The School District of Palm Beach County Project Name SDPBC Project No. SECTION ( ) SIGNAGE PART 1 GENERAL 1.1 RELATED DOCUMENTS

Similar documents
SECTION SIGNAGE

SECTION IDENTIFYING DEVICES

*********************************************************************************************************

A. Submit properly identified manufacturer's literature before starting work.

SECTION IDENTIFYING DEVICES

SECTION IDENTIFICATION SIGNS. A. Plastic Signs, raised character, tactile, room identification, exit door signs, and non-tactile signs.

SECTION INTERIOR SIGNAGE

A. Submit manufacturer's technical data and installation for each type of sign required.

Americans with Disabilities Act (ADA) Federal Guidelines

SECTION NON-ILLUMINATED INTERIOR DISPLAY SYSTEM

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

DETAILED STILE AND RAIL WOOD DOOR SPECIFICATION

ARCHITECTS SUPPLEMENTAL INSTRUCTIONS (ASI)

SECTION BULLET- RESISTANT DOORS

A. Interior and exterior non-illuminated tactile building signs including Braille.

APPENDIX 6. SIGNAGE TYPES: Signage as manufactured by KROY Sign Systems, N. Hayden Road, Scottsdale AZ 85260

A. Product Data: For each electrical identification product indicated.

INTERIOR SIGNAGE MANUAL

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

SECTION INTERIOR SIGNAGE

Product Guide Specification

GRICE-TRIVERS JOINT VENTURE ARCHITECTS PAGE 1 PROJECT NO

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

B. Samples: For color, letter style, and graphic representation required for each identification material and device.

Music Area Casework General 1.01 Summary Related Sections Definitions Qualifications and Quality Assurance

Americans with Disabilities Act and Architectural Barriers Act Accessibility Guidelines

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 2

ETCHED PLAQUES by Matthews International

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

Design and Construction Standards SECTION ATHLETIC LOCKERS

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

SECTION ELECTRICAL IDENTIFICATION

A. It is preferred that all submittals to be submitted electronically in PDF format.

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

PROJECT LOCATION SECTION PREFINISHED STEEL DOOR FRAMES

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

SECTION HOLLOW METAL DOORS AND FRAMES

1.1. Any deviance from the following requirements must be approved during design by WVU Facilities Management.

Merrick Pet Care New Distribution Center Hereford, Texas

1. ASME A Scheme for the Identification of Piping Systems.

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

Guide Specification Section Interior Suspended Sliding Glass Doors

SECTION IDENTIFICATION OF HVAC PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

SECTION IDENTIFICATION FOR HVAC PIPING, DUCTWORK AND EQUIPMENT

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION CUSTOM CASEWORK

SECTION IDENTIFICATION FOR FIRE SUPPRESSION PIPING AND EQUIPMENT

Copyright 2017 AIA MasterSpec Premium 05/17 PRODUCT MASTERSPEC LICENSED BY ARCOM TO WEREVER PRODUCTS, INC.

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

Summary of Modifications/Changes in this Update

Piping & Equipment Identification

SCI-FAB Product Specifications. Casework Section 1. Part 1 General

UNIFIED FACILITIES GUIDE SPECIFICATIONS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

***************************************************************************************************************

SECTION Display Case Door Series 1301-CM

SECTION FASCIA INTERIOR FRAMED SIGNS & DIRECTORIES

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

50948-RHN Putney. 14 Dec This document includes: N14 General internal signage systems. Code Section Revision Dated

C. Installation shall be by experienced carpenters. Coordinate with plumbing and electrical contractors.

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU SIGNS SUPPLEMENTAL ACCESSIBILITY PLAN REVIEW CHECKLIST NO.

SECTION WOOD AND PLASTIC DOORS. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

BUILDING SIGN PROGRAM JULY 2012

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

B. American Society for Testing and Materials (ASTM):

SECTION IDENTIFICATION OF PLUMBING, PIPING AND EQUIPMENT. A. Section includes nameplates, tags, stencils and pipe markers.

INDEX OF SPECIFICATIONS SECTION F SPECIAL CONDITIONS DIVISION 1 - GENERAL REQUIREMENTS:

SECTION FOLDING GLASS PANEL PARTITIONS

A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable.

SECTION FRAMELESS GLASS SLIDING BI-FOLD SHOWER DOOR HARDWARE

Product Guide Specification

SECTION MECHANICAL IDENTIFICATION

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

SECTION FINISH CARPENTRY PART 1 GENERAL. 1.1 SECTION INCLUDES A. Interior Finish Carpentry Work: 1. Refer to schedule at end of Section.

MOVEABLE GLASS WALL TECHNICAL DATA

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Storage and Installation of welded LL Hollow Metal Door Frames in Steel Studs

CENTRAL MICHIGAN UNIVERSITY DESIGN STANDARD FOR INTERIOR CAMPUS SIGNAGE - JANUARY 23, 2017

SECTION MECHANICAL IDENTIFICATION

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

PHOTOPOLYMER BRAILLE RASTER BRAILLE MOLDED BRAILLE QUICK SHIP ADA BRAILLE SIGNS. Photopolymer sign panel in a variety of thicknesses.

.2 Accompany all submissions with a transmittal letter, in duplicate, containing:.4 Specification Section number for each submittal

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

BUILDING SIGN PROGRAM SEPTEMBER 2016

PALM SQUARE SHOPPING CENTER TENANT SIGN CRITERIA

Product Guide Specification For Nonrated & 20-Minute Rated Doors

Advisory Raised Characters. Signs that are designed to be read by touch should not have sharp or abrasive edges.

SECTION IDENTIFICATION FOR ELECTRONIC SAFETY AND SECURITY

SECTION LAP SIDING. A. Fiber cement lap siding, panels, single, trim, fascia, moulding and accessories.

Guide Specification Section Interior Aluminum Doors and Frames

CaseworkUSA. specifications. 1.1 General 1.2 Summary. 1.3 Related Sections. 1.4 Definitions. 1.5 Qualifications and Quality Assurance

P O S T E R C A S E S D I S P L A Y C A S E S M E S S A G E B O A R D S E X H I B I T C A S E S D I R E C T O R I E S W W W. P O B L O C K I.

Transcription:

PART 1 GENERAL 1.1 RELATED DOCUMENTS SECTION 10441 (10 14 00) SIGNAGE A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division-1 specification section, apply to work of this section. 1.2 SECTION INCLUDES: A. Tactile/raised letter plastic signs. B. Individual plastic characters signs. C. Signs of silk-screened characters on plastic. D. Required sign type: 1. Interior room, space and area ID signs. 2. International symbols of accessibility for accessible spaces and exits. 3. Accessible routes 4. Tactile exit signs 5. Hazard and safety signs 6. Evacuation plans 1.3 REFERENCES A. ANSI A117.1 - Specifications for Making Buildings and Facilities Accessible To and Usable By Physically Handicapped People B. FBC - Florida Building Code, Chapter 11 and Section 423.14.2 C. NFPA 101: 7.10.1.3 1.4 SUBMITTALS A. Submit shop drawings under provisions of Section 01300. B. Shop Drawings: Indicate sign styles, lettering font, foreground and background colors, locations, overall dimensions of each sign and anchorage. C. Sign Schedule: Provide complete interior and exterior sign schedule showing sign type, location, and verbiage. D. Samples: Submit two sample signs in size illustrating type, style, letter font and colors specified method of attachment. E. Manufacturer's Installation Instructions: Included installation template and attached devices. F. Colors: Colors shall be as selected by the Architect. 1.5 QUALIFICATIONS A. Manufacturer: Company specializing in manufacturing the products specified in this section with minimum three years documented experience. 1.6 REGULATORY REQUIREMENTS Architect s Project Number 10441 (10 14 00)-1 of 5 Signage

A. Conform to applicable codes for requirements for the physically handicapped, safety and egress. 1.7 DELIVERY, STORAGE, AND HANDLING A. Deliver, store, protect and handle products to site under provisions of Section 01600. B. Package signs, labeled in name groups. C. Store adhesive attachment tape at ambient room temperatures. 1.8 ENVIRONMENTAL REQUIREMENTS A. Do not install signs when ambient temperature is lower than recommended by manufacturer. B. Maintain this minimum temperature during and after installation of signs. PART 2 PRODUCTS 2.1 FLORIDA AMERICANS WITH DISABILITIES ACT REQUIREMENTS A. Manufacturer shall conform to tactile, Braille, letter size, and other requirements as required by Florida Accessibility Code for Building Construction and ANSI A117.1. B. ADA requirements supersede technical specifications in this Section. 2.2 MANUFACTURER A. Identifying devices shall be as manufactured by Andco Industries Corp., or approved equal. B. Products of the following manufacturers are acceptable providing their products equal or exceed the quality specified; and they can provide signs of the type, size, finish, letter style, and arrangement required. 1. ASI Sign Systems, Indianapolis, Indiana 2. Best Mfg., Montrose, Colorado 3. Baron Sign Company, Lake Park, Florida 4. Liberty Sign, Jupiter, Florida 5. Other pre-approved equal sign manufactures 2.3 BUILDING INTERIOR SIGNAGE A. General; applies to all signs except as noted: 1. Material shall be 1/8" clear matte acrylic stock with 3/8" radius corners. 2. Letters and background colors selected by Architect from manufacturer's standard colors. 3. Mounting: a. Shall be with adhesives and non-removable oval head screws. b. Mount at locations as directed by Architect. c. Mount at 60" above finished floor to the center of the sign. 4. Graphic Process: Provide raised (photopolymer process) or engraved letters and Braille molded part of the sign face, DO NOT use applied lettering. 5. Letters: a. Letters and numbers shall have width to height ratio between 3:5 and 1:1 and stroke width to height ratio between 1:5 and 1:10. b. Letters and numbers to be raised 1 / 32 " upper case sans serif font with Grade 2 Braille. c. Raised characters shall be 5/8" high minimum and 2" high maximum. Formatted: Highlight Formatted: Highlight Architect s Project Number 10441 (10 14 00)-2 of 5 Signage

d. Pictograms shall have the equivalent verbal description directly below the pictogram. 6. Characters and backgrounds must be matte or other non-glaze surface and of castrating colors. 7. All signs shall comply with chapter 11 FBC. B. Capacity signs: 1. For all rooms with a capacity of 50 persons or more as shown on the drawings or other rooms as indicated on the plans. 2. Furnish and install signage, 3" inch high by length required, reading "MAXIMUM CAPACITY". 3. Allow for 3 digits maximum after "maximum capacity", copy as shown on the drawings. C. Toilet Room Handicapped Signs 1. Furnish and install one sign depicting National Handicapped Symbol (wheelchair) at each toilet room, equipped with facilities for the handicapped. a. Size shall be 6" by 6". D. Room Name and Number Signs 1. Provide a sign for each room or space to include name and room number. a. Classroom and administrative office signs shall have a slot providing the owner the ability to add a teacher's name and change the name as necessary. b. Minimum size of 3" high by 6" minimum width for signs, longer where nomenclature demands. 2. Number shall be mounted as directed by Architect. 3. All spaces listed in Finish Schedule plus if more than one door is to a space, additional signs will be required one by number of doors to space. E. Storage Signs 1. Provide and install at mechanical and electrical rooms a sign mounted on the door to read as follows: "COMBUSTIBLE STORAGE NOT PERMITTED" 2. Signs shall be matte acrylic plastic, red background with white letters 3 high by width needed for copy and Braille, with 3/8" radius corners. 3. Mount on doors with non-removable oval head screws, verify number signs required. F. Fire Extinguisher, No Exit and Pull Station Sign 1. Copy to read: No Exit, "Fire Pull Station Inside", And "Fire Extinguisher Inside" 2. Red letters, same material, size and mounting as in A. General. 3. NO EXIT sign shall have letter size as per NFPA 101 section 7.10.8.3. 4. Braille sign not required for fire extinguisher. 5. See plans for locations. G. Stair Signs 1. Provide tactile signs at each doorway leading to exit stairway. 2. Wording on sign: "EXIT" H. Evacuation Plan 1. Provide frame for a graphic floor plan in each student occupied room. a. Size to be nominal 9" high by 12" in width. b. Provide a clear removable plastic cover over each sign. c. Sign cover will only be removable using a tool. 2. Mounting: a. Non-removable oval head screws, using rawl plugs where mounted on masonry. b. Architect shall supply the plans to the Contractor. 3. Frame Material: Matte acrylic plastic with all edges eased and tempered glass or clear plastic cover. I. Fire Rated/Smoke Partition Labeling Architect s Project Number 10441 (10 14 00)-3 of 5 Signage

1. Field label all fire rated walls above ceiling level, with fire rating shown on the construction plans. a. Provide minimum 1½" high block lettering stenciled on wall above finished ceiling, if in a storage, mechanical, electrical, or similar unfinished room, install at approximately 84" above floor. b. (Contractor to use rating from permit plans) HOUR FIRE RATED WALL, PROTECT ALL OPENING AND THROUGH WALL PENITRATION PER CODE REQUIREMENTS. 2. Field label all smoke partitions above ceiling level. a. Provide minimum 1½" high block lettering stenciled on wall above finished ceiling, if storage, mechanical, electrical, or unfinished room, install at 84" above floor. b. SMOKE PARTITION, PROTECT ALL OPENING AND THROUGH WALL PENITRATION PER CODE REQUIREMENTS. J. Mechanical, Electrical, Data, and Similar Rooms 1. Provide a sign saying "NO STORAGE" meeting the General requirements. 2. If these rooms have pair of doors, provide sign saying "THIS DOOR TO REMAIN CLOSED AND LATCHED TOP AND BOTTOM, EXCEPT DURING THE TRANSFER OF EQUIPMENT". a. Sign shall have 1" high block letters and be permanently attached (Attached in way as to maintain the rating of the door) to the inactive door near the latch side 60" from finished floor to center of sign. b. Braille not required for this sign. 2.4 BUILDING EXTERIOR SIGNAGE A. Emergency Access Opening 1. Provide and install at designated emergency access openings a sign mounted on the door to read as follows: "EMERGENCY ACCESS OPENING." 2. Signs shall be non-corrosive, 1/8 three ply laminate, UV inhibitors, non-glare surface, white background with red letters 3 high by width needed for copy. 3. Mount on doors with non-removable oval head stainless steel screws, verify number of signs required. 4. Graphic Process: Raised letters shall be an integral part of the sign face, do not surface apply any lettering. 5. Letters: Letters shall have width to height ratio between 3:5 and 1:1 and a stroke width to height ratio between 1:5 and 1:10. a. Letters shall be raised 1/32", upper case, and sans serif type. 6. Background must be matte or other non-glare surface. B. Exterior Building Letters and Street Numbers 1. Provide 15" high by ¼" thick non-illuminated letters as indicate on plans forming the school name. 2. Provide 12" high by ¼" thick non-illuminated letters on the building as indicate on plans forming the school's street address. 3. Letter style is Helvetica Medium 4. Use F-214 alloy aluminum welded construction of anodized clear satin finish with inlaid properly sanded and primed to receive type A10 baked enamel color as selected by the Architect and Owner from manufacturer's standard colors. 5. Install using manufacturers approved anchoring method to meet ASTM 7 wind load requirements. Architect s Project Number 10441 (10 14 00)-4 of 5 Signage

6. School name and street address shall be visible from the main road fronting the campus. PART 3 EXECUTION 3.1 INSTALLATION: A. Install all signs in strict accordance with manufacturer's instructions and FADA requirements. B. Room signs to be mounted 60" to center above finish floor on walls adjacent to the latch side of any door opening. 3.2 CLEANING: A. After installation, thoroughly clean all exposed surfaces and restore all damaged material to its original condition or replaced with new material. 3.3 WARRANTY: A. This Contractor shall fully guarantee all materials and labor under this section for a period of one (1) year from date of final acceptance of the building against all defects in both workmanship and materials and he shall promptly correct and/or replace such faulty work if so notified. END OF SECTION Architect s Project Number 10441 (10 14 00)-5 of 5 Signage