Metrohm Dosing Test. Calibration of Metrohm dosing and exchange units

Similar documents
Mira M-3 Handheld Raman Spectrometer. On-site verification of materials in seconds

CERTIFICATE OF ACCREDITATION

Cal-Paks. Troemner UltraClass, ANSI/ASTM E617 Class 1 and OIML R 111 Class E2 and F1. Cal-Paks

DNVGL-CP-0212 Edition March 2016

Measurement instruments and procedures

Cenomic. Flexible full-volume bead mill. Innovations for a better world.

Hellenic Accreditation System. Annex F2/15 to the Certificate No SCOPE of ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

CALIBRATION & MEASUREMENT CAPABILITY 1 (CMC) (±) 0.5 C 0.05 C C 0.37 C 0.15 C 0.86 C C %Rh 0.95 %Rh 1.2 %Rh 0.085% IR 0.

Woven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out.

Effect of Washer Placement on Performance of Direct Tension Indicators

10.15 Scope of Accreditation

Application for Assessment of a full quality assurance system regarding Measuring Instruments in accordance with MID

Certificate of Accreditation

SYSTEM OF LIMITS, FITS, TOLERANCES AND GAUGING

For the National Voluntary Laboratory Accreditation Program

Performance Characteristics

CECIMO position on the applicability of the. Pressure Equipment Directive (97/23/EC) to machine tools

High Reliablity vs. COTS Oscillators APPLICATION NOTE QTAN 112

Forged parts for life.

More Info at Open Access Database by S. Dutta and T. Schmidt

Certificate of Accreditation

The surveillance test is a physical inspection of the product and a comparison with the specifications of the original type tested sample.

Dissolved Oxygen Analysis

Listing Report: AB Reissue Date: 01/21/16 This report is subject to annual review

For the National Voluntary Laboratory Accreditation Program

Where Art & Science Come Together.

Millikelvin Thermometers MKT 10 MKT 50

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Type Approval JANUARY The electronic pdf version of this document found through is the officially binding version

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

ISO 1042 INTERNATIONAL STANDARD. Laboratory glassware One-mark volumetric flasks. Verrerie de laboratoire Fioles jaugées à un trait

Baro Transmitter PTB x1.073

CORESTA Recommended Method No. 46

JB/T Translated English of Chinese Standard: JB/T

Series 01 Type 01, 02

XLS Electronic Pipettes

SPECIFICATIONS FOR A QUALITY LABEL FOR DECORATION OF COATED ALUMINIUM USED IN ARCHITECTURAL APPLICATIONS Edition

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Lotus Automation (Ireland) Ltd. Trading As. LotusWorks. Building 3, Finisklin Business Park, Sligo. Calibration Laboratory Registration number: 277C

Certificate of Accreditation

WATERFLUX 3000 Quick Start

Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 10

TECHNICAL INFORMATION P10/0513 vitroflex LED EDGELIGHT features

CERTIFICATE OF ACCREDITATION

001: 2007 CEB STANDARD

OPTIFLUX 5000 Technical Datasheet

TURBICUBE 1000 INSTRUCTIONS MANUAL. In-line turbidity transmitter TURBICUBE 1000 MES. From 0.1 to 1000 FNU. In-line turbidity transmitter /1

STATUTORY INSTRUMENTS SUPPLEMENT No th June, 2016 STATUTORY INSTRUMENTS SUPPLEMENT

C a t p h a n. T h e P h a n t o m L a b o r a t o r y. Ordering Information

(Non-legislative acts) DECISIONS

Additional requirements and conditions for abrasive products to be marked with the osa symbol

Lotus Automation (Ireland) Ltd. Trading As. LotusWorks. Building 3, Finisklin Business Park, Sligo. Calibration Laboratory Registration number: 277C

Optimizing feeding accuracy for your batch or continuous process

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SIEVE CERTIFICATION SYSTEM

ISO 534. Paper and board Determination of thickness, density and specific volume

Resistance thermometer Model TR30, compact design

NATIONAL BANK OF THE REPUBLIC OF MACEDONIA

Calibration Department Address Yard No 304 Road 4306 Block 343 Mina Salman Industrial Area Manama, Bahrain. 0 mm to 600 mm / 0.01 mm 7.

printcontrol Printing process control at a click of the mouse

Certificate of Accreditation

VERTICAL FORM FILL SEAL MACHINES

S20 The Compact for small precision components.

Technical Information Memosens CLS82D

WATERFLUX 3000 Quick Start

DNVGL-CP-0293 Edition July 2018

Joint ILAC CIPM Communication regarding the. Accreditation of Calibration and Measurement Services. of National Metrology Institutes.

IGT C1 Printability testers

Tested and ready to use Quality from a single-source

Pipetman Ultra 2-3. Pipetman Ultra Multichannel & D Diamond Tips Microman and Capillary Pistons 14-15

printcontrol Printing process control at a click of the mouse

6 Tips for Critical Sight Glass Applications

Certificate of Accreditation

No matter where you are.

Certificate of Accreditation

OPTIFLUX 5000 Technical Datasheet

AN ANALYSIS OF THE METROLOGY TECHNIQUES TO IMPROVE QUALITY AND ACCURACY

Vol. Validation of FTIR Systems AIM-9000 Infrared Microscope Infrared Microscope. Convenience of a Wide-View Camera

IS INTERNATIONAL STANDARD. Steel tubes - Continuous character marking and colour coding for material identification. First edition

Optimum control of the grinding process thanks to reliable in-process measurement. SHARING EXCELLENCE

Group of Administrative Co-operation Under the R&TTE Directive. 5 th R&TTE Market Surveillance Campaign on WLAN 5 GHz

Accreditation No: LAB 131. AL-MEEZAN INDUSTRIAL METROLOGY SERVICES House No. 22, Block C, Sabzazar Scheme Lahore Pakistan

Sarasota CM200 Sarasota HME900 Density Converter Electronics

METRIC TT-B-1325C June 1, 1993 SUPERSEDING TT-B-1325B April 25, 1978 FEDERAL SPECIFICATION BEADS (GLASS SPHERES) RETRO-REFLECTIVE

ODOT ITB Group 4 Item 33 Qty. 1

GENERAL DESCRIPTION OF THE CMC SERVICES

ITEM 644 THERMOPLASTIC PAVEMENT MARKING

To Develop a Quality Control/Quality Assurance Plan For Hot Mix Asphalt. AASHTO PP qq

ISO INTERNATIONAL STANDARD. Welding Studs and ceramic ferrules for arc stud welding

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

REDEEM AT. Buy 1 Case of 33 Expansion Vials with Black Phenolic Caps and PTFE-faced White Rubber Liners, Receive 1 FREE Case

Melting point range. A complete range of melting points to accomodate all users

AUTOMATED INSPECTION SYSTEM OF ELECTRIC MOTOR STATOR AND ROTOR SHEETS

This document is a preview generated by EVS

Certificate of Accreditation

MIL- B Rev NAVSEA 0900-LP

Liquid & Gas Flowmetering

Touch Probe Cycles itnc 530

Transcription:

Metrohm Dosing Test Calibration of Metrohm dosing and exchange units

Used every day and always accurate... 02 Everyday use Your Metrohm dosing or exchange unit operates reliably day in, day out, or even overnight if so configured. It al ways dispenses an exact volume. The cylinder is filled with titrant before the sequence starts again. The Metrohm Dosing Test The Metrohm Dosing Test has been developed to deal with this situation: your dosing or exchange unit is periodically inspected to verify that its accuracy and precision are still within the required tolerances. You base your decisions on the results obtained because you know that you can rely on the values delivered by your Metrohm titration system. Furthermore, the Metrohm Dosing Test is carried out by specially trained Metrohm Service Engineers at your workplace using recognized standards and procedures. But are these values absolutely reliable? Yes they are, provided that your Metrohm dosing or ex change unit is new, or has been regularly serviced. Like any instrument exposed to chemicals or which has moving parts, or both in the case of a Metrohm buret, it may become less accurate over time. The Metrohm Dosing Test can be conducted during an nual servicing of the instrument, either as a component of a Metrohm Care Contract or «on demand» to mi nimize disruption to your laboratory workflow. Alcoholic KOH, for example, attacks the glass cylinder and can thus alter its inside diameter. Intensive use of the internal buret or just simply aging may also compromise the performance of the measuring system.

... for very demanding requirements Piston burets have very demanding requirements with respect to accuracy and precision of the dosed volumes, as defined in ISO standard 8655-3:2002 «Piston-operated volumetric apparatus Part 3: Piston burettes» and in U.S. Pharmacopeia USP 35-NF 30, General Chapter <31> «Volumetric Apparatus». When they leave factory, Metrohm burets fulfill these strin gent requirements without exception, as confirmed by the corresponding quality certificate. This means you can rely on the accuracy and precision of your piston buret right from the start. The Metrohm Dosing Test checks that these requirements are still being fulfilled in your daily operations and confirms continuous compliance with the respective standards. 03 Maximum permissible errors for motor-driven piston burets according to ISO 8655-3:2002: Tolerances for burets according to N.I.S.T. Class A (ASTM E287-02): Nominal Maximum permissible errors volume systematic random ml ± µl ± µl 1 6.0 1.0 2 10 2.0 5 15 5.0 10 20 7.0 20 40 14 50 100 25 Designated 10 volume («micro» 25 50 ml type) Subdivisions, ml 0.02 0.1 0.1 Limit of error, ml 0.02 0.03 0.05

One test method for every requirement The Metrohm Dosing Test is based on a gravimetric The accuracy of the results depends not only on exact 04 method. This means that the dispensed water is weighed determination of the mass, but on other parameters as and the volume dosed is then calculated using the specific density of water. The calculated dosed volume is and the ambient air as well as the barometric pressure. well. These are primarily the temperature of the water sub sequently compared to the displayed volume. This is why the Metrohm Service Engineers are equipped with calibrated thermometers and barometers. Procedure according to ISO 8655-6 In the procedure specified in the standard «ISO 8655 6:2002 Piston operated volumetric apparatus Part 6: Gravimetric methods for the determination of measurement error», three different volumes are used in the test: 10% of the nominal cylinder volume 50% of the nominal cylinder volume 100% of the nominal cylinder volume Ten individual measurements are carried out for each of these three volumes. The test liquid is water conforming with grade 3 as specified in ISO 3696. The systematic and the random measurement errors are calculated from the measured values. Metrohm Dosing Test, cumulative procedure The general conditions of the Metrohm Dosing Test correspond to those of standard ISO 8655 6:2002. Details of the test conditions, the test procedure, and the calculations are given in Metrohm Application Bulletin 283/1 e. In the cumulative procedure, the test volumes are dispensed from one cylinder filling without any refilling. The smallest test volume is exactly 10% of the cylinder volume, the largest is exactly 100%. The remaining 8 test volumes are randomly selected from the range between these two limits. This procedure ensures that the entire volume range of the buret is covered. The linearity of the dosed volume can thus be reliably checked.

Metrohm Dosing Test, repetitive procedure In the repetitive procedure of the Metrohm Dosing Test, one test volume is dispensed and then the cylinder is refilled. Each dosing thus starts with a cylinder that is completely full. 05 Customer-specific Dosing Test The Customer specific Dosing Test is carried out in accordance with the procedure and general conditions specified in standard ISO 8655 6:2002. However, customers can select the following parameters: The selected test volume can be any value between 10% and 100% of the nominal cylinder volume. The number of repeated measurements can vary between 3 and 10, and this number can be varied for the individual test volumes. This enables compliance with customer specific requirements, e.g. those specified in an SOP. Choosing the appropriate test procedure Procedure according to ISO 8655 6 Metrohm Dosing Test, cumulative procedure Metrohm Dosing Test, repetitive procedure Customer specific Dosing Test Your advantages Official procedure according to an internationally recognized standard Based on ISO 8665 6:2002 Checks the entire volume range Quickest procedure Based on ISO 8665 6:2002 Checks the entire volume range Simulates practical conditions Complies with the requirements of your SOP The buret can be checked in the volume range you need

Stay on the safe side 06 The Dosing Test gives you certainty the certainty that your Metrohm buret is dispensing the displayed value. This in turn gives you assurance that you really can rely on your results, and that this will not cause problems during auditing. Once the Metrohm Dosing Test has been successfully completed, you will receive the corresponding certificate. This certificate confirms clearly and traceable that your buret continues to comply with the requirements as verified by the test, as well as the reference instruments used in the test. In short, you can focus on your work knowing that you can rely 100 percent on the accuracy of your Metrohm buret.

Good to know The test includes inspection and maintenance of your Metrohm buret Every Metrohm Dosing Test includes inspection and maintenance of your Metrohm buret. Titrando. The piston stroke of 50 mm or 80 mm is di vi ded into 10,000, respectively, 20,000 increments. 07 The Metrohm Service Engineer checks the piston, cylinder, valve disc, connecting tubes, and other components for any signs of damage or wear, and then cleans and lubricates the parts as necessary. If the buret no longer complies with the requirements, the Metrohm Service Engineer can replace the correspon ding components directly on-site and then repeats the Dosing Test. Inspection and maintenance of your drive unit (Dosino, Titrino, Titrando) The exchange unit or the dosing unit and the buret drive form a unit, and the complete system is checked during the Dosing Test. The drive unit itself is also a high-precision instrument, re gardless whether it is a Dosino, a Titrino or even a Needless to say, this stroke is directly related to the dosed volume. If the drive unit deviates from the spe cifi cations, it directly compromises the result of the Dosing Test. Inspection and maintenance of your drive is thus worthwhile for several reasons: No unpleasant surprises during the Dosing Test. Error-free function of the drive unit, not only during the Dosing Test itself, but also during operation. Maximum flexibility in combining the drive unit with an exchange unit resp. a dosing unit. Provided that all of your exchange, dosing, and drive units have been calibrated, any ex change or dosing unit can be combined with any drive unit. Legend: Subsidiary Independent Distributor

Subject to change Layout Ecknauer+Schoch ASW, printed in Switzerland by Metrohm AG, CH-9100 Herisau 8.000.5088EN 2013-02 www.metrohm.com