High Accuracy Spherical Near-Field Measurements On a Stationary Antenna

Similar documents
SPHERICAL NEAR-FIELD SELF-COMPARISON MEASUREMENTS

REFLECTION SUPPRESSION IN LARGE SPHERICAL NEAR-FIELD RANGE

A LARGE COMBINATION HORIZONTAL AND VERTICAL NEAR FIELD MEASUREMENT FACILITY FOR SATELLITE ANTENNA CHARACTERIZATION

ALIGNMENT SENSITIVITY AND CORRECTION METHODS FOR MILLIMETER- WAVE SPHERICAL NEAR-FIELD MEASUREMENTS

IMPROVING AND EXTENDING THE MARS TECHNIQUE TO REDUCE SCATTERING ERRORS

Sub-millimeter Wave Planar Near-field Antenna Testing

MISSION TO MARS - IN SEARCH OF ANTENNA PATTERN CRATERS

APPLICATIONS OF PORTABLE NEAR-FIELD ANTENNA MEASUREMENT SYSTEMS

PROBE CORRECTION EFFECTS ON PLANAR, CYLINDRICAL AND SPHERICAL NEAR-FIELD MEASUREMENTS

Accurate Planar Near-Field Results Without Full Anechoic Chamber

A COMPOSITE NEAR-FIELD SCANNING ANTENNA RANGE FOR MILLIMETER-WAVE BANDS

33 BY 16 NEAR-FIELD MEASUREMENT SYSTEM

Structural Correction of a Spherical Near-Field Scanner for mm-wave Applications

A TURNKEY NEAR-FIELD MEASUREMENT SYSTEM FOR PULSE MODE APPLICATIONS

ANECHOIC CHAMBER EVALUATION

RAYTHEON 23 x 22 50GHZ PULSE SYSTEM

PERFORMANCE CONSIDERATIONS FOR PULSED ANTENNA MEASUREMENTS

A CYLINDRICAL NEAR-FIELD VS. SPHERICAL NEAR-FIELD ANTENNA TEST COMPARISON

HOW TO CHOOSE AN ANTENNA RANGE CONFIGURATION

Accuracy Estimation of Microwave Holography from Planar Near-Field Measurements

A DUAL-PORTED PROBE FOR PLANAR NEAR-FIELD MEASUREMENTS

ADVANTAGES AND DISADVANTAGES OF VARIOUS HEMISPHERICAL SCANNING TECHNIQUES

Fiber Optic Device Manufacturing

ANECHOIC CHAMBER DIAGNOSTIC IMAGING

Upgraded Planar Near-Field Test Range For Large Space Flight Reflector Antennas Testing from L to Ku-Band

A TECHNIQUE TO EVALUATE THE IMPACT OF FLEX CABLE PHASE INSTABILITY ON mm-wave PLANAR NEAR-FIELD MEASUREMENT ACCURACIES

Keywords: cylindrical near-field acquisition, mechanical and electrical errors, uncertainty, directivity.

System configurations. Main features. I TScan SOLUTION FOR

METHODS TO ESTIMATE AND REDUCE LEAKAGE BIAS ERRORS IN PLANAR NEAR-FIELD ANTENNA MEASUREMENTS

An introduction to Mobile Station Over-the-Air measurements

SPHERICAL NEAR-FIELD MEASUREMENTS AT UHF FREQUENCIES WITH COMPLETE UNCERTAINTY ANALYSIS

HIGH ACCURACY CROSS-POLARIZATION MEASUREMENTS USING A SINGLE REFLECTOR COMPACT RANGE

A SIMPLE ANALYSIS OF NEAR-FIELD BORESIGHT ERROR REQUIREMENTS

Software. Equipment. Add-ons. Accessories. Services

Rapid Antenna Measurement Systems

Implementation of a VHF Spherical Near-Field Measurement Facility at CNES

Narrow Pulse Measurements on Vector Network Analyzers

Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs

A DUAL-RECEIVER METHOD FOR SIMULTANEOUS MEASUREMENTS OF RADOME TRANSMISSION EFFICIENCY AND BEAM DEFLECTION

Design and Manufacture of 8.4 m Primary Mirror Segments and Supports for the GMT

Advances in Antenna Measurement Instrumentation and Systems

AN AUTOMATED CYLINDRICAL NEAR-FIELD MEASUREMENT AND ANALYSIS SYSTEM FOR RADOME CHARACTERIZATION

A Multi-Robot Large Antenna Positioning System for Over-The- Air Testing at the National Institute of Standards and Technology 1

LEDGON 100. Goniophotometer. Two Global Leaders. One Complete Solution.

G. Serra.

Laser Trackers for Production of Automotive Tooling

IMPLEMENTATION OF BACK PROJECTION ON A SPHERICAL NEAR- FIELD RANGE

BROADBAND GAIN STANDARDS FOR WIRELESS MEASUREMENTS

Investigation of the Repeatability of the NA FEIC Beam Scanner: Status Report prior to the start of PAI Testing on FE#8

A LARGE SPHERICAL NEAR-FIELD ARCH SCANNER FOR CHARACTERIZING LOW-FREQUENCY PHASED ARRAYS

The CDT Ultra Wide-Band Anechoic Chamber. Félix Tercero, José Manuel Serna, Tim Finn, J.A.López Fernández INFORME TÉCNICO IT - OAN

Screw Driven automation tables

Smart off axis absolute position sensor solution and UTAF piezo motor enable closed loop control of a miniaturized Risley prism pair

OPTICS IN MOTION. Introduction: Competing Technologies: 1 of 6 3/18/2012 6:27 PM.

Study of Vee Plate Manufacturing Method for Indexing Table

Millimetre Spherical Wave Antenna Pattern Measurements at NPL. Philip Miller May 2009

A HILBERT TRANSFORM BASED RECEIVER POST PROCESSOR

M-041 M-044 Tip/Tilt Stage

Advanced Waveform Generator For Integrated Phased Array Testing

The Importance of Polarization Purity Author: Lars J Foged, Scientific Director at MVG (Microwave Vision Group)

GAIN COMPARISON MEASUREMENTS IN SPHERICAL NEAR-FIELD SCANNING

Antenna and RCS Measurement Configurations Using Agilent s New PNA Network Analyzers

MAKING TRANSIENT ANTENNA MEASUREMENTS

Aperture blockage in mechanically scanned multi-beam lens antenna for satellite communications in Ku band.

SPHERICAL NEAR-FIELD ANTENNA MEASUREMENTS: A REVIEW OF CORRECTION TECHNIQUES

Chapter 5. Array of Star Spirals

Near-Field Antenna Measurements using a Lithium Niobate Photonic Probe

The New ID11 Nanoscope end-station A Nano-Tomography Scanner

TRADITIONAL ANTENNA MEASUREMENTS AND CTIA OTA MEASUREMENTS MERGING THE TECHNOLOGIES

Agilent Antenna and RCS Measurement Configurations Using PNA Microwave Network Analyzers. White Paper

1000 LEAN SERIES VERTICAL GRINDING MACHINE

ESTIMATING THE UNCERTAINTIES DUE TO POSITION ERRORS IN SPHERICAL NEAR-FIELD MEASUREMENTS

Millimeter Spherical µ-lab System from Orbit/FR

MEASUREMENT OF THE EARTH-OBSERVER-1 SATELLITE X-BAND PHASED ARRAY

Helpful Alignment Tips for Machine Shops

Advanced Waveform Generator For Integrated Phased Array Testing

Design and Development of Novel Two Axis Servo Control Mechanism

Advanced Digital Receiver

Practical Considerations for Radiated Immunities Measurement using ETS-Lindgren EMC Probes

Novel Dual-Polarized Spiral Antenna

ACCURACIES OF VARIOUS GPS ANTENNAS UNDER FORESTED CONDITIONS

Advanced Positioner Control Techniques in Antenna Measurements

V2018 SPINSTAND AND NEW SERVO-8 SYSTEM

FORMATION FLYING PICOSAT SWARMS FOR FORMING EXTREMELY LARGE APERTURES

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

DIGITAL BEAM-FORMING ANTENNA RANGE

Step vs. Servo Selecting the Best

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

HScan. Horizontal Scanner

Antenna Measurement Uncertainty Method for Measurements in Compact Antenna Test Ranges

Military Radome Performance and Verification Testing Thomas B. Darling Vice President, Customer Support MI Technologies

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024

Estimating Measurement Uncertainties in Compact Range Antenna Measurements

Unit IV Drawing of rods, wires and tubes

INTRODUCTION The validity of dissertation Object of investigation Subject of investigation The purpose: of the tasks The novelty:

Locating Principles & Devices

Novel Multi-Beam Radiometers for Accurate Ocean Surveillance

60 GHz antenna measurement setup using a VNA without external frequency conversion

Vibration History. Pulp & Bleach Area. ips. Average Amplitude Velocity. Year

Advanced Dimensional Management LLC

Transcription:

High Accuracy Spherical Near-Field Measurements On a Stationary Antenna Greg Hindman, Hulean Tyler Nearfield Systems Inc. 19730 Magellan Drive Torrance, CA 90502 ABSTRACT Most conventional spherical near-field scanning systems require the antenna under test to rotate in one or two axes. This paper will describe a novel rolling arch near-field scanner that transports a microwave probe over a hyper-hemispherical surface in front of the antenna. This unique scanning system allows the antenna to remain stationary and is very useful for cases where motion of the antenna is undesirable, due to its sensitivity to gravitational forces, need for convenient access, or special control lines or cooling equipment. This allows testing of stationary antennas over wide angles with accuracies and speeds that historically were only available from planar near-field systems. The probe is precisely positioned in space by a high precision structure augmented by dynamic motion compensation. The scanner can complete a hyperhemispherical multi-beam, multi-frequency antenna measurement set of up to eight feet in diameter in less than one hour. 1. Introduction Nearfield Systems Inc. (NSI) has developed a new spherical near-field scanner, NSI-700S-300, that is capable of testing stationary antennas over wide angles with accuracies and speeds that historically were only available over narrow angles with planar near-field systems. The scanner is ideal for wide angle satellite and radar antenna testing. The planar near-field technique is often used for testing antennas of higher directivity (typically >15 dbi), and allows the antenna to remain in a fixed orientation. However, planar near-field scanning cannot provide good sidelobe coverage out to beyond about ±70. Spherical near-field measurement systems can avoid that limitation, but until now have required that the antenna be moved about one or both axes to accomplish the measurement. The NSI-700S-300 Arch Roll Spherical Near-field Scanner, has overcome this limitation, allowing high precision spherical near-field measurements beyond ±90 degrees, without the need to move the antenna (see Figure 1). The design challenges and chosen techniques for addressing these challenges will be reviewed and summarized in the paper. Keywords: Spherical Near-field, Accuracy, Position Correction Figure 1 - NSI-700S-300 arch roll spherical scanner

Figure 2 - Typical hyper-hemispherical near-field data measured on NSI-700S-300 The challenge was to design a spherical antenna measurement system that would allow fast and accurate electromagnetic field measurements for a stationary antenna by using only probe motion. The advantages of testing a stationary antenna include: The antenna can be measured in the orientation in which it will be used. This way antenna flexure due to a changing gravity vector does not corrupt the measured patterns. Test fixture support hardware costs for the antenna can be greatly reduced. For instance, expensive slip ring assemblies to support power & control cabling as well as thermal control supply lines are no longer necessary. The antenna alignment support equipment is much simpler and can be set up in the manufacturing assembly area, and simply rolled in to the test range without elaborate fixtures, mounting procedures, or alignment steps. 2. System Description The stationary antenna approach requires an electromagnetic field sensing probe that moves over a hyper-hemispheric surface enveloping the antenna (see Figure 2). The probe is precisely positioned in space by a high precision structure augmented by dynamic motion compensation. The scanner can complete a hyperhemispherical multi-beam, multi-frequency antenna measurement set of up to eight feet in diameter in less than one hour. The arch rotates continuously at 30 degrees per second during the measurement process. Figure 3 - NSI-700S-300 arch roll spherical scanner during factory testing The new Arch Roll scanner design not only eliminates the need for slip ring assemblies to the antenna, but simplifies the meticulous alignment procedure required for accurate measurements on traditional spherical near-field scanners. The design is ideally suited for satellite and radar antennas that require precision testing of a fixed antenna that cannot be moved or rotated during a test cycle. Other unique features of the Arch Roll Scanner include: * Precision encoders on the Theta and Phi rotation axes * A 4" travel radial stage for performing dynamic position correction, and for accommodating a variety of probes lengths. * Specially designed algorithms for dynamic probe position correction of the arch roll configuration that allow on-the-fly probe position correction to maintain a probe position accuracy on the order of 0.003 inches and 0.003 rms. * An RF subsystem that is capable of measuring thousands of frequencies and beam configurations. The NSI-700S-300 Arch Roll Spherical Near-field Scanner together with NSI s Panther 9000 RF subsystem and NSI 2000 antenna measurement software deliver spherical measurements with unprecedented accuracies and speeds.

The following table summarizes the mechanical axes on the system. Axis Travel Speed Resolution Theta ±95 2 /s 32 Phi 360 30 /s 27 Radial 4 0.5 in/s 08 Table 1 Mechanical Axes on Scanner 3. System Accuracy Requirement Spherical near field system alignment sensitivity to various alignment errors have been studied in [1] and [2]. The design requirements from NSI s customer were to position a microwave probe over a hyper-hemispherical surface to less than 0.003 rms in X, Y and Z. To achieve this accuracy, NSI designed the system to be based on a custom Phi rotation stage, combined with a rotating Theta Arch with ±95 probe travel. The Phi rotator is designed with two bearings at 36 spacing and radial runout on the order of only 3 which minimizes its contribution to the probe positioning accuracy. The Phi stage is mounted on top of an 8 tall pedestal to position its rotation axis at the center of the test range. Figure 5 Spherical adjustment fixture for mounting and aligning Theta structure to Phi stage The Theta structure was designed as two welded steel sections bolted together at the hub and then attached to the Phi stage. The structural analysis of the stage was conducted with Ansys, and optimized for best stiffness and minimum deflection. The C structure deflection due to its own weight are under under all orientations, and less than about fully loaded with rails, absorber, and the moving probe load. See Figure 6 for an example of the structure analysis for one of the unloaded cases. Figure 4 Phi rotator on pedestal To mount and align the large Theta C-shaped structure, a special set of XY translation and spherical shaped interface fixtures were designed as shown in Figure 5. This fixture allowed us to precision align the C-shaped structure in the 3 degrees of freedom required to meet the required intersection and orthogonality at the Theta-zero position. Figure 6 Theta Stage Structural Analysis The Theta carriage is designed to ride on the two curved bearings on either side of the Theta C structure, and is driven from one side with a stepper motor and gear reducer (Figure 7).

cluster of measurement points at 5 increments in theta and phi over the hemisphere Figure 7 Theta Carriage for Probe Motion 4. Design Challenges During assembly of the scanner, NSI made extensive use of a laser tracker to confirm system alignment tolerances could be met. Figure 8 shows the result of a check of the radius during factory assembly. The laser tracker software can show magnified color-coded highs and lows in the measured data, allowing assemblers to easily iterate the alignment to meet the requirement. In this case, the radius error over the full travel was adjusted to < 7 rms. Figure 8 Laser tracker metrology during system assembly & alignment The laser tracker is also used for the 2-dimensional system alignment and verification. Figure 9 shows the Figure 9 Laser tracker measurements over 360 Phi and ±90 Theta 5. Correction Technique To correct for expected manufacturing tolerances and gravitational deflections in the scanner structure, NSI implemented a dynamic correction scheme similar to those used in NSI s conventional planar near-field scanners, described in [3]. In the spherical near-field scanner case, we chose to implement a dynamic 3-axis correction model that adjusts the Radius, Theta and Phi axes on-the-fly while the scanner theta and phi axes are in motion. The laser tracker map of scanner errors was converted into a set of Position correction coefficients that are downloaded into the FPGA-based Panther Motion Controller for precision motion control. During the typical measurement process, the structure will be rotating in Phi at 30 /sec, with the Theta and Radius stages performing small correction moves dynamically as the structure rotates. The Panther receiver is triggered by the Phi angle target positions adjusted by the Phi encoder and Phi structure error corrections. This dynamic correction process eliminates the need to apply any post processing position corrections to the data, and yields the maximum accuracy in the RF test results. 6. Measured Results The measured results were obtained from a 5 spacing dataset in theta and phi, similar to that shown in Figure 9. The uncorrected data is shown in Figure 10 & Figure 11 for the radius error and the corrected data is shown in Figure 12 & Figure 13.

Radius lasertracker vs command Radius lasertracker vs command -95-85 -75-65 -55-45 -35-25 -15-5 5 15 25 35 45 55 65 75 85 95 Theta cmd (deg) -95-85 -75-65 -55-45 -35-25 -15-5 5 15 25 35 45 55 65 75 85 95 Theta cmd (deg) Figure 10 Laser tracker measurements of uncorrected Radius error over ±95 Theta for all Phi angles Figure 12 Laser tracker measurements of corrected Radius error over ±95 Theta for all Phi angles Radius lasertracker vs commmand Radius lasertracker vs commmand 0 90 180 270 360 Phi cmd (deg) 0 90 180 270 360 Phi cmd (deg) Figure 11 Laser tracker measurements of uncorrected Radius error over 360 Phi for all Theta angles Uncorrected Position Error R Theta Phi (in) (deg) (deg) p p 0.076 0.034 0.151 rms 0.005 0.018 Table 2 Uncorrected Position Error Figure 13 Laser tracker measurements of corrected Radius error over 360 Phi for all Theta angles Corrected Position Error R Theta Phi (in) (deg) (deg) p p 0.007 0.009 0.042 rms 0.001 0.002 0.003 Table 3 Corrected Position Error Similar results were archived in correcting the theta and phi errors. The resulting uncorrected and corrected errors are summarized in tables 2 & 3. All the error sources have been reduced significantly, and the Radius error has been reduced by an order of magnitude.

7. Summary This paper has summarized the advantages of the use of a novel spherical near-field scanner which allows the Antenna Under Test to remain stationary, and has also summarized some of the key design details of the scanner. The correction capability of the dynamic correction software has been demonstrated to reduce the probe position errors to less than 0.003 rms and also less than 0.003 rms over the entire hyper-hemispherical scanning surface. 8. REFERENCES [1] Newell, A. C., Hindman, G., "Quantifying the effect of position errors in spherical near-field measurements", In the proceedings of the 20th annual AMTA Meeting and Symposium, pp 145-149, Montreal, Canada, 1998. [2] Newell, A.C., Hindman, G. Stubenrauch, C., "The effect of measurement geometry on alignment errors in spherical near-field measurements", AMTA 21st Annual Meeting & Symposium, Monterey, California, Oct. 1999. [3] Hindman, G., Position Correction On Large Near- Field Scanners Using An Optical Tracking System AMTA 16th Annual Meeting & Symposium, Long Beach, California, Oct. 1994.