Quick Start Guide AT-6000 Advanced Wire Tracer Series

Similar documents
AT-7000 Advanced Wire Tracer

UAT-600 Series. amprobe.com

DM-5 Power Quality Analyzer

AT-5000 Professional Underground Cable / Pipe Locator System

AT-4000 Advanced Tracer User s Manual

2011 / Circuit Tracer

AT-4000 Series. Advanced Wire Tracer. Users Manual

SureTest Circuit Tracers Instruction Manual

SURETRACE CIRCUIT TRACER YOUR IDEAL TROUBLESHOOTING SOLUTION. DESIGNED TO FIND EVERYTHING, WHILE SAVING YOU TIME AND MONEY.

POWER TRACE TM TASCO, INC.

cable and pipe locators RD Utility cable and pipe locator

TRIAD SERIES 2310 SC

I N N O V A T I N G U N D E R G R O U N D L O C A T I N G

AMP-25 AMP-25-EUR. Mini-Clamp TRMS AC / AMP-25. ZERO 2 Sec

Circuit Breaker Finder

CS-8000 Circuit Seeker. Circuit Tracer Rastreador de circuito Détecteur de circuit INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES MANUEL D INSTRUCTIONS

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

Pipe Laser Model No Instruction Manual

For detailed specifications and ordering info go to

Pathfinder. Instruction Manual for: PF620 Circuit Tracer Kit

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

Cable Locator Transmitter/Receiver Model 6681

HAWK5000 Operators Manual

FLEXIBLE CURRENT PROBES

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

vlocpro NEW Features & Accessories NEW Standard Features available now! New Displays

AT Underground Cable/Pipe Locator System. Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso Användarhandbok

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Fluke 712B and 714B Temperature Calibrators

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Hand-held temperature calibrator Model CEP3000

G R E G E D WA R D S

Utility cable and pipe locator

Ariadna CI MV & LV cable identifier

Dynatel 2250E/2273E Advanced Cable and Fault Locator

MS2030 CAT III 600 V A V AUTO RS232

SEL Phase Comparison Faulted Circuit Indicator (PC FCI) Communicates to line crews using the. Features and Benefits

SureTest Circuit Analyzers

UTILITY LOCATING EQUIPMENT

Ariadna Instruments. Power cable identifier & LV live network phase and feeder identifier

Fluke 3540 FC Three-Phase Power Monitor

Fluke and

Testing & Measurement. FEATURED Products. SF-780 Metal Locator. NEW-CM450 True RMS Clamp Meter. NEW AM-6 Analog Multimeter

Insulation Testers and Earth Ground Testers

vscan Data Sheet V1.0

T5-600/T Electrical Tester

Armada Technologies Pro900 Advanced Underground Locator USER GUIDE

Armada Technologies Pro900 Advanced Underground Locator USER GUIDE

Practical Instrument Electronics. PIE 311 Diagnostic RTD & Milliamp Calibrator. Best RTD & Milliamp Calibrator on the market!

HT COMBI419. Innovative meter designed to perform all safety test

The first installation safety tester with automated testing based on patent pending AUTO SEQUENCE.

Fluke 370 FC Series true-rms wireless AC/DC clamp meters

User's Guide. AC Circuit Load Tester. Model CT70

DynatelTM Cable Locator. Operators Manual. October Revision A

AT Advanced Wire Tracer. Users Manual

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

Utility cable and pipe locator

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

SureTest Model ST-1THD & ST-1THDC Instructions

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity.

DM-III MULTITEST Power Quality Recorder

Testing & Measurement

Obsolete Document. Dynatel

Flexible AC current probes

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

Fluke Three-Phase Power Recorder. Never miss capturing a disturbance - with the exclusive threshold-free measurement system, it s automatic.

Measure voltage without test leads. Product Highlights

4-range High voltage insulation resistance tester KEW 3126

Fluke 3540 FC Three-Phase Power Monitor

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

AC/DC Current Probes Model MR411 Model MR521

INSULATION TESTER SERIES Selection guide

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Armada Technologies Pro800D Hi-Power Wire and Valve Locator. Operating Instructions

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

GFL-1000 User Manual Ground Fault Locator

1650 Series Multifunction Installation Testers

Electrical Measurement Safety. Sponsored By:

1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

CABLE TESTER. Models CA7024, CA7026 & CA7028. Call toll free (800) or visit

Amp Clamp W/True RMS

Leica Digisystem Safe and fast location of underground services

Cable I.D. Live. Primary or Secondary In or Out of the Trench TX-Former to TX-Former TX-Former to Meter Energized or Grounded.

Innogaz Electrofusion Systems

Nocturne+ E INSTRUCTIONS CAUTION. Motor Operated Exterior Projection Screen. 1¾ (45mm) END CAP. Wall Mounting Bracket. Wall Mounting Bracket

Locator Accessories DATA SHEETS. Accessory Range for Pipe & Cable Location Equipment

Installation / Monitoring Technique

79/26 Series III Multimeter

PV200. Why buy the PV200? The most compact I-V curve tracer around.

Wide-band Models from DC to 100 MHz

Techno Instrumentation(India) Pvt. Ltd. Manufacturer of underground power cable fault locators

Testing & Measurement

10.00 (1/2) PAC series

Portable equipment for insulation fault location for unearthed and earthed systems (IT and TN systems) to be used in conjunction with or without an

LED Driver Compact fixed output

Model 7000 Low Noise Differential Preamplifier

Transcription:

Quick Start Guide AT-6000 Advanced Wire Tracer Series Immediate, clear breaker identification Tested by Fluke and safety certified by 3rd party labs Intuitive transmitter automatically senses whether the system is energized or de-energized Most accurate wire tracing in its class with eight sensitivity modes 75 Amprobe info@amprobe.com Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623) 208 Amprobe For detailed specifications and ordering go to amprobe.com 60052 A

AT-6000 Advanced Wire Tracer Series - Quick Guide Quick Guide Table of Contents. Tracing Energized and De-energized Wires Quick Scan Mode Precision Tracing Mode 2. Identifying Breakers and Fuses Breaker Tracing 3. Non-Contact Voltage () and Passive Tracing Passive Tracing Verify if a wire is Energized 4. Special Application: Finding Shorts 5. Special Application: Finding Breaks 6. Special Application: Metal Conduit 7. Wire tracer specifications and kit contents AT-6000 Advanced Wire Tracer Special Applications: GFCI-protected circuit wire tracing Find breaks, openings, and shorts Trace wires in metal conduit Trace non-metallic pipes and conduits Trace shielded wires Trace underground wires Trace low voltage wires and data cables Sort bundled wires Map circuits using test leads connection Trace breakers on system with light dimmers CT-400 signal clamp (AT-6030 kit) to improve accuracy and performance when there is no access to bare conductors See the user manual for further instructions regarding special applications.

Tracing Energized and De-energized Wires Test Leads Quick Scan Mode Use this mode to easily follow the direction of a wire. Proper connection with separate ground Signal not detected Signal detected. Connect the green and red test leads to the. 2. Plug the socket adapter onto the receptacle and connect the red lead to the Energized hot wire. The signal will only be transmitted between the load-side to which the is connected and the source of power. 3. Connect the green wire to a separate ground. 2. Turn on the Receiver. It will automatically start in Quick Scan Mode. 2. Scan the target area with the Tip Sensor to find a signal, then begin tracing the detected wire. Increase or decrease sensitivity of the Receiver by pressing + or - on the keypad as necessary. Precision Tracing Mode Use this mode to precisely pinpoint the wire, within " accuracy. Blinking Precision tracing mode indicator showing signal in GH mode. Turn on the. 2. Verify that the test leads are properly connected; the red LED voltage status light should be on for circuits with voltage above 30 V AC/DC, and it should be off for De-energized circuits below 30 V AC/DC. 3. Select GH signal mode by pressing, LED display will quickly begin to blink.. Turn on the Receiver. Press the MODE button until the Precision Tracing function is selected. 2. Scan the target area with the Tip Sensor to find the highest signal level. While tracing, periodically adjust sensitivity to keep the signal strength near 50. Increase or decrease sensitivity by pressing + or - on the keypad. If the signal is too strong for precise locating, change the to W mode. Amprobe info@amprobe.com Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623) 208 Amprobe For detailed specifications and ordering go to amprobe.com 60052 A

AT-6000 Advanced Wire Tracer Series - Quick Guide Identifying Breakers and Fuses Test Leads 2 Blinking indicator showing signal in GH mode Proper connection with separate ground Separate ground connection (Preferred). Turn on the. 2. Verify that the test leads are properly connected; the red LED voltage status light should be on for circuits with voltage above 30 V AC/DC, and it should be off for De-energized circuits below 30 V AC/DC. 3. Select GH signal mode by pressing. LED display will quickly begin to blink. Breaker Tracing Simplified direct connection. Connect the green and red test leads to the using either simplified direct connection or separate ground connection. Separate ground connection (preferred): first connect the red lead to the Energized hot wire on the load side of the system. The signal will ONLY be transmitted between the outlet to which the is connected and the source of power. Simplified direct connection: connect the test leads directly to the hot and neutral wires. While locating a breaker, wires will not be traceable as the signals will cancel each other out. 2. Connect the green lead to a separate ground. Align the tip sensor groove with the breaker. Turn on the Receiver and continue pressing the MODE button until Breaker Locating mode is selected. 2. Align the groove on the Tip Sensor with the breaker lengthwise. 3. Scan all breakers in any order. Breakers can be scanned multiple times. It records the highest signal level and will automatically adjust sensitivity. The Receiver may beep and the green arrow may light up several times during this step. 4. Locate the breaker by scanning all breakers again; the Receiver should indicate only one breaker. 2

Non-Contact Voltage () and Passive Tracing Receiver Passive Tracing mode. Scan the target area with the Tip Sensor to find the highest signal level. 2. While tracing, periodically adjust the sensitivity to keep the signal strength near 50. 3. Increase or decrease sensitivity by pressing + or - on the keypad. Verify if a wire is Energized. Turn on the Receiver. 2. Continue pressing MODE button until the Non-Contact Voltage () function is selected. Note: The is not used in mode. Use this mode to scan for any energized wires with passive tracing or to verify if a specific wire is energized.. Hold the Receiver with the Tip Sensor against the wire. 2. For precise pinpointing of hot wire versus neutral wire, increase or decrease sensitivity by pressing + or - on the keypad. Amprobe info@amprobe.com Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623) 208 Amprobe For detailed specifications and ordering go to amprobe.com 60052 A 3

AT-6000 Advanced Wire Tracer Series - Quick Guide Special Application: Finding Shorts 2 Receiver Precision tracing mode Verify the Loop LED is ON.. Connect the with the test leads to the circuit. 2. Hold down the GH button for two seconds to activate Loop mode.. Turn on the Receiver 2. Press the MODE button to select a wire tracing mode (either Quick Scan or Precision Tracing). Wire tracing mode: Tracing a cable to find shorts. Start tracing the cable until the signal stops. 2. Verify the place of the fault: move the to the other end of the wire and repeat tracing from the opposite end. If the signal stops at the exact same location the fault has been located. Note: This method will be affected by signal cancellation effect. Expect a relatively weak signal. 4

Special Applications: Finding Breaks 2 Receiver Precision tracing mode indicator showing signal in GH mode. Ensure the wire is De-energized. 2. Connect the with the test leads to the circuit.. Turn on the Receiver. 2. Press the MODE button until the Precision Tracing function is selected. 3. Select GH signal mode by pressing. Precision tracing mode: Tracing a cable to find breaks or opens. Start tracing the cable until the signal stops. 2. Verify the place of the fault: move the to the other end of the wire and repeat tracing from the opposite end. If the signal stops at the exact same location the fault has been located. Note: For best results, ground all De-energized wires that run in parallel with the black test lead. Amprobe info@amprobe.com Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623) 208 Amprobe For detailed specifications and ordering go to amprobe.com 60052 A 5

AT-6000 Advanced Wire Tracer Series - Quick Guide Special Application: Metal Conduit Test Leads Receiver Precision tracing mode Proper connection with separate ground. Connect the green and red test leads to the. 2. Plug the socket adapter onto the receptacle and connect the red lead to the Energized hot wire. The signal will only betransmitted between the load-side to which the is connected and the source of power. 3. Connect the green wire to a separate ground. 2 Blinking. Turn on the Receiver. Press the MODE button to select a wire tracing mode (either Quick Scan or Precision Tracing). Tracing). Tracing Wires in Metal Conduit. Open junction boxes and use the Receiver Tip Sensor to detect which wire in the junction box is carrying the signal. 2. Move from junction box to junction box to follow the path of the wire. Important Notes: Applying a signal directly to the conduit will send the signal through all the conduit branches, making tracing a particular conduit path impossible. indicator showing signal in GH mode The Receiver is unable to pick up the signal from a wire through a metal conduit. The metal conduit will completely shield the tracing signal. The Receiver will be able to detect wires in a non-metallic conduit. For these applications follow general tracing guidelines.. Turn on the. 2. Verify that the test leads are properly connected; the red LED voltage status light should be on for circuits with voltage above 30 V AC/DC, and it should be off for De-energized circuits below 30 V AC/DC. 3. Select GH signal mode by pressing, LED display will quickly begin to blink. 6

Specifications AT-6000-R Receiver CT-400 Signal Clamp Display size LCD 2.5 in (6.35 cm) LEDs Display dimensions (W x H).45 x.93 in (36.72 x 48.96 mm) Display resolution 240(RGB) x 320 pixels Display type TFT-LCD (262 K) LEDs Display color True, 6bit/color Operating mode LEDs: red Battery status LEDs: green, yellow, red Booting time < 3 sec < 2 sec Backlight Operating temperature -4 F to 22 F (-20 C to 50 C) 32 F to 22 F (0 C to 50 C) Operating humidity 45%: -4 F to <50 F (-20 C to <0 C) 95%: 50 F to <86 F (0 C to <30 C) 75%: 86 F to <04 F (30 C to <40 C) 45%: 04 F to 22 F (40 C to 50 C) 95%: 50 F to <86 F (0 C to <30 C) 75%: 86 F to <04 F (30 C to <40 C) 45%: 04 F to <22 F (40 C to <50 C) Storage temperature and humidity -4 F to 58 F (-20 C to 70 C), <95% RH Operating altitude 0 to 656 ft (2000 m) Transient protection 6.00 kv (.2/50μS surge) Pollution degree 2 IP rating IP 52 IP 40 Drop test 3.28 ft ( m) Power supply 4 x AA (alkaline or NiMH rechargeable) 8 x AA (alkaline or NiMH rechargeable) Power consumption (typical) Battery life 0mA Approx. 6 h Hi/Lo mode: 70 ma Loop mode with Clamp: 90 ma Consumption without signal transmission: 0 ma Hi/Lo mode: approx. 25 h Loop mode: approx. 8 h Low battery indication Fuse.6 A, 700 V, fast-acting, Ø 6x32mm Maximum conductor Size.26 in (32 mm) Dimensions (L x W x H) Approx. 7.2 x 2.95 x.69 in (83 x 75 x 43 mm) Approx. 7.2 x 3.66 x.97 in (83 x 93 x 50 mm) Approx. 5.9 x 2.75 x.8 in (50 x 70 x 30 mm) Weight Approx..25 lb (0.57 kg) Approx. 6.8 lb (2.8 kg) Approx. 0.25 lb (0.4 kg) Certifications NOTE: Refer to user manual for ADPTR-SCT and TL-6000 specifications. Included in Wire Tracer Kits AT-6020 AT-6030 AT-6000-R Receiver TL-6000 Test Lead and Accessory Kit CC-6000 Hard Carrying Case User Manual 2 - Rechargeable Batteries (not installed) 3 - Battery Chargers CT-400 Signal Clamp (Optional) 2 -.5 V AA (IEC R6) Batteries (not installed) (charger and batteries are not available to order separately) AT-6020 AT-6030 Amprobe info@amprobe.com Fluke Corporation, Everett, WA 98203 Tel: 877-AMPROBE (267-7623) 208 Amprobe For detailed specifications and ordering go to amprobe.com 60052 A 7

Amprobe Division of Fluke Corp. 6920 Seaway Blvd. M/S 43F Everett, WA 98203 USA amprobe.com P 877-AMPROBE (267-7623) 208-209 Fluke Corporation. All rights reserved. Printed in the U.S.A. 600956B Specifications subject to change without notice.