PI-10 Broadband Power Indicator

Similar documents
PI-150 Broadband Power Indicator

2100L Broadband Power Amplifier

3100LA Broadband Power Amplifier

A 500 Broadband Power Amplifier

1140LA Broadband Power Amplifier

Broadband Power Amplifier

A 075 Broadband Power Amplifier

2200L Broadband and Power Amplifier

1040L Broadband Power Amplifier

411LA Broadband Power Amplifier

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

Model 7000 Low Noise Differential Preamplifier

COM-POWER OPERATION MANUAL ACS W

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Current Probe Fixture Instruction Manual

R-Series R235LS 2-Channel Power Amplifier with Local Source Switching

Bulk Current Injection Probe Test Procedure

Advanced Test Equipment Rentals ATEC (2832)

QNP Accessory. For BLAXH300/ MHz Operating & Service Manual. Version

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

Model 1791 VHF Radio User's Manual

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

TECHNICAL SPECIFICATIONS OF STORES AND DRAWINGS.

CBA 400M MHZ to 400 MHZ

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

CMP-300 Composite Mixer/ Distribution Amplifier

BLAX2500. RF Power Amplifier MHz Operating & Service Manual BRUKER. Version

INSTRUMENTS, INC. Models 2960AR and 2965AR Disciplined Rubidium Frequency Standards. Section Page Contents

Model 4007DDS. 7 MHz Sweep Function Generator

Broadband Current Probe Series Operation Manual

Opus 21 s80 Integrated Amplifier Owner's Manual

SAS-562B Active Loop Antenna Operation Manual

SAS-563B Active Loop Antenna Operation Manual

Broadband Current Probe Series Operation Manual

Important Safety Information

INSTRUCTION MANUAL LKG

Instruction Manual Model M Switch, DPDT, Manual Select

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

DAA AES/EBU Digital Audio Distribution Amplifier. User Manual. I.R.T. Communications Pty Ltd

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D Herxheim Tel. (07276) FAX 6978

Installation & Service Manual

LPF-100 Composite Low Pass Filter

Introduction. Specifications. Features. Controls. Model 103

Model Hz to 10MHz Precision Phasemeter. Operating Manual

PDB4. Four Channel Passive Direct Box USER'S GUIDE

EO Modulator Driver and Source Models 3363-A, 3363-B, and 3363-C

SX204. Headphone Amplifier. Symetrix. Owner s Manual

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

léìë=on ëpm=fåíéöê~íéç=^ãéäáñáéê lïåéêdë=j~åì~ä êéëçäìíáçå

SPM-50 RF Spectrum Power Meter PC Software User Manual

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Model 34A. 3Hz to 2MHz 2-Channel Butterworth/Bessel HP, LP, BP, BR Plug-In Filter Card for Model 3905/3916 Chassis.

INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL Copyright 2008 by Bird Electronic Corporation Instruction Book P/N Rev.

Log Periodic Antenna

About JFW Industries, Inc.

1 FUNCTIONAL DESCRIPTION WAY SPLITTER/INPUT BOARD FET RF AMPLIFIERS WAY POWER COMBINER VSWR CONTROL BOARD...

DANFYSIK A/S - DK-4040 JYLLINGE - DENMARK

INSTRUCTIONS AVX-FILT SERIES OF RISE TIME FILTERS FOR USE WITH AVR-EBF6-B TFR TEST SYSTEMS SERIAL NUMBER:

DSTS-5A/2C User's Manual

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

MICRO SERIES MONITORS

Model MV106J/MV116J. ±10nVdc to ±11Vdc Precision DC Voltage Standard Source. Operating Manual

Advanced Test Equipment Rentals ATEC (2832)

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

EA3012 TRANSCONDUCTANCE AMPLIFIER OPERATION MANUAL

CHALLENGER II HF LINEAR AMPLIFIER

MODEL FS-4 INSTRUCTION MANUAL R.L. DRAKE COMPANY, MIAMISBURG, OHIO, U.S.A.

MZ2 HEADPHONE AMPLIFIER, PREAMP, & STEREO AMPLIFIER USER GUIDE

CLEANING CALIBRATION INTERVAL

Technical Description and User Manual E-band CW power meter DPM-12 s/n N-1204/21-T

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

PCX-7401 Pulsed Current Source Operation Manual

USER'S MANUAL. Model : K

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

SAS-551 Passive Monopole Antenna Operation Manual

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

ERSA MINOR Line array Datasheet

HTA125A/250A. Power Amplifiers. Installation & Use Manual

SDI SPECTRADYNAMICS, INC GHZ RUBIDIUM FREQUENCY SYNTHESIZER OPERATING MANUAL

TIA-952 Optical/Electrical Converter. Operating Instructions

Model 3210C. 100 Ampere AC Current Standard. Operating Manual

AAA Balanced / Unbalanced Line Audio Interface Amplifiers. User Manual. I.R.T. Communications Pty Ltd

A Channel Amplifier

MODEL 3 MONO AMPLIFIER OWNER S MANUAL

TECHNICAL DESCRIPTION

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Instruction Manual MTX-8485C MRX-8485C Four Channel Video Multiplexer with Bi-directional Data

High Performance Microphone Splitter. Artcessories. User's Manual

User Manual. ilive 2 Wireless microphone system

MICROTUBE 100. OWNER S MANUAL (version 1)

Random & Sinusoidal Jitter Injector. Main Unit Operation Manual

DPA-1.2. Instruction Manual. 2 Channel Amplifier with Auto A/B Selector DPA-1.2 DPA-1.2 POWER SERIAL # LINE INPUT SENSING SPEAKER B OUT

PA WATT PORTABLE PA SYSTEM PRODUCT MANUAL

Professional UHF Rechargeable Wireless Microphone System POWER ON/OFF BATTERY CHARGE. Green Light (Full) Better Music Builder DOWN VOLUME

DA208 & DA416 DISTRIBUTION AMPLIFIERS OPERATING AND MAINTENANCE MANUAL

Transcription:

PI-10 Broadband Power Indicator HIGH RF VOLTAGES MAY BE PRESENT AT THE PORTS OF THIS UNIT. All operating personnel should use extreme caution in handling these voltages and be thoroughly familiar with this manual. Do not attempt to operate this unit prior to reading this manual. subject to change without notice. August 2008 1 Revision A

Warranty Electronics & Innovation Ltd., (hereafter E&I) warrants for the period of one year from the date of original delivery, each unit to be free of defects in materials and workmanship. For the period of 12 months E&I will, at its option, repair or replace defective parts so as to render the unit fully operational such that it performs according to the original specifications; free of charge to the original purchaser. Should warranty service be required, the unit must be returned to E&I, freight cost to be borne by the owner. If, in our opinion, the unit has been damaged by use outside the limits prescribed in this manual or by accident, then the warranty shall not be honored. In such a case E&I will provide an estimate for repair, assuming repair is possible and provide a quote at standard service rates. Contents Chapter 1 General Information 3 Chapter 2 Operation..4 Chapter 3 Technical Information.7 Chapter 4 Maintenance 8 Chapter 5 Safety 12 subject to change without notice. August 2008 2 Revision A

Chapter 1 Introduction The PI-10 is a broadband solid state power indicator covering the frequency spectrum from 100 KHz to 10 MHz. It measures forward and reflected power of the system that it is inserted into. This information is displayed via an integral liquid crystal display and additionally the information can be downloaded to a pc via the RS232 connector at the rear of the unit. It is rated for a maximum input of 200 watts of RF power. An integral power supply permits operation from 100/240 single phase AC power. 1.2 INSTRUMENTATION IDENTIFICATION Each instrument is identified by a serial number tag on the back panel of the unit. Both the model number and the serial number should be quoted to identify specific unit. 1.3 SPECIFICATIONS Physical and electrical specifications are listed in Table 1-1 below subject to change without notice. August 2008 3 Revision A

Table 1-1. SPECIFICATIONS FREQUENCY COVERAGE: INSERTION LOSS: FORWARD PORT ACCURACY: REVERSE PORT ACCURACY: INPUT IMPEDANCE OUTPUT IMPEDANCE: POWER REQUIREMENTS: SIZE: WEIGHT: CONNECTORS: OPERATING TEMPERATURE: 100 khz to 10 MHz. 0.1 db max +/- 5% FSD +/- 5% FSD 50 ohms, VSWR, 1.5:1 Maximum. 50 ohms, VSWR, 1.5:1 Maximum 100 240 VAC 47-63 Hz. 5 1/4 X 16.5 X 18.1inches 13.4 X 41.9 x 46.0 cm. 5 pounds 2.3 kg BNC 0 40 C Chapter 2 Operation 2.1 INTRODUCTION The PI-10 RF power indicator is used to measure the RF level of signal sources in the 100 KHz to 10 MHz range. No tuning or any other form of adjustment is required. The PI-10 displays forward and reflected power of the system that it is inserted into. The characteristic impedance of the instrument is 50 Ω. 2.2 MAINS VOLTAGE The unit accommodates AC line voltages from 100 TO 240 VAC 47 63 Hz 2.3 OPERATION A line cord is supplied to form a connection between the mains supply and the rear of the unit. Plug this into the AC input at the rear of the unit and the AC mains outlet. August 2008 4 Revision A

2.3.1 Proceed as follows: (i) (ii) (iii) (iv) Ensure that there is at least 3 or 7.5 cm clearance at the rear of the unit for air flow. Ensure RF input voltage is not excessive a. Max input is 200 Watts Connect the output via a 50 ohm coaxial lead and BNC plug to the load. Connect the input signal via a 50 ohm coaxial lead and BNC plug to the input connector. 2.3.2 Front Panel Display The PI-10 front panel has a passive LCD display designed for simplicity and ease of use. During initialization, the LCD shows the software revision. After the meter is initialized, the LCD indicates Forward Power, Reflected Power, and insturment status (see figure 2.1). Figure 2.1 : Front Panel Display Pf: W Pr: W Status: Where Pf refers to forward power, Pr refers to reverse power, and Status indicates OK. 2.3.3 RS 232 Interface The PI-10 features a standard RS-232 serial interface suitable for connection to a PC or host system. The communication protocol is extremely simple to facilitate readback and control with readily available terminal programs such as Hyperterm. The RS-232 link has the following parameters: Baud rate: 19200 Data bits: 8 Parity: Stop bits: 1 none Flow control: none August 2008 5 Revision A

An example configuration using HyperTerminal on a PC is shown in figure 2.2. Figure 2.2: Example RS-232 setup using Hyper Terminal In the default state, the RS-232 port will echo the same information sent to the front panel LCD display, allowing a running datalog to be stored to disk using the capture feature of the terminal program. Single character commands can be sent to the amplifier to achieve the following: "1" key enables telemetry (readback similar to LCD display) - this is the default mode at power up 0 key disables telemetry (Complement to 1 key) Chapter 3 Technical Description 3.1 GENERAL DESCRIPTION The PI-10 is designed to measure signals in the frequency band of 100 KHz to 10 MHz. The signal from the front panel BNC connector is fed via a length of 50 ohm coaxial cable into the RF bi-directional coupler. The output of the coupler is then fed directly to the BNC connector on the front panel, this is the unit output. August 2008 6 Revision A

The forward and reverse coupled ports of the bi-directional coupler are fed to the RF detector which is situated on the control board. The RF detector feeds a voltage, which is representative of the true RMS power to the control board proper. The control board in turn drives the front panel display. The switch mode power supply unit provides a 5 VDC output which feeds the control board. Chapter 4 Maintenance 4.1 INTRODUCTION The E&I PI-10 RF Power Indicator requires no periodic maintenance. The instrument is unconditionally stable and is fail-safe under all load conditions. Damage can only be externally caused by the incorrect selection of the AC August 2008 7 Revision A

supply voltage or by an input signal in excess of the specified 200W equivalent to a power level of 53dBm. This chapter therefore, deals only with certain fundamental procedures for fault location. Performance limits quoted are for guidance only and should not be taken for guaranteed performance specifications unless they are also quoted in the Specification Section 1.2. 4.2 PERFORMANCE CHECKS To determine the amplifier s performance carry out the following procedure. 4.2.1 Initial Check 4.5 PACKAGING FOR RESHIPMENT In the event of the equipment being returned for servicing it should be packed in the original shipping carton and packing material. If this is not available, wrap the instrument in heavy paper or plastic and place in a rigid outer box of wood, fiberboard or very strong corrugated cardboard. Use ample soft packing to prevent movement. Provide additional support for projecting parts to relieve these of unnecessary shock. Close the carton securely and seal with durable tape. Mark the shipping container FRAGILE to ensure careful handling. Chapter 5 Safety: Do not attempt to operate this unit with the cover removed. High AC and DC voltages are present. The cover protects against electrical shock due to AC line voltages, high DC and RF fields. Further the cover provides part of the cooling system design. Components, specifically on the RF driver board are prone to over-heat and eventual failure if the unit is operated without the cover in place. Ensure that the load is connected to the output prior to connecting the RF input to the unit. This will prevent high voltages being present and exposed at the output connector. Only use the AC cord provided or equivalent. Ensure that the mains outlet is properly grounded. August 2008 8 Revision A