ENGLISH. Stock N o Stability indicator Light on/ Dark. on optional Output can be

Similar documents
High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Solid-state Timer H3DS

Capacitive Proximity Sensor

Vert-X 28HD - 24V / V. Applications Harvester Public transport Construction machines

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

System protection by Vibration monitoring

Remote Sensor Amplifier Terminal

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Vert-X 31E 24V. Applications Concrete pump Access control system Fork lift

Vert-X 27E - 24V / 4-20mA. Applications Harvesting machine Fork lift Hydraulic pump

HPX-ET Series. Gang-mounted Distributed Remote Cluster Type Fiber Optic Photoelectric Sensors. Specifications. click

Vert-X 31E - 5V / % Ub. Applications Concrete pump Access control system Fork lift

Vert-X 27E - 5V / % Ub. Applications Harvesting machine Fork lift Hydraulic pump

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

Vert-X 37E - 5V / % Ub. Applications Agricultural machines Construction machines Forest machines Special purpose vehicles

Vert-X 22E - 24V / 4-20mA. Applications Wind vanes Valve control Level sensor Special purpose vehicles

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Vert-X 27E - 24V / SPI. Applications Harvesting machine Fork lift Hydraulic pump

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Remote Sensor Amplifier Terminal

Vert-X 22E - 5V / % Ub. Applications Wind vanes Valve control Level sensor Special purpose vehicles

Vert-X 31E - 24V / SPI. Applications Concrete pump Access control system Fork lift

Multifunctional counter tico 772/773/774

Vert-X 37-5V. Applications Agricultural machines Construction machines Forest machines Special purpose vehicles

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

LED Displacement Sensor

Electronic timer CT-TGD.22

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

Vert-X 16. Applications Servodrives Dancer arm Operating table

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

Vert-X 22E - 5V / PWM. Applications Wind vanes Valve control Level sensor Special purpose vehicles

Energy Management Energy Meter GM3D

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67g environment resistance

NOVOHALL Rotary Sensor touchless technology transmissive. Series RFC4800 analog

PI2794. Flush pressure sensor with display. 1 alphanumeric display 4-digit 2 status LEDs 3 programming button. Made in Germany

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Proximity Sensor Terminology

Power supply CP-D 24/1.3

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

Digital Fiber-Optic Switches

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Multi-voltage Multi-function. Wiring diagram (without control signal)

Triple Beam Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Energy Management Energy Meter Type EM21 72R Retro-Fit

Long Range Metal Body Sensor

Amplifier-separated Manual Sensitivity Setting Photoelectric Sensor

Opaque materials of Min. Ø60mm. Hysteresis - Max. 10% at rated setting distance

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Rotary Position Technology Incremental Encoders

PROXIMITY SENSOR TERMINOLOGY

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

General-Purpose Photoelectric Sensors with Self-Contained Amplifier

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Rotary Measurement Technology Incremental Encoders

Solid-state Twin Timer

Triple Beam Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in

Temperature Transmitters - DIN Rail Mounted

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Twin adjuster enables delicate sensitivity setting

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

SENSORS S2Z SERIES MAXI SENSORS CARATTERISTICHE APPLICATIONS HIGHLIGHTS

83 Series - Modular timers 16 A. Features

OPTITEMP TT 20 Technical Datasheet

E2Q5. Square Proximity Sensor. Long Distance Square Inductive Proximity Sensor. Ordering Information

Triple Beam Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

WESAN WP E ELECTRONIC METER WOLTMAN

For Immediate Delivery call KMParts.com at (866)

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

CD4 Series with linear image sensor and electronic shutter provides accurate measurement.

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

E2S World's Smallest Square Sensor with Built-in Amplifier

Photoelectric Sensors XUV Sensors with Separate Optical Heads

Inductive Standard Displacement Transducers

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

08/07/2015

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Distance Sensors BOD 26K.... with optional Master-Slave-Mode

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Zelio Control Measurement Relays

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Transcription:

Product Datasheet Optical Fiber Amplifier Stock N o. 8967305 Feature Description Sensing distance can be set by key (Self learning) Stability indicator Light on/ Dark on optional Output can be set, NO delay or OFFF delay 100ms Reverse polarity protection, shock protection, overload protection and short-circuit protection

Features Limiting voltage Fluctuation voltage Current consumption Leak current Outpu delay Outpu mode Power Supply Protection Outpu protection Voltage drop Indicator display Rated load current Min load current Hysteresis Repeated accuracy Efficient operation distance Distance regulation Response time Temperature drift Ambient temperature Light source EMC-ESD EMC-Burst EMC-HF Dielectric property Anti-vibration Anti-shock Protection degree Connection Housing material DC10 30V <10% <40mA <0.1mA There are two ways for setting: Norm; Off delay 100ms NPN+PNP;L.ON/D.ON Dial switch optional Polarity protection, shock protection Overload protection, short-circuit protection <2.5V(@ILOAD=100mA) ) Output indicator, power indicator, stability indicator, setting indicator Short - circuit /overload indicator, 100mA 1mA 3%...20% <5% 1~80mm (90% reflective rate, 100*100mm white card, with fiber cable PRC-610 for test) Key <1ms <10% 0 ~50 Visible red light ±4kVV CD/±8kV AD (IEC61000-4-2) ±2kVV 5kHz (IEC61000-4-4) 3V/m (IEC61000-4-3)/ 3V (IEC61000-4-6) <0.2mA (500VAC,60s) Amplitude:1mm;Frequency:10~55Hz;Sweep frequency cycle: 5min Shock (Impulse) wave shape: Half sine; Peak speed: 30gn; Pulse duration: 11ms IP54 2M PVC cable PC+ +ABS

Operating instructions Control panel symbol Definitionn of key and dial switch Function of SET key: Sensing distance setting 1. Put target object in the distance setting position; 2. Press SET key for 2~5 seconds, then release, red and green LED will flicker mutually with 2Hz frequency, then it will enter setting mode; 3. If the sensor enters working mode after red and green LED flickering 3 times at the same time with 2Hz frequency, it means that the setting is successful; 4. If red and green LED flicker mutually with 8Hz frequency, it means that the receiving signal is not strong and the setting failed. Based on this condition, please take corresponding actions according to below failure reasons, and repeat 1.2.steps once failures removed; Failure reason The size of sensing face is too small The distance is too far The reflective rate of target object is too low Measures Increase the size of sensing face Reduce the distance between the target object and optical fiber head Increase the reflective rate of target object NORM/OFF DLY 100ms Function definition NORM: Output is without delay OFF DLY 100ms:Off delay 100ms L.ON/D.ONN Definitionn L.ON: The output is on wheree there is light signal D.ON: The output is on wheree there is no light signal

LED indicator Red LED(OUT): Outpu indicator, short-circuit indicator; Output indicator: Red LED and output relations are as shown in below figure; Short-circuit indicator: When output is on and short-circuit appears, red LED will flicker with 4Hz frequency; Green LED (POWER): Power indicator, signal stability indicator; Signal stability indicator: When there is stable light signal or no light signal, the indicator is on; When light signal is unstable, green LED will flicker with 2Hz frequency; Power indicator: Green LED is always on or flickers with 2Hz frequency, which means that the power is stable. Attentions When red LED flickers rapidly, it means that the load current is exceeded or there appears short -circuit, so please check the load and reduce the load current. Installation instructionss Optical fiber installation Unscrew the fixed cover (As shown below), insert the fiber cable into corresponding fixed hole, and reversely screw the fixed cover.

* To ensure normal use of the product, please embed the fiber cable into the bottom of fixed Connection diagram Use of cutter Optical fiber cutter can cut the fiber to be actual required length. 1. Put fiber into corresponding hole of cutter and reserve the required length in advance. 2. Press the cutter blade with high speed, which can cut the fiber successfully. * To ensure the fiber performance, every cutter hole can be used only once. * To ensure the fiber performance, try to cut the fiber successfully at a time, please avoid cutting the same point for many times. Installation and removal of amplifier Installation of amplifier 1. Press the A-end of the amplifier into DIN guide rail or mounting rack; 2. Press the B-end of amplifier into DIN guide rail or mounting rack. The sequence of A and B can't be reversed during installation, if installed the backward, the installation strength will be reduced.

Removal of amplifier Press the amplifier. Installed side by side amplifier to direction C, and uplift the imbedded fiber to direction D, which can remove the 1. Install the amplifier on DIN rail, one amplifier one time. 2. Push the permanent seat to the end, so that the amplifier can be fixed. (Permanent seat is included in the expansion module, pleasee be sure to use it.) Electrical wiring diagram

Dimension (mm)