DET4 Series. 4-Terminal Earth/Ground Resistance and Soil Resistivity Testers. DET4 Series Earth/Ground Resistance & Soil Resistivity Testers

Similar documents
GROUND RESISTANCE TEST EQUIPMENT

MIT510, MIT520 and MIT1020

5-kV and 10-kV Insulation Resistance Testers. n CAT IV 600 V safety rating. n Line supply or battery operated

MIT400 CAT IV Industrial Insulation Testers

MIT400 CAT IV Industrial Insulation Testers

MFT1735 User guide addendum

VF3 AC Voltage detector. User Guide Guide de l utilisateur Bedienungsanleitung Guía del usuario

G SAFETY WARNINGS. LT300 High current loop tester. User guide

MIT400 CAT IV Industrial Insulation Testers

Fluke 1623 and GEO Earth Ground Testers. Technical Data. Stakeless testing

Insulation Testers and Earth Ground Testers

ODEN AT Primary Current Injection Test System

Fluke and

BMM80 Premium Insulation Multimeters

MIT515, MIT525, MIT1025

MIT400 CAT IV Industrial Insulation Testers

BM25 Automated 5-kV Insulation Tester

GROUND TESTERS GROUND RESISTANCE TEST TEST EQUIPMENT DET3 CONTRACTOR SERIES WHAT S IN THE DET3T NAME? DIGITAL EARTH TESTER 3 TERMINAL

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832)

MIT400/2 CAT IV Insulation testers

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

MIT510/2, MIT520/2 and MIT1020/2

n Single- and three-phase transformer n Lightweight, handheld n Battery powered, line rechargeable n Tests turns ratio, phase displacement,

MIT480/2 Insulation testers

ELECTRICAL TEST EQUIPMENT CATALOG

FRAX 101 Sweep Frequency Response Analyzer

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

Digital Ground Resistance Tester. Model 4610 & 4610 Kits

MIT400/2 CAT IV Insulation testers

FRAX Series Sweep Frequency Response Analyzers

TTR 100 Single-Phase Handheld TTR

GROUND TESTERS For all of your Ground Testing needs...

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

Stake-less earth / ground testing

Indeks: WMGBMRU30 Earth Resistance and Resistivity Meter

The future of installation testing is here. The 1650 Series Multifunction Testers

Attendee Announcements

UAT-600 Series. amprobe.com

User Manual 4 wire Earth Resistance Tester Model GRT300

MIT400 Series CAT IV Insulation Resistance and Continuity Testers

1650 Series Multifunction Installation Testers

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

MIT415 Insulation tester

Laboratory oil testers

INSTRUCTION MANUAL E1612 EARTH TESTER 1. INTRODUCTION

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

Instruction Manual for Digital Grounding Resistance Meter

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

GROUND RESISTANCE TESTERS

TORKEL 900-series Battery Load Unit

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:

PV210. Why buy the PV210?

Fluke Clamp Meters Solutions for every need

Quick Start Guide AT-6000 Advanced Wire Tracer Series

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

EARTH RESISTANCE TESTER

DET2/3. Advanced Earth (Ground) Tester. User Guide

Earth 2/3 MI 2126 Instruction Manual Version 1.0, Code No

BITE 3 Battery Impedance Test Equipment

Fluke T5 Electrical Testers. Fluke T and T5-600 Voltage, Continuity and Current Testers

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

Fluke 355 and 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents

8PK-ST1520 Digital Earth Resistance Tester

HT COMBI419. Innovative meter designed to perform all safety test

ELECTRICAL TESTING AND SAFETY

HT1000/2 Series Copper Wire Analyser

PV200. Why buy the PV200? The most compact I-V curve tracer around.

1587/1577 Insulation Multimeters

Safety Issues Caused by High Earth Resistance and Identifying Them Using Instruments

GFL-1000 User Manual Ground Fault Locator

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

MFT1800 series. Multifunction testers. User manual

1507/1503. Insulation Testers. Technical Data. Features and benefits:

Insulation resistance testing. A complete solution for every person.

AEMC Megohmmeters. AEMC Flexible Current Probe

Clamp-On Ground Resistance Tester Model 3705

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

TORKEL 900-series Battery Load Unit

Tested Tough. Trusted Safe.

MFT1800 Series. Multifunction testers. User Manual

USER'S MANUAL DMR-6700

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Multi-Function Installation Tester MEGGER CM500. User Guide MEGGER

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

MEGOHMMETER. User Manual

C.A 6117 C.A 6116N C.A 6113 Multi-function installation testers

cable and pipe locators RD Utility cable and pipe locator

Obsolete Document. Dynatel

MEGGER CM300 MK II, CM400 MK II & CM500

Exposure Level Tester ELT-400

Measure voltage without test leads. Product Highlights

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

N. TEST TEST DESCRIPTION

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

Transcription:

4-Terminal Earth/Ground Resistance and Soil Resistivity Testers DET4 Series 2, 3 and 4 point testing Stakeless (clamp-on) testing capability ART (Attached Rod Technique) capability Multiple, user selectable test frequencies Resistance measurement range to 200,000 Ω IP54 rated Warning indicators prevent test failure Simple one button operation Included leads, stakes, calibration certificate and rugged carry case DESCRIPTION Megger s popular 4-terminal ground testing instrument family includes four basic models with different kit variants for each that include select accessories for greater testing flexibility. The four basic units are: Model Description DET4TD2 Dry-cell battery powered basic 4-terminal tester DET4TR2 Rechargeable battery powered basic 4-terminal tester DET4TC2 Dry-cell battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability DET4TCR2 Rechargeable battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability The top-end models (DET4TC2 and DET4TCR2) include a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection (as explained further in this document). They also provide stakeless testing capability. This method allows the operator to use the instrument like a clamp-on ground tester in applications where that method is viable, while also being able to operate as a fall of potential tester if required. The basic kit includes the test leads, stakes, batteries and calibration certificate, delivered in a tough polypropylene carry case everything you need to start testing in one package. Optional terminal adapters are available for acceptance of a variety of test leads. All models are rated to IP54, making them truly outdoor instruments. They are designed to meet stringent safety standards and are rated CAT IV 100 V. The ground testers have been designed to be easy to use a large selector switch makes selection of 2, 3 or 4 pole tests easy with gloved hands and the design makes the fitting of shorting links to perform 2-pole tests a thing of the past. A large, clear, easy to read LCD and thumb sized test button also make the instruments particularly well suited to the outdoor conditions of ground testing. In addition to this ease of use feature, the instruments automatically check the connection and conditions of the P spike, C spike, and also the level of ground noise, indicating the status on the display. They also include a voltmeter to enable measurement of ground voltage. The DET4TD2 and DET4TR2 can measure resistance from 0.01 ohms to 20 kω, while the DET4TC2 and DET4TCR2 can measure resistance from 0.01 ohms to 200 kω, a key capability for soil resistivity testing. Also, to allow accurate testing in noisy environments, the instruments are capable of rejecting noise up to 40 V peak to peak. The DET4TD2 and DET4TC2 are powered by eight AA batteries which are widely available and also give excellent testing time the status of these batteries is given by a bar graph on the LCD display, allowing the operator to decide when to change the batteries before

they expire. The DET4TR2 and DET4TCR2 are powered from rechargeable AA cells. The battery charger is built in and the instrument is supplied with an AC/DC adapter. For all instruments, the battery status is displayed using a bar-graph. The DET4TC2 and DET4TCR2 include additional capabilities. By using the optional ICLAMP the user can augment the traditional fall-of-potential measurement method with ART (Attached Rod Technique), which allows electrode testing without disconnection and also leakage current measurements down to 0.5 ma. A second optional clamp, the VCLAMP, enables true stakeless (clamp-on) measurements to be made in situations where driving stakes is not practical. The DET4TC2 and DET4TCR2 also feature a backlit display, which extends the operational environment of the instrument to cable cellars and other dark locations. Finally, all units have selectable 25 V or 50 V output for compliance with IEC 61557-5. The 25 V output is required for testing in agricultural environments. The maintenance of an adequate low resistance ground connection is essential to both the protection and performance of any electrical system. Ground testing should be performed both upon installation, to meet design specification, and periodically thereafter in order to maintain service. All Megger models can also perform bonding tests (using an ac signal), to determine that adequate connection has been made from equipment to the grounding system, and can perform soil resistivity tests. This additional function can be used in prospecting, locating, and designing new grounding electrodes and systems. Furthermore, the addition of built-in current clamp capability enables fall of potential testing of attached grounds (ART) without lifting the utility connection and the addition of voltage clamp technology enables stakeless testing from the same instrument. Grounding electrodes from simple to complex systems can be tested, including: Primary and secondary electrical grounding systems Utility pole grounds Lightning protection systems Residential grounds Machinery safety grounds Computer and communication system grounds EMI/RFI system grounds Antenna and pedestal grounds CATV system grounds Model DET4TCR2 shown performing the stakeless ground testing method using only clamps. APPLICATIONS Proper grounding provides many varied benefits to both people and facilities. It lessens the chance of injury due to faulty installation, reduces the likelihood of damage from lightning strikes and induced voltages, improves the performance of computer, communication and other sensitive equipment and protects against static electricity from friction. Over time, ground systems can degrade or become ineffective. Corrosion and weather influences exert mechanical strain on ground rods and cause metallic corrosion. Catastrophic events like lightning strikes or large fault currents can cause instant degradation. In addition, soil resistivity can change over time due to environmental conditions and facility expansion can create different ground system needs. The risks from ground system deterioration include potentially deadly electrical shock situations, plant-wide equipment damage, disruption in the performance of sensitive equipment and heat build-up on a single piece of electrical equipment. FEATURES AND BENEFITS Stakeless testing capability, which allows the operator to use the instrument like a clamp-on tester in applications where the method is viable Attached Rod Technique capability, which allows fall of potential testing without the need to disconnect the ground rod Multiple, user selectable test frequencies allows the operator to find the most effective frequency for making the measurement 200,000 Ω measurement range provides the ability to measure the resistivity of any type of soil User selectable test voltage ensures that the units can be used in agricultural environments Microprocessor control for improved error detection Clear, unambiguous warnings and error indications ensure the reliability of the reading and reduce test time Rugged, weatherproof case to IP54 makes the units truly outdoor instruments Backlit LCD allows for testing in dark environments Noise rejection to 40 V pk to pk allows accurate testing in noisy environments Testing kits and certificates supplied everything needed to start testing immediately Accuracy of 2% of reading enhances reliability of measurements Voltmeter function included allows you to measure the ground voltage and enhances operator safety CAT IV 100V provides increased operator safety

SPECIFICATIONS Resistance range: 0.01 to 200 kω autoranging (0.01 to 20kΩ for models DET4TD2 and DET4TR2) Resistance accuracy: 2P measurements 2% ±3 digits 3P measurements 2% ±3 digits 4P measurements 2% ±3 digits ART measurements 5% ±3 digits Stakeless measurements 7% ±3 digits Maximum probe resistance: DET4TD2 and DET4TR2 Rp limit: 100kΩ (50V output voltage) Rc limit: 100kΩ (50V output voltage) Limits reduced to 50kΩ for 25V output voltage Limits reduced to 5kΩ for 0.01 Ω resolution DET4TC2 and DET4TCR2 Rp limit: 200kΩ (50V output voltage) Rc limit: 200kΩ (50V output voltage) Limits reduced to 100kΩ for 25V output voltage Limits reduced to 5kΩ for 0.01 Ω resolution Earth voltage range: 0 100 V Earth voltage accuracy: 2% ±2 V 2-wire test: Yes, all models 3-wire test: Yes, all models 4-wire test: Yes, all models ART (Attached Rod Technique): DET4TC2, DET4TCR2 Stakeless test: DET4TC2 and DET4TCR2 Ground current range (with current measuring clamp): 0.5 ma to 19.9 A Ground current accuracy: 5% ±3 digits Display: DET4TD2 and DET4TR2: 3-1/2 digit high contrast LCD DET4TC2 and DET4TCR2: 3-1/2 digit high contrast LCD, backlit Test frequency: 94, 105, 111 and 128 Hz (128 Hz for DET4TD2 and DET4TR2) Test voltage: 25 V or 50 V, user selectable (factory setting 50 V) Test current: 450 micro-amps at 25 V or 50 V (selectable), 4.5 ma at 25 V Noise rejection: 40V pk to pk Noise check: Automatic C spike check: Automatic P spike check: Automatic Battery type: 8 1.5 V AA cells (8 1.5 V AA NiMH rechargeable cells DET4TR2 and DET4TCR2) Battery life: 3 hours, 700 consecutive tests Safety: EN61010-1 CAT IV 100 V Terminals: 4 mm plug type (test leads) Ingress protection: IP54 EMC: Meets the requirements of EN61326-1:1998 for use in heavy industrial areas, including amendment 1 Dimensions: 8 x 5.7 x 3.2 in. (203 x 148 x 78 mm) Weight: 2.2 lb (1 kg) Operating temperature range: -5º to +131º F (-15º to +55º C) Storage temperature range: -40º to +158º F (-40º to +70º C) Humidity: 95% RH non-condensing at 104º F (40º C) Standards Compliance Complies with the requirements of KEMA K85B. Complies with the following parts of EN61557, Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures. Part 1 - General requirements Part 5 - Resistance to earth STAKELESS (CLAMP-ON) TESTING The DET4TC2 and DET4TCR2 include stakeless, or clamp-on testing capability. In effect, these models can be operated in the same way as a clamp-on ground tester, eliminating the need to disconnect the ground under test and drive test probes in certain ground system testing applications. This method is also useful when there is insufficient space to perform a classic fallof-potential measurement. In addition the units can be used to measure ground leakage or phase current. The user simply clamps the optional ICLAMP (current clamp) and VCLAMP (voltage clamp) around the ground under test in the manner prescribed in the operator s manual and takes the reading. A defined test voltage is injected into the system using the VCLAMP, inducing a current, I, to flow and be measured by the ICLAMP. The instrument then calculates the approximate resistance of the ground under test. The stakeless method is subject to the same limitations faced by the traditional clamp-on ground tester. It is effective only in situations with multiple grounds in parallel and cannot be proofed like a fall-of-potential test. In situations where the stakeless method reading is questionable, a full fall-of-potential test is recommended. The advantage of the DET4TC2 and DET4TCR2 is that the units include both test methods in a single instrument, making them the most versatile units available. Current measuring clamp (inset) for ART testing capability

ART (ATTACHED ROD TECHNIQUE) TESTING CAPABILITY The DET4TC2 and DET4TCR2 include the additional testing capability that we have termed ART, for Attached Rod Technique. A nagging problem with traditional ground testing has been the requirement to lift (i.e., disconnect) the utility connection. Once the grounding conductor (the main conductor that connects the facility to the ground rod or grid) has been attached to the grounding electrode, the utility ground becomes a parallel resistance. The utility neutral is typically bonded to the ground bus at the service entrance and this connection, during a ground test, causes test current to flow back through the utility ground as well as through the test electrode. Test current divides according to Law of Parallel Resistance, but the tester makes its measurement based on total current flow. The reading is the combined parallel resistance of the on-site ground and the utility protection. This is a valid measurement, but not of the test electrode exclusively. This poses a considerable problem in many common testing situations. If a commissioning test were required to determine if design specifications had been met for a new facility, such a reading would be insufficient. Lightning protection requiring a short, straight path into the earth, could also not be properly validated. But lifting the utility connection poses several problems, not the least of which is the breaking of what is often a welded bond, in addition to the temporary loss of protection. Clamp-on ground testers, which measure ground resistance by clamping around the rod and inducing a test current onto it, are only a limited solution. They can accurately measure resistance of a single rod in a parallel system by inducing the test current onto the clamped rod and utilizing all the parallel grounds as the return. Collectively, these returns, typically the multiple grounds of the utility, contribute little to the loop measurement. This is essentially the reverse of the operation of a traditional tester, which uses the current probe as the return while current goes to ground through all parallels collectively. This technique solves the problem of separately measuring an attached rod, but leaves the problem that it cannot be proven. A clamp-on measurement has to be accepted on faith and its reliability is based squarely on the knowledge and experience of the operator, leaving a large margin for human error. In complex, multiply connected grids and other grounding schemes, return paths may exist that are entirely metallic, not including earth at all. The clamp-on test current will circulate through such paths and give a reading, essentially a continuity reading of the grid structure having nothing to do with soil resistance. Such readings will be low, and appear to the uninformed as acceptable grounds. The responsibility for making these determinations falls squarely on the operator. But even when properly addressed, there is no way of demonstrating the competence of the readings to a third party, such as a client. They must simply be accepted. The ART testing capability combines the advantages of both of these technologies to produce a method that can reliably measure an attached ground, and prove it! A built-in clamp input, used in conjunction with the optional ICLAMP accessory, connected below the point of separation of the parallel test currents, measures only the current flowing through the test ground, not that going back through the utility. This current value is then used by the microprocessor to calculate ground resistance, strictly in accordance with Fall of Potential or its derivative procedures, supported by IEEE Standard 81 for proper ground testing, and subject to the appropriate proofs. The ART method employs leads and probes just as does any traditional tester. Ground resistance can be profiled and graphed by moving the potential probe against the position of the current probe, and a Fall of Potential graph, Slope Method mathematical proof, or any of the other proven methods utilized to demonstrate the accuracy of the test. The only thing different from the operation of a familiar, traditional ground tester is that the clamp permits separation of the test currents in an attached or otherwise parallel-grounded system. This technique enables local grounds to be tested without lifting the utility connection, yet with the ease, reliability and confidence of a separate commissioning test. Current measuring clamp (inset) for ART testing capability

SELECTION GUIDE Model No. DET4TD2 DET4TR2 DET4TC2 DET4TCR2 Cat. No. 1000-347 1000-324 1000-345 1000-346 2-Pole Measurement 3-Pole Measurement 4-Pole Measurement Soil Resistivity Tests ART (Attached Rod Technique) Capability Stakeless (Clamp-on) Measurement Capability Resistance Range 0.01 to 20,000 Ω 0.01 to 200,000 Ω Ground Voltage Range Ground Current Range (with ICLAMP) Capability 0 to 100 V 0.5 ma to 19.9 A Output Selectable Voltage (25/50 V) Test Frequency 128 Hz 94, 105, 111, 128 Hz Power Supply Alkaline Batteries Rechargeable Batteries Noise Rejection 40 V Peak-to-Peak Safety Rating CAT IV 100 V Ingress Protection Rated to IP54 Hard Carry Case Included Accessories Test Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes Certificate of Calibration Warranty 3 Year CONFIGURATION OPTIONS Model No. Cat. No. Description DET4TD2 1000-347 Instrument plus hard carry case, leads and spikes DET4TD2+Adaptors 1000-360 Instrument plus hard carry case and 4 right angle terminal adaptors; leads and spikes not included DET4TR2 1000-324 Instrument plus hard carry case, external ac/dc adaptor, leads and spikes DET4TR2+Adaptors 1000-401 Instrument plus hard carry case, external ac/dc adaptor, and 4 right angle terminal adaptors; leads and spikes not included DET4TC2 1000-345 Instrument plus hard carry case, leads and spikes DET4TC2+Adaptors 1000-402 Instrument plus hard carry case and 4 right angle terminal adaptors; leads and spikes not included DET4TC2+Clamps 1000-365 Instrument plus hard carry case, leads and spikes, 4 right angle terminal adaptors, field calibrator, ICLAMP and VCLAMP DET4TC2+Kit 1000-404 DET4TC2+Clamps plus professional ground/earth testing kit* DET4TCR2 1000-346 Instrument plus hard carry case, external ac/dc adaptor, leads and spikes DET4TCR2+Adaptors 1000-403 Instrument plus hard carry case, external ac/dc adaptor, and 4 right angle terminal adaptors; leads and spikes not included DET4TCR2+Clamps 1000-366 Instrument plus hard carry case, leads and spikes, external ac/dc adaptor, 4 right angle terminal adaptors, field calibrator, ICLAMP and VCLAMP DET4TCR2+Kit 1000-405 DET4TCR2+Clamps plus professional ground/earth testing kit* *The Professional Ground Testing Kit includes two 164 ft (50 m) leads and two 98 ft (30 m) leads on retractable reels, four auger-style ground spikes, a tape measure and a separate hard carry case. NOTE: Using the ICLAMP allows the operator to make ART measurements. Using the ICLAMP and VCLAMP allows the operator to make stakeless (clamp-on) measurements.

DET4TC2 OPERATION Test lead connections (at rear) LCD Display Resistance measurement settings 25V / 50V output voltage select button Test button Selector switch Frequency select button Backlight control button Voltage and current measurement settings DET4TC2 DISPLAY EXAMPLE Output voltage indicator Ruptured fuse indicator Warning - refer to user manual Battery charge indicator Measuring range Over/under range indicator Potential probe resistance indicator (OK or high) Current probe resistance (OK or high) Ground noise voltage indicator (OK or high)

OPTIONAL ACCESSORY KITS Professional Kit Cat. No. 6320-245 Red, black, yellow, green cable reels (50 m); earth electrode leads (4 m green, 4 mm shrouded plug and large croc clip); 4 auger-style spikes; molded polyethylene carrying case; fiberglass measuring tape, 50 m Each instrument comes complete with three sets of leads, two test spikes, instruction manual CD, and a rugged carrying case, (current measuring clamp, shown, is an optional accessory for performing the ART testing capability using the DET4TC2 and DET4TCR2 only.) Soil Resistivity Kit Cat. No. 250586 Set of four test leads, 50 ft. (15 m); two pair of 20 in. (51 cm) ground rods; padded case to hold instrument, leads and rods Terminal Adapters are optional accessories used to allow the DET4 Series units terminals to accept alternative cable connections. Deluxe Kit, Cat. No. 250581 Set of three color-coded test leads, 25, 50, 100 ft. (8, 15, 30 m); two 20-in. (51 cm) ground rods; padded case to hold instrument, leads and rods Standard Kit, Cat. No. 250579 Three color-coded test leads, 25, 50, 100 ft. (8, 15, 30 m); two 20-in. (51 cm) ground rods; canvas accessory case for leads and rods only Standard Kit Cat. No. EV6310-755 Hammer, 2.5 lb (1.13 kg); four galvanized steel spikes, 0.5 in. (12 mm); two spike extractors; four leads in carrying case

ORDERING INFORMATION Item (Qty) Cat. No. Item (Qty) Cat. No. DET4TD2 1000-347 DET4TD2+Adaptors 1000-360 DET4TR2 1000-324 DET4TR2+Adaptors 1000-401 DET4TC2 1000-345 DET4TC2+Adaptors 1000-402 DET4TC2+Clamps 1000-365 DET4TC2+Kit 1000-404 DET4TCR2 1000-346 DET4TCR2+Adaptors 1000-403 DET4TCR2+Clamps 1000-366 DET4TCR2+Kit 1000-405 See Configuration Options chart for detailed information Optional Accessories Current measuring clamp and connecting lead for ART testing method ICLAMP Voltage inducing clamp, calibration check PCB (two-clamp measurements) and connecting lead VCLAMP Calibration check box 6220-824 Right angled terminal adaptor set 6220-803 Auxiliary 12V socket charger (DET4TR2 and DET4TCR2 only) 6280-375 Standard accessory kit (leads, rods, canvas accessory case for leads & rods) 250579 Deluxe accessory kit (leads, rods, padded case) 250581 Standard accessory kit (hammer, spikes, leads) EV6310-755 Professional ground testing kit (2 x 50m, 2 x 30m, 4 auger stakes, carry case) 6320-245 Soil resistivity kit (leads, rods, padded case) 250586 Getting Down to Earth a Megger guide to earth testing AVTM25-TA Replacement hard carry case 5410-429 Replacement calibration check PCB (two-clamp measurements) 6220-831 Replacement ground test stakes (x2) for included kit (200mm, 8mm dia) 6220-804 Replacement ground test leads (x4) for included kit (15m, 10m, 10m, 3m) 6220-806 Replacement auger stakes (x2) for professional kit 6220-839 Replacement cable reel (50m, red cable) for professional kit 6220-840 Replacement cable reel (50m, black cable) for professional kit 6220-841 Replacement cable reel (30m, green cable) for professional kit 6220-843 Replacement cable reel (30m, yellow cable) for professional kit 6220-842 UK Archcliffe Road, Dover CT17 9EN England T +44 (0) 1 304 502101 F +44 (0) 1 304 207342 UKsales@megger.com UNITED STATES 4271 Bronze Way Dallas, TX 75237-1019 USA T 1 800 723 2861 (USA only) T +1 214 333 3201 F +1 214 331 7399 USsales@megger.com OTHER TECHNICAL SALES OFFICES Täby SWEDEN, Norristown USA, Sydney AUSTRALIA, Toronto CANADA, Trappes FRANCE, Kingdom of BAHRAIN, Mumbai INDIA, Johannesburg SOUTH AFRICA, and Chonburi THAILAND ISO STATEMENT Registered to ISO 9001:2000 Reg no. Q 09250 Registered to ISO 14001 Reg no. EMS 61597 DET4T2SERIES_DS_USen_V01 www.megger.com Megger is a registered trademark