Comparative Analysis of Leakage Power Reduction in Low Power Bio Instrumentation Amplifier Using 130nm MOSFET

Similar documents
Pankaj Naik Electronic and Instrumentation Deptt. SGSITS, Indore, India. Priyanka Sharma Electronic and. SGSITS, Indore, India

ANALYSIS AND DESIGN OF HIGH CMRR INSTRUMENTATION AMPLIFIER FOR ECG SIGNAL ACQUISITION SYSTEM USING 180nm CMOS TECHNOLOGY

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 03, 2016 ISSN (online):

CHAPTER 3. Instrumentation Amplifier (IA) Background. 3.1 Introduction. 3.2 Instrumentation Amplifier Architecture and Configurations

A PSEUDO-CLASS-AB TELESCOPIC-CASCODE OPERATIONAL AMPLIFIER

LOW POWER FOLDED CASCODE OTA

Research Article Design a Bioamplifier with High CMRR

DESIGN OF A NOVEL CURRENT MIRROR BASED DIFFERENTIAL AMPLIFIER DESIGN WITH LATCH NETWORK. Thota Keerthi* 1, Ch. Anil Kumar 2

A Novel Design of Low Voltage,Wilson Current Mirror based Wideband Operational Transconductance Amplifier

International Journal of Advance Engineering and Research Development

Low Power Low Noise CMOS Chopper Amplifier

Design and Analysis of High Gain Differential Amplifier Using Various Topologies

Analysis of Instrumentation Amplifier at 180nm technology

Ultra Low Power Multistandard G m -C Filter for Biomedical Applications

ESTIMATION OF LEAKAGE POWER IN CMOS DIGITAL CIRCUIT STACKS

Design and Performance Analysis of Low Power RF Operational Amplifier using CMOS and BiCMOS Technology

A Complete Analog Front-End IC Design for ECG Signal Acquisition

A Literature Review on Leakage and Power Reduction Techniques in CMOS VLSI Design

DESIGNING OF CURRENT MODE INSTRUMENTATION AMPLIFIER FOR BIO-SIGNAL USING 180NM CMOS TECHNOLOGY

LEAKAGE POWER REDUCTION IN CMOS CIRCUITS USING LEAKAGE CONTROL TRANSISTOR TECHNIQUE IN NANOSCALE TECHNOLOGY

Nizamuddin M., International Journal of Advance Research, Ideas and Innovations in Technology.

Rail-To-Rail Output Op-Amp Design with Negative Miller Capacitance Compensation

A NEW APPROACH FOR DELAY AND LEAKAGE POWER REDUCTION IN CMOS VLSI CIRCUITS

A Compact Folded-cascode Operational Amplifier with Class-AB Output Stage

A Design of Sigma-Delta ADC Using OTA

Design of Rail-to-Rail Op-Amp in 90nm Technology

Analog CMOS Interface Circuits for UMSI Chip of Environmental Monitoring Microsystem

International Journal of Emerging Technologies in Computational and Applied Sciences (IJETCAS)

Design of Operational Amplifier in 45nm Technology

ISSN:

Performance Evaluation of Different Types of CMOS Operational Transconductance Amplifier

Design of High Gain Low Voltage CMOS Comparator

Low Power and Fast Transient High Swing CMOS Telescopic Operational Amplifier

DAT175: Topics in Electronic System Design

DESIGN OF LOW POWER SAR ADC FOR ECG USING 45nm CMOS TECHNOLOGY

LOW VOLTAGE / LOW POWER RAIL-TO-RAIL CMOS OPERATIONAL AMPLIFIER FOR PORTABLE ECG

CMOS Instrumentation Amplifier with Offset Cancellation Circuitry for Biomedical Application

A Low Power Single Ended Inductorless Wideband CMOS LNA with G m Enhancement and Noise Cancellation

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 02, 2016 ISSN (online):

Enhancing the Slew rate and Gain Bandwidth of Single ended CMOS Operational Transconductance Amplifier using LCMFB Technique

A Novel Low Noise High Gain CMOS Instrumentation Amplifier for Biomedical Applications

DESIGN OF LOW POWER OPERATIONAL AMPLIFIER USING CMOS TECHNOLOGIES

[Kumar, 2(9): September, 2013] ISSN: Impact Factor: 1.852

Design and Simulation of Low Voltage Operational Amplifier

G m /I D based Three stage Operational Amplifier Design

Design of Low Voltage Low Power CMOS OP-AMP

Design and Analysis of Low Power Two Stage CMOS Op- Amp with 50nm Technology

Design of a Sample and Hold Circuit using Rail to Rail Low Voltage Compact Operational Amplifier and bootstrap Switching

Cascode Bulk Driven Operational Amplifier with Improved Gain

Simran Singh Student, School Of ICT Gautam Buddha University Greater Noida

An 8-Channel General-Purpose Analog Front- End for Biopotential Signal Measurement

Advanced Operational Amplifiers

Radivoje Đurić, 2015, Analogna Integrisana Kola 1

A Compact 2.4V Power-efficient Rail-to-rail Operational Amplifier. Strong inversion operation stops a proposed compact 3V power-efficient

Design of High Gain Two stage Op-Amp using 90nm Technology

DESIGN AND SIMULATION OF CURRENT FEEDBACK OPERATIONAL AMPLIFIER IN 180nm AND 90nm CMOS PROCESSES

A CMOS Low-Voltage, High-Gain Op-Amp

CHAPTER 3 PERFORMANCE OF A TWO INPUT NAND GATE USING SUBTHRESHOLD LEAKAGE CONTROL TECHNIQUES

Improved PSRR and Output Voltage Swing Characteristics of Folded Cascode OTA

Chapter 5. Operational Amplifiers and Source Followers. 5.1 Operational Amplifier

An Improved Bandgap Reference (BGR) Circuit with Constant Voltage and Current Outputs

Sleepy Keeper Approach for Power Performance Tuning in VLSI Design

HIGH-BANDWIDTH BUFFER AMPLIFIER FOR LIQUID CRYSTAL DISPLAY APPLICATIONS. Saeed Sadoni, Abdalhossein Rezai

Design of High-Speed Op-Amps for Signal Processing

Performance Analysis of Low Power, High Gain Operational Amplifier Using CMOS VLSI Design

Low Power Op-Amp Based on Weak Inversion with Miller-Cascoded Frequency Compensation

High Voltage Operational Amplifiers in SOI Technology

V d = "1" if V in > V m. Fig 2: Frequency analysis of the PDM signal. Fig 1: PDM signal generation

DESIGN AND ANALYSIS OF SUB 1-V BANDGAP REFERENCE (BGR) VOLTAGE GENERATORS FOR PICOWATT LSI s.

ISSN: [Tahseen* et al., 6(7): July, 2017] Impact Factor: 4.116

DESIGN AND VERIFICATION OF ANALOG PHASE LOCKED LOOP CIRCUIT

A 24 V Chopper Offset-Stabilized Operational Amplifier with Symmetrical RC Notch Filters having sub-10 µv offset and over-120db CMRR

Design and Implementation of High Gain, High Bandwidth CMOS Folded cascode Operational Transconductance Amplifier

Rail to rail CMOS complementary input stage with only one active differential pair at a time

Design and implementation of two stage operational amplifier

A New Design Technique of CMOS Current Feed Back Operational Amplifier (CFOA)

Design and Simulation of an Operational Amplifier with High Gain and Bandwidth for Switched Capacitor Filters

Op-Amp Design Project EE 5333 Analog Integrated Circuits Prof. Ramesh Harjani Department of ECE University of Minnesota, Twin Cities Report prepared

A Low Power Low-Noise Low-Pass Filter for Portable ECG Detection System

Sensors & Transducers Published by IFSA Publishing, S. L.,

Design Analysis and Performance Comparison of Low Power High Gain 2nd Stage Differential Amplifier Along with 1st Stage

HIGH GAIN, HIGH BANDWIDTH AND LOW POWER FOLDED CASCODE OTA WITH SELF CASCODE AND DTMOS TECHNIQUE

A Low-Noise AC coupled Instrumentation Amplifier for Recording Bio Signals

Low Power Phase Locked Loop Design with Minimum Jitter

ECEN 474/704 Lab 7: Operational Transconductance Amplifiers

Design of Low Power Linear Multi-band CMOS Gm-C Filter

Design Analysis of 1-bit Comparator using 45nm Technology

ECEN 474/704 Lab 6: Differential Pairs

A Novel Approach of Low Power Low Voltage Dynamic Comparator Design for Biomedical Application

Comparative Study of Different Low Power Design Techniques for Reduction of Leakage Power in CMOS VLSI Circuits

Atypical op amp consists of a differential input stage,

Comparison between Analog and Digital Current To PWM Converter for Optical Readout Systems

DUAL ULTRA MICROPOWER RAIL-TO-RAIL CMOS OPERATIONAL AMPLIFIER

Design of a Capacitor-less Low Dropout Voltage Regulator

Low voltage, low power, bulk-driven amplifier

Topology Selection: Input

Design of Low Power Preamplifier Latch Based Comparator

DESIGN OF A FULLY DIFFERENTIAL HIGH-SPEED HIGH-PRECISION AMPLIFIER

Noise Tolerance Dynamic CMOS Logic Design with Current Mirror Circuit

A Novel Dual Stack Sleep Technique for Reactivation Noise suppression in MTCMOS circuits

Transcription:

I J C T A, 9(34) 2016, pp. 467-474 International Science Press Comparative Analysis of Leakage Power Reduction in Low Power Bio Instrumentation Amplifier Using 130nm MOSFET G. Sathiyabama 1 and S.Ranjith 2 ABSTRACT In day today life the biomedical instruments play very important role in bio signal acquisition. The bio instrumentation amplifiers are the most sensational part in bio instruments like electromyography, electrocardiography, and implantable pacemaker. Power dissipation is the challenging factor in design of bio instruments for signal recording. Thus there is requirement of bio amplifiers with low power consumption. In this project, ultra low power bio amplifier is designed with self biasing technique for bio medical application. However, with the continuous trend of technology scaling, leakage power is becoming a main contributor to power consumption. In order to reduce the leakage power in bio amplifier, the circuit is analysed with leakage power reduction techniques like sleepy keeper and feedback approach in folded cascode bio amplifier. The Bio amplifier is designed with high gain, better slew rate at 130nm technology. The proposed bio amplifier consumes less power compared to other existing two stage folded cascode and Folded cascode CMOS bio amplifiers. Keywords: Bio Amplifiers, Cacosde, Leakage Power, Slew rate, sleepy keeper, High gain. 1. INTRODUCTION Now a day, Bio medical instruments play a vital role in modern bio signal monitoring, recording and processing. The most commonly monitored bio-potential signals are electrical activity produced by skeletal muscles, electrical activity of the heart and electrical conductance of the skin, these signals are recorded with the help of the devices such as Electromyography (EMG), Electrocardiography (ECG or EKG) and galvanic skin response respectively. These devices are used to monitor the signals continuously and use bio-amplifier as their major component. Biomedical signal has very weak amplitude and low frequency, usually of few Millis volts or less and the Frequency below 1 KHz. While using high power there is more loss of power supply as signal has to be to record continuously. Designing a low power bio medical instruments is a challenging task. In normal signal acquisition system incudes electrodes/transducers, instrumentation amplifier, analog to digital converter, filter and display monitor. The electrodes are used to sense the signals inside the humans and these signals are amplified using amplifiers which mainly involve the bio amplifiers for further signal processing. Such bio potential signal value is very weak as compared to the noise floor and imperfection of the commonly used operational amplifiers (OPAs). These instrumentation amplifiers are bio-amplifier. Earlier the bio-amplifier is designed in many techniques. These techniques are designed with the use of low power CMOS, but those techniques have some disadvantages and do not get the targeted values as they expected. The disadvantages of those techniques are low CMRR, low Gain. Even though when there is an increase in Gain it leads to increase in the noise also the accuracy is not better. To improve the parameters such as gain, CMRR, PSRR, Bandwidth and supply voltage we need a new design technique. Designing an instrumentation amplifier with CMOS using folded cascode amplifier 1 Principal, Jeppiaar Engineering College, Chennai, E-mail: sathiyamadhu@gmail.com 2 Asst. Professor, Department of ECE, Jeppiaar Engineering College, Chennai, E-mail: gsrangith@gmail.com

468 V. Ramya and M. Ramakrishnan suitable for Bio medical application with increased gain, increased CMRR as specified for a good instrumentation amplifier. The Bio amplifiers used are generally designed using CMOS. In the modern CMOS technology there occurs problem in power leakage though the other parameters are up to satisfaction. Thus leakage reduction technique is required to reduce the power leakage such that it suits for the low power instruments [1]. 2. LEAKAGE POWER REDUCTION IN BIOAMPLIFIER Various folded cascode operational Transconductance amplifiers using different techniques such as self cascode of folded cascode operational Transconductance amplifier, two stage folded cascode CMOS opamp etc. These techniques are discussed and the various leakage reducing methods are studied. 2.1. Two Stage Folded Cascode Cmos Opamp Folded Cascode OTA is better operational amplifier architecture. Firstly, OTA designer occupies small overhead and folded structure allows a low supply voltage to systems where is embedded, and low current consumption. Secondly, the PMOS differential pair that converts the input voltage to current deals less noise compared with a NMOS differential pair [2]. Figure 1: Schematic of folded cascode CMOS opamp In addition, the folded cascode transistors structure deals to OTA amplifier good gain and higher output impedance; this is depend on dynamic parameters and which are improved by the cascade transistors structure. Finally, the folded cascode structure improved the excursion of common mode input range (CMR); it is compared with other structures such as telescopic OTA. The output voltage swing of Folded Cascode OTA structure is improves [3]. 2.2. Folded Cascode OTA Topology The input stage provides the gain of the operational amplifier. Due to the greater mobility of a NMOS device, PMOS input differential pair presents a lower Transconductance than a carrier NMOS pair. NMOS transistor has been chosen to ensure the largest gain required [4].

Mining Association Rules from Large Volumes of Data : A Survey 469 We opt for a folded cascode op-amp due to its large gain and high bandwidth performances. This circuit presents the strategy design of folded cascode OTA in the three operation modes of transistor: weak inversion, strong inversion and moderate inversion. So the goal to reach high gain and large bandwidth has been fulfilled but the leakage power is not reduced. 2.3. Folded Cascode Ota using Self Cascode Figure 2: Schematic of folded cascode topology A self cascode structure is used in low voltage design. The advantages in using self cascode structure is that it high output impedance. Figure 3: Schematic of folded cascode OTA using self cascode

470 V. Ramya and M. Ramakrishnan At input terminals self cascode is not used, but in the whole circuit self cascode is used because this whole circuit works as load. In this circuit each transistor is split into two so that upper transistors are working in saturated region while other is in linear region to work this circuit properly [7]. The regular cascode structures are avoided as their use increases the gain of the structure, but decreases the output signal swing. Self cascode is the new technique, which does not require high compliance voltage at output nodes. It is useful in low-voltage design. The main drawback of this circuit is it produces more power leakage [5]. 2.4. Low Power Reduction Technique The power may be of two types static power and dynamic power. Static power essentially consumed power when the transistor is not in the process of switching. Dynamic power is power consumed while the inputs are active. When inputs have ac activity, capacitances are charging and discharging and the power increases as a result. The dynamic power includes both the ac component as well as the static component. The rapid growth in semiconductor technology through the use of deep-submicron processes has led the feature sizes to be shrinking; thereby integrating extremely complex functionality on a single chip. In the ever increasing market of mobile hand-held devices used all over the world today, the battery-powered electronic system forms the backbone. To maximize the battery life, the tremendous computational capacity of portable devices such as notebook computers, personal communication devices (mobile phones, pocket PCs, PDAs), hearing aids and implantable pacemakers has to be realized with very low power requirements [6]. It has been shown that as the technology scales down below 100nm which is the shrinking of feature size of transistor, the channel length decreases, thereby increasing the amount of leakage power in the total power dissipated. As we can see as the technology is moving towards lower nanotechnology the subthreshold leakage increases thereby affecting the battery life. Thus there were various technique developed to deal with this problems [8] 2.5. Leakage Reduction Technique in Folded Cascode The Sleepy and the feedback leakage reduction techniques are the two methods that are implemented in the Folded cascode using self cascode amplifier [6]. 2.5.1. Sleepy approach Folded cascode using self cascode is modified with the introduction of leakage reducing technique such as the sleepy approach and feedback approach. In the Folded cascode using self cascode along with sleepy approach is designed by adding an PMOS in between the pull up network and v dd supply and an NMOS is added in between the pull down network and the v ss. the input to both PMOS and NMOS are provided in the form of pulse waveform. 2.5.2. Feedback method This method is also used for leakage reduction in Folded cascode using self cascode. This method includes an additional PMOS parallel to the NMOS in the pull down network and an additional NMOS parallel to the PMOS in the pull up network. The additionally added PMOS and NMOS base are connected to the outputs o1 and o2 respectively in the format of the feedback and they are connected parallel to the existing PMOS and NMOS with the same Pulse signal as the biasing. In sleep mode, this NMOS transistor is the only source of VDD to the pull-up network since the sleep transistor is off. An additional single PMOS transistor placed in parallel to the pull-down sleep transistor is the only source of GND to the pull-down network.

Mining Association Rules from Large Volumes of Data : A Survey 471 The leakage reduction in the sleepy technique is much perfect than the feedback approach by the analysis method and the simulation result of the existing Folded cascode method along with sleepy approach is done by using the HSPICE software and the parameters re measured using the cosmoscope and result analysis are made as a comparative tabulation that provides an clear idea about the best method that well suits for the leakage reduction in the low power application. 2.6. Leakage Reduction in Folded Cascode with Self Biasing The Folded cascode design is modified in such a way that the external biasing is avoided and self biasing is provided for each MOSFETs. The leakage reduction techniques are also included in the modified folded cascode using self cascade [9]. 2.6.1. Sleepy method This is same as the Folded cascode with external biasing, the only change is the biasing signal provided externally. The biasing is provided internally as self biasing. The biasing input to the Mosfet M3 is provided internally by connecting gate to the source side of the Mosfet. 2.6.2. Feedback method In this method, a small change in the biasing input to M3 which is provided internally by connecting gate to the source. The circuits are designed with the folded cascode with self cascode along with leakage reduction using two methods that includes the sleepy approach and feedback leakage reduction and also folded cascode with self biasing including the sleepy and the Feedback method of leakage reduction [10]. 3. SIMULATION AND RESULT ANALYSIS Earlier these circuits are designed using various CMOS technology. Here we are going to use 130nm CMOS technology using the software HSPICE. The circuits, two stage folded cascode amplifiers, Folded cascode with self cascode, folded cascode CMOS op amp are simulated and their corresponding results are discussed below. 3.1. Simulation Steps The comparative analysis of the various tcchiques are tabulated which implies the various technologies used for the design, their supply voltage, slew rate and power consumption. There does not involves the study of the power leakage that occurs while the supply voltage is reduced.this resultanalysis deals mainly with the power leakage problem that occurs and the methods implemented to reduce the leakage power [11]. Table 1 Performance analysis of various Bio amplifiers Parameters Folded cascode Two stage Folded cascode CMOS opamp folded cascode using self cascode CMOS opamp Technology 350nm 130nm 180nm 130nm 180nm 130nm Supply voltage 2V 1.8V 1V 1.8V 1.8V 1.8V Slew rate 3.3v/µs 1.851v/ms 196v/µs 1.082v/ms 16.3v/µs 1.537v/ms Power consumption 6.35mW 0.6nW 263mW 0.44nW 1.038mW 0.086nW Gain 67dB 63dB 67.7dB 95dB 60.96dB 90.75dB

472 V. Ramya and M. Ramakrishnan Table 2 Leakage power analysis and delay analysis of various design techniques Parameters Folded cascode Two stage folded Folded cascode using CMOS opamp cascode CMOS opamp self cascode Leakage power 1732pW 497.9pW 3.812pW Delay 1.9ms 3.469ms 9.6ms From the below, the analysis of the bio amplifiers with self biasing it is found that the gain for the folded cascode using self cascode with self biasing is 95.25dB which is 2.32% more than the two stage folded cascode opamp with self biasing and is 33.3 % more than the Folded cascode CMOS opamp. Thus the best circuit is chosen as the folded cascode using self cascode with self biasing [12]. Table 3 Performance Analysis of self biasing amplifiers in 130nm technology Parameters Folded cascode Two stage folded Folded cascode using CMOS opamp cascode CMOS self cascodeself self biasing opamp self biasing biasing Average power 162.3pW 27.71pW 0.2170pW Peak power 0.059mW 2.70mW 0.01732mW Bandwidth 7.3459KHZ 8.3829KHz 7.6176KHZ Frequency 50 50Hz 50.011Hz Slew rate 1.7533v/ms 1.0826v/ms 1.3522v/ms Delay 0.0192ms 3.46ms 0.0115ms Gain 60dB 92.3dB 95.25dB Table 4 Comparative Analysis of Folded cascode and its self biasing Folded cascade Parameters Folded cascode using Folded cascode using self self cascode cascode withself biasing Average power 0.86nW 0.2170nW Leakage power 3.812pW 25.35pW Peak power 16.3 µw 0.1732mW Bandwidth 78.01KHZ 7.6176KHz Frequency 50.011Hz 50.011Hz Slew rate 1537.9 1352.2 Delay 0.009ms 0.0113ms Gain 90.75dB 95.25dB 3.5. Proposed Folded Cascode with Self Cascode with Leakage Reduction The various leakage reduction techniques are induced in the Folded cascode with self cascode opamp. And their bandwidth, delay, transient analysis and AC analysis are obt ained using HSPICE software and COSMOSCOPE. The leakage can be reduced by sleepy approach and Feedback approach.

Mining Association Rules from Large Volumes of Data : A Survey 473 Table 5 Performance analysis of Folded cascode with sleepy and feedback leakage reduction techniques Parameters Folded cascode using Using sleepy Using feedback self cascode keeper Average power 0.8608nW 0.8241nW 0.7109nW Leakage power 3.812pW 2.385pW 1.302pW Peak power 16.3 µw 16.9 µw 16.3 µw Bandwidth 78.01 72.72 76.02 Frequency 50.01Hz 50.1Hz 50.1Hz Slew rate 1.5379v/ms 1.568v/ms 1.3509v/ms Delay 9.6ms 9.06ms 9.7ms Gain 90.75dB 90.7dB 90.75dB Table 6 Performance analysis of Folded cascode using self biasing with sleepy and feedback leakage reduction techniques Parameters Folded cascode using Using sleepy Using feedback self cascode with keeper self biasing (This work) Average power 0.2170nW 0.2641nW 0.2309nW Leakage power 25.35pW 23.85pW 23.02pW Peak power 0.1732mW 0.135 µw 0.163 µw Bandwidth 7.6176KHz 7.372KHz 7.802KHz Frequency 50.011Hz 50.1Hz 50.1Hz Slew rate 1.3522v/ms 1.5698v/ms 1.3509v/ms Delay 0.0113ms 1.9ms 2.9s Gain 95.25dB 95.7dB 95.2dB 4. CONCLUSION In this paper, ultra low power bio amplifier is designed with self biasing technique for bio medical application. The circuit of folded cascode CMOS opamp, folded cascode using self cascode, two stage folded cascode CMOS opamp are designed and simulated using HSPICE software and various parameters are measured using COSMOSSCOPE. By simulation, different parameters of the existing system such as average power, peak power, delay, bandwidth, frequency, slew rate and gain are measured and the best circuit is found out. Implementing the leakage reduction technique and comparing the parameters, it is found that the gain for the folded cascode bio amplifier is increased by 33.3% when designed at 130nm technology than at 180nm technology. The same amplifier with self biasing technique produces increased gain of 5.2% than in normal external biasing. This folded cascode is found to be good and in addition leakage reduction of sleepy approach is implemented in this amplifier that decreases the leakage power by 37.4%. In the case of feedback approach in comparison with the original folded cascode bio amplifier the leakage power is decreased by 45.4%.Thus by analysis it is concluded that the folded cascode amplifier with feedback technique is suitable for low power bio medical instruments. REFERENCES [1] Yu-Ming Hsiao,Miin-Shyue Shiau, Kuen-Han Li, Jing-Jhong Hou, Heng-Shou Hsu, Hong-Chong Wu, and Don-Gey Liu, Design a Bioamplifier with High CMRR, Hindawi Publishing Corporation VLSI Design Volume 2013, Article ID 210265, 5 pages.

474 V. Ramya and M. Ramakrishnan [2] Toihria I and Tixier T, Improved PSRR and Output Voltage Swing Characteristics of Folded Cascode OTA, International Journal of Electronics and Electrical Engineering, Vol. 3, Issue 4, August 2015. [3] Akshy goel,gurmohan singh, A Novel Low Noise High Gain CMOS Instrumentation Amplifier for Biomedical Applications, International Journal of Electrical and Computer Engineering (IJECE) Vol. 3, No. 4, August 2013, pp. 516~523 ISSN: 2088-8708 [4] H. Daoud Dammak, S. Bensalem, S. Zouari, and M. Loulou, Design of Folded Cascode OTA in Different Regions of Operation Through gm/id Methodology, International Journal of Electrical and Electronics Engineering 1:3 2008 [5] Ruchiyata Singh, A.S.M. Tripathi, A new approach for delay and leakage power reduction in CMOS VLSI circuits, International Journal of Advance Research In Science And Engineering, IJARSE, Vol. No.3, Issue No.5, May -2014. [6] Khushboo Kumari1, Arun Agarwa, Jayvrat, Kabita Agarwa, Review of Leakage Power Reduction in CMOS Circuits, American Journal of Electrical and Electronic Engineering, 2014, Vol. 2, No. 4, Pp. 133-136 [7] Swati kundra, priyankha soni, rhohaila naaz, Folded cascode OTA using self cascode technique, International Journal of Electrical and Electronics Engineering. [8] Jin-Yong Zhang, Lei Wang1, Bin Li (2009), Design of low-offset low- power CMOS amplifier for biosensor application, J. Biomedical Science and Engineering, 2009, Pp. 538-542 [9] Sonu Mourya, Pankaj Naik, Priyanka Sharma, Designing of Current Mode Instrumentation Amplifier for Bio-Signal Using 180nm CMOS Technology, International Journal of Engineering Research & Technology (IJERT), Vol. 2 Issue 4, April 2013 [10] Chung-Yu Wu and Chia-Shiung Ho, An 8-Channel Chopper-Stabilized Analog Front-End Amplifier for EEG Acquisition in 65-nm CMOS, IEEE Asian Solid-State Circuits Conference, November 9-11,2015 / Xiamen, Fujian, China [11] Vighnesh Rudra Das, Donald Y.C. Lie and Tam Nguyen, A Fully Integrated Low Noise CMOS Instrumentation Amplifier Design for Low-Power Biosensors, IEEE Conference paper, August - 2014. [12] Qinwen Fan, Student Member, IEEE, Fabio Sebastiano, Student Member, IEEE, Johan H. Huijsing, Life Fellow, IEEE, and Kofi A. A. Makinwa, Fellow, IEEE(2011), A 1.8 W 60 nv / Hz Capacitively-Coupled Chopper Instrumentation Amplifier in 65 nm CMOS for Wireless Sensor Nodes, IEEE Journal of solid-state circuits, vol. 46, no. 7, July 2011.