in Control When It Counts LED Indicators Mounting Bracket Meter Seal Mounting Brackets ½ seal tight or ¾ NPT

Similar documents
Beyond AMI. We Put You in Control When It Counts

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

Power Processor - Series 700F 10KVA to 150KVA

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Technical Data Sheet. x1000. kwh R Y B

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

Level Lance Model 5100

SECTION AUTOMATIC TRANSFER SWITCH

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

Technical Data Sheet

21R14A Receiver 14 Control/1 Alarm/1 Safety relays 120 VAC Power Supply

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

SUGGESTED SPECIFICATION DUAL OPERATOR OPEN TRANSITION AUTOMATIC TRANSFER SWITCH WITH RPTCS MICROPROCESSOR CONTROL

Digital Multifunction Instrument - Rish Master 3440

VARIABLE FREQUENCY DRIVE SPECIFICATION

Kotron Sentinel Model 804 RF Level Transmitter

1 INTRODUCTION ORDER CODE / INFORMATION

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Kotron Sentinel Model 804 RF Level Transmitter

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

RCF 3.4. Portable Traffic Signal - Technical Specifications. North America Traffic Inc REV#

SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE

BATCHMATE 1500 Batch Control Computer Technical Bulletin

Signet 9950 Dual Channel Transmitter

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

Data Sheet. RISH Master Record %THD

Signet 9950 Dual Channel Transmitter

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Track Circuit Systems Products

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

NT240 TIMER. PROGRAMMABLE TIMER INSTRUCTIONS MANUAL V20x G TIMER OUTPUTS INTRODUCTION SPECIFICATIONS AUXILIARY SUPPLY OUTPUT INSTALLATION TIMER INPUTS

TOSHIBA International Corp

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

Wireless Temp/Setpoint & Override Room Transmitter

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

SECTION WIRELESS CLOCK/TONE GENERATOR SYSTEM

Signet 9900 Transmitter

LAUREL ELECTRONICS, INC.

SECTION GPS WIRELESS CLOCK SYSTEMS

Protective Relays Digitrip 3000

Power-Sure 700. Technical Data TD158001EN. Contents

AMU-214 Auxiliary Monitor Unit Operations Manual

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

ADJUSTABLE SPEED DRIVES. AS1 Drive

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1

SECTION 16496G CONTACTOR BASED AUTOMATIC TRANSFER SWITCHES LOW VOLTAGE

Toro OSMAC RDR Field Satellite Electric Actuation Models Installation Instructions

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Application: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary

DOBLE F6150e TECHNICAL SPECIFICATIONS

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Operation Manual January Opticom Infrared System. 700 Series Emitters Detectors Phase Selectors Discriminators Accessories

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev TA April 2009.

AMIK 200 / 201 Technical Data Sheet

PowerFlex 400 AC Drive Guide Specification

Description of Changes ADDENDUM NO. 7

DOBLE F6150SV TECHNICAL SPECIFICATIONS

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

Howard Smart Transformer Specification Guide

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

ROAM System Specification Guideline Division 16520

BE1-81O/U DIGITAL FREQUENCY RELAY FEATURES

PACSystems* RX3i IC695MDL765

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

NetSure ITM. Contents 1. Site Planning Data 2. One Line Diagram 3. System Outline Drawings 4. Connection Details

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Signet Flow Transmitter

SOLUTIONS FOR AN EVOLVING WORLD RFL Programmable FSK Powerline carrier system

Rosemount 753R Remote Web Based Monitoring Indicator

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

Compact Model Fiber Deep Node 862 MHz with 42/54 MHz Split

Operation Manual February Opticom Infrared System

Power Supplies. Certifications and Compliances Recognized Component, ITE - UL Certified, ITE - CSA C22.2 CSA

AUM FAMILY Programmable DC Power Supplies

How to Choose Power Supplies

Electromechanical Power Products

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

NT240 TIMER. PROGRAMMABLE TIMER INSTRUCTIONS MANUAL V20x A INTRODUCTION TIMER OUTPUTS SPECIFICATIONS AUXILARY SUPPLY OUTPUT INSTALLATION TIMER INPUTS

Technical Data Sheet AMIK 300 / 301

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

Transcription:

CELLULAR POOL PUMP SWITCH WITH MEASUREMENT AND MODEL HAP00-S041911M2-1 Beyond AMI We Put You in Control When It Counts LED Indicators Mounting Bracket Meter Seal Mounting Brackets ½ seal tight or ¾ NPT Device Features Cost effective two-way remote controllable & programmable Over four million individual addresses with remote programmability Visual indicators Remote test functions All devices are pre-wired for installation Devices are pre-programmed per customer specifications Ability to record and transmit Host Voltage, Amperage and Line Frequency of a load at predetermined customizable intervals and report that data on request Remote auditing and load shed verification and reporting Distributed Intelligence Internal Diagnostics Cold Load Pick-up Receiver Visual Indicators Historical Event Counters Resume Local override and opt-out-secondary Option Power Provider Functionality Control strategies may be defined for each group, subgroup, or individual devices Devices may be assigned to multiple sets of groups and subgroups On-board intelligence for smooth ramp-in and ramp-out of control across the population of devices Events in progress may be interrupted with a smooth ramp-out across the population of devices Customizable control events from various shed/cycling strategies Control events may be targeted for each or all group, subgroup, or individual devices Non-volatile data storage has capacity for over 30 days data when recorded at 15 minute intervals

CELLULAR POOL PUMP SWITCH WITH MEASUREMENT AND MODEL HAP00-S041911M2-1 Circuitry: Non-Volatile Memory: COMMUNICATION Type: Regulatory Compliance: Microprocessor-controlled. 512K EEPROM DIRECT LOAD CONTROLLER MEASUREMENTS Cellular Dual-band CDMA 800 / 1900 MHz Built in UDP/TCP/IP stack Other Communication Paths available: FCC Cellular Operation Verizon Network Certified 2-Wire or 3-Wire Single-Phase Measurements RMS Voltage: Range: 192-288 VAC RMS Accuracy: ±1% RMS Current: Range: 0-60 A RMS Accuracy: ±1% Frequency: Range: 47-63 Hz Accuracy: ±0.5% Active Power: Range: 0 7.2kW Accuracy: ±2% ADDRESS CODES Individual Address: 4,194,304 (222) Possibilities. Common Individual Address: Common to all units. Extended Address: 16,384 (214) Possibilities. Upper Address: 128 (27) Possibilities. Lower Address: 128 (27) Possibilities. Address Assignment (Remote): From one up to 8 Upper and associated Lower Extended Addresses. Address Function: RELAY Relay Output: 2 Wires: Relay Rating: Wire Insulation: Time Out Duration: Time Out Tolerance: Test-on Duration Selection: TEST FUNCTIONS Receiver Operation Including Relay Coil Continuity: Propagation Test on LED: Controls load (Interrupts/Restores relay contact). 12 Gauge Via the Device s ½ flexible conduit fitting or ¾ MNPT, Length and fitting specified at time of order. One (1) Form B Contacts with a rating of 30 amps @ 240 VAC (Resistive Load) Other Relay Options Available 600V, 105 C (220 F). One of 16 preprogrammed intervals from 6 minutes to 120 minutes. ±10 Seconds, +20%/-0%, ±20%, User Selectable. Via Codes. LED indication in response to Test Command signal from a handheld transmitter or Load Management System Transmitter. LED indication in response to Propagation Test Signal or Load Management System Transmitter.

CELLULAR POOL PUMP SWITCH WITH MEASUREMENT AND MODEL HAP00-S041911M2-1 LED INDICATIONS Steady State: FUNCTIONS INDICATED Receiver Operation Check - Test Command Duration One of eight remotely programmable times from 2 (Test Commands Only): seconds to 1 hour. Specified at time of order Blink State: Whenever relay is interrupted. POWER REQUIREMENTS Power Input: 240VAC ±20% (192-288); 60 Hz. Input Power Connection: 18 Gauge Via the Device s fitting conduit. (2 Black) wires Wire Insulation: 600V, 105 C (220 F). Wire: 18 Gauge Standard UL 1015 Length specified at time of order Internal DC Power: +5VDC derived from 240 VAC/10 VAC step down transformer. Power Consumption: 7.5 Watts maximum at 240 VAC with full load. CONTROL DEVICE ENCLOSURE Type: High-impact Molded Lexan with neoprene enclosure gasket for raintight operation. Meets NEMA IV requirements with gasket and snap latch construction. Provision for utility meter seal. Dimensions: 6 3/8 X 8 3/8 X 2 7/8 1.2 lbs. Mounting: Mount in an upright position direct to air conditioner housing or to conduit box. Hangers are a part of the casing, required area is 8 X 8 3/8 X 8 1/2 ). Tinted Lid: For LED observation. OPERATING ENVIRONMENT Relative Humidity: Up to 95% (non-condensing). Operating Temperature: -30 C to 70 C Storage Temperature: -40 C to 85 C MISCELLANEOUS Surge Withstand Capability: Meets and exceeds ANSI C37.90a Automated Measurement and Verified Load Shed Spinning Reserve Verification Options: Remote Auditing Report Auditing Tamper Evident Reporting All devices are 100% Factory Tested and Inspected in accordance with Factory Acceptance Testing Procedures mutually determined with each utility. Specifications subject to change Lexan is a registered trademark of General Electric Company

CELLULAR POOL PUMP SWITCH WITH MEASUREMENT AND MODEL HAP00-S041911M2-1 INSTALLATION OPTIONS SECTION ¾ NPT Fitting 90 Elbow ½ Flexible Seal Tight Fitting Beyond AMI We Put You in Control When It Counts

CISCO POOL PUMP SWITCH WITH MEASUREMENT AND MODEL HAZ00-S041911M2-1 Beyond AMI We Put You in Control When It Counts LED Indicators Mounting Bracket Meter Seal Mounting Brackets ½ seal tight or ¾ NPT Device Features Cost effective two-way remote controllable & programmable Over four million individual addresses with remote programmability Visual indicators Remote test functions All devices are pre-wired for installation Devices are pre-programmed per customer specifications Ability to record and transmit Host Voltage, Amperage and Line Frequency of a load at predetermined customizable intervals and report that data on request Remote auditing and load shed verification and reporting Distributed Intelligence Internal Diagnostics Cold Load Pick-up Receiver Visual Indicators Historical Event Counters Resume Local override and opt-out-secondary Option Power Provider Functionality Control strategies may be defined for each group, subgroup, or individual devices Devices may be assigned to multiple sets of groups and subgroups On-board intelligence for smooth ramp-in and ramp-out of control across the population of devices Events in progress may be interrupted with a smooth ramp-out across the population of devices Customizable control events from various shed/cycling strategies Control events may be targeted for each or all group, subgroup, or individual devices Non-volatile data storage has capacity for over 30 days data when recorded at 15 minute intervals

CISCO POOL PUMP SWITCH WITH MEASUREMENT AND MODEL HAZ00-S041911M2-1 Circuitry: Microprocessor-controlled. Non-Volatile Memory: 512K EEPROM COMMUNICATION Type: Cisco Mesh Networks Other Communication Paths available: Regulatory Compliance: FCC DIRECT LOAD CONTROLLER MEASUREMENTS 2-Wire or 3-Wire Single-Phase Measurements RMS Voltage: Range: 192-288 VAC RMS Accuracy: ±1% RMS Current: Range: 0-60 A RMS Accuracy: ±1% Frequency: Range: 47-63 Hz Accuracy: ±0.5% Active Power: Range: 0 7.2kW Accuracy: ±2% ADDRESS CODES Individual Address: 4,194,304 (222) Possibilities. Common Individual Address: Common to all units. Extended Address: 16,384 (214) Possibilities. Upper Address: 128 (27) Possibilities. Lower Address: 128 (27) Possibilities. Address Assignment (Remote): From one up to 8 Upper and associated Lower Extended Addresses. Address Function: RELAY Relay Output: 2 Wires: Relay Rating: Wire Insulation: Time Out Duration: Time Out Tolerance: Test-on Duration Selection: TEST FUNCTIONS Receiver Operation Including Relay Coil Continuity: Propagation Test on LED: Controls load (Interrupts/Restores relay contact). 12 Gauge Via the Device s ½ flexible conduit fitting or ¾ MNPT, Length and fitting specified at time of order. One (1) Form B Contacts with a rating of 30 amps @ 240 VAC (Resistive Load) Other Relay Options Available 600V, 105 C (220 F). One of 16 preprogrammed intervals from 6 minutes to 120 minutes. ±10 Seconds, +20%/-0%, ±20%, User Selectable. Via Codes. LED indication in response to Test Command signal from a handheld transmitter or Load Management System Transmitter. LED indication in response to Propagation Test Signal or Load Management System Transmitter.

CISCO POOL PUMP SWITCH WITH MEASUREMENT AND MODEL HAZ00-S041911M2-1 LED INDICATIONS Steady State: FUNCTIONS INDICATED Receiver Operation Check - Test Command Duration One of eight remotely programmable times from 2 (Test Commands Only): seconds to 1 hour. Specified at time of order Blink State: Whenever relay is interrupted. POWER REQUIREMENTS Power Input: 240VAC ±20% (192-288); 60 Hz. Input Power Connection: 18 Gauge Via the Device s fitting conduit. (2 Black) wires Wire Insulation: 600V, 105 C (220 F). Wire: 18 Gauge Standard UL 1015 Length specified at time of order Internal DC Power: +5VDC derived from 240 VAC/10 VAC step down transformer. Power Consumption: 7.5 Watts maximum at 240 VAC with full load. CONTROL DEVICE ENCLOSURE Type: High-impact Molded Lexan with neoprene enclosure gasket for raintight operation. Meets NEMA IV requirements with gasket and snap latch construction. Provision for utility meter seal. Dimensions: 6 3/8 X 8 3/8 X 2 7/8 1.2 lbs. Mounting: Mount in an upright position direct to air conditioner housing or to conduit box. Hangers are a part of the casing, required area is 8 X 8 3/8 X 8 1/2 ). Tinted Lid: For LED observation. OPERATING ENVIRONMENT Relative Humidity: Up to 95% (non-condensing). Operating Temperature: -30 C to 70 C Storage Temperature: -40 C to 85 C MISCELLANEOUS Surge Withstand Capability: Meets and exceeds ANSI C37.90a Automated Measurement and Verified Load Shed Spinning Reserve Verification Options: Remote Auditing Report Auditing Tamper Evident Reporting All devices are 100% Factory Tested and Inspected in accordance with Factory Acceptance Testing Procedures mutually determined with each utility. Specifications subject to change Lexan is a registered trademark of General Electric Company

CISCO POOL PUMP SWITCH WITH MEASUREMENT AND MODEL HAZ00-S041911M2-1 INSTALLATION OPTIONS SECTION ¾ NPT Fitting 90 Elbow ½ Flexible Seal Tight Fitting Beyond AMI We Put You in Control When It Counts