Light sensor. 24V DC Power Input Common Ground Connection RS485 Data + Open Collector Output 2. Analogue Current Output Analogue Voltage Output

Similar documents
Ocean Controls KT-5221 Modbus IO Module

The first RADIO Communication Module designed for the weighing industry

SRC-110 Series Zone Controllers with Modbus RTU

Modbus communication module for TCX2: AEX-MOD

CoolEx User Manual 2008 XDIMAX LTD. Revision 1.0

SV613 USB Interface Wireless Module SV613

Series F4P Communications Guide

AVL-10000T AUDIO VIDEO LINK TRANSMITTER TECHNICAL MANUAL

SRC-110 Series Zone Controllers. BACnet MS/TP. Product sheet CT2.143 SRC-110-BAC

Data Acquisition Modules/ Distributed IO Modules

Channels that are not occupied by temperature sensors, can take over alternative functions:

Configuration of CPE 310-S and CPE 311-S transmitters by keypad

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

LP PHOT LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S. Light

LVTX-10 Series Ultrasonic Sensor Installation and Operation Guide

LVCSi Continuous Vertical Level Sensor with Integrated Display

ioselect Z-NET Z-4RTD 4 Channel RTD Input Module

ENERGY-0-RS. Energy Meter. User manual

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Embedded Radio Data Transceiver SV611

B850 Boiler House Energy Monitor

LC-10 Chipless TagReader v 2.0 August 2006

Characteristics and functioning

DRF4432D20 20dBm ISM RF Transceiver Module V1.21

LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S

Micro Motion Model 1700 Transmitters with Analog Outputs 1700***A. Configuration and Use Manual Supplement. Configuration Operation Maintenance

BATCHMATE 1500 Batch Control Computer Technical Bulletin

R5 RIC Quickstart R5 RIC. R5 RIC Quickstart CONTENTS. Saab TransponderTech AB. Appendices. Project designation. Document title

USB Port Medium Power Wireless Module SV653

Microprocessor Based Multistage Temperature Controller & Two Channel 365 Day Time Switch. Made in Australia 100% Australian Owned Company

Catalog

M7 Series Modems for SCADA Applications

FlatPack Ultrasonic Sensors

AcuMesh Wireless RS485 Network. User's Manual SOLUTION

Modbus Integration Integration for Modbus Functionality for VT8300 Series

FOD Transmitter User s Guide

ELT Sensor Data Sheet for S-300-3V

VFS11 Parameter List for up to CPU version 105

Installation and Operating Instructions

Catalog

RM-2000-RTDW Remote Monitor User s Guide

CT435. PC Board Mount Temperature Controller

SMARTALPHA RF TRANSCEIVER

MK110-8D.4R. Digital I/O-Module 12 channel 8 DI, 4 DO. User guide

PROCESS & TEMPERATURE CONTROLLERS

Advanced Analog Technology, Inc. October 2009 AAT1301 PACKAGE PACKING TEMP RANGE MARKING. T: Tape and Reel. 20 C to +85 C.

MU110-16R(K) Digital output module 16 channel. User guide

Technical Specifications Power Supply: V o V (50 60 Hz)

Lecture #3 RS232 & 485 protocols

Catalog

Characteristics and functioning

Series 2000 Reader System. Reader S251B RI-STU-251B. Reference Guide. April 2000 SCBU035

WIRELESS MODBUS GATEWAY WGW410

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

MPS PROFIBUS-DP INTERFACE

Installation Instructions and Reference Handbook. Installation instructions

Peer Master Example. In This Chapter...

Connection and Operation (Built-In Controller Package)

To define the procedure for operating the FGRIO-S, FGR2-IOS and I2-IOS radios in Modbus:

DEIF A/S. Description of options. Option H1, CAN open communication Basic Gen-set Controller. Description of option. Functional description

X3M. Multi-Axis Absolute MEMS Inclinometer Page 1 of 13. Description. Software. Mechanical Drawing. Features

Catalogue

USB-B1 User Manual V1.1

Configuration of C310 multifunction transmitters by keypad

SOLO Temperature Controllers 1/4 DIN

Relay Driver Overview and Applications

Heliotrack Programmable Wind Alarm Switch V1.0 Developed in partnership with Inspeed.com, LLC

A Super trainer with advanced hardware and software features only found in very expensive equipment.

Endurance R/C Wi-Fi Servo Controller 2 Instructions

SV-MESH Mesh network series Catalogue

TNM96-ETL Energy Meter & Electrical Powermeter

RF1212 RF1212 Ultra-low Power ISM Transceiver Module V2.0

FOD Transmitter User s Guide

Lifetime Power Energy Harvesting Development Kit for Wireless Sensors User s Manual - featuring PIC MCU with extreme Low Power (XLP) Technology

SDIC XX 5075 SD5075. Two Wires Communication Digital Temperature Sensor. Features. Description. Applications. Ordering Information

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

FCR 06, FCR 12. Power factor correction controller. User and service manual

B850 Boiler House Energy Monitor

Brushed DC Motor Control. Module with CAN (MDL-BDC24)

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

RF4432PRO wireless transceiver module

Single Channel Loop Detector

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many

The wireless alternative to expensive cabling...

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

Specification GRUNER YSP 227C

TABLE OF CONTENTS... 2 PHYSICAL DESCRIPTION Baseboard description...7. Display board description...8 CONNECTING... 9 POWER FEATURES...

Temperature Controller model MFC-301/T-Dry. Version for Dry Transformers and Motors. Technical Manual. Licht

HD 48V01T... HD 4977T...

USER MANUAL SATEL i-link I/O-converter Version 1.6

RF4432 wireless transceiver module

KNX manual 1-channel flush-mounted switch actuator SU 1

Analog Module D1-15P User Manual

CD4 Series with linear image sensor and electronic shutter provides accurate measurement.

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

PL420 PROGRAMMABLE LOGIC CONTROLLER

Ramp/Soak Temperature Controller REX-P250

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

Transcription:

Light sensor PCB/enclosure temperature sensor Interface to PLCs using the MODBUS protocol Communicate via 2-wire S-485 Interface to instrumentation using to 2, 4 to 2, or to 1 V signals Generate alarms based on values of light or temperature Monitor alarms using MODBUS protocol or onboard open collector outputs Introduction: The KTA-275 is a light and PCB temperature sensor. Values of light and/or temperature can be monitored via the analogue retransmission channels in to 2, 4 to 2, or to1 V formats. Additional control is provided by two on-board open collector outputs, which can be configured to trigger at pre-defined values of light or temperature. In addition, all readings and configurations can be monitored and changed via the MODBUS protocol over two-wire S-485. Connections: Connection Vs GND Description 24V DC Power Input Common Ground Connection D- S485 Data - D+ S485 Data + OC1 Open Collector Output 1 OC2 Open Collector Output 2 Iout Analogue Current Output Vout Analogue Voltage Output Modbus: Modbus is a Master-Slave protocol. The PLC or PC is usually the master with a number of slaves (in this case KTA-275 cards). Each slave is given a unique address from 1 to 243. The master outputs a command to the slave and the slave processes the command and transmits a response back to the master. In the KTA-275 all data is stored in 16 bit holding registers. All configuration registers are backed by EEPOM, conserving their values between power downs. 1 of 7

eg # ead/w EEPOM rite Backed? Description 1 Light Value (Lux)1 (max: 16384)4 2 PCB Temperature Value (Degrees Celsius x 1)2 (max: 2555)45 3 Open Collector 1 Status (1 = On, = Off) 4 Open Collector 2 Status (1 = On, = Off) 1 OC1 Sensor ( = light, 1 = temperature) 11 OC1 Configure: Bit : Enable OC1 lower threshold ( = off, 1 = On) Bit 1: Enable OC1 upper threshold ( = off, 1 = On) Bit 2: OC1 Trigger Mode ( = within thresholds; 1 = outside thresholds) 12 OC1 Lower Threshold6 13 OC1 Upper Threshold6 14 OC1 Hysteresis Band 15 OC2 Sensor ( = light, 1 = temperature) 16 OC2 Configure: Bit : Enable OC2lower threshold ( = off, 1 = On) Bit 1: Enable OC2upper threshold ( = off, 1 = On) Bit 2: OC2 Trigger Mode ( = within thresholds ; 1 = outside thresholds) 17 OC2 Lower Threshold6 18 OC2 Upper Threshold6 19 OC2 Hysteresis Band 2 Iout Sensor ( = light, 1 = temperature) 21 Iout Configure ( = 4-2, 1 = -2 ) 22 Iout Lower Bound 23 Iout Upper Bound 24 Vout Sensor ( = light, 1 = temperature) 25 Vout Lower Bound 26 Vout Upper Bound 3 Modbus Address (1 to 243; default: 1) 31 Baud ate: 1: 24 baud 2: 48 baud 3: 96 baud 4: 192 baud 5: 384 baud 6: 576 baud 7: 1152 baud Default 3: 96 baud 32 Parity: 2 of 7

1: Odd 2: Even 3: ne Default3: ne IMPOTANT NOTES: 1: Lux is the SI unit of illuminance; defined as 1 lumen per square meter. The lumen is a (human eye weighted) measure of light power. Several Australian Standards dictate minimum levels of light. Some main ones are summarised here: Location/Activity imum Illuminance (Lux) Office 32 Factory (Large Scale Assembly) 16 Factory (Fine Work electronics assembly, etc) 6 Factory (Precision assembly/machining) 12 2: The PCB temperature value is scaled by a factor of 1 to provide increased resolution. Take care when reading the temperature value or setting configurations. 3: All values not specified will automatically use the default value. 4: The sensor value ranges must be considered when setting user definable registers. Do not exceed these limits. 5: The temperature sensor is that of the PCB. Due to heat generated by the internal electronics, this value will typically be higher than ambient. This value can differ from ambient by as much as 1C; depending on the power supply voltage. 6: Only one threshold should be enabled at any one moment. Communications: The KTA-275 is equipped with a S-485 transceiver. Communications settings of the unit are configured using the on-board 8-way DIP switch, or by manipulating the relevant Modbus holding registers. SW1-2 control the Modbus address, SW3-5 control the baud rate, SW6-7 control the parity, and SW8 resets all comms settings to default. After changing any communications configuration settings (either by writing to the holding registers or changing the switches) the power must be cycled to adopt the new values. SW1 SW2 Address Set using Modbus (holding register 3) 1 2 3 3 of 7

SW3 SW4 SW5 Baud Set using Modbus (holding register 31) 24 48 96 192 384 576 1152 SW6 SW7 Parity Set using Modbus (holding register 32) Odd Even ne SW8 eset action eset all settings to default (address = 1, baud = 96, parity = none) If the switches are set to, the communications settings are set via the Modbus holding registers; these default to Address = 1, Baud ate = 96 and Parity = ne. The reset switch overwrites all other settings. 4 of 7

Configuration Software: Ocean Controls supply a software configuration package called KTA-275 Configurator which is a simple to use program. The configuration software allows the user to monitor the light and temperature values, and the statuses of the open collector outputs, as well as setting all user configurable values. Communications Communication settings can be set by pressing the Comms menu item. The following values are required: Com port (The PC com port connected to the KTA-275) Modbus address Baud rate Parity If these settings are correct, the unit and PC will start communicating. Sent and received data can be observed in the transmit and receive text boxes at the bottom of the screen. The area marked communications allows the comms settings of the KTA-275 to be manipulated (this is not to be confused with the comms settings of the Configuration Software previously described). These values read and write the relevant Modbus registers. eadings The top of the screen displays the instantaneous values of light and temperature numerically and 5 of 7

graphically - in units of Lux and degrees Celsius respectively. Text boxes on either side of the graphic control the resolution of the bar. Set each value# to provide a suitable range for displaying the light and temperature. The minimum and maximum values of these sensors is given in the specifications at the end of this document. Take heed of these values when setting any user configurable parameters. Open Collector Outputs The open collector outputs can be configured in a multitude of ways to suit your particular application. Begin by choosing the sensor; each output can be triggered by either light or temperature. A second control allows the user to choose the behaviour of the output; inside thresholds will turn on the output if the reading (light or temperature) falls below the upper threshold O above the lower threshold. Conversely, outside thresholds will turn on the output if the reading is below the lower threshold O above the upper threshold see note 6 above. The thresholds themselves can be defined using the text boxes marked upper threshold and lower threshold. The accompanying tick box will enable each of these controls. A third text box marked hysteresis allows the user to define a guard band to prevent multiple triggering of the output when the reading is varying close to the threshold(s). The tick boxes marked Force OC1 and Force OC2 can be used to override these settings and set the output manually. Ensure that no thresholds are enabled when using this functionality. All settings must be written to the TU before they become functional. Configurations can also be read using the corresponding button. The state of the output is indicated by dynamic text below the mode selector controls ( in black or in red). Example The user requires notification when the light level in their factory falls below 5 lux, and if the PCB/enclosure temperature is above 27 C. The KTA-275 would be configured as follows: Open Collector 1 Mode: Light Trigger: Outside thresholds Lower Threshold: 5 lux + enabled Upper threshold: disabled Hysteresis: ~5 Open Collector 2 Mode: Temperature Trigger: Within Thresholds Lower threshold: 27+ enabled Hysteresis: ~1 Analogue e-transmission The KTA-275 can also output the value of light or PCB temperature as voltage or current signal. The lower and upper bound for transmission can be set using the corresponding text box. The output will scale linearly between these two values. The current output has an option of to 2 or 4 to 2 range. The voltage will vary between to 1 V. Each selection must be written to the TU before it becomes functional. #: These thresholds do not affect the KTA-275 in any way; they are only used to manipulate the graphic. 6 of 7

Specifications Power Supply Typ Supply Voltage 12 24 4 V 1 8 C 28 1152 Baud Current Draw Operating Temperature -2 S-485 Transceiver Typ Driver Current Symbol ate 24 96 Data Bits 8 Parity ne Stop bit 1 Odd, Even Open Collector Outputs Parameter Current Sink 3 Voltage 5 V Voltage Output Voltage 1 V 18 Current Draw Current Output Parameter Current 2 Loop esistance (Vsupply x 49) - 36 Ohm Sensors Light eading 16384 Lux Temperature eading -2 125 Celsius 7 of 7