Measuring Instruments. Measuring Instruments

KE-N80. Item: kg/pc unit Item No. KE-N80 three phase Energy Meter for direct connection 80A 0, DIN rail 35mm

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

COUNTIS E23. Three-phase energy meter Direct - 80 A MODBUS. Instruction manual. en/countis-e2x

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

ENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID

Energy Management Energy Meter Type EM340

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Technical Data Sheet. x1000. kwh R Y B

Energy Management Energy Meter GM3T E GM3T-RS485 E

3-phase meter with direct connection and pulse or Modbus RS485 output

Energy Management Energy Analyzer Type EM112

Energy Management Energy Analyzer Type EM210 MID

Universal-Transducer Multi-E11-MU

Energy Management Energy Analyzer Type EM111

Data Sheet. RISH Master Record %THD

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Digital Multifunction Instrument - Rish Master 3440

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Centrale de mesure Power Meter PM500 Merlin Gerin

PLA 33. Power line analyzer. User and service manual. version 2.4

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

Energy Management Energy Meter Type EM21 72R Retro-Fit

COUNTIS E25/E26 Three-phase active energy meter 63A direct M-BUS

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Operating Guide October 2006

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

Energy Management Energy Meter Type EM111

Energy Management Energy Meter Type EM112

METRAClip87 and 88 Clamp Multimeters

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03

MID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN

Multifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port

Energy Management Energy Analyzer Type EM210

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

Energy Management Energy Meter Type EM110

Single phase meter with direct connection and pulse or Modbus RS485 output

Introduction DIN rail mounted electricity meters

UPM209 1/5A CT, 80A Multifunction three-phase meter

N30P DIGITAL PANEL METER

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

EM-72 Electricity Meters for Current Transformers

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Contents. Introduction and description Package contents Device identification PM Options... 80

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Technical Data Sheet AMIK 300 / 301

Single phase energy meter with Serial Modbus interface

Energy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming

ULTRA RAPID POWER QUALITY ANALYZER

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Energy Management Three-phase energy meter with output modules Type EM4-DIN

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

Measuring centers MC3x0 series Energy Meters with Power Display Energy Meter WQ0217 & WQ1217 Energy Meter with analogue pointer WQ0207 & WQ2207

Environmental Influences. Display. Inputs and Outputs. Electromagnetic Compatibility. Communication Interfaces. Insulation Strenght.

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202

Power Meter Series PM3200 Functions and characteristics

METRAClip85 and 86 Clamp Multimeters

Power analyzers and Energy Meters Power Analyzer Type WM14-96

MultiCube Multi-Function Electricity Meter. Installation and Operation

POWER NETWORK MEASUREMENTS Analysers, Multimeters & Transducers

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Energy counting and measurement

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Current Clamp. 210

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

Energy Management Energy Meter Type EM110

AMIK 200 / 201 Technical Data Sheet

UMG 103-CBM. Universal measurement device for DIN rails

Transformers, Power Supply Units and Socket Outlets

3-Phase Energy meter with serial S-Bus interface

PEM353. Universal measuring device

MBus Interface for Energy and Power meters AEM and APM

Side view View from below Rear view

3 phase energy meters with integrated Serial Modbus interface

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

Transcription:

ADP3-0C Digital display symbols for all three phases: I - U-PF -Hz -P- Q-S, active energy export/import by IR side set up communication Power-meters three-phase Direct connection 0 A Application The new digital power-meters with green backlight LCD display, made forafast and correct reading, are ideal instruments for installation in distribution panels, where user can easily read and control more quantities for the three phases. They are also used to measure the energy of three phases systems, for example in residential, generic and industrial applications. They are provided with two outputs: one for active imported energy, the other one for active exported energy. The products can be set up to communicate with LAN TCP/IP, Modbus RTU, M-Bus, EIB-KNX and SD-Card Datalogger. Interfaces are used to analyze the energy-consumption to reduce the running cost toaminimum for Industrial plants and buildings like Offices, Hospitals, Universities etc. ADP3-0C Imp/ Function Display Unit ID Current A L, L, L3 Tensions related V L-N, L-N, L3-N Tensions between phases V L-L, L-L3, L3-L Power factor PF L, L, L3 Frequency Hz L Active power (k-m) W Utilization and instantaneous value L, L, L3 Reactive power (k-m) var Utilization and instantaneous value L, L, L3 Apparent power (k-m) VA Utilization and instantaneous value L, L, L3 Active energy Tariff (M)-(K) Wh Energy absorbed or supplied L Connection errors PHASE Err Primary transformer 5....000/5 A CT (current transformer) Communication modules

Display Liquid crystal display with illuminated green background Line in use (L /L-L3- L) Inductive power on L Capacitive power on L Measured value Measured value Energy /Power import (absorbed Imp ) Energy /Power export (supplied Exp ) Running tariff Power factor Frequency Capacitive power on L Inductive power on L Line in use (L /L-L3) Units Line in use (L3 / L3-L) Inductive power on L3 Capacitive power on L3 4 standard module housing, suitable for DIN rail mounting Connection through CT.../5 A till.000/5 A Sealable terminal covers Precision control LED Terminals SO pulse outlet Backlighting makes display easy to read Optic control IR for external communication Up Down Menu Button OK Supply terminals CT connection 5 to.000 A

ADP3-0C Imp/ Direct connection 0 A Overview These multimeters are ideal instruments for installation in distribution panels, where user can easily read and control more quantities for the three phases. They are provided with two outputs: one for active imported energy, the other one for active exported energy. Liquid crystal display with illuminated green background can monitor all three phases For direct connection 0 A, or for transformer.../5 A For transformer primary current of 5 A to.000/5 A. Input is in 5 A increments Detection of connection errors (phase transposition) Accuracy class precision for the current, voltage Accuracy class precision and power and energy active according toen 5040-3 (B) Accuracy class precision for the reactive power according to EN 6053-3 Version without pulse output (cod. ECSPM-ECSPM06) Version withpulse output (cod. ECSPM4 - ECSPM) Version with pulse output and set up for communication (cod.ecspm3-) - ( pulse output for export energy) - ( pulse output for import energy) Two pulse / selection for model cod. ECSPM- Front LED pulses per selection for model cod. ECSPM- Energy register zero setting Energy register for import and export 4 DIN modules wide ( mm) Technical data Data in compliance with EN 5040-, EN 5040-3, EN 6053-3 and EN 6053-3 ECSPM -ECSPM4 ECSPM06 -ECSPM ECSPM3 direct connection 0 A CT connect. till.000/5 A General characteristics Housing DIN 430 DIN 4 modules 4 modules Mounting EN 605 35 mm DIN rail DIN rail Depth mm 0 0 Reference standard active energy - EN 5040--3 EN 5040--3 reactive energy - pulse output EN 6053-3-3 EN 6053-3-3 Operating features Connectivity to single/three-phase network n wires -4 4 Storage of energy values and configuration internal flash memory - yes yes Tarif for active energy - Tarif Tarif Supply Rated control supply voltage Un VAC 30 30 Operating range voltage V 4... 6 4... 6 Rated frequency fn Hz 50 ±% 50 ±% Rated power dissipation (max. for phase) Pv VA (W) (0.6) (0.6) Overload capability Voltage Un continuous; phase/phase V 40 40 second: phase/phase V 00 00 continuous; phase/n V 6 6 second: phase/n V 300 300 Current Imax continuous A 0 6 momentary (0,5 s) A - 0 momentary ( ms) A 400 - Display (readouts) Connection errors and phase out discernible from phase-sequence indic. - PHASE Err PHASE Err Display type LCD - Energy n digits (... 3 decimal) (... 3 decimal) LCD - Largeness instantaneou n digits 4 (... 3 decimal) 4 (... 3 decimal) digit dimensions mm xmm 6.00 x 3 6.00 x 3 Active energy: display, digit tariff Wh 0.0 0.0 + display import or export (arrow) overflow MWh.. Instantaneous active power: 3 display, 3-digit W, kw or MW 000.... 000.... Instantaneous reactive power: 3 display, 3-digit var, kvar or Mvar 000.... 000.... Instantaneous apparent power: 3 display, 3-digit VA, kva or MVA 000.... 000.... Instantaneous tariff display, -digit - T T Transformer primary current A - 5....000 Display period refresh s Measuring accuracy Active energy and power acc.to EN 5040-3 class B B Reactive and apparent power acc.to EN 6053-3 class Measuring input Type of connection direct transformer.../5 A Voltage Un phase/phase V 400 400 phase/n V 30 30 Operating range voltage phase/phase V 3... 40 3... 40 phase/n V 4... 6 4... 6 Current Iref A 5 - Current In A - 5 Current Imin A 0.5 0.05 Operating range current (Ist... Imax) direct connection A 0.05... 0 - transformer connection A - 0.003... 6 Transformer current primary current of the transformer A - 5...000 smallest input step adjus. in 5 A steps A - 5 3

Technical data Data in compliance with EN 5040-, EN 5040-3, EN 6053-3 and EN 6053-3 ECSPM -ECSPM4 ECSPM06 -ECSPM ECSPM3 direct connection 0 A CT connect. till.000/5 A Measuring input Frequency Hz 50 50 Input waveform - sinusoidal sinusoidal Starting current for energy (Ist) ma 5 3 Pulse output SO acc.to EN 6053-3 (only for ECSPM-ECSPM4-ECSPM3-) pulse output pulse output for energy export - yes yes pulse output for energy import - yes yes Terminal output for direct connection 0 A Imp/ adjustable (max. 000) - depending on the transf. factor, adjus. Imp/ - adjustable (depends on CT) Pulse duration ms 30 ± ms 30 ± ms Required voltage min. (max.) VAC (DC) 5... 30 ±5% (5... 300) 5... 30 ±5% (5... 300) Permissible current pulse ON (max. 30 V AC/DC) ma 0 0 Permissible current Imp. OFF (leak. cur. max. 30VAC/DC) µa Safety acc. to EN 5040- Indoor meter - yes yes Degree of pollution - Operational voltage V 300 300 AC voltage test (EN 5040-3,.) kv 4 4 Impulse voltage test./50 µs-kv 6 6 Protection class (EN 5040) class II II Housing material flame resistance UL 4 class V0 V0 Adaptor for Communication (only for ECSPM3-) Plug-and-play technology - LAN (TCP/IP) interface Ethernet 0.3 - /0 Mbps /0 Mbps Modbus RTU, Ascii interface RS-45-3 wires - up to.00 bps up to.00 bps M-Bus interface wires - up to.600 bps up to.600 bps EIB-KNX interface EIB-standard - up to.600 bps up to.600 bps SD-Card Datalogger - to Gigabytes to Gigabytes Connection terminals Type cage main current paths screw head Z +/- POZIDRIV PZ PZ Type cage pulse output blade for slotted screw mm 0. x 3.5 0. x 3.5 Terminal capacity main current paths solid wire min. (max.) mm.5 (35).5 (6) stranded wire with sleeve min. (max.) mm.5 (35).5 (6) Terminal capacity pulse outlet solid wire min. (max.) mm 0.4 (.5) 0.4 (.5) stranded wire with sleeve min. (max.) mm 0.4 (.5) 0.4 (.5) Environmental conditions Mechanical environment - M M Electromagnetic environment - E E Operating temperature C -... +55 -... +55 Limit temperature of transportation and storage C -5... +0-5... +0 Relative humidity (not condensation) % 0 0 Vibrations 50 Hz sinusoidal vibration amplitude mm ±0.05 ±0.05 Degree protection housing when mounted in front (term.) - (*) For the installation in a cabinet at least with IP5 protection. IP5(*)/IP0 IP5(*)/IP0 Selection and ordering data digital display sim for all three phases: I-U - PF -Hz - P -Q-S active energy export/import -4modules DIN Version without pulse output ECSPM ECSPM06 Version with pulse output ECSPM4 ECSPM Version with pulse output set up for communication ECSPM3 direct connection0.5-5 (0) A digital display sim for all three phases: I -U-PF-Hz-P-Q-Sactive energy export/import with connection by CT.../5 A, up to.000/5 A - 0.05-5 (6) A direct connection0.5-5 (0) A - tariff - with connection by CT.../5 A, up to.000/5 A - 0.05-5 (6) A-tariff- direct connection0.5-5 (0) A - tariff - - set up for communication with connection by CT.../5 A, up to.000/5 A - 0.05-5 (6) A-tariff--set up for communication Optional - additional communication modules - module DIN 4