OPCOM100-DAD4D 4-Channel Bidirectional DWDM ADM. Typical Application. Figure.1 Chain Topology. Datasheet. Raisecom Technology Co., Ltd.

Similar documents
OPCOM100-DMU40 40-Channel DWDM. Mux/Demux. Typical Application. Figure.1 Point to Point Topology. Datasheet. Raisecom Technology Co., Ltd.

DATASHEET FMU-MD08E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

OPC1600 MUX WDM OADM SPLITTER

Data Center & Cloud Computing DATASHEET. 100 GHz DWDM Passive Optical Add/Drop Multiplexers Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 16 Channels C27-C42 Dual Fiber DWDM Mux Demux 1U Rack Mount, LC/UPC

FMU-MC09-A/B, Pair Packaged DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Overview. Highlights. General Specification. Datasheet

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 8 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 4 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

DATASHEET FMU-MC04E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

Optical Passives (ISP)

DATASHEET FMU-MC04E-A/B, Pair Packaged, w/expansion Port

16 Channels C21-C36 Dual Fiber DWDM Mux Demux, w/expansion Port 1U Rack Mount, LC/UPC

WaveSmart Wave Division Multiplexing (WDM)

CWDM Cisco CWDM wavelengths (nm)

CISCO DWDM GBICS. Figure 1. Cisco DWDM GBICs. Main features of the Cisco DWDM GBICs:

Wave Division Multiplexing. Passive Mux/Demux Modules & Cables. Datasheet. Features. Overview. Typical 2-Channel Passive Mux/Demux Application

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

WDM -Transmission V-1.

WaveReady 8-Channel DWDM OSP Optical Add/Drop Multiplexer for Splice Enclosures. MDF-08MD1N0xB and MDF-08MD1Z0xB

WaveReady Single-Channel DWDM Add/Drop for OSP Splice Enclosure. MDF-01AD10xx0

50/100 GHz, 100/200 GHz Passive Interleavers. IBC Series

XM40-QD20LD-J 40-ch Multiplexer/Demultiplexer

WDM. Coarse WDM. Nortel's WDM System

Datasheet. 40ch DWDM Mux Demux + Monitor Port 1U Rack Mount, LC/UPC. Overview. Highlights

On the subsequent pages, you will find the full, parameter-for-parameter comparison. If you have any questions, please contact Fiberdyne Labs.

Dense Wavelength Division Multiplexer (DWDM) 200 GHz Spacing, Multi-Channel, 2ch, 4ch, 8ch, 16ch, 20ch in PEACOC Flexible Tray

Datasheet. FMU-MC04-A/B, Pair Packaged 4 Channels Single Fiber CWDM Mux Demux, Plug-in Module, LC/UPC. Overview. Highlights

WaveReady 40- and 44-Channel Multiplexer/ Demultiplexer with Test Channel. MDX-40MD101CB and MDX-44MD101CB

LEAD Fiber Optics PRODUCT CATALOGUE

XSD Single Fiber series DWDM passive optical components

Further more all functions as well available in splice trays or splice enclosures (-40 to 85 C)

Headend Optics Platform (CH3000)

DWDM Dual Fiber series

Module 19 : WDM Components

Cisco Prisma Optical Passive Components

Class 1 LED of 850 nm for (short-range) applications. Class 1 laser of 1300 nm for (medium-range) applications.

CWDM Single Fiber series

Wavelength Converter Specification: WX-1000

Cisco ONS Metropolitan Dense Wavelength Division Multiplexing 100-GHz FlexLayer Filter Solution

GS7000 & GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

WaveReady Multi-Degree Reconfigurable Optical Add/Drop Multiplexer WRS-05AD1C00B

10Gbps XFP Optical Transceiver RTXM226-6XX

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

Digital Return System

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform

Testing of DWDM + CWDM high speed systems. Christian Till Technical Sales Engineer, EXFO

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

Cisco s CLEC Networkers Power Session

81.71T-XDWDM-R6-TP 10Gb/s Tunable DWDM XFP 80km Transceiver

Digital Return System

Prisma DWDM Passives. Features. Optical Passive Components

WaveReady CWDM Add/Drop for OSP Splice Enclosure

Thursday, April 17, 2008, 6:28:40

/ On the web: / Telephone: IS-FIBER (800)

DWDM SFP 4.25Gb/s Transceiver 30Km Hot Pluggable, Duplex LC, 3.3v C Band 100-GHz DWDM DFB-LD PDSFP-96-1XX12-22F

Pass Cisco Exam

Technical Specifications

Multi-Wavelength Meter AQ6141. Perfect for Wavelength Analysis in DWDM Systems

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

Cisco Enhanced Digital Return (EDR) 85 System Compact Segmentable Nodes

Optical Passives and Accessories

OMxxDyy-100zz-ab:cd-(M5)-XXYY

1.25Gb/s 160km DWDM SFP Transceiver (OP340GD-D ) Hot Pluggable, Duplex LC, 100GHz, DWDM DFB & APD, Single-mode, DDM

Dual & Single Fiber Compact CWDM Mux Demux

DWDM-40C. User manual. 40-ch 100GHz Dense Wavelength Division Multiplexing System. Rev. A

LEAD Fiber Optics PRODUCT CATALOGUE

Xeston Technologies. XESTON 1550nm DWDM CW DFB Laser With PM Fiber. XQF935 Series Specification Datasheet (Preliminary)

10Gb/s Tunable DWDM XFP 80km Transceiver

XFP DWDM 10G 80Km ZR SLXFD-10XX-ZR

DWDM Mux/Demux product range

Transceiver, Chassis Connectors, and Cable and Adapter Specifications

GYM Bilgi Teknolojileri

Why Using Fiber for transmission

Chapter 10 WDM concepts and components

Cisco EDR 85 System: Modules for Cisco GainMaker and GS7000

CATALOG. Network Access & Connectivity

80KM DWDM SFP+ Optical Transceiver

DWDM XFP Series XFPD-ER. XFP Single-Mode Dual Fiber DWDM Transceiver for 10GbE/10GFC/SDH/SONET. Features. Applications. Product Description

GPD-XX24-08CD GIGALIGHT DWDM SFP Optical Transceiver

XFP DWDM 10G 40Km ER SLXFD-10XX-ER

Prisma and Laser Link DWDM Passives for LGX-Compatible Systems

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

Optiva Un-Amplified MW Transport 40 GHz System

Cisco Prisma II Quad Optical Input Enhanced Digital Return (EDR) Receiver for Compact Segmentable Nodes

Passive WDM Networking

Model 600 Switching Matrix Series Transparent Switching Matrix Modules for High-Bandwidth DSL Test Automation

OptiSheath Advantage Sealed Terminal Solution for WDM Applications, UCA4-XX An Evolant Solutions Product

Features: Applications: Description:

DS10-F007. Datasheet. Initial Date R&D Dept. GH Zheng. OE OFD6xx418 Written Team. PN OFD6xx418 Description XFP, DWDM 80KM

A3422 XMTDR. Digital Return Optical Transmitter Module. Features

Odd. Even. Insertion Loss (db)

Optiva RF-Over-Fiber Design Tool User s Guide. Revision 1.0 March 27, 2015

Optiva OTS-2 18 GHz Amplified Microwave Band Fiber Optic Links

Transcription:

Datasheet OPCOM100-DAD4D 4-Channel Bidirectional DWDM ADM OPCOM100-DAD4D is a 4-channel DWDM (Dense Wavelength Division Multiplexing) bidirectional add-and-drop device which transmits services on a dual-strand fiber. It performs de-multiplexing and multiplexing of four specific color wavelengths usually at an intermediate station to drop eight services from both west and east directions. The 'X' suffix stands for four specific DWDM color wavelength among C21C22C23C24, C25C26C27C28,C29C30C31C32 C33C34C35C36,C37C38C39C40,C41C42C43C44,C45C46C47C48 C49C50C51C52,C53C54C55C56,C57C58C59C60 (Cxy means C-band optical channel number).the wavelength channel spacing is 100GHz. The device has the advantages of high integration and Low failure rate which can not only improve the integration of the system and reduce system failure points, but also enhance the system channel equalization. OPCOM100-DAD4D is appropriate for the 40 DWDM wavelengths transmission system which can provide a flexible Pay-As-You-Grow solution for a cost-effective and complete range of services transmission by directly deploying Fast Ethernet, Gigabit Ethernet, fiber channel and SDH services utilizing DWDM technologies, increasing the flexibility and capability of existing fiber lines cost-effectively. OPCOM100-DAD4D-X Typical Application Figure.1 Chain Topology

Figure.2 Point to multi Points Topology Figure.3 DWDM Ring Topology

Key Features Features Construction Operating wavelength Wavelength spacing Service channel Channel uniformity Insertion loss Adjacent channel isolation Non-adjacent channel isolation Wavelength thermal stability Insertion loss thermal stability PDL(polarization dependence loss) Return loss Directivity Transmission media Provides 4-channel DWDM bidirectional add and drop wavelengths Transparent to services, working at any signal speed ADM works without power supply highly integrated system, less fault points modular plug-in design; installed in DAD4D 2-slot chassis; C21-C60 100 GHz DWDM:4 0.5 db 2.5 db(add and drop wavelength) 3.4 db(straight in wavelength) 28 db 0.001 nm/ 0.008 db/ 0.3 db 9/125um single mode fiber Specifications User Side Port Line Side Port Demensions Working Ambience LC/UPC optical port LC/UPC optical port Modular: 1U high 19 inches width Temp: -5~65 centigrade

Storage Ambience RH: 20~90% non-condensing Temp: -40~85 centigrade RH: 5~90% non-condensing Ordering Information OPCOM100-DAD4D-2124 OPCOM100-DAD4D-2528 OPCOM100-DAD4D-2932 OPCOM100-DAD4D-3336 OPCOM100-DAD4D-3740 OPCOM100-DAD4D-4144 OPCOM100-DAD4D-4548 OPCOM100-DAD4D-4952 OPCOM100-DAD4D-5356 OPCOM100-DAD4D-5760 C21,C22,C23,C24 passive add and drop card, Optical interface: LC/UPC; C25,C26,C27,C28 passive add and drop card, Optical interface: LC/UPC; C29,C30,C31,C32 passive add and drop card, Optical interface: LC/UPC; C33,C34,C35,C36 passive add and drop card, Optical interface: LC/UPC; C37,C38,C39,C40 passive add and drop card, Optical interface: LC/UPC; C41,C42,C43,C44 passive add and drop card, Optical interface: LC/UPC; C45,C46,C47,C48 passive add and drop card, Optical interface: LC/UPC; C49,C50,C51,C52 passive add and drop card, Optical interface: LC/UPC; C53,C54,C55,C56 passive add and drop card, Optical interface: LC/UPC; C57,C58,C59,C60 passive add and drop card, Optical interface: LC/UPC; ITU-T Channel Number Centre Frequency(THz) Centre Wavelength(nm) ITU-T Channel Number Centre Frequency(THz) Centre Wavelength(nm) C21 192.1 1560.61 C22 192.2 1559.79 C23 192.3 1558.98 C24 192.4 1558.17 C25 192.5 1557.36 C26 192.6 1556.55 C27 192.7 1555.75 C28 192.8 1554.94 C29 192.9 1554.13 C30 193.0 1553.33 C31 193.1 1552.52 C32 193.2 1551.72 C33 193.3 1550.92 C34 193.4 1550.12 C35 193.5 1549.32 C36 193.6 1548.51 C37 193.7 1547.72 C38 193.8 1546.92 C39 193.9 1546.12 C40 194.0 1545.32 C41 194.1 1544.53 C42 194.2 1543.73

Datasheet C43 194.3 1542.94 C44 194.4 1542.14 C45 194.5 1541.35 C46 194.6 1540.56 C47 194.7 1539.77 C48 194.8 1538.98 C49 194.9 1538.19 C50 195.0 1537.40 C51 195.1 1536.61 C52 195.2 1535.82 C53 195.3 1535.04 C54 195.4 1534.25 C55 195.5 1533.47 C56 195.6 1532.68 C57 195.7 1531.90 C58 195.8 1531.12 C59 195.9 1530.33 C60 196.0 1529.55