TS16 - Pre-Instructional Survey

Similar documents
Modulating control valve

Field Devices and Wiring

Owner Operator Guide to Emerging Smart Technology

Fieldbus Foundation India Committee. Fieldbus Foundation Asset Management and Diagnosis Automation-2010, India

Technical Bulletin, Communicating with Honeywell TM ST3000/STT3000 Smart Transmitters

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610f

Digital Readout / Control Systems. > Features. Mechanical: u An overview of the dimensions can be found on the last page.

Chapter 7 Introduction to Instrumentation

Calibrating Fieldbus Transmitters??? - Yes, it is easy!

To Calibrate or Not to Calibrate a fieldbus transmitter? Dale Perry Pressure Marketing Manager Rosemount

Think About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental - Con't

Implementation Wireless Adapter Interface Module with Gateway Device for Connection to 4-20 ma Transmitters

TI25 - Pre-Instructional Survey

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

FOUNDATION Fieldbus: the Diagnostics Difference Fieldbus Foundation

SITRANS L Level instruments

Educational Courses 2016

Control in Field. 15 th December, NSE Complex, Goregaon /V42/Bgo Control in the Field 1

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

ROC800-Series HART Module

USING A INDUSTRIAL NETWORKED CONTROL SYSTEM FOR PRESSURE TANK SYSTEM

Analog Inputs and Outputs

The wireless alternative to expensive cabling...

HIM. Description The HIM HART Interface Module unlocks the full potential of new and in-place smart HART multivariable transmitters and valves.

Sturdy explosion proof housing and smart performance with innovative and ever-strong coil drive even under harsh working environments

Connecting DPI620G-IS to HART Devices

OFDM the 3 rd generation of narrowband Power Line Communications

PlantPAx Distributed Control System (DCS) Demonstrator - Pressure, Flow, Level, Temperature (3531-V0)

A New Generation of Pressure Transmitters

Fundamentals of Instrumentation & Process Control

KS 800 Multiple temperature controller

Rosemount 333 HART Tri-Loop

Application Note. Renu Electronics Private Limited. PID Instruction In IEC. Page 1

LOW POWER FLOW COMPUTERS Greg Phillips Bristol Babcock Inc Governors Circle West, Suite F, Houston, TX 77092

TAMIL NADU PUBLIC SERVICE COMMISSION. Post of Principal / Assistant Director (Training) Included in the Tamil Nadu Employment and Training Service

Think About Control Fundamentals Training. Terminology Control. Eko Harsono Control Fundamental

5 years! Modular Housings. IsoAmp PWR A Warranty

RS-232 to Current Loop Converters

CONTROLS CS-I. MFDC/AC Inverter Weld Control

EVK/EVM. Optical strip edge and centre guiding system. high-precision reliable easy to maintain

UNIVERSAL PNEUMATIC TRANSDUCER FEATURES

Foundation Fieldbus Control in the Field (CIF)

Transmitters BROCHURE

New Signal Conditioner VJ series

FTPM01 MEMS. Specifications Tire Pressure Monitoring System FTPM01 Rev 2.0, 5/2011

2012 Honeywell Users Group EMEA Tony Alexander Instrument Asset Management

measurement technology overview

A New Generation of Pressure Transmitters

Sustain.Ability. Kevin Boatright & John Yingst Field Device Manager: Instrument Nourishment through Smart Device Management

WirelessHART Applications ARASU THANIGAI PEPPERL+FUCHS ASIA PTE LTD

Accessories for EST4 Series

Wireless Reading of Sensirion Sensors By H. Moholdt

Catalog Hydraulics meets Electronics.

MODEL 970 HART PROTOCOL PRESSURE TRANSMITTER INSTALLATION MANUAL

GE Intelligent Platforms. PAC8000 Modular I/O

Automated E-Billing and Supply Control using Power Line Communication

SS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

ANALYSIS OF AN INTELLIGENT TEMPERATURE TRANSMITTER FOR PROCESS CONTROL

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Positioner with HART Communication Type 3780

RF4432 wireless transceiver module

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22.

AccuSolar SOLAR POWERED SYSTEM

The wireless alternative to expensive cabling...

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

The wireless alternative to expensive cabling...

IEEE Correction Engine Applications

A New Generation Of Pressure Transmitters -AII V5. ECNO : 610e

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Lecture 15: ISS Communications

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

Absolute Process Instruments

TRMC-19 GSM/GPRS DATALOGGER. Applications. Product description. Measure and remote monitoring

Power supply. Calibration. Surface finishing. Seal. Process connection

CALYS 150. Advanced documenting multifunction calibrator thermometer

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

NOVATO (MAXREFDES16#): 4-20MA LOOP-POWERED TEMPERATURE SENSOR WITH HART

PROCESS & TEMPERATURE CONTROLLERS

WaterLOG Product Guide

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

The wireless alternative to expensive cabling...

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.

CS601 Data Communication Solved Objective For Midterm Exam Preparation

Webinar Organizers. Ryan Shea. Don Miller. Joe Ryan. Support Specialist, Chat Moderator. Applications Specialist, Webinar Moderator

Technical Information Barrier RB223

BASIC ELECTRONICS FOR FIELD MEASUREMENT John Culp Emerson Process Management Remote Automation Solutions Houston, Texas

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

Process & Instrumentation Diagram * (P&ID) Tutorial

NC Joining Module NCFH

DeviceNet for Penning Gauges

Brooks Models SLAMf50, SLAMf51, SLAMf53 Mass Flow Controllers and Models SLAMf60, SLAMf61, SLAMf63 Mass Flow Meters

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

DUCATI INSTRUMENTS COMPARISON TABLE

AC and DC solutions- Multiple AC and DC solutions available, please contact factory for your application.

NC Joining Module NCFH

A Wireless Mesh IoT sensor system FEATURES DESCRIPTION. Vicotee Njord series Nodes

TROUBLESHOOTING A TECHNICIAN S GUIDE 2ND EDITION. William L. Mostia, Jr., P. E. ISA TECHNICIAN SERIES

PROPRIETARY CAN COMMUNICATION DOCUMENT. Proprietary CAN Communication for the PCS Automatic Transmission Controller

MI June Instruction. I/A Series Intelligent Pressure Transmitters. Operation, Configuration, and Calibration Using a HART Communicator

Transcription:

TS16 - Pre-Instructional Survey Name: Date 1. What do you understand by the term Digital Transmitter? a. A transmitter that auto-configures and auto-calibrates itself. b. A transmitter that can be configured and re-ranged using a communicator. c. A transmitter that can change the type of variable it is measuring in the process. d. A transmitter that auto detects the system it is connected to. 2. What is the difference between a digital transmitter and an analog transmitter? a. A digital transmitter is a microprocessor digital device that can communicate. b. Digital transmitters are an enhanced version of an analog transmitter. c. Analog transmitters measure more accurately than a digital transmitter. d. There is no difference. 3. A digital transmitter samples the process variable, what does this mean? a. A carrier gas is used to measure the process variable. b. The transmitter measures the process once a second. c. The transmitter measures the process variable at a regular interval defined by the vendor. d. The transmitter measures the process variable on a random basis. 4. What is the HART protocol? a. A communication protocol to configure intelligent alarm panels. b. A communication protocol to configure operator stations. c. A communication protocol for configuring and ranging instrument field devices. d. A communication protocol for configuring calibration equipment. 1

5. What is a Multivariable transmitter? a. A transmitter that can do advanced regulatory control. b. A transmitter that can measure and transmit more than one process variable. c. A transmitter that has the capability of self-calibration. d. A smart transmitter that can be connected to another smart transmitter. 6. Which of the following is not a bus system? a. SP50 Foundation Fieldbus H1 and H2 b. Ethernet c. Profibus d. 4-20mA 7. What is a digital valve controller? a. It is a loop controller added to a control valve. b. It is a software feature in a DCS or PLC system. c. It is a digital valve positioner system. d. It is a fully electrical control valve. 8. What is a Modem?: a. A device that turns computer based signals into FSK tones and FSK tones back into computer signals. b. A device that set s up network configuration. c. A device that is used for instrument configuration. d. A device that turns computer serial signals into parallel signals. 9. What do you understand by the term Fieldbus? a. Fieldbus is a bi-directional communication protocol used to connect DCS I/O and control systems. b. Fieldbus is a bi-directional communication protocol used to connect digital field-level devices to each other and to control systems. c. Fieldbus is a bi-directional communication protocol used to connect DCS/PLC systems to office based systems. d. All of the above. 2

10. What is a function block? a. Something you use to program control systems in C language. b. A function block is used in control systems to do calculations only. c. A function block is used to do square root extraction in DP flow meters. d. A function block is a software tool to easily configure measurement and control systems. 11. Which of the following can be a HART master? a. DCS, PC or field device. b. Field device and/or HART communicator. c. DCS, PC or HART communicator. d. Only a field device can be a HART master. 12. What is the function of an analog to digital converter in a smart transmitter? a. Allows the milliamp output signal to be read by the HART communicator. b. Digitizes the analog signal from the analog process sensor. c. Allows for an external reference signal to be connected to the HART communicator. d. There is no such device in a smart transmitter. 13. What does HART polling mean? a. When a HART master requests information from a HART slave device. b. When a HART slave device requests information from a HART master. c. This is the configuration that has to be done to connect two HART masters. d. This is the configuration that has to be done to connect two HART slave devices. 14. When calibrating a field device the accuracy of the test equipment must be? a. The same accuracy as the field device. b. More accurate then the accuracy of the field device. c. Less accurate then the accuracy of the field device. d. Accuracy is unimportant for a calibration of a field device. 15. What powers a loop powered field device? a. Field devices cannot be loop powered as they need more than 20mA s to operate. b. A separate second ma signal is required to power up the transmitter. c. All field devices need external power. d. It is powered by part of the 4mA offset current signal. 3

16. The main purpose of a digital valve controller is to control: a. The process b. The position of the valve c. The amount of air pressure on the actuator d. The pressure drop across the valve 17. A dynamic signature test is used to determine: a. The tech that tested the valve b. The bench set of the valve c. The valve position d. The dynamic error band 18. A step response test will determine: a. The amount of valve movement b. The amount of deadband c. The time for T63, T86, etc. d. The time for full valve stroke 19. Variable mapping is a term associated with which transmitter? a. Single variable pressure transmitter b. Single element temperature transmitter c. Absolute pressure transmitter d. Multivariable flow transmitter 20. The tri-loop transmitter is used to: a. Convert 4-20 ma to 3-15 psi b. Convert the HART protocol to fieldbus c. Convert digital signals to analog current signals d. All of the above 4

TS16 - Pre-Instructional Survey Answers Name: Date 1. What do you understand by the term Digital Transmitter? a. A transmitter that auto-configures and auto-calibrates itself. b. A transmitter that can be configured and re-ranged using a communicator. c. A transmitter that can change the type of variable it is measuring in the process. d. A transmitter that auto detects the system it is connected to. 2. What is the difference between a digital transmitter and an analog transmitter? a. A digital transmitter is a microprocessor digital device that can communicate. b. Digital transmitters are an enhanced version of an analog transmitter. c. Analog transmitters measure more accurately than a digital transmitter. d. There is no difference. 3. A digital transmitter samples the process variable, what does this mean? a. A carrier gas is used to measure the process variable. b. The transmitter measures the process once a second. c. The transmitter measures the process variable at a regular interval defined by the vendor. d. The transmitter measures the process variable on a random basis. 4. What is the HART protocol? a. A communication protocol to configure intelligent alarm panels. b. A communication protocol to configure operator stations. c. A communication protocol for configuring and ranging instrument field devices. d. A communication protocol for configuring calibration equipment. 1

5. What is a Multivariable transmitter? a. A transmitter that can do advanced regulatory control. b. A transmitter that can measure and transmit more than one process variable. c. A transmitter that has the capability of self-calibration. d. A smart transmitter that can be connected to another smart transmitter. 6. Which of the following is not a bus system? a. SP50 Foundation Fieldbus H1 and H2 b. Ethernet c. Profibus d. 4-20mA 7. What is a digital valve controller? a. It is a loop controller added to a control valve. b. It is a software feature in a DCS or PLC system. c. It is a digital valve positioner system. d. It is a fully electrical control valve. 8. What is a Modem?: a. A device that turns computer based signals into FSK tones and FSK tones back into computer signals. b. A device that set s up network configuration. c. A device that is used for instrument configuration. d. A device that turns computer serial signals into parallel signals. 9. What do you understand by the term Fieldbus? a. Fieldbus is a bi-directional communication protocol used to connect DCS I/O and control systems. b. Fieldbus is a bi-directional communication protocol used to connect digital field-level devices to each other and to control systems. c. Fieldbus is a bi-directional communication protocol used to connect DCS/PLC systems to office based systems. d. All of the above. 2

10. What is a function block? a. Something you use to program control systems in C language. b. A function block is used in control systems to do calculations only. c. A function block is used to do square root extraction in DP flow meters. d. A function block is a software tool to easily configure measurement and control systems. 11. Which of the following can be a HART master? a. DCS, PC or field device. b. Field device and/or HART communicator. c. DCS, PC or HART communicator. d. Only a field device can be a HART master. 12. What is the function of an analog to digital converter in a digital transmitter? a. Allows the milliamp output signal to be read by the HART communicator. b. Digitizes the analog signal from the analog process sensor. c. Allows for an external reference signal to be connected to the HART communicator. d. There is no such device in a smart transmitter. 13. What does HART polling mean? a. When a HART master requests information from a HART slave device. b. When a HART slave device requests information from a HART master. c. This is the configuration that has to be done to connect two HART masters. d. This is the configuration that connects two HART slave devices. 14. When calibrating a field device the accuracy of the test equipment must be? a. The same accuracy as the field device. b. More accurate then the accuracy of the field device. c. Less accurate then the accuracy of the field device. d. Accuracy is unimportant for a calibration of a field device. 15. What powers a loop powered field device? a. Field devices cannot be loop powered as they need more than 20mA s to operate. b. A separate second ma signal is required to power up the transmitter. c. All field devices need external power. d. It is powered by part of the 4mA offset current signal. 3

16. The main purpose of a digital valve controller is to control: a. The process b. The position of the valve c. The amount of air pressure on the actuator d. The pressure drop across the valve 17. A dynamic signature test is used to determine: a. The tech that tested the valve b. The bench set of the valve c. The valve position d. The dynamic error band 18. A step response test will determine: a. The amount of valve movement b. The amount of deadband c. The time for T63, T86, etc. d. The time for full valve stroke 19. Variable mapping is a term associated with which transmitter? a. Single variable pressure transmitter b. Single element temperature transmitter c. Absolute pressure transmitter d. Multivariable transmitter 20. The tri-loop transmitter is used to: a. Convert 4-20 ma to 3-15 psi b. Convert the HART protocol to fieldbus c. Convert digital signals to analog current signals d. All of the above 4