Product Data Sheet 6314/2TDHP. The engineer's choice

Similar documents
Product Data Sheet 8214 J/2H4P. The engineer's choice

Product Data Sheet 8452/2HHP. The engineer's choice

Product Data Sheet 8452/2 GHHP

Product Data Sheet 6424/2HP-210

Product Data Sheet 3254 J/2H3P

Product Data Sheet RG160-28/18N/2TDPU-331

Product Data Sheet 8214 J/2H4P

Product Data Sheet 3252J/2H3PU

Product Data Sheet RER190-39/14/2TDMO

Product Data Sheet 622/2HHP-021

Product Data Sheet DV4112/2NP-201

Product Data Sheet RER220-43/18/2TDMO

Product Data Sheet RER225-63/18/2TDO- 406

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

-1 ] temperature life [V]

EC centrifugal fan - RadiCal

EC centrifugal fan. forward-curved, dual-intake with housing (flange)

B1793 AC Blower Innovation in Motion

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

NEW PRODUCT INFORMATION

EC centrifugal fan. forward curved, single inlet with housing (flange)

EC centrifugal fan - RadiCal

DC axial compact fan

CONTENTS 1. SCOPE 3 2. ELECTRICAL 3 3. MATERIAL 4 4. MECHANICAL NOISE MEASUREMENT RELIABILITY PRODUCT LABEL...

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan - RadiCal

SPECIFICATION FOR APPROVAL

2-02 Start voltage The voltage that enable to start the fan by sudden switch on.

92 38 mm. Reversible Flow Fan. 9RF type. Features. Common Specifications. Specifications. Reduces the required number of fans

9WL type. Rated current Rated input. Rated speed [min -1 ]

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

EC centrifugal fan. backward curved, single inlet

NEW PRODUCT INFORMATION

Specification For Approval

175 mm 69 mm Specifications

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan G3G250-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. forward curved, dual inlet with housing (flange)

Specification For Approval

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Specification For Approval

CUSTOMER: ARCERA EU MODEL NO: 9225 (CeraDyna Fan) PART NO: FD1290-AP181E3AL DATE: CUSTOMER APPROVAL. Taiwan. Page 1 of 12 REV.

DC Axial Fans. ebm-papst St. Georgen. Ball Bearings. Noise

EC centrifugal fan. forward curved, dual inlet with housing (flange)

Cross Flow Fans. Additional Information. Cooling Fans. Introduction E-85 MF Series E-88 MFD Series E-92

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

SPECIFICATION FOR APPROVAL

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

WL Product Range Performance Comparison

AC axial compact fan

EC centrifugal fan. R3G175-AF25-02 backward curved, single inlet. Nominal data

EC centrifugal fan. forward curved, dual inlet with housing (large flange)

AC diagonal compact fan

EC centrifugal fan. forward curved, dual inlet with housing (flange)

DB Motorized Impeller

AC axial compact fan

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

DC Axial Fans. ebm-papst St. Georgen. Noise

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan - RadiCal

DB Motorized Impeller

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

MODEL: M2DYS SEN TRONIC AG

Rotary Measurement Technology Incremental Encoders

SPECIFICATION FOR APPROVAL

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

EC centrifugal fan. backward curved, single inlet

SPECIFICATION FOR APPROVAL

Centrifugal Fan Product Range

Power supply CP-E 24/2.5

Power supply CP-D 24/4.2 Primary switch mode power supply

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

RoHS. High shaft load capacity. Shock / vibration resistant

AC centrifugal fan - RadiCal

DB Motorized Impeller

Low Cost, Small Package, 120VAC Microstepping Drive

V: Very low speed, E: Extra low speed, L: Low speed, M: Middle speed, H: High speed, S: Super High speed, U: Ultra High speed, T: Top High speed

Specification For Approval

onlinecomponents.com

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

Power supply CP-D 24/1.3

Tangential blowers with multiple housings. Optimized air flow steady distribution.

Vert-X 37-5V. Applications Agricultural machines Construction machines Forest machines Special purpose vehicles

AC centrifugal fan. backward curved

Power supply CP-E 24/0.75

Power Supplies 3. SDN-C Compact DIN Rail Series

AC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

Vert-X 28HD - 24V / V. Applications Harvester Public transport Construction machines

Power supply CP-D 12/2.1

VF-nC1 Adjustable Speed Drive Engineering Specification

Power supply CP-E 24/20.0

Refrigerated Products Brochure. USA Edition

Transformers, Power Supply Units and Socket Outlets

Transcription:

Product Data Sheet 6314/2TDHP The engineer's choice

6314/2TDHP INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Electrical Interface - Input... 5 3.2 Electrical Operating Data... 6 3.3 Electrical Interface - Output... 7 3.4 Electrical Features... 8 3.5 Aerodynamics... 11 3.6 Sound Data... 12 4 Environment... 12 4.1 General... 12 4.2 Climatic Requirements... 12 5 Safety... 13 5.1 Electrical Safety... 13 5.2 Approval Tests... 13 6 Reliability... 13 6.1 General... 13

1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position - shaft Fan Counterclockwise Air outlet over struts Ball bearing Any 2 Mechanics 2.1 General Depth Diameter Mass Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size 51,0 mm 172,0 mm 0,875 kg Metal Plastic Wire outlet corner: 600 Ncm Remaining corners: 600 Ncm ISO 4762 - M4 degreased, without an additional brace and without washer 2.2 Connections Electrical connection Lead wire length Tolerance Tube length Tolerance Wires L = 365 mm S = 10 mm Wire size (AWG) 22 Insulation diameter 1,7 mm +- 10,0 mm +- 2,0 mm Wire Color Operation 1 red + UB 2 blue - GND 3 violet PWM 4 white Tacho 06/19/2017 page 3 of 14

The auxilliaries shown on the schematic diagram (which are required for the intended use) are not part of our delivery. 06/19/2017 page 4 of 14

3 Operating Data 3.1 Electrical Interface - Input Control input PWM Features Inpute type PWM - Frequency Input frequency range Open collector typical: 2 khz 1 khz - 20 khz Characteristics Schematics The shown pull-up resistor to the internal reference voltage (+5V) has 4.7kOhm. Speed control: By Puls width modulation (PWM) 0...100% 06/19/2017 page 5 of 14

Open collector in relation to signal-ground. Information to the curve: 0 % - 7% PWM: 0 1/min 7 % PWM: 1.000 1/min (Fan on, comming from 0% PWM) 7 % - 10% PWM: 1.000 1/min (corresponding to min. speed) 10 % - 90% PWM: linear increasing curve 90 % - 100% PWM: 5.500 1/min (corresponding to max. speed) 7 % - 5 % PWM: linear decreasing curve (comming from 100% PWM) 5 % PWM: 800 1/min or 0 1/min (Fan off, comming from 100% PWM) Transistor requirements: Vce max. >= 12V; Isink max. >=5mA Vce sat. <= 0,15V 3.2 Electrical Operating Data Measurement conditions: Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; Motor axis horizontal; warm-up time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area should not be any solid obstruction within 0,5 m. p = 0: corresp. to free air flow (see chapter aerodynamics) I: corresp. to arithm. mean current value Name Condition PWM 0001 PWM: 95 %; f: 2 khz 100% PWM or broken lead wire (open control input) Features Condition Symbol Values Voltage range U 16 V 36 V Nominal voltage U N 24 V Power consumption p = 0 20,5 W 41 W 38 W P +- 10 % +- 10 % +- 10 % Tolerance PWM 0010 Current consumption p = 0 1.280 ma 1.700 ma 1.055 ma I +- 10 % +- 10 % +- 10 % Tolerance PWM 0010 Speed p = 0 4.500 1/min 5.500 1/min 5.500 1/min n +- 7,5 % +- 5 % +- 5 % Tolerance PWM 0010 06/19/2017 page 6 of 14

3.3 Electrical Interface - Output Tacho type /2 (open collector) Features Note Values Tacho operating voltage U BS <= 60,0 V Tacho signal Low U S low I sink: 2 ma <= 0,4 V Tacho signal High U S high I source: 0 ma 60,0 V Maximum sink current I sink <= 20 ma External resistor External resistor Ra from UBS to US required. All voltages measured to GND. Tacho frequency (6 x n) / 60 Tacho isolated from motor No Slew rate => 0,5 V/us n = revolutions per minute (1/min) Please note: At zero speed the tacho signal is at a static HIGH. It will be also HIGH when the fan is still spinning, but the speed control signal is set to zero speed already. The tacho signal is only activated after the start-up is completed. 06/19/2017 page 7 of 14

3.4 Electrical Features Electronic function Reversed polarity protection Max. residual current at U N Locked rotor protection Locked rotor current at U N Clock signal at locked rotor Speed-Controlled P-CH FET I F <= 5 ma Auto restart I block t 3 / t 4 typical: 2,7 s / 10,0 s First locked rotor off time is reduced to 3 seconds. After 4 unsuccessful start up trys the fan will be turned off for 40 seconds.. This fan has a startup delay of 2 seconds after applying supply voltage. Start-up current @ 24 V (I = 500mA/div ; t = 2s/div) 06/19/2017 page 8 of 14

Running current @ 24 V (I = 500mA/div ; t = 1ms/div) Locked rotor current @ 24 V (I = 0,5A/div ; t = 1s/div) Locked rotor current @ 16 V (I = 0,5A/div ; t = 1s/div) 06/19/2017 page 9 of 14

Locked rotor current @ 36 V (I = 0,5A/div ; t = 1s/div) Internal Fuse: Littelfuse Nano2 Fuse Very Fast-Acting 451/453 Series 7A / 125V 06/19/2017 page 10 of 14

3.5 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft horizontal. The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions. a.) Operation condition: 5.500 1/min at free air flow PWM 95 %; f: 2 khz Max. free-air flow ( p = 0 / = max.) 600,0 m3/h Max. static pressure ( p = max. / =0) 655 Pa 06/19/2017 page 11 of 14

3.6 Sound Data Measurement conditions: Sound pressure level: 1 meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 db(a) For further measurement conditions see chapter aerodynamics. a.) Operation condition: 5.500 1/min at free air flow PWM 95 %; f: 2 khz Optimal operating point Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 505,0 m3/h @ 123 Pa 7,2 bel(a) 63,0 db(a) 4 Environment 4.1 General Min. permitted ambient temperature TU min. -20 C Max. permitted ambient temperature TU max. 75 C Min. permitted storage temperature TL min. -40 C Max. permitted storage temperature TL max. 80 C 4.2 Climatic Requirements Humidity requirements Water exposure Dust requirements Salt fog requirements humid heat, constant; according to DIN EN 60068-2-78, 14 days None None None Permitted application area: The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided. Pollution degree 1 (according DIN EN 60664-1) There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact. Please require severity levels and specification parameters from the responsible development departments. 06/19/2017 page 12 of 14

5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25 C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25 C measured with U=500 VDC for 1 min. Clearance / creepage distance Protection class 500 VAC / 1 Min. 500 VAC / 1 Sec. RI > 10 MOhm 1,0 mm / 1,2 mm III 5.2 Approval Tests CE EC Declaration of Conformity No EAC Eurasian Conformity Yes UL Underwriters Laboratories Yes / UL507, Electric Fans VDE Association for Electrical, Electronic and Information Technologies Yes / Approval acc. to EN 60950 (VDE 0805) - Information technology equipment CSA Canadian Standards Association Yes / C22.2 No. 113 Fans and Ventilators CCC China Compulsory Certification Not applicable The approval tests are observed to: U approval max.:36,0 V @ TU approval max.: 70,0 C 6 Reliability 6.1 General Life expectancy L10 at TU = 40 C Life expectancy L10 at TU max. Life expectancy L10 acc. to IPC 9591 at TU = 40 C 70.000 h 35.000 h 117.500 h 06/19/2017 page 13 of 14