SECTION IDENTIFYING DEVICES

Similar documents
The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION SIGNAGE

A. Submit properly identified manufacturer's literature before starting work.

SECTION IDENTIFYING DEVICES

*********************************************************************************************************

SECTION IDENTIFICATION SIGNS. A. Plastic Signs, raised character, tactile, room identification, exit door signs, and non-tactile signs.

A. Submit manufacturer's technical data and installation for each type of sign required.

Americans with Disabilities Act (ADA) Federal Guidelines

SECTION NON-ILLUMINATED INTERIOR DISPLAY SYSTEM

SECTION INTERIOR SIGNAGE

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines

DETAILED STILE AND RAIL WOOD DOOR SPECIFICATION

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2

A. Interior and exterior non-illuminated tactile building signs including Braille.

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

INTERIOR SIGNAGE MANUAL

A. Product Data: For each electrical identification product indicated.

SECTION INTERIOR SIGNAGE

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

1.1. Any deviance from the following requirements must be approved during design by WVU Facilities Management.

SECTION ELECTRICAL IDENTIFICATION

BUILDING SIGN PROGRAM JULY 2012

SECTION BULLET- RESISTANT DOORS

Advisory Raised Characters. Signs that are designed to be read by touch should not have sharp or abrasive edges.

APPENDIX 6. SIGNAGE TYPES: Signage as manufactured by KROY Sign Systems, N. Hayden Road, Scottsdale AZ 85260

Music Area Casework General 1.01 Summary Related Sections Definitions Qualifications and Quality Assurance

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO.

B. Samples: For color, letter style, and graphic representation required for each identification material and device.

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

Merrick Pet Care New Distribution Center Hereford, Texas

SECTION FINISH HARDWARE

50948-RHN Putney. 14 Dec This document includes: N14 General internal signage systems. Code Section Revision Dated

UNIFIED FACILITIES GUIDE SPECIFICATIONS

ETCHED PLAQUES by Matthews International

Summary of Modifications/Changes in this Update

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

SECTION FASCIA INTERIOR FRAMED SIGNS & DIRECTORIES

Product Guide Specification

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

SECTION IDENTIFICATION FOR ELECTRONIC SAFETY AND SECURITY

Piping & Equipment Identification

Product Guide Specification

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

Copyright 2017 AIA MasterSpec Premium 05/17 PRODUCT MASTERSPEC LICENSED BY ARCOM TO WEREVER PRODUCTS, INC.

SPARTAN DAY CAMP 4814 FREEDOM RING RD

CENTRAL MICHIGAN UNIVERSITY DESIGN STANDARD FOR INTERIOR CAMPUS SIGNAGE - JANUARY 23, 2017

A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable.

.2 Accompany all submissions with a transmittal letter, in duplicate, containing:.4 Specification Section number for each submittal

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT

BUILDING SIGN PROGRAM SEPTEMBER 2016

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

SECTION CUSTOM CASEWORK

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

C. Installation shall be by experienced carpenters. Coordinate with plumbing and electrical contractors.

Product Guide Specification For Nonrated & 20-Minute Rated Doors

A. It is preferred that all submittals to be submitted electronically in PDF format.

SECTION HOLLOW METAL DOORS AND FRAMES

INDEX OF SPECIFICATIONS SECTION F SPECIAL CONDITIONS DIVISION 1 - GENERAL REQUIREMENTS:

CITY OF RICHMOND Notice of Public Opening. Contract: Richmond Speed Skating Oval Interior/ Exterior Signage Package

SUBMITTAL REQUIREMENTS FOR COMMERCIAL SIGNAGE PROJECTS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

SECTION MANUFACTURED CASEWORK

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

SECTION FINISH CARPENTRY PART 1 GENERAL. 1.1 SECTION INCLUDES A. Interior Finish Carpentry Work: 1. Refer to schedule at end of Section.

Design and Construction Standards SECTION ATHLETIC LOCKERS

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

2016 CALIFORNIA BUILDING CODE - SECTION 11B-213 & DIVISION 6 GENERAL REQUIREMENTS FOR TOILET & BATHING FACILITIES

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

CHAPTER 5 ARCHITECTURE

1. ASME A Scheme for the Identification of Piping Systems.

SECTION IDENTIFICATION OF HVAC PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

SECTION FRAMELESS GLASS SLIDING BI-FOLD SHOWER DOOR HARDWARE

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

UNIFIED FACILITIES GUIDE SPECIFICATIONS

WALKS AND SIDEWALKS REQUIREMENTS:

Mohawk Sign 2010 ARCHITECTURAL GRAPHICS CATALOG. A Sign of Quality Since 1946

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION LAP SIDING. A. Fiber cement lap siding, panels, single, trim, fascia, moulding and accessories.

SECTION MECHANICAL IDENTIFICATION

CHAPTER TWO Fire Lanes & Fire Access

B. Sequencing: Schedule installation to keep sheathing exposure to UV within the manufacturer s recommended limits.

Series 9000 Vinyl Fixed Window

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

PROJECT LOCATION SECTION PREFINISHED STEEL DOOR FRAMES

SECTION WOOD AND PLASTIC DOORS. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION PRE-MANUFACTURED CABINETS

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION PLAQUE, SERVICE AWARD PUBLICATION

PHOTOPOLYMER MATERIAL

PHOTOPOLYMER BRAILLE RASTER BRAILLE MOLDED BRAILLE QUICK SHIP ADA BRAILLE SIGNS. Photopolymer sign panel in a variety of thicknesses.

w i t h Yo u r U n i v ersal Laser System

COVER SHEET A0.1 A0.1 COVER SHEET A1.1 FLOOR PLANS - FOUNDATION & MAIN LEVEL A1.2 FLOOR PLANS - UPPER LEVEL & ROOF A3.1 SECTIONS & INTERIOR ELEVATIONS

SECTION MECHANICAL IDENTIFICATION

Transcription:

PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 10441 IDENTIFYING DEVICES A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1 specification section, apply to work of this section. 1.2 SECTION INCLUDES: A. Tactile/raised letter plastic signs. B. Individual plastic characters signs. C. Signs of silk-screened characters on plastic. D. Required sign type: 1. Interior room, space and area ID signs. 2. International symbols of accessibility for accessible spaces and exits. 3. Accessible routes 4. Tactile exit signs 5. Hazard and safety signs 6. Evacuation plans 1.3 REFERENCES A. ANSI A117.1 - Specifications for Making Buildings and Facilities Accessible To and Usable By Physically Handicapped People B. Florida Building Code, Chapter 11 and Section 423.14.2 C. NFPA 101: 7.10.1.3. 1.4 SUBMITTALS A. Submit shop drawings under provisions of Section 01300. B. Shop Drawings: Indicate sign styles, lettering font, foreground and background colors, locations, overall dimensions of each sign and anchorage. C. Sign Schedule: Provide complete interior and exterior sign schedule showing sign type, location, and verb age. D. Samples: Submit two sample signs in size illustrating type, style, letter font and colors specified method of attachment. E. Manufacturer's Installation Instructions: Included installation template and attached devices. F. Colors: Colors shall be as selected by the Architect. 1.5 QUALIFICATIONS A. Manufacturer: Company specializing in manufacturing the products specified in this section with minimum three years documented experience. 1.6 REGULATORY REQUIREMENTS Architect s Project Number 10441-1 of 5 Identifying Devices

A. Conform to applicable codes for requirements for the physically handicapped, safety and egress. 1.7 DELIVERY, STORAGE, AND HANDLING A. Deliver, store, protect and handle products to site under provisions of Section 01600. B. Package signs, labeled in name groups. C. Store adhesive attachment tape at ambient room temperatures. 1.8 ENVIRONMENTAL REQUIREMENTS A. Do not install signs when ambient temperature is lower than recommended by manufacturer. B. Maintain this minimum temperature during and after installation of signs. PART 2 PRODUCTS 2.1 FLORIDA AMERICANS WITH DISABILITIES ACT REQUIREMENTS A. Manufacturer shall conform to tactile, Braille, letter size, and other requirements as required by Florida Accessibility Code for Building Construction and ANSI A117.1. ADA requirements supersede technical specifications in this Section. 2.2 MANUFACTURER A. Identifying devices shall be as manufactured by Andco Industries Corp., or approved equal. B. Products of the following manufacturers are acceptable providing their products equal or exceed the quality specified; and they can provide signs of the type, size, finish, letter style, and arrangement required. 1. ASI Sign Systems, Indianapolis, Indiana 2. Best Mfg., Montrose, Colorado 3. Baron Sign Company, Lake Park, Florida 4. Liberty Sign, Jupiter, Florida 2.3 BUILDING INTERIOR SIGNAGE A. Capacity signs for all rooms with a capacity of 50 persons or more as shown on the drawings. 1. Furnish and install signage, 3 inch high by length required, reading "MAXIMUM CAPACITY'. Allow for 3 digits maximum after "maximum capacity", copy as shown on the drawings. 2. Material shall be 1/8" clear matte acrylic stock with subsurface printed dark gray ground and white copy. Signs shall have 3/8" radius corners. 3. Mounting shall be with non-removable oval head screws using shields where mounted on masonry surfaces. Mount at locations as directed by Architect. 4. Graphic Process: Raised letters and Braille shall be surface applied to the sign face or engraved as an integral part of the sign face. 5. Letters: Letters and numbers shall have width to height ratio between 3:5 and 1:1 and 1/32" upper case sans serif font type with Grade 2 Braille. Raised characters shall be 5/8" high minimum and 2" high maximum. Pictograms shall be accompanied by the equivalent verbal description placed directly below the pictogram. Architect s Project Number 10441-2 of 5 Identifying Devices

6. Characters and backgrounds must be eggshell, matte or other non-glaze surface. B. Toilet Room Handicapped Signs 1. Furnish and install one sign depicting National Handicapped Symbol (wheelchair) at each toilet room, equipped with facilities for the handicapped. Size shall be 6" by 6" with 3/8 inch radius corners. 2. Material: 1/8" thick matte acrylic plastic with all edges eased. 3. Graphic Process: Raised letters and Braille shall be formed as an integral part of the sign face or surface applied to the sign face. 4. Colors: Letters and background colors as selected by Architect from manufacturer's 5. Letters: Letters and numbers shall have width to height ratio between 3:5 and 1:1 and a 1/32" upper case sans serif font type with Grade 2 Braille. Raised characters shall be 2 inches high. Pictograms shall be accompanied by the equivalent verbal description placed directly below the pictogram. 6. Mounting shall be with non-removable oval head screws at locations directed by Architect, 5 foot above finish floor to centerline of sign. 7. Characters and backgrounds must be eggshell, matte or other non-glaze surface. C. Room Name and Number Signs 1. Separate signs for each room name and room number is required. 3 inch high by 10" minimum width for signs, longer where nomenclature demands. 3 inch high by 4 inch minimum for 4 digit numbers and letters, and longer where required. Provide 3/8" radius corners. 2. Mounting: Non-removable oval head screws, using rawl plugs where mounted on masonry. 3. Number shall be to the left of room name and contiguous to, mounted as directed by Architect. Verify exact location with Architect. 4. All spaces listed in Finish Schedule plus if more than one door is to a space, additional signs will be required one by number of doors to space. 5. Material: 1/8" thick matte acrylic plastic with all edges eased. 6. Graphic Process: Raised letters and Braille shall be formed as an integral part of the sign face or surface applied to the sign face. 7. Colors: Letters and background colors as selected by Architect from manufacturer's 8. Letters: Letters and numbers shall have width to height ratio between 3:5 and 1:1 and a 1/32" upper case sans serif font type with Grade 2 Braille. 9. Raised characters shall be 2" high. Pictograms shall be accompanied by the equivalent verbal description placed directly below the pictogram. 10. Characters and backgrounds must be eggshell, matte or other non-glaze surface. D. Storage Signs 1. Provide and install at mechanical and electrical rooms a sign mounted on the door to read as follows: "COMBUSTIBLE STORAGE NOT PERMITTED" 2. Signs shall be matte acrylic plastic, red background with white letters 3 high by width needed for copy and Braille, with 3/8" radius corners. 3. Mount on doors with non-removable oval head screws. Verify number signs required. 4. Graphic Process: Raised letters and Braille shall be formed as an integral part of sign face. 5. Letters: Letters and numbers shall have width to height ratio between 3:5 and 1:1 and a Architect s Project Number 10441-3 of 5 Identifying Devices

1/32" upper case sans serif type with Grade 2 Braille. Raised characters shall be 2" high. Pictograms shall be accompanied by the equivalent verbal description placed directly below the pictogram. 6. Characters and backgrounds must be eggshell, matte or other non-glaze surface. E. Fire Extinguisher, Not an Exit and Pull Station Sign 1. Copy to read: Not An Exit, "Fire Pull Station Inside", and "Fire Extinguisher Inside" 2. Red letters, same material, size and mounting in Article 2. 3 C., Interior room name and number signs. 3. Braille sign not required for fire extinguisher. F. Stair Signs 1. Provide separate signs for each stairway as required, 4" high by 12" width with 1/8" radius corners. 2. Mounting: Non-removable oval head screws, using rawl plugs where mounted on masonry. 3. Material: 1/8" thick matte acrylic plastic with all edges eased. 4. Graphic Process: Raised letters and Braille shall be formed as an integral part of the sign face. 5. Colors: Letters and background colors as selected by Architect from manufacturer's 6. Letters: Letters and numbers shall have width to height ratio between 3:5 and 1:1 and a 1/32" upper case sans serif bold type with Grade 2 Braille. 7. Raised characters shall be 5/8" high minimum and 2" high maximum. Pictograms shall be accompanied by the equivalent verbal description placed directly below the pictogram. 8. Characters and backgrounds must be eggshell, matte or other non-glaze surface. G. Evacuation Plan 1. Provide frame for a graphic floor plan in each student occupied room. Size to be 9" high by 12" in width. Provide a clear removable plastic cover over each sign. Sign cover will only be removable using a tool. 2. Mounting: Mounting: Non-removable oval head screws, using rawl plugs where mounted on masonry. Plan to be supplied by the Architect upon request by the Contractor. 3. Frame Material: Matte acrylic plastic with all edges eased. 2.4 BUILDING EXTERIOR SIGNAGE A. Emergency Access Opening 1. Provide and install at designated emergency access openings a sign mounted on the door to read as follows: "EMERGENCY ACCESS OPENING." 2. Signs shall be non-corrosive, 1/8 three ply laminate, UV inhibitors, non-glare surface, white background with red letters 3 high by width needed for copy. 3. Mount on doors with non-removable oval head stainless steel screws. Verify number of signs required. 4. Graphic Process: Raised letters shall be formed as an integral part of the sign face. 5. Letters: Letters shall have width to height ratio between 3:5 and 1:1 and a stroke width to height ratio between 1:5 and 1:10. Letters shall be raised 1/32", upper case, and sans serif type. 6. Background must be eggshell, matte or other non-glare surface. PART 3 EXECUTION Architect s Project Number 10441-4 of 5 Identifying Devices

3.1 INSTALLATION: A. Install all signs in strict accordance with manufacturer's instructions and FADA requirements. Room signs to be mounted 60" to center above finish floor on walls adjacent to the latch side of any door opening. 3.2 CLEANING: A. After installation, all exposed surfaces shall be thoroughly cleaned and all damaged material shall be restored to its original condition or replaced with new material. 3.3 WARRANTY: A. This Contractor shall fully guarantee all materials and labor under this section for a period of one (1) year from date of final acceptance of the building against all defects in both workmanship and materials and he shall promptly correct and/or replace such faulty work if so notified. END OF SECTION Architect s Project Number 10441-5 of 5 Identifying Devices