CMOS Instrumentation Amplifier with Offset Cancellation Circuitry for Biomedical Application

Similar documents
The Design of Tag-ItTM Compatible MHz Passive RFID Transponder IC Employing TSMC 0.18µm Process

Design and Simulation of Low Voltage Operational Amplifier

Analog CMOS Interface Circuits for UMSI Chip of Environmental Monitoring Microsystem

Design of High Gain Low Voltage CMOS Comparator

Nizamuddin M., International Journal of Advance Research, Ideas and Innovations in Technology.

Rail-To-Rail Output Op-Amp Design with Negative Miller Capacitance Compensation

Design of High Gain Two stage Op-Amp using 90nm Technology

A 24 V Chopper Offset-Stabilized Operational Amplifier with Symmetrical RC Notch Filters having sub-10 µv offset and over-120db CMRR

A Novel Low Noise High Gain CMOS Instrumentation Amplifier for Biomedical Applications

Topology Selection: Input

A Compact Folded-cascode Operational Amplifier with Class-AB Output Stage

Chapter 5. Operational Amplifiers and Source Followers. 5.1 Operational Amplifier

Lecture 300 Low Voltage Op Amps (3/28/10) Page 300-1

Solid State Devices & Circuits. 18. Advanced Techniques

A 16Ω Audio Amplifier with 93.8 mw Peak loadpower and 1.43 quiscent power consumption

A Compact 2.4V Power-efficient Rail-to-rail Operational Amplifier. Strong inversion operation stops a proposed compact 3V power-efficient

ANALYSIS AND DESIGN OF HIGH CMRR INSTRUMENTATION AMPLIFIER FOR ECG SIGNAL ACQUISITION SYSTEM USING 180nm CMOS TECHNOLOGY

Chapter 13: Introduction to Switched- Capacitor Circuits

Operational Amplifier with Two-Stage Gain-Boost

A new class AB folded-cascode operational amplifier

CHAPTER 3. Instrumentation Amplifier (IA) Background. 3.1 Introduction. 3.2 Instrumentation Amplifier Architecture and Configurations

Low Power Op-Amp Based on Weak Inversion with Miller-Cascoded Frequency Compensation

Pankaj Naik Electronic and Instrumentation Deptt. SGSITS, Indore, India. Priyanka Sharma Electronic and. SGSITS, Indore, India

d. Can you find intrinsic gain more easily by examining the equation for current? Explain.

A New Design Technique of CMOS Current Feed Back Operational Amplifier (CFOA)

DESIGN OF A NOVEL CURRENT MIRROR BASED DIFFERENTIAL AMPLIFIER DESIGN WITH LATCH NETWORK. Thota Keerthi* 1, Ch. Anil Kumar 2

An Improved Bandgap Reference (BGR) Circuit with Constant Voltage and Current Outputs

ECEN 474/704 Lab 6: Differential Pairs

Performance Analysis of Low Power, High Gain Operational Amplifier Using CMOS VLSI Design

Design and Performance Analysis of Low Power RF Operational Amplifier using CMOS and BiCMOS Technology

An Analog Phase-Locked Loop

Op-Amp Design Project EE 5333 Analog Integrated Circuits Prof. Ramesh Harjani Department of ECE University of Minnesota, Twin Cities Report prepared

Comparison between Analog and Digital Current To PWM Converter for Optical Readout Systems

Design for MOSIS Education Program

Design of Miller Compensated Two-Stage Operational Amplifier for Data Converter Applications

DESIGNING OF CURRENT MODE INSTRUMENTATION AMPLIFIER FOR BIO-SIGNAL USING 180NM CMOS TECHNOLOGY

Class-AB Low-Voltage CMOS Unity-Gain Buffers

ANALYSIS AND DESIGN OF ANALOG INTEGRATED CIRCUITS

Ultra Low Static Power OTA with Slew Rate Enhancement

A High-Driving Class-AB Buffer Amplifier with a New Pseudo Source Follower

Radivoje Đurić, 2015, Analogna Integrisana Kola 1

Design Analysis and Performance Comparison of Low Power High Gain 2nd Stage Differential Amplifier Along with 1st Stage

A PSEUDO-CLASS-AB TELESCOPIC-CASCODE OPERATIONAL AMPLIFIER

Design and implementation of two stage operational amplifier

Design and Simulation of Low Dropout Regulator

A Linear CMOS Low Drop-Out Voltage Regulator in a 0.6µm CMOS Technology

Sensors & Transducers Published by IFSA Publishing, S. L.,

Rail to rail CMOS complementary input stage with only one active differential pair at a time

Design of Low Voltage Low Power CMOS OP-AMP

Comparative Analysis of Compensation Techniques for improving PSRR of an OPAMP

Design of a low voltage,low drop-out (LDO) voltage cmos regulator

DESIGN AND PERFORMANCE VERIFICATION OF CURRENT CONVEYOR BASED PIPELINE A/D CONVERTER USING 180 NM TECHNOLOGY

Design and Layout of Two Stage High Bandwidth Operational Amplifier

ECEN 474/704 Lab 5: Frequency Response of Inverting Amplifiers

EE Analog and Non-linear Integrated Circuit Design

ECE 415/515 ANALOG INTEGRATED CIRCUIT DESIGN

TWO AND ONE STAGES OTA

IN RECENT years, low-dropout linear regulators (LDOs) are

ANALYSIS AND DESIGN OF ANALOG INTEGRATED CIRCUITS

ISSN:

F9 Differential and Multistage Amplifiers

Advanced Operational Amplifiers

Design of High-Speed Op-Amps for Signal Processing

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 02, 2016 ISSN (online):

Study of Differential Amplifier using CMOS

Radivoje Đurić, 2015, Analogna Integrisana Kola 1

UMAINE ECE Morse Code ROM and Transmitter at ISM Band Frequency

Design of a Capacitor-less Low Dropout Voltage Regulator

DUAL ULTRA MICROPOWER RAIL-TO-RAIL CMOS OPERATIONAL AMPLIFIER

A CMOS Low-Voltage, High-Gain Op-Amp

Microelectronic Circuits II. Ch 10 : Operational-Amplifier Circuits

Full Paper ACEEE Int. J. on Control System and Instrumentation, Vol. 4, No. 2, June 2013

What is the typical voltage gain of the basic two stage CMOS opamp we studied? (i) 20dB (ii) 40dB (iii) 80dB (iv) 100dB

Research and Design of Envelope Tracking Amplifier for WLAN g

Design of a Sample and Hold Circuit using Rail to Rail Low Voltage Compact Operational Amplifier and bootstrap Switching

SOLIMAN A. MAHMOUD Department of Electrical Engineering, Faculty of Engineering, Cairo University, Fayoum, Egypt

CMOS Operational Amplifier

Design and Analysis of Low Power Two Stage CMOS Op- Amp with 50nm Technology

1.8 V Low Power CMOS Rail-to-Rail Input/Output Operational Amplifier AD8515

Amplifiers Frequency Response Examples

IOWA STATE UNIVERSITY. EE501 Project. Fully Differential Multi-Stage Op-Amp Design. Ryan Boesch 11/12/2008

DESIGN OF A FULLY DIFFERENTIAL HIGH-SPEED HIGH-PRECISION AMPLIFIER

Basic Circuits. Current Mirror, Gain stage, Source Follower, Cascode, Differential Pair,

Analog Electronics. Lecture Pearson Education. Upper Saddle River, NJ, All rights reserved.

Experiment #7 MOSFET Dynamic Circuits II

Design technique of broadband CMOS LNA for DC 11 GHz SDR

ECE4902 C Lab 5 MOSFET Common Source Amplifier with Active Load Bandwidth of MOSFET Common Source Amplifier: Resistive Load / Active Load

You will be asked to make the following statement and provide your signature on the top of your solutions.

Atypical op amp consists of a differential input stage,

[Kumar, 2(9): September, 2013] ISSN: Impact Factor: 1.852

Design and Analysis of High Gain Differential Amplifier Using Various Topologies

Design and Analysis of Current-to-Voltage and Voltage - to-current Converters using 0.35µm technology

A Unity Gain Fully-Differential 10bit and 40MSps Sample-And-Hold Amplifier in 0.18μm CMOS

High Voltage and Temperature Auto Zero Op-Amp Cell Features Applications Process Technology Introduction Parameter Unit Rating

DAT175: Topics in Electronic System Design

A New Low Voltage Low Power Fully Differential Current Buffer and Its Application as a Voltage Amplifier

Rail-to-Rail, 200kHz Op Amp with Shutdown in a Tiny, 6-Bump WLP

Operational Amplifiers

CMOS fast-settling time low pass filter associated with voltage reference and current limiter for low dropout regulator

An 8-Channel General-Purpose Analog Front- End for Biopotential Signal Measurement

Transcription:

CMOS Instrumentation Amplifier with Offset Cancellation Circuitry for Biomedical Application Author Mohd-Yasin, Faisal, Yap, M., I Reaz, M. Published 2006 Conference Title 5th WSEAS Int. Conference on SYSTEM SCIENCE and SIMULATION in ENGINEERING (ICOSSE '06) Copyright Statement 2006 WSEAS. The attached file is reproduced here in accordance with the copyright policy of the publisher. Please refer to the conference's website for access to the definitive, published version. Downloaded from http://hdl.handle.net/10072/46722 Link to published version http://worldses.org/reports/2006/tenerife/index.html Griffith Research Online https://research-repository.griffith.edu.au

Proceedings of the 5th WSEAS Int. Conf. on System Science and Simulation in Engineering, Tenerife, Canary Islands, Spain, December 16-18, 2006 168 CMOS Instrumentation Amplifier with Offset Cancellation Circuitry for Biomedical Application F. MOHD-YASIN, M.T. YAP Faculty of Engineering Multimedia University) 63100 Cyberjaya, Selangor MALAYSIA M. B. I. REAZ Dept. of Electrical and Computer Engineering International Islamic University Malaysia 53100 Kuala Lumpur MALAYSIA Abstract: - This paper presents the design and development of a CMOS Instrumentation Amplifier for biomedical application. This design manages to achieve 101dB gain, PSRR > 102dB and 91dB CMRR. The final circuit consumes total of 0.318µWatts power at 1.8V supply voltage and possesses die size of 9.6nm 2 area. It also has a full CMOS implementation of offset cancellation circuitry, among the first of its kind. Comparison with more complex work shows improved or comparable results. Key-Words: - instrumentation amplifier, biomedical application, CMOS 1 Introduction A biomedical instrumentation system usually consists of transducer, amplifier, and associated signal conditioning circuitry. The most sensitive element in the system are the input signals, like blood pressure, body temperature, pulse or heart beat rate. These signals are acquired and transformed into voltage signal with the amplitude of several milli-volt. Since the voltage signal is very low and very susceptible to noise, the amplifier playing an important role to amplify signals into significant value for signal processing. Instrumentation amplifier is very crucial in biomedical instrumentation system due to its high input impedance, and high common-mode rejection ratio to reject the unwanted signals [1]-[2]. An instrumentation amplifier is normally employed in portable and battery powered device. The development of CMOS instrumentation amplifiers is gaining popularity nowadays because of its low power requirement. CMOS transistor uses little power and does not produce as much heat as the traditional Biopolar Junction Transistor (BJT). Since the size of channel length of CMOS transistor is shrinking very significantly, it allows a high density of logic functions on a chip. This paper illustrates the functionality of different modules of the instrumentation amplifier, followed by the integration of the blocks to make a full instrumentation amplifier. The design techniques applied in order to optimize the performance of the circuits are also highlighted. Comparison with a recent published work [1] is also made. 2 Circuit Building Blocks A. Operational Amplifier The two-stage rail-to-rail input/output operational amplifier is used as the main amplifier stage. The CMOS op amp is designed based on the TSMC Mixed Signal 0.18µm-process technology. The power supply is set to 1.8V for low powered biomedical application devices. The op amp is design to process 0.9V common mode input voltage and able to amplified several milivolts of differential mode input voltage. Figure 1 shows the simplified schematic diagram of the CMOS op amp. The first stage is the folded-cascode op amp where the channel length of both input differential pair transistor M1n, M2n, M1p and M2p is set to minimum length which is 0.18µm. Input transconductance has been increased to increase the gain efficiency of the first stage and to have a lower thermal noise. This also helps minimizing the capacitance at the internal nodes as well. The channel length of transistors M3, M4 and M9, M10 are sized larger than minimum length, which is 0.3µm and 0.62µm respectively, to increase the drain to source impedance. Since the transconductance of these transistors have no effect on the DC small signal gain, thus the transconductance efficiency is not a design concern. To achieve a greater gain from the push-pull amplifier in the second gain stage, the gate length of transistors M11 and M12 are sized 0.3µm and 0.62µm respectively. This increases the miller effect at the end stage, thus the transistor size of the compensation capacitors N12 and P12 are set to

Proceedings of the 5th WSEAS Int. Conf. on System Science and Simulation in Engineering, Tenerife, Canary Islands, Spain, December 16-18, 2006 169 minimum value to reduce the miller effect. generator. A static CMOS gate is a combination of the pull-up network (PUN) and the pull-down network (PDN). The PUN and PDN networks are connected in a mutually excusive fashion such that at every point in time, the gate output is connected to either positive power supply (V DD ) or negative power supply (V SS ). The PDN is constructed using NMOS devices, where an NMOS switch is on when the gate signal is high and off when the gate signal is low. On the other hand, PMOS transistors are used in PUN, where the PMOS transistor act as an inverse switch that is turn on when gate signal is low and turn off when the gate signal is high. Figure 1 Simplified schematic of CMOS op-amp B. Biasing Circuit The bias circuit of the operational amplifier consists of two basic current sources. The current sources are designed to supply I bias, 20μA for the two differential input pair. For the NMOS current source, transistors M1, M2 and M3 are used as voltage divider to control the gate-source voltage of transistor M7 and M11. The size of M7 and M11 are made identical to M3 thus the output current I bias mirrors exactly the drain current through M2 and M3. In the PMOS current source, the size of transistors M8 and M12 are set equal to M4 to get output current I bias. D. Instrumentation Amplifier Figure 3 shows the structure of the three op amp instrumentation amplifier. At first, the gain stage is design without the consideration of the input offset voltage cancellation circuitry. C. Clock Generator Figure 2 shows the circuitry that generates the non-overlapping clocks ph1 and ph2. The clock signals are used to activate the NMOS switches in the input offset cancellation circuitry. The clock signals ph1b and ph2b have an opposite phase to the ph1 and ph2 respectively. Ph1b and ph2b are the control signals of the dummy transistors, which connect both side of the NMOS switch [2]. Figure 2 Clock generator The static CMOS design is used to implement the NOT, NAND and NOR gates for the clock Figure 3 Instrumentation Amplifier The two non-inverting amplifiers Op2 and Op3 are function as input buffer stage to increase the input impedance. Op amp 1 is a differential amplifier function as an amplifying stage. By observation, the negative feedback of the upper-left op amp causes the voltage at point 1 (top of R3) to be equal to V1. Likewise, the voltage at point 2 (bottom of R3) is held to a value equal to V2. This establishes a voltage drop across R3 equal to the voltage difference between V1 and V2. That voltage drop causes a current through R3, and since the feedback loops of the two input op-amps draw no current, that same amount of current through R3 must be going through the two resistors R4 above and below it. The regular differential amplifier on the right-hand side of the circuit then takes this voltage drop between points 3 and 4, and amplifies it by a gain of R2/R1.

Proceedings of the 5th WSEAS Int. Conf. on System Science and Simulation in Engineering, Tenerife, Canary Islands, Spain, December 16-18, 2006 170 E. Complete Circuit The complete circuitry of the CMOS instrumentation amplifier with input offset cancellation is shown in Figure 4. The two noninverting amplifiers Op2 and Op3 function as an input buffer stage to increase the input impedance. Differential amplifier Op1 function as an amplifying stage. The negative feedback of Op2 causes the voltage at point 1 to be equal to Vn1. Likewise, the voltage at point 2 equal to Vp1. This establishes a voltage drop across R1 equal to the voltage difference between Vn1 and Vp1, which causes a current through R1. Since the feedback loops of the two input op-amps draw no current, thus this current flow through the two resistors R2. Differential amplifier Op1 amplifies this voltage drop by a gain of R4/R3. The non-overlapping clock generator is used to control all the NMOS switches [3]. The capacitors Cos1, Cos2, and Cos3 that are connected between the input terminals, store the input offset voltage corresponding to Vos1, Vos2 and Vos3 for each op amp. When ph1 goes high, switches S1, S2, S4, S5, S7, and S8 are closed, the IA is in the offset storage mode, and the offset voltages of each op amp are stored across each capacitor. Eventually ph1 goes low and ph2 goes high, switches S3, S6, and S9 are closed, and the circuit is in the offset cancellation mode. Figure 4 Complete Circuit with Offset Cancellation Circuitry The input offset voltages are cancelled by the precharged voltages stored in the capacitors Cos1, Cos2, and Cos3. It is connected with opposite polarity to the positive input terminal of each op amp. Each time a switch is turned off, the charges in its conducting channel are released and removed through the NMOS source and drain terminals. Thus, two dummy transistors are placed on the both sides of each switch transistor, to absorb the channel charges split equally between source and drain of NMOS switch. The two dummy transistors are controlled by ph1b and ph2b clock signals, which have the opposite phases to the switch transistor. The Cgs or Cgd of a switch transistor is approximated to the total parallel capacitance of ( Cgs + Cgd ) of a half-sized dummy transistor with source and drain short [4]-[7]. Capacitors Cos1, Cos2, and Cos3 are chosen to be 110fF. The (W/L) of NMOS switches is set to 2, while the minimum (W/L) of 1 are used for the dummy transistors to reduce total error voltage. 3 Results and Discussion The CMOS instrumentation amplifier is designed using Mentor Graphics design tools based on TSMC 0.18um technology. The complete schematic of the instrumentation amplifier consists of 3 CMOS op amp, clock generator and input offset cancellation circuitries. The clock generator is represented by an instance to output the clock signals ph1, ph1b, ph2 and ph2b to the input offset cancellation circuitry. For the purpose of testing, the resistor R1 and R3 is chosen to be 50kΩ, R2 and R4 is set 25kΩ to create voltage gain of 10. Resistors R1, R2, R3 and R4 are intended to be off chip component, which were not included in the circuit layout to reduce the size of overall layout. The Capacitors Cos1, Cos2, and Cos3 have value of 110fF to store the offset voltage of each op amp. The offset voltage is set 1mV and connected in opposite polarity to each positive terminal of op amp. Table 1 shows the summary of the results and comparison with [1]. Description Table 1 Comparison with results from [1] Circuit designed by Chih-Jen Yen [1] Circuitry design in this project Technology 0.5µm 0.18µm Power supply 2.5V -7.5V 1.8V Gain average 19.99 db 19.6 db Gain Bandwidth 20kHz 100MHz CMRR (at DC) >110 db 92 db PSRR (at DC) > 102dB > 102 db Input-reffered noise 175nV/ Hz 2.28e-5 V/ Hz Current consumption 61µA - 125µA 413µA Die area 0.2mm 2 13.34nm 2

Proceedings of the 5th WSEAS Int. Conf. on System Science and Simulation in Engineering, Tenerife, Canary Islands, Spain, December 16-18, 2006 171 This instrumentation amplifier has managed to get a comparable gain, CMRR and PSRR. This design also consumes power in micro-watts range which is suitable for low power biomedical instrumentation application. Since the minimum channel length of the transistor has reduced to 0.18µm, the switching speed of the MOS transistor had been greatly increased. This design has significant increase in the gain bandwidth to 100MHz. This means the CMOS instrumentation amplifier in this project able to function at higher frequency compare to the circuit designed by [1]. The chip area has been greatly reduced, which led to smaller die size. It must be noted that the instrumentation amplifier designed by Chih-Jen Yen et al [1] has a lower input offset noise and lower current consumption. However, these advantages were achieved by using more complex CMOS and BJT wide swing design with start-up circuit to supply the bias current. The price is higher fabrication cost, compared to our full CMOS approach, which uses standard 0.18u process. The layout of the project is shown in Figure 5 below. 4 Conclusion The design and development of a CMOS Instrumentation Amplifier for biomedical application is presented. It is found that the design has lower power supply, wider frequency response and smaller size, compared to the previous works. This design managed to achieve a comparable gain, CMRR and PSRR. The previous design has more complex and higher fabrication cost, since it used CMOS and BJT wide swing design, while this design uses full CMOS 0.18u standard process [8]. References: [1] J.Y.Chih, W.Y.Chung, and Mely.C.C, Micro-Power Low-Offset Instrumentation Amplifier IC Design For Biomedical System Applications, IEEE Transactions On Circuits And Systems I: Regular Papers, Vol. 51, No. 4, April 2004. [2] Q. Huang and M. Oberle, A 0.5-mW passive telemetry IC for biomedical between applications, IEEE J. Solid-State Circuits, vol. 33, pp. 937 946, July 1998. [3] R. C. Yen and P. R. Gray, A MOS switchedcapacitor instrumentation amplifier, IEEE J. Solid- State Circuits, vol. SC-17, pp. 1008 1013, Dec. 1982. [4] Denis Daly, Design of a low-power CMOS operational amplifier, October 22, 2003. [5] Paul R. Gray, Robert G. Meyer, Stephen H. Lweis, Analysis And Design of Analog Integrated Circuits, John Wiley & Sons INC, 2001. [6] Philip E. Allen and Douglas R. Holberg, CMOS Analog Circuit Design, Oxford University Press, March 2002. [7] Donald A. Neamen, Electronic Circuit Analysis and Design, McGraw Hill Higher Education, January 2001. [8] M.K. Khaw,, F. Mohd-Yasin, M.B. Reaz, The Design of Tag-ItTM Compatible 13.56 MHz Passive RFID Transponder IC Employing TSMC 0.18µm Process, accepted for presentation in WSEAS CSEC, Dallas, Texas, Nov 1-3, 2006. Figure 5 Full layout