. User Manual. Cat.-No

8/28/2012. Total Lab Automation in Microbiology: Much Closer than You Might Think September 6, Microbiology Yesterday

User Manual. Cat.-No /1

Y N C R O S C O P Y A DIVISION OF THE SYNOPTICS GROUP

Multi-resolution Cervical Cell Dataset

Mirtec MV-3 Series Desktop AOI Systems Now with 5 and 10 MP camera!

Ex 1: Introduction to the microscope

Practical work no. 3: Confocal Live Cell Microscopy

LSM 710 Confocal Microscope Standard Operation Protocol

PHYSICS. Chapter 35 Lecture FOR SCIENTISTS AND ENGINEERS A STRATEGIC APPROACH 4/E RANDALL D. KNIGHT

Observing Microorganisms through a Microscope

Transcription:

MECOS-C2 microscopy systems

Microscopy systems of the MECOS-C2 family production LLC "Medical computer Systems (MECOS)" belong to a class of scanning microscopes-analyzers and are intended for: Increase of speed, accuracy, sensitivity, diagnostic significance of the group of well-known methods of analysis; Improvement of labour conditions and productivity; Creation of archives of digital copies of specimens, telemedical consultations, remote quality control and training; Automation of laborious operations of microscopy and measurements for research methods. Systems MECOS-C2 are robots, performing the loading and identification of specimens, moving the field of view in the 3d space of the specimen with navigation, selection of representative areas of analysis, detection, recognition, shooting, sorting, measurement, collection of samples of objects of analysis of the given types, formation of representative digital copy of the specimen, record of results in a database and rendering of means of visualization and remote access. Consumers: Laboratories medical, sanitary-epidemiological, research, forensic medical examination, production, veterinary.

Platform 1-М5 Platform 8-О9 Platform 200-О9 MECOS-C2 platforms for offline servicing party of 1/4/8/50/200/400 slides: 1- computer, 2 - monitor, 3 - control unit, 4 - motorized focus, 5 - motorized stage, 6 - digital camera, 7 - microscope, 8 - motorized turret, 9 - barcode scanner, 10 - power supply, 11 - motorized oiler, 13 - glasses loader

Automatic Scanner MECOS-C2-MECO-SCAN Characteristics: Microscopy of bright field or fluorescent; Objectives of the entire range of apertures; Automated production of the slide Map to select the scan area; Automated production of 2d or 3d digital copies of specimens - virtual slides (VS) - for viewing on a monitor without loss of resolution and with navigation by Map. Types of specimens and VS: 2D VS of thin specimens (cytological slides increase up to 100x; histological slides increase up to 40x); 3D VS of thick specimens with a layered shooting of each field of view at several levels of focus depth (histological slides increase more 40x; wet specimens such as sediments of urine, feces, saliva, sperm, spinal fluid, blood under cover glass or in cameras; thick blood drop smear for malaria tests; some types of prints).

Analysis region selection functions: With automatic generation of the Map of the slide, with selection on the Map outer boundaries of the stained areas/cover glass or areas by specified features (optical density/brightness, color, morphology); Auto scan on specified coordinates for specimens with a fixed location (liquid based cytology (LBC), biochips, slide tablets, slide-cameras). Speed and digital resolution: 2D VS: Increase mm sq/sec μm/pixel 4х 48; 1,72 10х 38; 0,7 20х 15/7 0,5/0,2 40х 6; 0,22 60х 3,9; 0,17 100х 1,2; 0,07 3D VS at 15 x 15 mm, 20 x, 8 layers of depth of focus: scan time 240 seconds, 0,5 μm/pixel.

Scheme of the autonomous manufacturing by MECO-SCAN of virtual slides for party of glasses with automatic selection of the scan areas Glasses Virtual slides Data base Maps with borders of scanning

Automatic Scanner-Analyzer MECOS-C2- MECO-HEMO for analyses of blood smears 1. On the lens 4x is searching for the working zone of the smear. Automatically applied a drop of immersion oil. 2. On the lens 20x oil in the working area is searching for and collecting a sample of WBC specified amount. 3. Samples collecting of RBC and PL is carried at 100x oil in the region of working area with unbroken RBC morphology. 4. Repeated shooting WBC on lens 100x oil by sample coordinates before found. Blood smears of manual or automatic manufacturing. Capacity up to 90 blood smears per hour.

Automatic sorting of RBC, WBC with cell type galleries in the database. Ergonomic visual control of automatic sorting with interactive adjustment much faster and more efficient than manual microscopy. Routine analysis of large samples of cells (WBC to 400, RBC to 2000) to collect cells under their low concentration, to increase sensitivity to rare types of cells. The automatic cell morphometry.

Integration of external data, leukogram, categorical and quantitative evaluation morphology of RBC population, platelets histogram and relative concentration to RBC.

MECO-HEMO can be used for analyses of animal blood smears. Self-learning function of MECO-HEMO Analyzer is available to adapt automatic WBC sorting for animals of a specified types.

Automatic Analyzer-Scanner MECOS-C2-MECO-PARAS for analysis of biomaterials for protozoa and helminths MECO-PARAS performs automatic generation of 3D virtual slide (VS) of the specimen and automatic detection of helminthiasis. Types of specimens: a) specimens of feces, swabs, soil, sewage, water, fish, shellfish, crustaceans, amphibians, reptiles and their products under cover glass; b) specimens of feces from filtering test tubes in slide-camera of Fe-5 motorized station. Scanning objectives: from 20x to 100x oil. When the 20x/0.75 is applied the digital resolution of 3D VS allows to view as eggs of helminthes as majority of protozoa. Scan rate: 15 x 15 mm cover glass from 2.5 minutes; Slide-camera of the Fe-5 from 1 minute.

Not available for manual microscopy completeness and speed of Visual analysis using MECO-PARAS digital 3D VS. Viewing of the entire area on the full depth at different scale to search for objects of different types, with the formation of the Galleries of the detected objects.

Automated Search and Sorting eggs of helminths in VS as a "second opinion". A quick visual check and adjust the results of automatic detection and sorting using built-in Atlas of helminthes and protozoa.

Automatic Scanner-Analyzer MECOS-C2-MECO-MYCOBACT: Cytological smears on micobacterium coloured by Ziehl-Neelsen for microscopy in transmitted light or by fluorochromes for fluorescence microscopy; Mapping of the slide, automatic or interactive selection of analysis region of a given size; Automatic generation of digital virtual slide (VS) for ergonomic Visual analysis of the smear; Increase in analysis sensitivity by combining Visual and automatic detection of Mycobacteria; Informatics, database, statistics, filling out forms; Telemedicine and telemicroscopy; Automatic service up to 1/4/8/200/400 smears at different platforms; Capacity up to 30 smears per hour; Maintenance by junior staff.

Automatic Scanner-Analyzer MECOS-C2-MECO-MALARIA: Mapping of the slide, automatic or interactive selection of analysis region of a given size; Creation of digital copies of slides with thick and thin drops of blood, not conceding on the representativeness and the resolution of images in the microscope tubes; Increase in analysis sensitivity by more material being analyzed and collaborative automatic and Visual detection of malarial protozoa; Informatics, database, statistics, filling out forms; Telemedicine and telemicroscopy; Automatic service up to 1/4/8/200/400 smears at different platforms; Capacity up to 30 smears per hour; Maintenance by junior staff.

Automatic Scanner MECOS-C2-MECO-URIN to analyze urine and others biological liquid sediments: Automatic selection of the scan areas under cover glass, in a slide-tablet or in slide-camera; Automatic scanning of natural or stained specimens with standard (10x, 20x) or high (40x) magnification; Formation in scanning area 3D virtual slide for ergonomic viewing on a monitor without losing of resolution; Informatics including database, presentation of results in the forms, telemedicine and telemicroscopy; Loading and automatic maintenance up to 8 specimens.

View of 3D VS with visualization the focus shift during dive to the depth of the specimen.

The MECO-DMM analyzer provides means of quantitative analysis of morphology and optical density. An example of automatic segmentation An example of interactive segmentation MECO-DMM provides convenient Viewer of objects segmented and measured.

The MECO-HYSTOCHEMICAL analyzer implements known Positive Pixel Count methodology to quantify the intensity of histo-(cyto)-chemical markers. Step 1. Interactive selection of the analysis area and 2 color parameters of every pixel of the area. The area can be any, color parameters may be R, G, B, Hue, Saturation, optical densities. Step 2. 2D distribution of color parameters of pixels appears in a scatter plotter (left). An example with parameters G and Hue is shown. Interactive selection of field of color in scatter plotter (left, hatch) allows to segment markers of the desired type ( Positive Pixels (PPs), right, allocated white color). Step 3. To graduate PPs the Histogram of the distribution of PPs on any color parameter is used (left, example of parameter Saturation). PPs of the area that match the specified percentage of the Histogram are shown with different colors (right) for Visual evaluation.

Automatic Scanner-analyzer MECOS-C2-MECO-METAPHASE to collect sample of metaphase plates Standard preparation of a cytological smear; Formation of digital Map of a slide on objective 10x; Searching and positioning of metaphase plates (MP) on the Map, taking into account the degree of disclosure and compact arrangement of chromosomes; Drawing of immersion oil, changing the objectives, focusing, shooting pictures of the MP on the objective with an aperture of up to 1.3 according to coordinates on the Map; Fixing high resolution MP images in the database in standardized formats for Visual analysis or use external programs of cytogenetic analysis; Performance up to 20 glasses per hour; Offline automatic servicing of the party until 1/4/8/200/400 glasses depending on MECOS-C2 platform; Maintenance of junior staff; Telemedicine and telemicroscopy.

Automatic detection of compact metaphase plates during a quick scan of the smear at 10x

bd05377-0001 bd05377-0002 bd05377-0004 bd05377-0003 Automatic shooting at 100x oil and fixing images of MP in database

Telemedicine MECOS-C2 tools with remote access to virtual slides and analyses results for laboratories across the country

MEСOS-C2 microscopy system Made in Russia Manufacturer Medical computer systems (MECOS) Company Registration certificate No 2011/10003 License for the production and maintenance No FS-99-04-002464 Ugreshskaya st. 2, building 72, Moscow, 109089, Russia Tel. +7(495) 9611824 Email: info@mecos.ru Web: http://mecos.ru