PILOT Instructions 1. APPLICATIONS 2. OPERATING INDICATIONS 3. TERMINAL CONNECTIONS + - ON 3 OFF 10 OFF OFF 18/07/18

Similar documents
This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights

Motor 1- GENERAL DESCRIPTION

COD GB / 1.0 RBAND/UMS - RBAND/CSM

RADIOBAND 3G RB3 T868 RB3 R868 USER'S MANUAL

RADIOBAND V3 Programming & Installation Manual

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

WIRELESS PASSDOOR SWITCH ON 1034FLN 1034-OSE INSTALLATION / MAINTENANCE TWO THOUSAND SEVENTEEN

TCO6RX / TCO6TX. Transceiver system for mechanical safety and 8,2K resistive edges. Bidirectional communication

E L E V A T O R S ELEVATORS Impaginato_2009_UK.indd :34:14

ERONE CH RECEIVER

WIRELESS DIMMER FOR HEATING

Manufacturing Access Control since For more information, please visit or call toll free at

ELECTRONIC PANEL MC15

Pair of PMR446 Two-Way Personal Radios Model: TP391

HL 670 Data / Impulse Transmitter set User Manual. Version 07/2010

HL 675 Data / Impulse Transmitter set User Manual

VELA-RX MOTORE 220V 500W

PowerMonitor III. Digital Power and SWR meter for HF bands

MICRO-CONTROLLER X (48mm 48mm)

Radio to radio repeater. airrepeater INSTRUCTIONS MANUAL M A

RI-R11 series RI-R11D series

Operating Instructions

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs

Connect + compatible

T.CO.O - R.CO.O Double

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

KUBE Electronics AG. KUBE TR156 Universal PIR Circuit IC. For PIR Motion and Presence Detectors. Applications. Features

Wireless multizone receiver RDE-MZ6

Technical data. General specifications. Indicators/operating means. 95 Hz Multiplex operation 95 Hz / n, n = number of sensors, n 5

Manual GBR. Traffic detector VEK MNE 1 / VEK MNE2

WIRELESS MODBUS GATEWAY WGW410

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

WIRELESS Energy Monitor - Smart Meter

INSTRUCTIONS MANUAL DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS HRI-R40W

Instruction. Actuator ICAD 600 / ICAD 900 / ICAD 1200 ICAD 600 ICAD 900 ICAD 1200 ICAD 600 ICAD 900. ICAD 1200 Fig. 2. Fig. 4

ET RXTX-RC Weatherproof Repeater Version 2011/010. Specifications. Encryption: Rolling Code. Frequency: MHz

INSTALLATION MANUAL FOR RADIO CONTROL SESAM 6099 TRANSMITTER

CAME QP- V4.4 SPECIFICATION STANDARDS CABLE PLAN CABLE TYPES Z SERIES AUDIOCODE CONTROL SET FOR DOUBLE LEAF GATES

TO.GO 2VA TO.GO 4VA TO.GO 2AS TO.GO 2A TO.GO 2AK TO.GO 4AK TO.GO 2QV TO.GO 4QV TO.GO 4ASE PROGRAMMING GUIDE

True RMS Digital Multimeter Model:

VIPER Remote Control Systems

Analogowy przetwornik wzmacniający dedykowany dla czujników tensometrycznych RQA INSTALLATION MANUAL. Rev. 0.2

Intelligent Compact Controller

MATRIX INDUCTIVE LOOP CONTROL BOX

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on supply lines for medical locations ISOLTESTER-DIG-RZ/RS/PLUS

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

ORANGERX DSMX/DSM2/DEVO 2.4GHZ SWITCHABLE TRANSMITTER MODULE (FUTABA COMPATIBLE) USER MANUAL

Installation and operating instructions manual

Strain Gauge Measuring Amplifier BA 662

FMR MHz Receiver with Two Relay Outputs

TYXIA 253. Installation and use. France:

WHEN A PLC IS TOO MUCH, AND SPACE FOR

V~ DIMMER WITH BUILT-IN RADIO RECEIVER AND DALI OUTPUT FOR CONTROL BALLASTS AND LAMPS. Push-button input for manual controls.

Safety Technique. SAFEMASTER Emergency Stop Module LG 5925

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

Since 1987 Developed, Created and Made in Spain NDV5/ND5V VIDEO & DATA TRANSMITTER/RECEIVER

Model: VR-1A INSTALLATION AND OPERATING INSTRUCTIONS

Astra-R Kit Wireless Alarm System Operation Manual

MANUAL TLS IDENTIFICATION DATA OF THE MANUFACTURER KOLVER S.r.l. VIA M. CORNER, 19/ THIENE (VI) ITALIA

Istructions. Central control board for electromechanical gearmotors HERCULES 24V

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

K125M GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN

Quik Bridge Loop Receiver Installation Instructions

SRX882

Analog Servo Drive 25A20DD

SABRETrap Control. Description

MINI-SA2. User Manual. Technical Characteristics. Mounting. Version 1.1 MINI-SA2

Product and Applications Description

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

DP2500 DP0100 DP0250 Differential Pressure Transmitter

User Manual of MOBILUS C-SWP external module.

9RCT4334 Four Button. 2 3/4 X 1 3/8 X 9/16 (70mm x 35mm x 14mm) 2 3/4 x 2 1/8 x 1 (70mm x 55mm x 25mm)

Simplified Operations for TM-3100 Series Digital Tachometer

BEA s digital inductive single loop solution

FINE INSTRUMENTS CORPORATION

BeeLine TX User s Guide V1.1c 4/25/2005

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

MODEL ITMA DC - INTELLIGENT THERMOCOUPLE MODULE WITH ANALOG OUTPUT

SKJ. J1939 CANBus Output Signal. Linear Position to 400 inches (10 m) Compact Design Simple To Install User Adjustable Measuring Cable Orientation

27 HP V I GB I GB FADINI. Dis. N meccanica

EN TECHNICAL MANUAL. Technical manual for 7 MAXI SBC colour monitor Art. 6801W(/BM) Passion.Technology.Design.

USERS GUIDE MATRIX P/N SINGLE DIGITAL INDUCTIVE LOOP SENSOR

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

Instructions for programming and use Starline Roldeck - floorpanel control RD-2001

CAT-260 Repeater Controller Computer Automation Technology, Inc

Ness MCR Multi-Channel Radio Receiver

UR3 Coin Validator rel. 1.3 UR3 MDB-Executive Coin Validator rel. 1.2 UR3 T Coin Validator rel User and Maintenance Manual

BRAVO. SmartRadio Telemetry Module

Solid-State Digital Counter H7AN

Device manual Multifunction display and evaluation system FX 360. Mode/Enter

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Room Temperature Controllers. for heating and cooling systems

WARRANTY. Long Range Systems, LLC, 20 Canal St, Suite 4N, Franklin, NH 03235

Technical Equipment Specification

Transcription:

EN Instructions 8/07/8. APPLICATIS Control Unit specially designed for roller shutters whose tubular motors have integrated mechanical limit switches. Both radio receiver for emitter operations and Wirelessband receiver for safety edges are built in. Maximum power of the motor: 00 W.. OPERATING INDICATIS Operations are carried out by Push buttons (UP//DOWN) or with emitters. If an order is given during opening, the door will. (OPEN//DOWN). If an order is giving during closing, the door will invert. (-OPEN). On closing, the PHOTOCELL CLOSE activation will invert the manoeuvre. WITH OPTI - On opening, the PHOTOCELL OPEN activation stop the manoeuvre. WITH OPTI On opening, the PHOTOCELL OPEN activation stop and inverts the manoeuvre one second. On closing, the PHOTOCELL OPEN activation will invert the manoeuvre.. TERMINAL CNECTIS Wirelessband TX Programming Transmitters or digital time programming POWER SUPPLY MOPHASE MOTOR 6 7 LAMP 8 9 ACCESSORIES POWER SUPPLY 0 9 0 UP/DOWN/ COVER MEMBRANE CNECTOR 0V M COMÚN MOTOR CTACT CTACT V - V Button PHOTOCELL TEST (MUTE) CLOSE SAFETY PUSH BUTTS 6 7 7 8 M TEST LY PHOTOCELL CLOSE TEST PHOTO. 0v N.C. N.C N.O OPEN SAFETY RESITIVE 8K SAFETY OPTICAL SAFETY MECHANICAL N.C. N.C. 0 RESISTIVE 8K 8K Ohm N.O N.C 8K Ohm 0 OPTICAL SAFETY VCC 9 0 GND GND / 0V Signal OUTPUT SIGNAL GREEN WHITE BROWN - 6

8/07/8. TIME REGULATIS WITH POTENTIOMETERS AUTOMATIC CLOSING TIME (GREEN) - Minimum - sec Maximum - 90 secs 7 WORKING TIME (RED) - Alternative for digital programming Minimum - sec Maximum - 60 secs. OPTI SELECTOR AUTOMATIC CLOSING DISABLE WHEN OPENING SAFETY INPUT PERFORMANCE (-) DEAD MAN PHOTOCELL TEST Enabled. (see point ) Disabled. Alternative start button and emitters are disabled when opening. Door stops when alternative start button or emitter is activated. 8k safety edge Input, inverts the manoeuvre on closing. When opening it stops and inverts one second. Stop the manoeuvre on opening when connecting a Photocell. Enabled. Disabled. Enabled. Disabled. 6 7 8 9 0 RADIO PROGRAM. DIGITAL TIME PROGRAM. CLASS WB WB FRECUENCY WIRED SAFETY EDGE Emitter radio pairing activated from control unit and from paired emitter (points 9./9.) Emitter radio pairing only from control unit (point 9.) Self-learnig programmation. (see point 8.) Analog programmation times with potentiometers. Conforms normative UNE-EN 89-. Disabled. (by default) 869,8 Mhz. (same as transmitter) 868,9 Mhz. (same as transmitter) Terminal optical safety edge. Terminal resistive or mechanical safety edge. (see option ) 6. PHOTOCELL TEST Checking status of PHOTOCELL OPEN & CLOSE before starting any operation. E.g.: We could have a photocell with test in CLOSE input and no photocell connected in OPEN input (with wire bridge on terminals - because is a N.C. contact). The current scenario will be set as default. TEST When DIP Switch actives the Photocell test function, if test is OK you'll hear one beep, if there's a fail you'll hear two beeps. In case of failure you can only close the door in dead man. WARNING! Visual check on the photocell before working is highly recommended. 7. DEAD MAN DEAD MAN DISABLED DEAD MAN CLOSING DEAD MAN OPEN & CLOSE - 6

8/07/8 8. MANEUVER SELF-LEARNING DIGITAL TIME PROGRAMMING ( button or Transmitter) 7 Adjusted Limit Switch.s.s DIGITAL TIMES ADJUSTED LIMIT SWITCH PUSH PUSH CLOSED DOOR DOOR OPENING DOOR CLOSING PUSH PROG TRANS/TIME CTROL PANEL OPENING CLOSING LED OPENED DOOR CLOSED DOOR BACK TO PROG TRANS/TIME ( A SENS* OPENED DOOR DETECTED A SENS* CLOSED DOOR DETECTED LED SAVE & QUIT LED ES The automatically closing waiting time is regulated by the green potentiometer. * A SENS Automatic limit switches detection ( 9. EMITTER PAIRING OPTIS 9. EMITTER PAIRING FROM CTROL UNIT.s 0s PUSH TRANS/TIME CTROL PANEL X LED PUSH BUTT X X S SAVE & EXIT 9. EMITTER PAIRING VIA RADIO A.s A A B 0s MUST HAVE A RECORDED IN A CTOL UNIT PUSH A SPECIAL FUNCTI X PUSH BUTT X X S SAVE & EXIT 9. TIME AND EMITTER FULL MEMORY RESET.s s 0s X BIP KEEP IT ED # S X S SAVE & EXIT - 6

8/07/8 0. WIRELESSBAND.0 0. REGULAR CNECTIS 0. OTHER CNECTIS Safety Edge Common Inhibitor Resistive 8K or Mechanical (Choose in WB.0 transmitter options 0. (Option )) Safety Edge Common Inhibitor External signal Resistive 8K or Mechanical (Choose in WB.0 transmitter options 0. (Option )) To avoid safety edge activation before end of closing. E.g.: Uneven floor scenario. 0. OPTI SELECTOR SAFETY EDGE TYPE FREQUENCY Resistive Mechanical 869,8 Mhz (same as receiver) 868,9 Mhz (same as receiver). WIRELESSBAND.F. REGULAR FOR OSE CNECTIS. OTHER CNECTIS 6 6 INPUT COM Inhibitor COM INPUT VCC Optical Low Power OUTPUT SIGNAL GREEN VDC BROWN GND / 0V WHITE INPUT COM Inhibitor COM INPUT VCC Optical Low Power OUTPUT SIGNAL GREEN VDC BROWN GND / 0V WHITE Configuration for Optical External signal (see point.) X Sleeping mode active in receiver () To avoid safety edge activation before end of closing. E.g.: Uneven floor scenario. - 6

8/07/8. OPTI SELECTOR SAFETY EDGE TYPE (INPUT ) SAFETY EDGE TYPE (INPUT ) FREQUENCY Resistive (8kΩ) Mechanical (0Ω) Resistive configuration Optical configuration 869,8 Mhz (same as receiver) 868,9 Mhz (same as receiver) (see point.) -X X IN - Resistive transmitter (default) (see point.) IN - Optical transmitter Input Resistive Input Mechanical Input Optical Not used. Input LOW POWER OPTICAL SAFETY EDGE or RESISTIVE PROGRAMMING PROCESS 6 IN VCC COM - - OPTICAL X RESISTIVE/ MECHANICAL X.s OPTICAL RESISTIVE / MECHANICAL. CNECT OPTICAL EDGE TO. CNECT BATTERIES. STATUS INDICATI. BUTT FOR CHANGE STATUS. STATUS CHANGE 6. LED 7. SAVE & EXIT. WIRELESSBAND PROGRAMMING PROCESS TX WIRELESSBAND CODE MEMORITZATI.s Default optical configuration. You have seconds after battery connection to make the change of safety edge status. If you want to change again the status, please remove and connect batteries again. 0s W.BAND CTROL PANEL X RECEIVER WIRELESSBAND X X S SAVE & QUIT TX WIRELESSBAND MEMORY RESET.s s 0s X W.BAND CTROL PANEL KEEP IT ED # S W. BAND CTROL PANEL X S SAVE & QUIT MEMORY FULL INDICATOR Several beeps for 0 seconds when trying to memorize a new transmitter. The system can store 7 transmitters per channel. LOW BATTERY INDICATOR beeps each time a message is received from a programmed transmitter. Both, warning LED and buzzer are activated simultaneously. - 6

8/07/8. HOUSING OPTIS - : Plastic box. - -K: Plastic box and push buttons (frontal membrane). - -K L: Plastic box and push buttons (frontal membrane) and courtesy light. TECHNICAL SPECIFICATIS Power 0V AC /- 0% Max Drive Power. KW Power Suply for accessories V DC / V AC Flashing light output and garage Relay contact Max. Garage light time min. Working Time From sec to 60 sec Automatic closing time From sec to 90 sec Max. nº of emitters codes Nº of WirerlessBand transmitters WB.0 / 7 WB. / 7 WB.F Frecuency MHz/868MHz Sensitivity Better than -0dBm Distance 00m Temperature -0 to 8º WARNING!! - Equipment installation and start-up, can only be executed by qualified personal. CE DECLARATI OF CFORMITY Aplicaciones electrónicas y de Radiofrecuencia S.L Pol. Sot dels Pradals C/ Sot dels pradals, 0800 Vic (Barcelona) B6807 DECLARES, under her own responsibility that product It is designed and manufactured in accordance with the directives LV 006/9/CE of Low Voltage, EMC 00/08/CE of Electromagnetic Compatibility, 006//CE Machines directive and is designed to control doors in accordance with standard EN- (00) and complies with the requirements of the R&TTE 99/0/CE European parliament directive of March 9th 999. This directive was transposed to the Spanish legislation by means of Real Decree 890/000 in November 0th of 000, directive 999//CE spectrum radio electric protection, electromagnetic compatibility directive 00/08/CE. For more information visit the website www.aerf.eu 6-6