Differential pressure sensors

Similar documents
Outside Temperature Sensors

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Room Sensors. for relative humidity and temperature

Room sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Huba Control FEINE MESSIDEEN FÜR DRUCK UND STRÖMUNG FOR FINE PRESSURE AND FLOW MEASUREMENT LA FINESSE DES MESURES DE PRESSION ET DE DEBIT

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Room Temperature Controllers. for heating and cooling systems

Universal Controller

QPM Series Indoor Air Quality Duct Sensors

Electronic Step Controller

US2, US4, US6 Electronic step controllers

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke

Room Temperature Sensors

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

Electromotoric actuators

CP-T range Product group picture

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Electronic Thermostat TE-1 Version according to EN

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Room air quality sensors

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Zelio Control Measurement Relays

LINAX 4000L Continuous-line recorder

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

CP-T range Benefits and advantages

DPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

Power amplifier for thermic valve actuators

Electromotoric actuators for stroke valves

DATA SHEET Selectable AC transducer TAS-311DG

SALES SERVICE +358 (0)

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

Type CP-S, CP-C & CP-A Switch mode

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

s Climatix extension module 26 I/Os POL985.00/XXX

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

When ordering, specify quantity, product number and description.

Power supply CP-E 24/0.75

Miniature resistance thermometer Model TR33, thread-mounted

Analogue Temperature Transmitter

Power supply CP-E 24/2.5

CP-E range Benefits and advantages

MINI-PS AC/24DC/1.3

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Power supply CP-E 24/2.5

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Hygro-ThermoTransmitter-compact xxx

Extension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..

Flush pressure transmitter For viscous and solids-containing media Model S-11

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

Power supply CP-D 24/4.2 Primary switch mode power supply

Accessories. Accessories

GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Rotary actuators for ball valves

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

High-precision process calibrator Model CED7000

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Electromotoric actuators for valves

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

DP2500 DP0100 DP0250 Differential Pressure Transmitter

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

JUMO Wtrans Receiver with Wireless Data Transmission

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

QUINT-PS/ 3AC/24DC/10

Power supply CP-D 24/1.3

DP2500 DP0100 DP0250 Differential Pressure Transmitter

Power supply CP-E 24/20.0

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Universal signal transducer UKU

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

QUINT-PS-24DC/24DC/10

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

EC centrifugal fan - RadiCal

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

Transcription:

1 912 1912P02 QBM64/ 1912P01 QBM63/ Differential pressure sensors for air and non-aggressive gases, with a diaphragm sensing element QBM63/ QBM64/ With choice of pressure-linear or extracting-the-root characteristic and a d j u s t a b l e pressure measuring range (nominal volumetric flow V n ) Operating voltage AC 24 V, output signal DC 010 V Use For very demanding requirements as regards accuracy and quality in the field of ventilating, air conditioning and heating To acquire the differential pressure of air or nonaggressive gases Typical fields of application: chemical industry (laboratories and production) in industrial environments (risk of contamination) hospitals (eg in the operating theatre) The differential pressure detectors are used: to measure over- or underpressure in air ducts in relation to the ambient presure to measure pressure differentials between different rooms to acquire variable air volumes in VAV plants on the supply and extract air side to monitor filters and to control fans especially on applications that demand: great accuracy very fast response times (monitoring of fans) resistance to contamination CM1N1912E 15012001 Siemens Building Technologies Landis & Staefa Division

Type summary Without indiaction With indication Accessories (not included in standard delivery) Type Measuring range reference Standard Limit value (adjustable) Overload range QBM63/100 0 100 Pa 40 100 Pa ± 4000 Pa QBM63/250 0 250 Pa 100 250 Pa ± 4000 Pa QBM63/500 0 500 Pa 200 500 Pa ± 20000 Pa QBM63/3000 03000 Pa 12003000 Pa ± 20000 Pa Type Measuring range reference Standard Limit value (adjustable) Overload range QBM64/100 0 100 Pa 40 100 Pa ± 4000 Pa QBM64/250 0 250 Pa 100 250 Pa ± 4000 Pa QBM64/500 0 500 Pa 200 500 Pa ± 20000 Pa QBM64/3000 1) 03000 Pa 12003000 Pa ± 20000 Pa 1) Value displayed x 10 = measured value Name Type reference/part no Mounting kit (for tubing connection to air duct) 4 669 1975 0 Connecting tube (4 dia x 15 x 2000 mm) 4 482 2525 0 Protective casing (IP 55) ARG62 Ordering When ordering, please give name and type reference, for example: differential pressure sensor QBM63/250 Accessories must be ordered separately, with name and type reference or order number Equipment combinations Any systems or devices that are capable of acquiring and handling the sensor s DC 010 V output signal Mode of operation The sensor acquires the differential pressure with the help of a silicon diaphragm The deflection of the diaphragm is sensed and converted to an electric signal Potentiometer V n is used to match the pressure measuring range on an individual basis The sensor s electronics generate either a pressure-linear or an extracting-the-root output signal (selectable) The measured value is delivered by the sensor as an analog DC 010 V output signal Mechanical design The sensor consists of a two-sectional plastic casing The base carries the printed circuit board with the electronic components, sensing element, terminal strip and potentiometer V n The tubing connections of the sensing element, terminal strip, selector for the characteristic and potentiometer V n are accessible from outside 2/6 Landis & Staefa Division 15012001

1 2 5 1912Z01 3 4 Legend 1 Slide switch, to select the pressure-linear or extracting-the-root characteristic; factory-setting: pressure-linear 2 Potentiometer, to set the measuring range (nominal volumetric flow); factory and calibration position: fully clockwise 3 Nipple for tubing connection " " 4 Nipple for tubing connection "+" 5 Digital display for sensor signal in Pa (only with the QBM64/) A mechanism for fitting the sensor to a standard mounting rail and a baseplate for wall mounting are located at the rear The sensor snaps on the base The top part carries the type field and the connection diagram The cover of the sensor snaps on the base It carries the type plate and the wiring diagram Engineering notes The transformer used must be suitable for safety extra low voltage (SELV) It must have separate windings and be suited for 100 % duty It must be sized and fused in compliance with local safety regulations The maximum permissible line lengths should be observed Where a higher level of protection is required (splash water, terminal cover), the protective casing ARG62 (IP55) should be used Fitting notes Normally, the sensor is fitted directly on the air duct, where it can be secured to a DIN mounting rail, or directly to a vertical or horizontal surface Permitted mounting positions Unpermitted mounting positions (any position where the diaphragm (any position where the diaphragm is vertical) is horizontal) 1912Z02 360 The higher pressure must be connected to "+" and the lower to " The sensor is supplied with installation instructions Landis & Staefa Division 15012001 3/6

Technical data Operating voltage (SELV) AC 24 V ±20 % Frequency 50 or 60 Hz Power consumption 1 VA Output signal DC 010 V, ±1 ma Lowest voltage level DC 0 V Perm line lengths Copper cable 05 mm dia 15 m Copper cable 10 mm 2 60 m Copper cable 1,5 mm 2 90 m Copper cable 25 mm 2 150 m Connection terminals for 2 x 15 mm 2 or 1 x 25 mm 2 Pressure ranges refer to "Type summary" Accuracy at 25 C and in mandatory mounting positions With linear characteristic ±1 % of standard pressure (0100 % of pressure range) measuring range With extracting-the-root characteristic ±2 % of standard pressure (2100 % of pressure range measuring range) Display (only with QBM64/) Range of display in Pa standard pressure measuring range Accuracy < ±2 digits Hysteresis and repetition ± 05 % Temperature dependancy < ±01 %/K Position dependancy in unpermitted mounting position ±15 Pa Time constant <1 s Warming-up time 10 s Pressure amplification 125 (Volumetric flow amplification 116) Ambient conditions Operation to IEC 721-3-3 class 3K5 Temperature (ambient and medium) QBM63/ 10+50 C QBM64/ 050 C Humidity 595 % rh Transportation to IEC 721-3-2 class 2K3 Temperature 25+70 C Humidity <95 % rh Mechanical ambient conditions class 2M2 Electromagnetic compatibility Emissions EN 50 081-1 Immunity EN 50 082-1 conformance to EMC directive 89/336/EWG Degree of protection of casing IP 20 to EN 60 529 With the ARG62 IP 55 to EN 60 529 Insulation class III to EN 60 730 Weight approx 01 kg 4/6 Landis & Staefa Division 15012001

Connection terminals M B1 G 1912G01 G, M Operating voltage AC 24 V (SELV) G System potential M System neutral, measuring neutral B1 Measuring signal DC 010 V Landis & Staefa Division 15012001 5/6

Dimensions (in mm) QBM63/, QBM64 15,6 36 ø 4,8 11,5 EN 50 022-35 x 7,5 4 90 35 31,5 49,5 78 45 37,5 10 3,3 1912M03 Drilling plan ARG62 74 35 50 135 10 R93 IP55 10 26 1912M04 97 95 4 Drilling plan 6/6 2000 Siemens Building Technologies Ltd Landis & Staefa Division 15012001