POWER FACTOR CORRECTION MRM Power factor regulators.

Similar documents
PFC POWER FACTOR CONTROLLERS POWER NEEDS CONTROL

FCR 06, FCR 12. Power factor correction controller. User and service manual

Power factor correction and harmonic filtering. Automatic power factor regulators R.1

Mounting Instructions / Manual MV1171

Reactive Power Control Relay RM 2106 / 2112 Operating Instructions. FRAKO Kondensatoren- und Anlagenbau

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

Computer-14d - xx - 144a

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Power factor correction and harmonic filtering. Automatic power factor regulators

Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features

LV Compensation & Filtering Products

ALPTEC POWER FACTOR CONTROLLER

Varlogic NR6, NR12. Power factor controller. User manual

Monitoring Electric Network Via Internet

DEIF A/S. Insulation monitor. Type SIM-Q

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

ULTRA RAPID POWER QUALITY ANALYZER

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

NETWORK ANALYZERS Analyzers

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

CAVA Series USER S MANUAL

Commissioning Instructions Rev. 03

2) APRV detects and records low frequency events (voltage drop, over-voltages, wave distortion) with a sampling frequency of 6400 Hz.

PLA 33. Power line analyzer. User and service manual. version 2.4

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

AC GHZ INTELLIGENT BROADBAND AMPLIFIER

Power IT LV Active Filters PQFA - PQFL - PQFT

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Moving Test - MT3000

Automatic capacitor banks with detuned filters

AC GHZ INTELLIGENT BROADBAND AMPLIFIER

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

N100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.

Protection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Automatic capacitor banks with detuned filters

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

Power Factor Control Relay

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

ACE3 INTELLIGENT BROADBAND AMPLIFIER

TCM-2 Thyristor Control Module DATA SHEET

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

NSL-10 STANDARD LIFE MODULAR CAPACITORS

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS

Reactors for filtering

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

ENERGY SAVING WITH OPTIMIZATION OF VOLTAGE AND CURRENT QUALITY

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

Power Factor Controller BR 5306 / 5312

AC3200 INTELLIGENT BROADBAND AMPLIFIER

DIGITAL SWITCH MODE POWER SUPPLIES MAIN APPLICATIONS GENERAL INTRODUCTION TO QP23 SERIES

The Power Factor Controller BR 6000

T 1000 PLUS Secondary Injection Relay Test Set

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

SIEMOS PQ The Multi-Functional Power Quality Analyzer for Low and Medium-Voltage Networks

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

PQM3000R Class A network analyzer according to EN for power quality monitoring

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

AC3000 INTELLIGENT BROADBAND AMPLIFIER

Power Meter Series PM3200 Functions and characteristics

ESTAmat MH Mounting Instructions MV1151

SUPPLY NETWORK ANALYZER CVM-96 SERIES

ATS-01 Ver1.2 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

REV-201М OPERATING MANUAL MULTIFUNCTIONAL TWO-CHANNEL TIME DELAY RELAY. «NOVATEK-ELECTRO» Ltd Intelligent industrial electronics

Energy Management Modular Smart Power Transducer Type SPT-90

Film Capacitors Power Factor Correction

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

EM-72 Electricity Meters for Current Transformers

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Reactive Energy Management

Energy Management Modular Power Analyzers Type WM2-96

Network Analyzer for Low-, Medium- and High-Voltage Networks

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

AC GHZ DISTRIBUTION AND TRUNK AMPLIFIER

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A)

TRIOL KN24+ VOLTAGE COMPENSATORS

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Installation and Operating Instructions. Power Factor Controllers RVT

ADJUSTABLE SPEED DRIVES FS1

Thyristorised Automatic Power Factor

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation

a * example of application MeaSUreMent and ViSUalization of power network parameters Ethernet TCP IP RS-485 USB HOST /SD CARD

DATA SHEET. Paralleling relays, HAS-111DG ANSI code 25

Capacitor Switching Contactors

VOLTAGE OPTIMIZATION FOR INDUSTRY, TRADE, BUSINESS AND LOCAL NETWORKS

TCS2P125. Automatic Transfer Switch Control Unit for 1 Phase System Operation Manual

TC LV-Series Temperature Controllers V1.01

With Audible Detect Signal

DATA SHEET POWER CAPACITOR

DATA SHEET Selectable AC transducer TAS-311DG

Transcription:

POWER FACTOR CORRECTION MRM - 12 factor regulators www.twelvee.com.pl

Introduction Rational reactive power economy in an enterprise requires maintaining cosφ at the level specified in the energy solicitation contract. It results in minimisation of uncompensated reactive power costs. The MRM - 12 power factor regulator manufactured by Twelve Electric is a tool helpful in maintaining the correct power factor in three phase LV and MV networks. Construction The MRM - 12 series of regulators is a family of modern, professional, digital devices for regulation of power factor, the cosφ. The microprocessor used allows intelligent control of reactive power regulation process and ensures high precision and sensitivity. Depending on the version, the regulator can control capacitor banks with low number of regulation stages (typical for small and medium businesses) or complex multi stage power factor correction systems used in big industrial enterprises. It can be used also for regulation in networks burdened with capacitive reactive power, where control of a bank built from PFC reactors is required. The regulator is reliable and easy to install and operate. It is enclosed in a standard size casing flush mounted on a door or an internal panel. a factory preset time blockade of reconnection of a recently disconnected capacitor. It prevents switching a capacitor on before its complete discharge (assuming that the discharge circuit is operating properly). The blockade is disabled in the version for controlling thyristor switches. The blockade is disabled in the version for controlling thyristor switches. The regulator also allows setting of the level of uncompensated reactive power to desensitise the regulator to low magnitude reactive power intake changes that do not worsen the tgφ, but if included into the power factor correction process, they would increase the number of switchings and speed up the wear contactors and capacitors. In some cases, too high sensitiveness of a regulator to minor, but frequent alterations causes all of the capacitors to be discharging at the same time and, as a consequence, worsens power factor correction effectiveness. Another important feature of the MRM - 12 regulator is the possibility of using one of seven predefined operation modes. It facilitates power factor correction optimised for different load specifics and stepping of power of capacitors making the bank. Operation principles The regulator cyclically, precisely measures the reactive power load in a network and analyses its characteristics. The measuring is carried out in a simplified Aron circuit basing on measurement of current in one phase, e.g. L1, and voltage in two remaining phases L2 and L3 (see fig. 1 3). The measuring data is analysed by the microprocessor calculating actual reactive power intake and deciding on switching of consecutive stages of the capacitor bank in accordance with user defined settings. The measuring circuit is highly sensitive, so the regulator works properly with CT currents from the order of 40 ma, allowing decent compensation with very low loads or an incorrectly sized current transformer. Regulation process can be adjusted to the characteristics and alteration dynamics of reactive power intake. This is thanks to the choice of three different measuring characteristics of the regulator, which increase its versatility and effectiveness. Data processing algorithms and measurement methods the regulator uses ensure correct operation with notable level of higher harmonic distortion in voltage and current (THDU 8 % or THDI 10 %). To reduce the number of switching processes that accompany frequent high magnitude power fluctuations, the regulation proceeds with a preset response time. The MRM - 12 regulator allows presetting of three independent response speeds, separately for switching the capacitors on and off, and for additional disconnection in order to minimise the time of overcompensation when the characteristic of the load changes into capacitive. Wide range of response time presets allows using the regulator for power factor correction in systems with various dynamics of reactive power alterations, especially for rapidly changing loads with short reactive power intakes (e.g. 200ms), where fast electronic capacitor switches, e.g. the BŁT 4, or special circuits for fast discharge of type DNE capacitors are in operation. Each MRM - 12 regulator has 2 factor regulators MRM - 12

Types of regulators The MRM - 12 power factor regulator is manufactured in a number of versions to meet different Customers needs and expectations. Each version can have 4, 6, 9, 12 or 15 switching outputs. A standard regulator operates at 400 V. For individual orders we also make other nominal voltages: 100 V, 230 V, 500 V, and 660 V. Versions of regulators The MRM - 12c/2xI 1 regulator is destined for power factor correction in systems with known reserve (when one of the transformers is the main power supply, while the other one is the reserve switched on in case of the main transformer fault see fig.2). The dual current input regulator conducts power factor correction on the main transformer and automatically switches the control over in case of connection and loading of the reserve transformer. The MRM - 12c/2xI 2 regulator finds its use in systems with hidden reserve (when two transformers work simultaneously see fig.3). In case of voltage decay on one of the transformers, an automatic changeover system burdens the other transformer with the whole load. After that the regulator automatically becomes controlled by the signal from the operating transformer s supply section. These features give solid economical effects as application of these regulators allows power factor correction with a single capacitor bank (MRM - 12c/2xI 1) or with banks without hidden reserve, that is matching the load of a particular section (MRM - 12c/2xI 2). Usage advantages basic: MRM - 12cs digital cosφ indicator, current percent value indicator, manual operation mode, automatic blockade of undischarged capacitor reconnection, three response times programmable in wide range of presets, seven operation algorithms suiting different series of capacitors, fault indicator, active stages indicator. with time clock control: MRM - 12c additional feature of time control. At a chosen time the regulator stops controlling the cosφ and disconnects the capacitors or switches on a predefined one. It also returns to automatic operation at a user set time. This feature lets maintain natural cosine when necessary and allows power factor correction on slight power flows, e.g. in the night hours, when production lines are off, on external lighting or idle running transformers. with dual current input: MRM - 12c/2xI 1 or MRM - 12c/2xI 2 standardly equipped with a controlling time clock, destined for working with two current transformers installed in two different sections of the supply. These regulators can be used in dual power supply systems or systems with reserve (dual), so in every place where there are two transformers working with an automatic transfer switch. Using the regulators with dual current inputs allows effective power factor correction not only during normal operation, but also when one of the transformers is disconnected. A PFC system controlled by an MRM - 12 regulator effectively compensates reactive power to the level required by an energy supplier. Correct choice of individual stages and the total power of a bank, and adequate setting of the regulator ensure cosφ at the level of 0.98 without significant network overcompensation states. Thanks to that it is possible to reduce, or even completely eliminate the cost of reactive power consumption, if it is calculated basing upon the difference between the actual tgφ and tgφ specified in the contract with the energy distributor. The MRM - 12 regulator allows fully automatic, supervision free power factor correction. It characterises with easy assembly and usage simplicity. It can be used as a replacement for older regulators without the need for modernisation of the capacitor bank. It is equipped with a set of indicators for monitoring of its condition. The built in display shows real time power factor (cosφ) to allow verification of the power factor correction effectiveness. Numerous programmable parameters ensure compatibility with different types of current transformers and steppings of capacitor banks, and give the possibility to optimise the PFC process in meet the specifics of a supply system and a load. Free Twelve Demo software helps to learn to program the regulator on a PC and to choose, and verify the settings to attain the best effectiveness of power factor correction with an actual load and a capacitor bank available. factor regulators MRM - 12 3

Technical parameters Standards: Voltage circuit: Nominal phase to phase voltage (specify when ordering) 100, 230, 400, 500 V Voltage tolerance 10 % +15 % Nominal frequency 50 Hz consumption 15 VA Current circuit: Nominal current 5 A Max. measured current 6 A Min. measured current 40 ma consumption 2,5 VA Output circuit: Number of stages (specify when ordering) 4 0, 6 0, 9 0, 12 0 or 15 0 Control voltage 230 V Output load capacity: 5 A at 250 V AC IP protection degree front: IP40; with special cover: IP54 terminals side: IP20 Operating temperature: 15 0 C (version with heating) +50 0 C Accuracy class: 1,5 Regulation range: non compensated reactive power %Q/n 0 150 % neutral zone Q/n 0,01 0,99 cosφ 0,3 ind. 0,7 poj. ind ON/OFF time, cap OFF time. 1 99 s step 1 s no. of control series 7 clock operation time without supply less than 6 months Indices/factors: power factor cosφ digital, four digits percentage of the current flowing through the current transformer digital, two digits current time hour and minute indication of steps switched on dioda LED Other: programming keypad connection 2,5 mm 2 wire multi contact connector weight <1,5 kg dimensions [mm] 144x144x85 mm (DIN 43700) mounting cutout dimensions [mm] 138x138 mm PN EN 5501; PN EN 61000 4 2; PN EN 61000 4 4; PN EN 61000 4 5; PN EN 61000 4 6; PN EN 61000 4 8; PN EN61000 4 11 Certificates: Attestation no. 0964/NBR/08 issued by the Electrotechnical Institute. 4 factor regulators MRM - 12

0,4kV Capacitor bank Contactors A 1 2 3 4 5 6 7 8 9 10 11 12 A REGULATOR MRM-12 L2 N L1 L2 L3 transformer L2 Fig.1. An MRM - 12 regulator connection schematic diagram. factor regulators MRM - 12 5

0,4kV Clutch Capacitor bank Contactors A 1 2 3 4 5 6 7 8 9 10 11 12 A REGULATOR MRM-12c/2xI-1 L2 S1 S2 N L1 L2 L3 N L1 L2 L3 transformer 1 L2 S1 S2 transformer 2 Fig.2. An MRM - 12c/2xI 1 regulator connection schematic diagram. 0,4kV Clutch Capacitor bank Capacitor bank Contactors Contactors A 1 2 3 4 5 6 7 8 9 10 11 12 A A 1 2 3 4 5 6 7 8 9 10 11 12 A REGULATOR MRM-12c/2xI-2 REGULATOR MRM-12c/2xI-2 L2 S1 S2 L2 S1 S2 N L1 L2 L3 N L1 L2 L3 transformer 1 transformer 2 L2 S1 S2 L2 S1 S2 Fig.3. An MRM - 12c/2xI 2 regulator connection schematic diagram. 6 factor regulators MRM - 12

TWELVE ELECTRIC S OTHER OFFERS Factor Correction K.99/3 LV power capacitors NETWORK QUALITY MONITORING AS 3plus Network Parameters Analyser with graphical display AS 3mini DIN mounted Network Parameters Analyser BK - T - 95 capacitor banks AS 3energia energy costs Analyser with elements of energy quality analysis AS 3diagnoza porte Network Parameter Analysers with set of measuring clamps AS Multi 2002 system software for data transfer, visualisation, reports and alarms DWD 12 filtering reactors IKT 12 individual compensator factor regulators MRM - 12 7

Twelve Electric Sp. z o.o. 04 987 Warszawa, ul. Wał Miedzeszyński 162 tel. +48 (22) 872 20 20, fax. +48 (22) 612 79 49 skype: t12e_1, t12e_2, t12e_3 e mail: twelvee@twelvee.com.pl www.twelvee.com.pl