Exterior Paint for wood Tables and Benches

Similar documents
TECHNICAL DATA SHEET IVY COATINGS:

NoFire A-18 NV Fire Protective Coating - General Application Procedure & Technical Data

AquaCLAD Water-Reducible Rust Preventative Alkyd

PRODUCT GUIDE: COMPLIANT TOPCOATS. Version:

PRODUCT GUIDE: WATERBORNE TOPCOATS. Version:

Product: Acrylithane HS2 Acrylic Urethane (not for use in California) JONES-BLAIR PAINT FIELD APPLICATION GUIDE

PRODUCT GUIDE: CATALYZED TOPCOATS. Version:

Exterior. How to paint

JONES-BLAIR tm MANUFACTURERS OF QUALITY PAINT SINCE 1928 TYPE OF COATING. Product: Acrylithane HS2 Acrylic Urethane, Primers, Reducers

Identifying Common Interior Paint Defects/ Complaints

WHY PAINT JOBS FAIL. ADHESION: (Loss of)

PRODUCT GUIDE: CATALYZED PRIMERS. Version:

DULUX UNIVERSAL UNDERCOAT

APPLICATION NOTE - SR001. Cold Weather Application

2K weather resistance clear coat A850

PRODUCT DESCRIPTION High quality interior or exterior enamel for surfaces where a glossy durable finish is required

Exterior. How to paint

Primer Surfacer EP II

Primer-Sealers Solutions

SECTION PAINTS AND COATINGS

STAR PAINT. Put some colour in your life COMMON PAINT PROBLEMS AND POSSIBLE SOLUTIONS TEL: FAX:

SECTION PAINTS AND COATINGS. a. Section Submittal Procedures: Requirements for submittals.

WHAT S ON THE MARKET?

UNIT 11: PAINTING, STAINING, AND FINISHING

Paint Problems. Although you ve probably never thought about it, paint. and How to Prevent Them

MAINTENANCE GUIDE: Exterior

EXTERIOR PAINTING

Product Information. 2K Chromatic Sealer NR (National Rule) D8081 White D8088 Red D8085 Gray D8089 Yellow D8087 Black D8090 Blue. Product Description

1. Labels: Do not paint over UL, FMG, or other code-required labels or equipment name, identification, performance rating, or nomenclature plates.

APPLICATION NOTE - SR001. Cold Weather Application

Specification Guide. Portable & Modular Buildings

Sketchpaint. Ideal for turning any smooth surface into a whiteboard. Ready to use in 5 days

NOTE: This product can be used externally if UV Guard is added (BY REQUEST ONLY).

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB

Duraguard ULTRA PREMIUM MATT DATA SHEET FC Description & Uses. Features & Benefits. Colours. Environmental Data & Certifications

Product Data Sheet Brite Red Aluminum

Magnetpaint & Sketchpaint

These Application Instructions cover surface preparation, application equipment and application details for HEMPADUR MASTIC 45880/45881.

SEA45 Water Borne Acrylic Gloss

Primer Pro FOR PROFESSIONAL USE ONLY. Description. As A Primer Surfacer. Mixing 4 1 1

Big Sky Product Information Sheet. Epoxy Prime Primer/Sealer PS3042 (Lt. Gray) PS3044 (Dk. Gray) PS3045 (Black) PS3047 (Yellow Oxide)


Product Information. ECP11 White, ECP15 Gray, ECP17 Black A-Chromatic Surfacer. Product Description. Preparation of Substrate

DuPont ChromaSurfacer 7704S 2K Urethane Primer- Filler

INDUSTRIAL & OEM PRIMER AND TOPCOAT PRODUCT INFORMATION

Sealer-Primer-Undercoat

Product Data Sheet RUST PROOF ANY-WAY SPRAY PAINT. No /14. Aervoe Industries, Inc.

Product Information. ECP11 White, ECP15 Gray, ECP17 Black A-Chromatic Surfacer

Product Data Sheet Awlwood MA Primers OJ3809 / OJ9809 / OJ7809 Specification Data

PAINTING PAINTING

SUNBELT transformer WIDTFA3501 PAINTING TRANSFORMERS WITH WATERBORNE PAINT SYSTEMS INTERNAL USE ONLY DOCUMENT HISTORY

Paint Problems and Solutions Guide. Endura Manufacturing Co. Ltd th Street Edmonton, Alberta T5L 2J

K 200/ Acrylic Urethane Primer Surfacer Form P-151 (9/91)

A. Section includes surface preparation and the application of paint systems on exterior substrates.

U.S. General Services Administration Historic Preservation Technical Procedures

Bulldog Adhesion Promoter System

CHEMICAL RESISTANT EPOXY

Agenda. Interior Painting Exterior Painting Typical Problems Low VOC Paints

F.S.P.M.A. PAINT SPECIFICATION DIVISION 9 FINISHES SECTION INTERIOR MP-28.6 ACRYLIC-BASE, SEMI-GLOSS, EXTERIOR, WHITE AND TINTS

Superior Industries Inc.

INSPIRED INTERIOR FLAT

MAINTENANCE GUIDE: Interior

Aerodur 3001 Base Coat Special Effects

Troubleshooting Guide. Solutions to Common Finishing Problems

Gray Urethane Surfacer (Low VOC)

Bid No :01 Exterior Roynon Elementary & La Verne Heights (Alternate #1) SCOPE OF WORK

C Paint. Product Information Sheets

Painting Wood. 1 of /01/27 01:45 PM. One-component paint system on wood (all wood types)

SILICONE RESIN PAINT FOR MASONRY FACADES

Finishing Finishing Instructions Painting Tips Aluminum Astragal Painting Doorlite Frame Finishing

Please also carry out relevant test patches to ensure product compatibility and colour satisfaction.

8-746 High Production Non-Sanding Primer Grey GS907

DuPont Plas-Stick 2332S Low VOC Adhesion Promoter

HANDLING INSTRUCTIONS:

10P20-44MNF High Solids Epoxy Primer

TECHNICAL INFORMATION CLEAR CONCENTRATED INDUSTRIAL VARNISH BARNIZ INDUSTRIAL CONCENTRADO TRANSPARENTE

Paint problems and. Solutions. Identifying and solving common paint problems Finding the right paint products to fix the problem

Application Handbook for Homes/Buildings

SECTION 025 INDUSTRIAL PAINTING

Metal 3in1. Applied directly to rust A smooth gloss anti-rust enamel paint for metal surfaces

SECTION PAINTING

Cleaning Procedure INTRODUCTION:

Trouble Shooting. Tech Tips

CHEMICAL RESISTANT EPOXY

Permasolid HS Premium Surfacer 5310

WEGTHANE HPA 501 (HPA 501/ HPA 502/ HPA 503/ HPA 504)

Surfaces Garage Doors Fiberglass Doors

A: Proposed Scope of Services. B: Site Location Map. C: Selected existing conditions photographs.

DESCRIPTION/APPLICATION HK RESEARCH GEL COATS DESCRIPTION

P Waterborne Primer-Surfacer-Grey

Primer / Primer Surfacer

APPLICATION HANDBOOK for BUILDING COATINGS for Thermal Insulation, Mold Resistance, UV Resistance, Lead Abatement

Data Sheet 5741 Englisch

#85-2-5A: PAINT STRIPPING AND FINISH ANALYSIS AND CORRECTION - (Aug 7, 1985)

BASF Architectural Coatings Developing and Formulating for Next Generation Durability

A. Section includes surface preparation and the application of paint systems on the following exterior substrates: 1. Steel and iron.

Use suitable respiratory protection Akzo Nobel Sign Refinishes recommends the use of a fresh air supply respirator.

Gloss Volume Solids 88 ± 2% (ISO ) VOC. Overcoating Data 10ºC 25ºC 35ºC Min. 24 hours 12 hours 8 hours Max. 72 hours 24 hours 24 hours

Physical constants Finish: ASTM D Flash point: Rangan Far, s Adding thinner to a paint may change the flash point of the diluted material.

Interior. How to paint

Transcription:

Page 1 of 5 DESIGN STANDARDS FOR: EXTERIOR PAINTING Exterior Paint for wood Tables and Benches 1. Wood tables and benches, including trash receptacle slats, shall be painted with one coat of primer and two coats of color by Parker Paint, color Vashon.

EXTERIOR 100% ACRYLIC SEMIGLOSS LATEX PRODUCT DATA AVAILABLE IN: BASES: 300 White Base 305 Medium 310 Deep 320 Accent 330 Neutral FLEX GLOW 300 RECOMMENDED PRIMERS: WOOD: 450 Exterior Alkyd Primer 1700 Int/Ext Alkyd Primer 2333 Flex Prime Acrylic Latex HMISCODE: HEALTH: 1 FLAMMABILITY: 0 REACTIVITY: 0 PERSONAL PROTECTION: B Design Standard No. 09911.00 Page 2 of 5 COLORS: 360 White MASONRY CONCRETE: 1840 Alkali Resistant Primer 2333 Flex Prime Acrylic Latex 2345 Flex Bind DESCRiPTiON: PARKER PAiNT's FLEX GLOW is a i00% Acrylic Semi Gloss latex enamel for use on properly prepared exterior smooth and rough trim and doors. PARKER PAINT's FLEX GLOW has excellent gloss, color retention, flexibility, adhesion and weathering properties. PARKER PAINT's FLEX GLOW can be applied to most previously painted or properly primed surfaces. NOT RECOMMENDED FOR: Direct application to bare wood or metal surfaces. Without the use of an appropriate primer, some factory coated aluminum, metal, plastic and particle board sidings may require special painting procedures. Ask a PARKER PAINT Representative for additional instructions about possible coating problems on substrates of this type. SURFACE PREPARATION: Before applying, read and follow all directions and cautions on container label. The moisture content of the substrate to be painted should not exceed 15%, as determined by a moisture meter. All old and new surfaces to be painted must be sound, clean, dry and free of dirt, oils, chalk, mildew, blistered or peeling paint and any other contamination that can affect the new paint film. This can be achieved by scraping, sanding, wire brushing, pressure washing, sandblasting or any other approved method of preparing a substrate for painting. A painted glossy surface in good condition should be sanded first to provide good adhesion of a paint coating. Clean and fill all major cracks and voids. Correct any moisture problem areas. Caution should be taken if a flammable product is used for cleaning. FLEX GLOW finish coating may require two or more coats depending on the degree of color change and/or surface condi~ tion. For special painting procedures, ask your PARKER PAINT representative for additional instructions. METAL: 1652 Rust Proof Red Alkyd Primer 1655 White Metal Alkyd Primer 1679 Speed Dry Aikyd Primer GALVANIZED & ALUMINUM: 1821 Galv 0 Prime APPLICATION: Mix paint thoroughly before using. RECOMMENDED DRY FILM THICKNESS PER COAT: 1.85mils. WET FILM TO ACHIEVE OFT: 5.3 mils. (Unthinned material) THEORETICAL COVERAGE AT RECOMMENDED OFT: 300 sq. ft. per gal. Coverage will depend upon the method of application, porosity and texture of the surface. Do not apply exterior paint coatings during rain, or in damp, foggy or freezing weather, Any one, or all, of these conditions can affect the drying, appearance and durability of a paint coating. RECOMMENDED APPLICATION TEMPERATURES AND HUMIDITY: 50-90 F (10-32 C) 55% RH DRYING TIMES: TACK FREE: 4 hrs. @ 77 F (25 C) RECOAT: 8 hrs. 50-55 RH DRY HARD: 24 hrs. NOTE: See back under Precautionary Information. EQUIPMENT RECOMMENDATIONS: BRUSH/ROLLER: Use premium quality nylon or polyester brushes and roller covers. To insure a uniform finish and avoid lap marks, maintain a wet edge and apply with a fully loaded brush or roller cover. AIR ATOMIZED SPRAY: With a suitable nozzle set up. AIRLESS SPRAY: With tip size of.015 to.021. THINNING: No thinning is necessary. If necessary, add no more than 4 fl. oz. water per gallon. Do not add solvents or oils to this product. CLEAN-UP: Clean all tools and equipment immediately after use with clean, warm, soapy water. Rinse with clean water. 3003 S. Tacoma Way. PO Box 11047. Tacoma, Washington 98411. (253) 4731122. (800) 8264308 (continued over)

Page 3 of 5 PRODUCT ANALYSIS: 300 White Onlv PIGMENT-------------------------------------------- 20 % Titanium Dioxide ----- 95% Nepheline Syenite 5% 100% VEHICLE -------------------------------------------- 80% 100% Acrylic Emulsion -- 67% Water 20% Glycol 6% Ester Alcohol 3.5% Additives 3.5% VEHICLE TYPE: Acrylic Latex SOLVENT TYPE: Water 100% 100% VOC GRMS/L: 226 grams/liter - 1.88 #/gal. APPEARANCE: Semi Gloss GLOSS RANGE: 55-65 @ 60 85-95@ 85 VISCOSITY: 80-90 KU's (@ 77 F [25 CJ) % SOLIDS BY WEIGHT: 48% ± 1.5% % SOLIDS BY VOLUME: 35.1%±1.5% WEIGHT/GAL.: 10.0-10.3 lbs/gal. PACKAGING: FIVE: X ONE: X QT: SHELF LIFE: N/A TINTING: PARKER PAINT Color Guild Colorants. Check colors before applying. Custom mix colors may not dry to an exact match to the sample chip. Apply the paint to a small test area. APPLICATION OF A COLOR COULD CONSTITUTE ACCEPTANCE OF THE COLOR. PARKER PAINT assumes no responsibility expressed or implied for mismatched colors after it has been applied. No refunds on custom mixed colors unless the company is in error. PRECAUTIONARY INFORMATION: CLOSE CONTAINER AFTER EACH USE KEEP OUT OF REACH OF CHILDREN DO NOT TAKE INTERNALLY FLASH POINT: N/A D.O.T. (REQUIREMENTS): N/A STORE in a clean, dry place. KEEP FROM FREEZING RECOMMENDED STORAGE TEMPERATURES should be between: 40-100 F (5-38 C) EXTINGUISHING MEDIA: Water may be used to cool closed containers to prevent pressure build-up and explosion when exposed to extreme heat. NOTE: Dry times will vary depending upon ambient temperatures and atmospheric conditions. Dry hard in 24 hours does not mean that the paint coating has fully cured. It has reached a stage where handling can be achieved without removing the paint film under minimal pressure from the hands or fingers. ' Scrubbing the paint coating or washing with a harsh cleaner before it is fully cured could result in the removal of the coating and/or marring the finish. Allow a minimum of 30 days for curing. Do not apply an exterior paint coating during rain, or in damp, foggy or freezing weather. Any one, or all ofthese conditions can affect the drying, appearance and durability of a paint coating. Do not apply a paint coating to a hot surface or in the direct sun light. One or both could cause the coating to blister and/or peel. "Surfactant Bleed": Sticky white, brown or clear runs or spots can occur on newly painted surfaces If exposed to moist conditions before surfactants can evaporate from the drying paint film. Cedar, Redwood, Fir plywood and many other wood by-products contain a water-soluable extractive which can discolor white or light colored latex and oil base paints. This extractive staining can develop months after the finish is applied. It is recommended that a primer, specifically formulated to retard this discoloration be used first. There is no guarantee that Q!lll_@fil of either a latex or oil base primer will prevent EXCESSIVE extractive bleeding. USE WITH ADEQUATE VENTILATION. Avoid prolonged or repeated contact with skin and breathing vapors or spray mist. Coatings should only be applied when ventilation is adequate. If there is not adequate ventilation, applicators should wear respirator approved by NIOSH I MSHA (TC-23C or equivalent). ENVIRONMENTAL CONSIDERATIONS I Formulated without lead or mercury. MATERIAL SAFETY DATA SHEET AVAILABLE ON REQUEST REVISED: 4/2000 (Supercedes 1/99) To the best of our knowledge, the Information presented herein Is correct. No guarantee of accuracy Is given orlmplled. The Information Is subject to change without prior notice. Because conditions of surface preparation, material handling, and application are beyond our control, we assume no responslbllltyforproduct perform a nee or Injuries resulting from use of our products. Llablllty, ff any ls limited to the replacement of products. No otherwarranty or guarantee of any kind Is made by the seller, express orlmplled, statutory, by operation or law or otherwise, Including merchantablllty and fitness for a particular purpose.

Page 4 of 5 FIRST KOTE 450 AVAILABLE IN: BASES: EXTERIOR ALKYD PRIMER PRODUCT DATA 450 White RECOMMENDED PRIMERS: WOOD: Self Prime HMISCODE: HEAL TH: 2 FLAMMABILITY: 2 REACTIVITY: 0 PERSONAL PROTECTION: B COLORS: 450 White GALVANIZE & ALUMINUM: 1821 Galv 0 Prime DESCRIPTION: PARKER PAINT's 450 First Kote is an exterior alkyd primer for use on most new properly prepared wood surfaces. PARKER PAINT's First Kote can be used for spot priming bare wood areas when repainting or as an overall wood surface primer and can be top-coated with an exterior latex or oil base finish paint. PARKER PAINT's First Kote is formulated to retard most all discoloration of soluble wood extractives (Tannin Bleed). In some cases, a second coat of primer may be required. PARKER PAINT's First Kote exterior alkyd primer should be topcoated with a finish coating within seven (7) days after application. PARKER PAINT'S First Kote is a recommended primer for use under PARKER PAINT's Flextron, Over All and Flex Glow, and other PARKER PAINT exterior products. NOT RECOMMENDED FOR: Use as a finish coating or as a primer on bare metal, plastics, high-density overlay or pre-coated metal siding, doors, and asphalt or bituminous coating. DO NOT use this primer if the finish coating contains a strong aromatic solvent. Lifting or wrinkling of the finish and primer may occur. SURFACE PREPARATION: Before applying, read and follow all directions and cautions on container label. The moisture content of the substrate to be painted should not exceed 15%, as determined by a moistu~e meter. All surfaces to be primed, old and new, must be sound, clean, dry and free of dust, saw dust, dirt, oils, chalk, mildew, blistered or peeling paint, organic matter, or any other contamination that can affect the paint film. This can be achieved by scraping, sanding, wire brushing, pressure washing, sandblasting, or any other approved method of preparing a substrate for painting. Clean and fill all major cracks, voids, nail and staple holes. On new wood, remove any loose fibers. Repair any moisture problem areas. If a structure is cleaned with a pressure water wash, the structure should be let to dry in good weather for one week before priming. Mold and mildew can be removed by washing a surface with a solution of 6-8 ounces of a non-phosphated detergent, 1 quart bleach in 1 gallon hot water. Let set for 15 to 20 minutes after applying solution, then rinse thoroughly with fresh water. Shrubbery and plants should be watered down and coverd before applying solution. Wear protective eye shields and clothing while using this solution. Let substrate dry thoroughly before priming. Caution should be taken if a flammable product is used for cleaning. For special painting procedures, ask your PARKER PAINT representative for additional instructions. METAL: 1651 Zinc Phosphate Alkyd Primer 1652 Rust proof red Alkyd Primer 1655 White Alkyd Primer 1679 Speed Ori Alkyd Primer APPLICATION: Mix paint thoroughly before using. RECOMMENDED DRY FILM THICKNESS PER COAT: 2.0 mils. WET FILM TO ACHIEVE OFT: 3.4 mils. (Unthinned Material) THEORETICAL COVERAGE AT RECOMMENDED OFT: 430-480 sq. ft. per gal. Coverage will depend on the method of application, porosity, and texture of the surface. Do not apply exterior paint coatings during rain, or in damp, foggy or freezing weather. Anyone or all of these conditions can affect the drying, appearance and durability of a paint coating. First Kote primer must be applied thick enough to thoroughly coat the substrate being primed. This is to provide the best possible shield against any stains permeating through the coatings. In some cases a second coat may be requiredon 303 type plywood siding. A brush application of this coating is recommended for coating the grooves in grooved panels. RECOMMENDED APPLICATION TEMPERATURES AND HUMIDITY: 50-90 F (10-32 C) 50-55% RH Do not apply a paint coating to a hot surface or in the direct sunlight. One or both could cause the coating to blister and/or peel. DRYING TIMES: TACK FREE: 24 hrs. @ 77 F (25 C) RECOAT: 24 hrs. 50-55% RH DRY HARD: 24 hrs. NOTE: See Precautionary Information on back. EQUIPMENT RECOMMENPATIONS: THINNING: No thinning is necessary. If necessary, add no more than 4 fl. oz. of paint thinner per gallon. BRUSH/ROLLER: Use premium quality brushes or rollers. AIRLESS SPRAY: Fluid Pressure 1500-2200 PSI Tip Orifice Size.013 -.021 Filter CLEAN UP: Clean all tools and equipment immediately after use with clean paint thinner. 3003 S. Tacoma Way. PO Box 11047. Tacoma, Washington 98411. (253)4731122. (800)8264308 (continued over)

Page 5 of 5 END OF SECTION