Theta 20A / 20V. Technical Data Sheet. Special Features

Similar documents
Theta Hz. Technical Data Sheet. Special Features

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

SINEAX U 553 Transducer for AC Voltage

SUBJECT TO CHANGE WITHOUT NOTICE

ZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer

SINEAX I 552 Transducer for AC current

EMBSIN 281 G Power factor transducer

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

SINEAX G 536 Phase Angle or Power Factor Transducer

RISH CON - Hz FREQUENCY TRANSDUCER

POWER \ PHASE ANGLE \ POWER FACTOR TRANSDUCER RISH

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

SINEAX TV809, 1 channel Programmable Isolating Amplifier

SINEAX G 537 Transducer for Phase Angle Difference

RISH Ducer E13 3 channel transducer for AC current and voltage

Technical Data Sheet. x1000. kwh R Y B

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Technical Datasheet. True RMS Digital Protection Relay. Voltage Protection Relay

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Relay. Technical Datasheet. True RMS Digital Protection Relay. Line Monitoring Relay

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Programmable AC Current Transducer MT418

Programmable AC Voltage Transducer MT416

AMIK 200 / 201 Technical Data Sheet

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

DATA SHEET Selectable AC transducer TAS-311DG

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

RS Pro ENGLISH. Datasheet

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

Digital Multifunction Instrument - Rish Master 3440

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

RS Pro ENGLISH. Datasheet

Technical Data Sheet AMIK 300 / 301

Jewell DPM EINE BEST IN CLASS

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

RISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters

Zelio Control Measurement Relays

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

JUMO dtrans T04 Four-wire Transmitter, settable via DIP switch/pc setup program

SINEAX B 811 Power Pack with additional Functions

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator

Data Sheet. RISH Master Record %THD

AMIK Three Phase Digital Panel Meters

08/07/2015

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Product Guide. Transducers

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

CP-T range Product group picture

Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features

Universal measuring transducer

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

08/07/2015

Totalizing Counters mini-i

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

CP-T range Benefits and advantages

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Technical Data Sheet

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

Energy Management Energy Analyzer Type EM210 MID

02/11/2015

Coupling Relays and Converters

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

22/10/2012

For Immediate Delivery call KMParts.com at (866)

Series P. Applications

Process displays For standard signals, temperature, resistance measurement

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

RISH Delta Energy / Demand (Multifunction instrument) Data Sheet

02/11/2015

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

02/11/2015

Measuring centers MC7x0 series Multifunction Meter MC740

02/11/2015

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

02/11/2015

Transcription:

Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in Single or Dual output type Onsite selectable output type (DC current / DC voltage) Accuracy class 0.2 (IEC/ EN 60 688) Seven Segment LCD Display Rs485(Modbus) Communication

Application Theta 20A/20V The is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal Output signal generated is proportional to the root mean square value of the input Current or Voltage. Product Features Measuring Input AC Voltage/ Current input signal, sine wave or distorted wave form. Analog Output (Single or dual) Accuracy Programmable Input / Output Isolated analog output which can be set onsite to either voltage or current output. Output signal accuracy class 0.2 as per International Standard IEC/EN 60 688. The Transducer can be programmed onsite using front key & display or through programming port (COM) or through RS 485. LED Indication Display Module RS485 Communication (Optional) LED indication for power on and output type. (Current output : Red LED, Voltage output : Green LED) Symbols and their meanings Dimensions 2 Input AC Voltage / AC Current Start value of input Elbow value of input End value of input Output DC Voltage / DC Current Start value of output DC Voltage / DC Current Elbow value of output DC Voltage / DC Current End value of output DC Voltage / DC Current RN FN Rated value of output burden Nominal Frequency Reference conditions for Accuracy Pre-conditioning Ambient temperature 23 C 30 min +/- acc. C to IEC / EN 60 688 Input Variable Input waveform Sinusoidal, Form Factor.07 Input signal frequency Auxiliary supply voltage Rated Voltage / Rated Current 50 or 60Hz At nominal range Output Load Rn = 7.5 V / ± % With DC current output signal Rn = / ma ± % With DC voltage output signal Miscellaneous Acc. to IEC / EN 60 688 Page of 5

Accuracy ( Acc. to IEC / EN 60688) Reference Value Basic Accuracy C= 2 or C= Output end Value (Voltage or Current) 0.2 * C Factor C (The highest value applies if calculated C is less than, then C= applies) Linear characteristics Installation Data Mechanical Housing Mounting position Weight Bent characteristics For < < - 2 C= or C= - For < < 2 Auxiliary Power Supply AC/DC Auxiliary Supply AC Auxiliary supply frequency range Auxiliary supply consumption 60V...300 VAC-DC 24V...60 VAC-DC Current Transducer Nominal input Current IN (AC RMS) (CT Secondary range) CT Primary range Nominal Frequency FN Nominal input Current burden Overload Capacity C= 2 or C= Lexan 940 (polycarbonate) Flammability Class V-0 acc. To UL 94, self extinguishing, non dripping, free of halogen Rail mounting / wall mounting Approx. 0.4kg 60V 300 VAC-DC ± 5% or 24... 60 VAC-DC ± 0% 40 to 65 Hz A IN 5 A A to 9999 A 45...66 Hz < 0.2 VA at IN < 8VA for Single output < 0VA for Dual output < 5 VA for Single output < 6 VA for Dual output.2 * IN continuously, 0* IN for 3 second, repeated 5 times at 5 minute intervals. 50* IN for second, repeated time at hour interval(max 250 A). No need of external potentiometer. User can set full scale output for desired input with the help of programmable CT secondary. Additional Error ± 0.2% /0 C Measuring Input Voltage Transducer (Beta 20A) Nominal input Voltage UN (AC RMS) (PT Secondary range) PT Primary range Nominal Frequency FN Nominal input Voltage burden Overload Capacity 57V UN 500 V 57V to 400 kv 45...66 Hz < 0.6 VA at UN. 2 * UN continuously, 2* UN for second, repeated 0 times at 0 minute intervals (Maximum 300V with power supply powered from measuring input). No need of external potentiometer. User can set full scale output for desired input with the help of programmable PT secondary. Measuring Output ( Single or Optional Dual) Output type Load independent DC output () Output burden with DC current output Signal Output burden with DC voltage output Signal Current limit under overload R=0 Voltage limit under R= Residual Ripple in Output signal Response Time Ambient tests EN 60 068-2-6 Acceleration Frequency range Number of cycles EN 60 068-2-7 Acceleration EN 60 068-2-/-2/-3 IEC 6000-4-2/-3/-4/-5/-6 EN 55 0 Load independent DC Voltage or DC Current (Onsite selectable through DIP switches & programming.) 0 20mA / 4 20mA OR 0 0V. 0 R 5V/ /(2 ma) R.25 * with current output 00 ma with voltage output <.25 * with voltage output 30 V with current output % pk-pk 400 msec Vibration ± 2 g 0...50...0Hz, rate of frequency sweep: octave/minute 0, in each of the three axes Shock 3 x 50g 3 shocks in each direction Cold, Dry, Damp heatw Electromagnetic compatibility. Page 2 of 5

Safety Protection Class II (Protection Isolated, EN 6 00) Protection IP 40, housing according to EN 60 529 IP 20,terminal according to EN 60 529 Pollution degree 2 Installation Category III Insulation Voltage min. ( EN 6 00-) 7700VDC, Input versus outer surface 5200VDC, Input versus all other circuits 5200VDC, Auxiliary supply versus outer surface and output 690VDC, Output versus output versus each other versus outer surface. Connection Terminal Connection Element Conventional Screw type terminal Permissible cross section of the connection lead with indirect wire pressure Electrical Connections Connection Measuring input Auxilliary Power supply Measuring output - Measuring output - 2 Input V / I ~ ~ Aux + - ~ ~ 5 6 7 8 Terminal details ~ ~ ~, + ~, - + - + - 5 6 7 8 2 3 4 As per IEC / EN 60688 standard. Output stability < 30min Environmental Nominal range of use 0 to 45 C Storage temperature -40 to 70 C Relative humidity of annual mean Altitude 75% 2000m max + - Output- 2 3 4 + - Output-2 (Optional) Output Characteristics 2 2 2 2 = Start value of input = Elbow value of input 2 = End value of input = Start value of output = Elbow value of output = End value of output Note: End value() of output cannot be changed onsite. Page 3 of 5

LED Indication ON LED Aux.supply healthy condition Green LED continuous ON O/P LED Output voltage selection Output Current selection Green LED continuous ON Red LED continuous ON O/P2 LED Output2 voltage selection Output2 Current selection Green LED continuous ON Red LED continuous ON of transducer can be done in three ways Via port (COM) ) Via Front LCD & two keys. 2) Via optional RS485(MODBUS) communication port. ( Device address, PT Ratio,CT Ratio,Password,communication parameter,output Type & simulation mode can be programmed). 3) Via port available at front of Transducers using optional PRKAB60 Adapter. The connections between PC PRKAB Tra on between the Transducers To Con gure the t Power supply Transducer DIP Switch Setting for OUTPUT Type of output (current or voltage signal) has to be set by DIP switch For programming of DIP switch the user 5 6 7 8 connector needs to open the transducer housing & set the DIP switch located on PCB to the desired output type Voltage or Current. Output range changing is not possible with DIP switch setting. Transducer Programing cable PRKAB 60 The four pole DIP switch is located on the PCB in the Transducer DIP Switch Setting ON 234 Type of Output Signal load-independent current Software CD ON 234 load-independent voltage

Ordering Information Standard Version Product Code TT20-00000 Product Type THETA 20A I THETA 20V V Input Range Prog. 5A -5A 74 Prog. 57 500V 57-500V 8E 60-300U H Power Supply 24-60U F Output O/P O 2 O/P 2O 2 Display Module With Display D Without Display WD Z RS485 Module With RS-485 485 R Without RS-485 Z Prog. Cable With PRKAB 60 PRK C Without PRKAB 60 Z Page 5 of 5