Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in Single or Dual output type Onsite selectable output type (DC current / DC voltage) Accuracy class 0.2 (IEC/ EN 60 688) Seven Segment LCD Display Rs485(Modbus) Communication
Application Theta 20A/20V The is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal Output signal generated is proportional to the root mean square value of the input Current or Voltage. Product Features Measuring Input AC Voltage/ Current input signal, sine wave or distorted wave form. Analog Output (Single or dual) Accuracy Programmable Input / Output Isolated analog output which can be set onsite to either voltage or current output. Output signal accuracy class 0.2 as per International Standard IEC/EN 60 688. The Transducer can be programmed onsite using front key & display or through programming port (COM) or through RS 485. LED Indication Display Module RS485 Communication (Optional) LED indication for power on and output type. (Current output : Red LED, Voltage output : Green LED) Symbols and their meanings Dimensions 2 Input AC Voltage / AC Current Start value of input Elbow value of input End value of input Output DC Voltage / DC Current Start value of output DC Voltage / DC Current Elbow value of output DC Voltage / DC Current End value of output DC Voltage / DC Current RN FN Rated value of output burden Nominal Frequency Reference conditions for Accuracy Pre-conditioning Ambient temperature 23 C 30 min +/- acc. C to IEC / EN 60 688 Input Variable Input waveform Sinusoidal, Form Factor.07 Input signal frequency Auxiliary supply voltage Rated Voltage / Rated Current 50 or 60Hz At nominal range Output Load Rn = 7.5 V / ± % With DC current output signal Rn = / ma ± % With DC voltage output signal Miscellaneous Acc. to IEC / EN 60 688 Page of 5
Accuracy ( Acc. to IEC / EN 60688) Reference Value Basic Accuracy C= 2 or C= Output end Value (Voltage or Current) 0.2 * C Factor C (The highest value applies if calculated C is less than, then C= applies) Linear characteristics Installation Data Mechanical Housing Mounting position Weight Bent characteristics For < < - 2 C= or C= - For < < 2 Auxiliary Power Supply AC/DC Auxiliary Supply AC Auxiliary supply frequency range Auxiliary supply consumption 60V...300 VAC-DC 24V...60 VAC-DC Current Transducer Nominal input Current IN (AC RMS) (CT Secondary range) CT Primary range Nominal Frequency FN Nominal input Current burden Overload Capacity C= 2 or C= Lexan 940 (polycarbonate) Flammability Class V-0 acc. To UL 94, self extinguishing, non dripping, free of halogen Rail mounting / wall mounting Approx. 0.4kg 60V 300 VAC-DC ± 5% or 24... 60 VAC-DC ± 0% 40 to 65 Hz A IN 5 A A to 9999 A 45...66 Hz < 0.2 VA at IN < 8VA for Single output < 0VA for Dual output < 5 VA for Single output < 6 VA for Dual output.2 * IN continuously, 0* IN for 3 second, repeated 5 times at 5 minute intervals. 50* IN for second, repeated time at hour interval(max 250 A). No need of external potentiometer. User can set full scale output for desired input with the help of programmable CT secondary. Additional Error ± 0.2% /0 C Measuring Input Voltage Transducer (Beta 20A) Nominal input Voltage UN (AC RMS) (PT Secondary range) PT Primary range Nominal Frequency FN Nominal input Voltage burden Overload Capacity 57V UN 500 V 57V to 400 kv 45...66 Hz < 0.6 VA at UN. 2 * UN continuously, 2* UN for second, repeated 0 times at 0 minute intervals (Maximum 300V with power supply powered from measuring input). No need of external potentiometer. User can set full scale output for desired input with the help of programmable PT secondary. Measuring Output ( Single or Optional Dual) Output type Load independent DC output () Output burden with DC current output Signal Output burden with DC voltage output Signal Current limit under overload R=0 Voltage limit under R= Residual Ripple in Output signal Response Time Ambient tests EN 60 068-2-6 Acceleration Frequency range Number of cycles EN 60 068-2-7 Acceleration EN 60 068-2-/-2/-3 IEC 6000-4-2/-3/-4/-5/-6 EN 55 0 Load independent DC Voltage or DC Current (Onsite selectable through DIP switches & programming.) 0 20mA / 4 20mA OR 0 0V. 0 R 5V/ /(2 ma) R.25 * with current output 00 ma with voltage output <.25 * with voltage output 30 V with current output % pk-pk 400 msec Vibration ± 2 g 0...50...0Hz, rate of frequency sweep: octave/minute 0, in each of the three axes Shock 3 x 50g 3 shocks in each direction Cold, Dry, Damp heatw Electromagnetic compatibility. Page 2 of 5
Safety Protection Class II (Protection Isolated, EN 6 00) Protection IP 40, housing according to EN 60 529 IP 20,terminal according to EN 60 529 Pollution degree 2 Installation Category III Insulation Voltage min. ( EN 6 00-) 7700VDC, Input versus outer surface 5200VDC, Input versus all other circuits 5200VDC, Auxiliary supply versus outer surface and output 690VDC, Output versus output versus each other versus outer surface. Connection Terminal Connection Element Conventional Screw type terminal Permissible cross section of the connection lead with indirect wire pressure Electrical Connections Connection Measuring input Auxilliary Power supply Measuring output - Measuring output - 2 Input V / I ~ ~ Aux + - ~ ~ 5 6 7 8 Terminal details ~ ~ ~, + ~, - + - + - 5 6 7 8 2 3 4 As per IEC / EN 60688 standard. Output stability < 30min Environmental Nominal range of use 0 to 45 C Storage temperature -40 to 70 C Relative humidity of annual mean Altitude 75% 2000m max + - Output- 2 3 4 + - Output-2 (Optional) Output Characteristics 2 2 2 2 = Start value of input = Elbow value of input 2 = End value of input = Start value of output = Elbow value of output = End value of output Note: End value() of output cannot be changed onsite. Page 3 of 5
LED Indication ON LED Aux.supply healthy condition Green LED continuous ON O/P LED Output voltage selection Output Current selection Green LED continuous ON Red LED continuous ON O/P2 LED Output2 voltage selection Output2 Current selection Green LED continuous ON Red LED continuous ON of transducer can be done in three ways Via port (COM) ) Via Front LCD & two keys. 2) Via optional RS485(MODBUS) communication port. ( Device address, PT Ratio,CT Ratio,Password,communication parameter,output Type & simulation mode can be programmed). 3) Via port available at front of Transducers using optional PRKAB60 Adapter. The connections between PC PRKAB Tra on between the Transducers To Con gure the t Power supply Transducer DIP Switch Setting for OUTPUT Type of output (current or voltage signal) has to be set by DIP switch For programming of DIP switch the user 5 6 7 8 connector needs to open the transducer housing & set the DIP switch located on PCB to the desired output type Voltage or Current. Output range changing is not possible with DIP switch setting. Transducer Programing cable PRKAB 60 The four pole DIP switch is located on the PCB in the Transducer DIP Switch Setting ON 234 Type of Output Signal load-independent current Software CD ON 234 load-independent voltage
Ordering Information Standard Version Product Code TT20-00000 Product Type THETA 20A I THETA 20V V Input Range Prog. 5A -5A 74 Prog. 57 500V 57-500V 8E 60-300U H Power Supply 24-60U F Output O/P O 2 O/P 2O 2 Display Module With Display D Without Display WD Z RS485 Module With RS-485 485 R Without RS-485 Z Prog. Cable With PRKAB 60 PRK C Without PRKAB 60 Z Page 5 of 5