EFC 3600 Frequency converter for higher energy efficiency and improved process control

Similar documents
Frequency Converter Fv vector control converters for universal applications

Frequency Converter Fe Economical converters for universal applications

Frequency converter. Frequency Converter Fe

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

Compact drives IndraDrive Cs

Intelligent Drive Systems, Worldwide Services SK 700E F 3070 GB

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

Rexroth Frequency Converter

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

The new Yaskawa Varispeed G7 Inverter

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

FUJI Inverter. Standard Specifications

General Purpose Drives

This Chapter contains:

Analog amplifier RA. RE Edition: Replaces:

ESR. The Dynamic Solution. Main Characteristics. Applications. ESR Pollmeier GmbH

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 10

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

Frequency Inverters. VF-nC3 VF-S11 VF-FS1 VF-PS1 VF-AS1

Rexroth Frequency Converter Fe

Inverter MICROMASTER 410

S11 Adjustable Speed Drive Engineering Specification

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

General Purpose AC Drives

GB QUICK GUIDE FOR THE CONFIGURATION OF VARIABLE SPEED DRIVES

safety Doc: DPD00714C, Released: vacon 1 ONLY A COMPETENT ELECTRICIAN IS ALLOWED TO CARRY OUT THE ELECTRICAL INSTALLATION! 1.

ADJUSTABLE SPEED DRIVES. AS1 Drive

SX (400V) System configuration

С210/С410 Series Compact design, small appearance and easy to operate

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 15

SX (400 V) System configuration

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

SX (690 V) System configuration

NX Series Inverters. HVAC Pocket Programming Guide

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

VF-nC1 Adjustable Speed Drive Engineering Specification

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

Product description. At a glance. Customer benefits

Fan and Pump AC Inverter

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

vacon nxs robust drive for heavy use

ADJUSTABLE SPEED DRIVES FS1

Meduim Voltage Drives

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

E3 Adjustable Speed Drive Engineering Specification

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Altivar 28 drive Altivar 28 enclosed drive

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1.0HP 350HP V Single & 3 Phase Input

The Drive & Control Company. Frequency Converter. EFC 3610 / EFC 5610 Series. Quick Start Guide R Edition 12

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features

AF91 Adjustable Frequency Drives Series B

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR

AD Series. AC Servo Drive. For the highest requirements in performance and precision

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

Electric amplifier for proportional cartridge throttle valves

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

Operating Instructions

EN 50178, IEC

vacon nx all in one application manual ac drives Phone: Fax: Web: -

TECHNICAL SPECIFICATION INVERTER VEGA DRIVE

NX series Constant and variable torque Variable Speed Drives for induction motors

Medium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

Contents. Safety Information and Precautions Product Information Operation Panel (Keypad & Display) Quick Setup...

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

Single-phase or three phase AC220V (-15% ~ +10%) 50 ~ 60Hz

SKS B2 120 GD 69/11 - MA PB

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

Industrial motor controller for brushed DC motors 24 VDC

AEI800L Avid extreme Liquid Cooled Inverter Module Data Sheet REV 00, March AEI800L Liquid Cooled Inverter Module Data Sheet

Manual Overview...1 2

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

Industrial motor controller for brushed DC motors 12 VDC

Valve amplifier for proportional valves with electrical position feedback

Self contained servo drive CLDP Technical data sheet

vacon 10 ac drives quick guide

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

Frequency inverters DF Vector frequency inverters DV

Multi-purpose Control Application II

ZETADYN 3BF (R-TBA05_08-GB)

Variable frequency drives; 1-/3-phase 230 V; 10.5 A; 2.2 kw; EMC filters; braking transistor

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

Multi-function, Compact Inverters. 3G3MV Series

General Specifications FECA-TE /2010. Phone: Fax: Web:

servo ARS2000 openconcepts

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

SKS B2 140 GD 69/12 U - MA PB

Transcription:

EFC 3600 Frequency converter for higher energy eiciency and improved process control

2 Valuable energy used responsibly Rising energy costs and increasing demands on the environmentally sound products pose major challenges to industry and in particular to mechanical engineers. End-users demand energy-eicient machines and equipment in order to significantly reduce operating costs and CO 2 emissions this is particularly true in the field of drive technology. In this area, Rexroth EFC 3600 frequency converter oers economical and easy to use solutions for various applications in which valuable energy is to be used responsibly.

3 Majority of the consumed electric energy in the industry is still used by electric motors. Only a small proportion of the installed motors however operate with variable speed drives, although this would lead to substantially lower energy consumption and thus would lead to significant cost reductions. Moreover, modern, speed-regulated drives stand for improved process control, lower wear and a more slim facilities design. Rexroth EFC 3600 frequency converters to control the speed contribute greatly to the energy savings required by your customers and also energy conservations mandated by law. They also contribute indirectly to lowering CO 2 emissions. Furthermore, the EFC 3600 satisfies all engineering and usability requirements. Intelligent features, low cost and eort required for installation and a high level of serviceability makes the Rexroth technology an attractive option. EFC 3600 The energy-eicient solution for nearly all sectors: Building-material machines Building technology Environmental and process engineering Food and beverage manufacturing General automation Logistics Machine tools Packaging machines Paper manufacturing and processing Plastics manufacturing and processing machines Textile machines Wood working and processing machines EFC 3600 Applications: Materials handling equipment: assembly lines, roller tables Process engineering: mixers, agitators, centrifuges Pumps, compressors Ventilators, fans

4 Perfect integration in various applications Straightforward assembly, easy installation and usability: EFC 3600 frequency converters meet your engineering needs and the desires of your customers regarding optimum usability both as a whole and right down to the smallest detail. Its universal appeal as an intelligent, cost-eective and compact solution comes from its ability to be used in the widest variety of applications, for example, in pumps, compressors, fans, materials handling equipment, packaging machines and much more. e e The terminal side: plug-in terminal for peripherals EFC 3600 Benefits at a glance Significant energy savings and longer motor service life through a freely definable V/f characteristic, allowing load-dependent adjustment of the voltage-to-frequency characteristic Stepless adjustable pulse frequency provides maximum energy eiciency and minimized motor noise Savings are made on external components thanks to the integrated brake chopper and mains filter Additional peripheral devices are no longer required thanks to the integrated control panel for quick and easy start-up Easy installation thanks to plugable I/O terminals

5 Electrical properties 1 AC (220 V, 0.4-2.2 kw), 3 AC (400 V, 0.4-4 kw) High overload capacity: 150 % for 60 s, 200 % for 1 s High initial torque: 100 % at 1.5 Hz, 150 % at 3 Hz 50 C ambient temperature without derating Integrated brake chopper Integrated mains filter (EN 61800-3 C3) Overvoltage protection Motor temperature monitoring (NTC, PTC) Mechanical properties Can be installed side-by-side to save space Circuit boards are coated to protect them against dirt and damage Plugable I/O terminals Intelligent features Simple program structure and parameter input Harmonized parameters across the entire series Removable control panel with copy function for quick transfer of parameters Clearly displayed 4-digit 7-segment LED indicator Potentiometer to set speed setpoint Fan can be replaced without tools (devices up to 0.75 kw do not have a fan) Integrated PID controller Integrated sequence control system (8 steps) Integrated counter function Digital inputs and outputs Analogue inputs and outputs Modbus or PROFIBUS interface Perfect service Long-term availability of components Fans can be replaced without tools Quick and easy replacement of the device Quick worldwide delivery of spare parts Worldwide repair and on-site servicing c c Removable control panel with memory function for quick transfer of parameters

6 Optimum handling "easy to use" Rexroth technology is designed for easy installation and usability. The integrated control panel includes all what is needed for fast commissioning and simple operation of an EFC 3600. Commissioning is really easy without a PC or another programming device. The copy function of the control panel can be used for configuration of multible inverters with the same or similar parameters. Simple and user-friendly: All parameter values are input using the robust buttons. The 4-digit LED display shows you all the parameters in a clearly arranged manner. The documentation guides you step by step through the setting of parameters and explains the menu structure. The copying function of the removable control panel saves you time when setting parameters for several frequency converters or when replacing a device. The control panel: inputs, functions and indicators 7-segment LED indicator Output frequency Parameter values Error codes Status LED FWD: Motor rotating forwards REV: Motor rotates in reverse Run: Operating mode Function button Next higher menu level Run button For starting the frequency converter Potentiometer For specifying speed setpoint Arrow buttons For selecting parameter values For changing parameter values Stop button For stopping the frequency converter Fault reset Set button For confirming input values

7 EFC 3600 Functions and technical data Function Control Mode V/f Speed regulation range 1 : 50 Start-up torque 100 % at 1.5 Hz; 150 % at 3 Hz Pulse width modulation (PWM) 1 to 15 khz, continuously adjustable in 1 khz steps Brake chopper Integrated standard brake chopper Frequency resolution Digital: 0.01 Hz Analog: maximum frequency x 0.1 % V/f characteristic curve Freely definable Ramps Linear, S-curve Automatic PWM frequency adaptation Load-dependent adaptation of PWM frequency Status message via multi-function output signal In/above/below frequency range, operation, etc. Bus systems Modbus, PROFIBUS (Option) Technical data Typ 0k40-1P2-MDA-7P 0k75-1P2-MDA-7P 1k50-1P2-MDA-7P 2k20-1P2-MDA-7P 0k40-3P4-MDA-7P 0k75-3P4-MDA-7P 1k50-3P4-MDA-7P 2k20-3P4-MDA-7P Performance date Power supply voltage V 1 AC 200 to 240 V (-10 %/+10 %) 3 AC 380 to 480 V (-15 %/+10 %) Supply frequency Hz 50 to 60 (±5 %) Rated motor output kw 0.4 0.75 1.5 2.2 0.4 0.75 1.5 2.2 4 Continous rated current A 2.3 3.9 7.0 9.7 1.2 2.1 3.7 5.1 8.8 Output voltage V 0 V to power supply voltage Output frequency Hz 0 to 400 Overload capacity 200 % for 1 s, each 20 s or 150 % for 60 s, each 10 min Brake Brake chopper Internal Brake resistor External Motor cable length Int. mains filter C3 m 15 Int. mains filter C4 m 30 Mechanical data Size A B C D B B C D D Width A mm 90 95 95 120 95 95 95 120 120 Height B mm 135 145 185 210 145 145 185 210 210 Depth C mm 105 120 125 130 120 120 125 130 130 Mass kg 0.96 1.24 1.61 2.35 1.18 1.26 1.52 2.25 2.36 Ambient conditions Ambient temperature -10 to +50 C without derating Max. installation heigth 1,000 m (max. 4,000 m over sea level with 20 % derating) Relative humidity < 90 % Degrees of protection IP20 4k00-3P4-MDA-7P

8 EFC 3600 Installation space and dimensional drawings Installation situation 150 mm Outlet The perfect installation EFC 3600 frequency converters do not have ventilation openings, which makes it possible to install several devices next to each other with no gap between them. This saves control cabinet space and simplifies cooling. Func Set LOW HIGH Air guide plate Run FWD REV Run Stop Inlet L1 L2 L3 (+) B U V W 150 mm Size A, B, C Size D A C A C B B LOW HIGH Func Run Set Stop Run FWD REV L1 L2 L3 (+) B U V W

9 9 EFC 3600 Block diagram 3 AC 380 to 480 V (50/60 Hz) L1 Mains switch L2 L3 (+) B External brake resistor 1 AC 200 to 240 V (50/60 Hz) L N Mains switch L1 L2 L3 U V W M 3 Brake chopper Digital multi-function input 1 X1 Digital multi-function input 2 X2 Digital multi-function input 3 X3 Digital multi-function input 4 X4 Digital multi-function input 5 X5 Shared connection for digital signals SC SW + (NPN/PNP) switch FM1 OUT1 CME Analog multi-function output 0 to 10 V Open collector output +10 V Tb Analog multifunction inputs 0 to 10 V 4 to 20 ma VR1 +I Tc Ta Relay output GND Serial RS485 interface 6 1 1, 5, 6: not used 2: GND 3: RS485 4: RS485+ Power supply Signal supply Shielded cables are required

Bosch Rexroth AG P.O. Box 13 57 97803 Lohr, Germany Bgm.-Dr.-Nebel-Str. 2 97816 Lohr, Germany Phone + 49 9352-18-0 Fax + 49 9352-18-8400 www.boschrexroth.com Find your local contact person here: www.boschrexroth.com/contact R999000207 (2012-12) Bosch Rexroth AG 2012 Subject to revisions! The data specified above only serve to describe the product. As our products are constantly being further developed, no statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.