AIR FOIL CLUSTER CP5371 Drawing: 762252XX Rev: B Sheet: 1 of 5 Eng: CLD Date Drawn: 01/30/17
TYPICAL FIXTURE 2-3/4" MOUNTING HOLE CENTERS ARM 700 ARM COVER CENTER PLATE STRUCTURAL MOUNTING 50-1/4" CP5371 JUNCTION BOX (By Others) 2-3/4" MOUNTING HOLE CENTERS 1/4" MOUNTING HOLES (4) PLCS PER ARM 14-1/2" STRUCTURAL MOUNTING BLOCK ALL FIXTURES Drawing: 762252XX Rev: B Sheet: 2 of 5 Eng: CLD Date Drawn: 01/30/17 3. Structural blocking must be installed above the canopy system arms within the two structural blocking areas, capable of supporting a minimum of 500lbs, and centered around the junction box (by others). All (4) holes must be used in each arm (20 total). See pages 3 through 5 for additional installation instructions.
MOUNTING SCREWS (by others) FIXTURE SUPPORT CABLE OR STEM FIXTURE POWER CORD (CABLE HUNG FIXTURES ONLY) 3. 4. 5. 6. 7. 8. ARM FIXTURE SUPPORT BLOCK ARM COVER COUNTER SINK HOLES FACING DOWN MAIN COVER FIXTURE ACCENT SUPPORT CABLES MOUNTING HOLES ON TOP OF ARMS POWER CORD STRAIN RELIEF ACCENT SUPPORT GRIP LOCK Remove canopy system main cover. Remove canopy system arm covers. Position canopy system over junction box. Mark location of canopy system arm mounting holes (20) places, (4) per arm. Secure canopy system in place with mounting screws (by others). Minimum anchor size to be #12 x 3" wood screw. If supporting material is not wood, provide appropriate anchors. All 20 mounting hole locations must be used. Feed fixture support cables (1/8" diameter stainless steel cable) through hole in fixture support blocks (2) per arm or thread stems into fixture support blocks. Attach the support blocks to the fixture arms. Raise fixtures to canopy support system and attach to fixture support cables or stems. Make sure canopy system arm covers are fed through fixture support cables or stems and fixture power cord when used. See page 4 for additional instructions. Feed fixture power cord through power cord strain relief. Straighten cord and tighten strain relief. Make electrical connections. Re-install canopy system arm covers. Re-install canopy system main cover. Raise center accent to canopy system and support in place by inserting support cables (1/16" diameter stainless steel cables) into accent support grip locks. Level and trim cables. See page 5 for additional instructions. Drawing: 762252XX Rev: B Sheet: 3 of 5 Eng: CLD Date Drawn: 01/30/17
GRIP LOCK NOTE: LOOSEN LOCK COLLAR AND PUSH IN CABLE. DEPRESS BUTTON TO SLIDE CABLE OUT. TIGHTEN LOCK WHEN LEVELING IS COMPLETED GRIP LOCK (2) Raise each fixture to canopy support system and attach to fixture support cables. SEE GRIP LOCK NOTE ABOVE. Make sure canopy system arm covers are fed through fixture support cables and fixture power cord with countersink holes facing down. See page 3 for additional instruction. Make sure the fixture housings are level with one another once all of the fixture housing units are installed. POWER CORD FIXTURE SUPPORT CABLE FROM FIXTURE HOUSING Drawing: 762252XX Rev: B Sheet: 4 of 5 Eng: CLD Date Drawn: 01/30/17
SUPPORT GRIP LOCK PUSH CABLE INTO GRIP LOCK, DEPRESS BOTTOM TO REMOVE CABLE. LEVEL BY ADJUSTING CABLE IN GRIP LOCK. TRIM CABLE WHEN FINISHED LEVELING SUPPORT CABLES (5) SUPPORT CABLE HOLES SUPPORT CABLE Drawing: 762252XX Rev: B Sheet: 5 of 5 Eng: CLD Date Drawn: 01/30/17 Feed center accent cables through center accent support cable holes (1/16" cables with cable stop crimped on bottom of cable). Raise center accent to canopy system and support in place by inserting cables into grip locks (see grip lock note above). Level accent and trim cables when done.