PS S Intellimod Module Dual-In-Line Intelligent Power Module 20 Amperes/600 Volts

Similar documents
PS , PS A, PS C Intellimod Module Dual-In-Line Intelligent Power Module 20 Amperes/600 Volts

PS , PS A, PS C Intellimod Module Dual-In-Line Intelligent Power Module 5 Amperes/600 Volts

PS21963-S Intellimod Module Dual-In-Line Intelligent Power Module 10 Amperes/600 Volts

C L DETAIL "B" TERMINAL CODE 1 (VNC) 2 VUFB 3 VVFB 4 VWFB 5 UP 6 VP 7 WP 8 VP1 9 VNC* 10 UN 11 VN 12 WN 13 VN1 HEATSINK SIDE

PS , PS A, PS C Intellimod Module Dual-In-Line Intelligent Power Module 3 Amperes/600 Volts

PS21353-GP. Intellimod Module Dual-In-Line Intelligent Power Module 10 Amperes/600 Volts

AB (2 PLACES) 30 NC 31 P 33 V 34 W

PS21265-P PS21265-AP Intellimod Module Dual-In-Line Intelligent Power Module 20 Amperes/600 Volts

PS21965, PS21965-A, PS21965-C Intellimod Module Dual-In-Line Intelligent Power Module 20 Amperes/600 Volts

PS21867-P. Intellimod Module Dual-In-Line Intelligent Power Module 30 Amperes/600 Volts

N P HEATSINK SIDE 25 UN 26 VUFB 27 UP 30 NC 31 NC 32 NC 33 NC 34 NC 35 NC 28 U(VUFS) 29 NC

PS21562-P. Intellimod Module Dual-In-Line Intelligent Power Module 5 Amperes/600 Volts

PS21767 Intellimod Module Dual-In-Line Intelligent Power Module 30 Amperes/600 Volts

N 36 NU 37 W 38 V 39 U 40 P 41 U 42 V

Applied between V UFB -V UFS, V VFB -V VFS,V WFB -V WFS. Applied between U P,V P,W P -V PC, U N,V N,W N -V NC

PS11035 Intellimod Module Application Specific IPM 20 Amperes/600 Volts

Mitsubishi Semiconductors <Dual-In-Line Package Intelligent Power Module> PS21865 Transfer-Mold Type Insulated Type

PS11036 Intellimod Module Application Specific IPM 30 Amperes/600 Volts

U (2 TYP.) T WFO VUPC IN F O GND GND OUT OT OUT OT S I

MITSUBISHI INTELLIGENT POWER MODULES PM800HSA060 FLAT-BASE TYPE INSULATED PACKAGE

Application Note Mitsubishi Semiconductors <Dual-In-Line Package Intelligent Power Module> PS21867 Transfer-Mold Type Insulated Type

Y Y D T SQ PIN (10 PLS) L N TERMINAL CODE 5 : FNO 4 : VNC N 3 : CN1 2 : NC 1 : VN1 5 : FPO 4 : VPC P 3 : CP1 2 : NC 1 : VP1. FWDi IGBT C2E1.

U P V VPI VFO WFO UP UFO V VPC GND GND

U P V VPI VFO R (2 TYP.) WFO UP UFO V VPC GND GND

PM30CSJ060 Intellimod Module Three Phase IGBT Inverter Output 30 Amperes/600 Volts

V VPI V (14 TYP.) VFO R (2 TYP.) WFO UP UFO V VPC GND GND GND GND GND GND VCC

PM300DSA060 Intellimod Module Single Phase IGBT Inverter Output 300 Amperes/600 Volts

T - 4 TYP. XØ (2 PLACES) W SQ. PIN (10 PLACES) TERMINAL CODE 1. VN1 2. SNR 3. CN1 4. VNC 5. FNO VP1 RFO AMP E2 C2E1 C1

PS22A78-E Transfer-Mold Type Insulated Type

PM25RSB120 Intellimod Module Three Phase + Brake IGBT Inverter Output 25 Amperes/1200 Volts

PS21562-SP PS21562-SP. APPLICATION AC100V~200V inverter drive for small power motor control. PS21562-SP

APPLICATION AC100V~200V three-phase inverter drive for small power motor control (1.96) 17.7 (3.5) 35.9 ±0.5 (5.5)

SLIMDIP-L TRANSFER MOLDING TYPE INSULATED TYPE

V VPC V FO V WPI W FO W UP UFO V VPI GND GND GND GND V CC OUT OUT. Dimensions Inches Millimeters L

TYP K "T" (4 TYP) TYP TYP UP UFO V VPI GND GND GND GND IN V CC OUT S I

PSS15S92F6-AG PSS15S92E6-AG TRANSFER MOLDING TYPE INSULATED TYPE

PS21A79 MAIN FUNCTION AND RATINGS 3 phase inverter with N-side open emitter structure 600V / 50A (CSTBT)

APPLICATION AC100V~200V three-phase inverter drive for small power motor control (1.96) 17.7 (12.78) (3.5) 35.9 ±0.5 (5.5) (13.5)

PM75DSA120 Intellimod Module Single Phase IGBT Inverter Output 75 Amperes/1200 Volts

< Dual-In-Line Package Intelligent Power Module > PSS25SA2FT TRANSFER MOLDING TYPE INSULATED TYPE

PSS10S72FT TRANSFER MOLDING TYPE INSULATED TYPE

PS22A74. < Dual-In-Line Package Intelligent Power Module > Publication Date : January 2012 TRANSFER MOLDING TYPE INSULATED TYPE

PSS15MC1FT TRANSFER MOLDING TYPE INSULATED TYPE

PSS20S51F6 / PSS20S51F6-C TRANSFER MOLDING TYPE INSULATED TYPE

PS21661-RZ/FR PS21661-FR. APPLICATION AC100V~200V, three-phase inverter drive for small power motor control.

PM50RSK060 Intellimod Module Three Phase + Brake IGBT Inverter Output 50 Amperes/600 Volts

PSM03S93E5-A TRANSFER MOLDING TYPE INSULATED TYPE

FBA42060 PFC SPM 45 Series for Single-Phase Boost PFC

PSS25NC1FT TRANSFER MOLDING TYPE INSULATED TYPE

P Q SIGNAL TERMINAL 1 F O (L) 5 F O (H) V S DETAIL "A"

FPAM30LH60 PFC SPM 2 Series for 2-Phase Interleaved PFC

L M DETAIL "A" SIGNAL TERMINAL 3 E(L) 4 V D 5 G(H) 6 F O (H) 7 E(H) 8 OPEN

L M DETAIL "A" SIGNAL TERMINAL 3 E(L) 4 V D 5 G(H) 6 F O (H) 7 E(H) 8 OPEN

L M 1 F O (L) 5 F O (H) DETAIL "A"

FPDB40PH60B PFC SPM 3 Series for 2-Phase Bridgeless PFC

FPDB30PH60 PFC SPM 3 Series for 2-Phase Bridgeless PFC

Smart Pack Electric Co., Ltd <Intelligent Power Module> SPE10S60F-A TRANSFER-MOLD TYPE FULL PACK TYPE

LDIP- IPM IM (Preliminary)

APPLICATION AC100V~200V three-phase inverter drive for small power motor control. (2.2) 21.4 ±0.5 (10) (11) (10) (4.65) (2.9) 34.9 ± ±0.5 (1.

FPAB30BH60 PFC SPM 3 Series for Single-Phase Boost PFC

FPAB30BH60B PFC SPM 3 Series for Single-Phase Boost PFC

FSBS3CH60 Motion SPM 3 Series Features

PM50CLA120. APPLICATION General purpose inverter, servo drives and other motor controls PM50CLA120 FEATURE MITSUBISHI <INTELLIGENT POWER MODULES>

S R V U T DETAIL "A" AF AE E1C2 (33) E1C2 (32) Dimensions Inches Millimeters

FSBB10CH120D Motion SPM 3 Series

Smart Pack Electric Co., Ltd <Intelligent Power Module> SPE05M50F-A TRANSFER-MOLD TYPE FULL PACK TYPE

FSBB30CH60DF. Motion SPM 3 Series. FSBB30CH60DF Motion SPM 3 Series. Features. General Description. Applications.

PP400B060-ND. H-Bridge POW-R-PAK IGBT Assembly 400 Amperes/600 Volts

CP15TD1-24A. DIP-CIB 3Ø Converter + 3Ø Inverter + Brake 15 Amperes/1200 Volts

PM200CVA060 PM200CVA060. APPLICATION General purpose inverter, servo drives and other motor controls LABEL PM200CVA060

FSAM30SH60A Motion SPM 2 Series

Motion-SPM FPAB30BH60B. Smart Power Module(SPM ) for Front-End Rectifier. General Description. Features. Applications. April Fig. 1.

TENTATIVE PP225D120. POW-R-PAK TM 225A / 1200V Half Bridge IGBT Assembly. Description:

PM25CLA120. APPLICATION General purpose inverter, servo drives and other motor controls PM25CLA120 MITSUBISHI <INTELLIGENT POWER MODULES>

AIM5C05B060N1 Dual-In-Line Package Intelligent Power Module

PS21963-ET/-AET/-CET/-ETW TRANSFER-MOLD TYPE INSULATED TYPE

CP10TD1-24A. DIP-CIB 3Ø Converter + 3Ø Inverter + Brake 10 Amperes/1200 Volts

QID Dual IGBT HVIGBT Module 85 Amperes/6500 Volts

V (4TYP) U (5TYP) V 0.28 Dia. 7.0 Dia.

PS21265-P/AP TRANSFER-MOLD TYPE TYPE INSULATED TYPE TYPE

Description of Terminal Symbols and Terminology

PM75CL1A120 FLAT-BASE TYPE INSULATED PACKAGE

M81500FP Intellimod HVIC Single Chip Inverter

FSBF15CH60BT. Motion SPM 3 Series. FSBF15CH60BT Motion SPM 3 Series. Features. General Description. Applications.

Technical. Application. Assembly. Availability. Pricing. Phone

FNA V Motion SPM 2 Series. FNA V Motion SPM 2 Series. Features. General Description. Applications.

PM150RLB060. APPLICATION General purpose inverter, servo drives and other motor controls PM150RLB060.

Features: Phase A Phase B Phase C -DC_A -DC_B -DC_C

CHAPTER 1 : INTRODUCTION...

FSB44104A Motion SPM 45 LV Series

SLLIMM small low-loss intelligent molded module IPM, 3-phase inverter - 15 A, 600 V short-circuit rugged IGBT. Description. Table 1.

<Dual-In-Line Package Intelligent Power Module> Super mini DIPIPM Ver.6 Series APPLICATION NOTE PSS**S92E6-AG/ PSS**S92F6-AG.

AIM5D05B060M1S. Dual-In-Line Package Intelligent Power Module. Features. External View. Applications. Internal Equivalent Circuit / Pin Configuration

PS21869-P/AP PS21869-P/AP. APPLICATION AC100V~200V inverter drive for small power motor control. PS21869

CM600YE2N-12F / CM600YE2P-12F TLI-Series (Three Level Inverter) IGBT 600 Amperes/600 Volts

TENTATIVE PP800D120-V01

<Dual-In-Line Package Intelligent Power Module> 1200V LARGE DIPIPM Ver.4 Series APPLICATION NOTE PS22A7. Table of contents

Chapter 1. Product Outline

IAP200T120 SixPac 200A / 1200V 3-Phase Bridge IGBT Inverter

Large DIPIPM TM Ver. 4 for Photovoltaic Application

Transcription:

Dual-In-Line Intelligent Power Module R O A D N P X K C L AF R P 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 18 19 20 U HEATSINK SIDE Outline Drawing and Circuit Diagram Dimensions Inches Millimeters A 1.50±0.02 38.0±0.5 B 0.94±0.02 24.0±0.5 C 0.14 3.5 D 1.40 35.56 E 0.57±0.02 14.4±0.5 F 0.74±0.02 18.9±0.5 G 1.15±0.02 29.2±0.5 H 0.14 3.5 J 0.13 3.3 K 0.016 0.4 L 0.06±0.02 1.5±0.05 M 0.031 0.8 21 1 (VNC) 6 VP 2 VUFB 7 WP 3 VVFB 8 VP1 4 VWFB 9 VNC 5 UP 10 UN N 1.39±0.019 35.0±0.3 O 0.07±0.008 1.778±0.2 P 0.02 0.5 Q 0.47 12.0 R 0.011 0.28 22 11 VN 12 WN 13 VN1 14 FO 15 CIN DETAIL "A" 23 DETAIL "C" Z 24 TERMINAL CODE 16 VNC 17 VNO 18 NW 19 NV 20 NU T 25 AH 21 W 22 V 23 U 24 P 25 NC AE Q AA B AB W V G K E F DETAIL "A" E Y AC W H M HEATSINK SIDE Dimensions Inches Millimeters S 0.12 2.8 T 0.024 0.6 U 0.1±0.008 2.54±0.2 V 1.33±0.02 33.7±0.5 W 0.03 0.678 X 0.04 1.0 Y 0.05 1.2 Z 1.40 35.56 AA 0.22±0.02 5.5±0.5 AB 0.37±0.02 9.5±0.5 AC 0 ~ 5 0 ~ 5 AD 0.06 Min. 1.5 Min. AE 0.05 1.2 AF 0.063 Rad. 1.6 Rad. AG 0.118 Min. 3.0 Min. AH 0.098 Min. 2.5 Min. J AD DETAIL "B" DETAIL "B" AG S DETAIL "C" Description: DIP-IPMs are intelligent power modules that integrate power devices, drivers, and protection circuitry in an ultra compact dual-in-line transfer-mold package for use in driving small three phase motors. Use of 5th generation IGBTs, DIP packaging, and application specif ic HVICs allow the designer to reduce inverter size and overall design time. Features: Compact Packages Single Power Supply Integrated HVICs Direct Connection to CPU Reduced R th Applications: Refrigerators Air Conditioners Small Servo Motors Small Motor Control Ordering Information: is a 600V, 20 Ampere short pin DIP Intelligent Power Module.

Absolute Maximum Ratings, T j = 25 C unless otherwise specified Characteristics Symbol Units Power Device Junction Temperature* T j -20 to 150 C Storage Temperature T stg -40 to 125 C Case Operating Temperature (Note 1) T C -20 to 100 C Mounting Torque, M3 Mounting Screws 6.9 in-lb Module Weight (Typical) 10 Grams Heatsink Flatness (Note 2) -50 to 100 µm Self-protection Supply Voltage Limit (Short Circuit Protection Capability)** V CC(prot.) 400 Volts Isolation Voltage, AC 1 minute, 60Hz Sinusoidal, Connection Pins to Heatsink Plate V ISO 1500 Volts *The ma ximum junction temperature rating of the power chips integrated within the DIP-IPM is 150 C (@T C 100 C). However, to ensure safe operation of the DIP-IPM, the average junction temperature should be limited to T j(avg) 125 C (@T C 100 C). **V D = 13.5 ~ 16.5V, Inverter Part, T j = 125 C, Non-repetitive, Less than 2µs IGBT Inverter Sector Collector-Emitter Voltage V CES 600 Volts Each Collector Current, ± (T C = 25 C) I C 20 Amperes Each Peak Collector Current, ± (T C = 25 C, Less than 1ms) I CP 40 Amperes Supply Voltage (Applied between P - N) V CC 450 Volts Supply Voltage, Surge (Applied between P - N) V CC(surge) 500 Volts Collector Dissipation (T C = 25 C, per 1 Chip) P C 35.7 Watts Control Sector Supply Voltage (Applied between V P1 -V NC, V N1 -V NC ) V D 20 Volts Supply Voltage (Applied between V UFB -U, V VFB -V, V WFB -W) V DB 20 Volts Input Voltage (Applied between U P, V P, W P -V NC, U N, V N, W N -V NC ) V IN -0.5 ~ V D +0.5 Volts Fault Output Supply Voltage (Applied between F O -V NC ) V FO -0.5 ~ V D +0.5 Volts Fault Output Current (Sink Current at F O Terminal) I FO 1 ma Current Sensing Input Voltage (Applied between C IN -V NC ) V SC -0.5 ~ V D +0.5 Volts Note 1 T C Measure Point Note 2 Flatness Measurement Position CONTROL TERMINALS DIP-IPM MEASUREMENT POINT 11.6mm 3.0mm + 4.6mm IGBT CHIP FWDi CHIP T C POINT HEATSINK SIDE HEATSINK PLACE TO CONTACT A HEATSINK POWER TERMINALS + HEATSINK

Electrical and Mechanical Characteristics, T j = 25 C unless otherwise specified Characteristics Symbol Test Conditions Min. Typ. Max. Units IGBT Inverter Sector Collector-Emitter Saturation Voltage V CE(sat) V D = V DB = 15V, I C = 20A, V IN = 5V, T j = 25 C 1.70 2.20 Volts V D = V DB = 15V, I C = 20A, V IN = 5V, T j = 125 C 1.80 2.30 Volts Diode Forward Voltage V EC -I C = 20A, V IN = 0V 1.90 2.40 Volts Inductive Load Switching Times t on 0.70 1.30 1.90 µs t rr V CC = 300V, V D = V DB = 15V, 0.30 µs t C(on) I C = 20A, T j = 125 C, 0.50 0.75 µs t off V IN = 0 5V, Inductive Load, 1.60 2.20 µs t C(off) 0.40 0.75 µs Collector Cutoff Current I CES V CE = V CES, T j = 25 C 1.0 ma Control Sector V CE = V CES, T j = 125 C 10 ma Circuit Current I D V IN = 5V Total of V P1 -V NC, V N1 -V NC 2.80 ma V D = V DB = 15V V UFB -U, V VFB -V, V WFB -W 0.55 ma V IN = 0V Total of V P1 -V NC, V N1 -V NC 2.80 ma V UFB -U, V VFB -V, V WFB -W 0.55 ma Fault Output Voltage V FOH V SC = 0V, F O Terminal Pull-up to 5V by 10kΩ 4.9 Volts V FOL V SC = 1V, I FO = 1mA 0.95 Volts Input Current I IN V IN = 5V 0.70 1.00 1.50 ma Short Circuit Trip Level* V SC(ref) V D = 15V* 0.43 0.48 0.53 Volts Supply Circuit Under-voltage UV DBt Trip Level, T j 125 C 10.0 12.0 Volts UV DBr Reset Level, T j 125 C 10.5 12.5 Volts UV Dt Trip Level, T j 125 C 10.3 12.5 Volts UV Dr Reset Level, T j 125 C 10.8 13.0 Volts Fault Output Pulse Width** t FO 20 µs ON Threshold Voltage V th(on) Applied between 2.1 2.6 Volts OFF Threshold Voltage V th(off) U P, V P, W P -V NC, 0.8 1.3 Volts ON/OFF Threshold Hysteresis Voltage V th(hys) U N, V N, W N -V NC 0.35 0.65 Volts * Short Circuit protection is functioning only for the low-arms. Please select the value of the external shunt resistor such that the SC trip level is less than 1.7 times the current rating. **Fault signal is asserted only for a UV or SC condition on the low side. On a SC fault the FO duration will be 20µsec. On a UV condition the fault signal will be asserted as long as the UV condition exists or for 20µsec, whichever is longer. 3

Thermal Characteristics Characteristic Symbol Condition Min. Typ. Max. Units Junction to Case R th(j-c)q Inverter IGBT (Per 1/6 Module) 2.8 C/Watt R th(j-c)d Inverter FWDi (Per 1/6 Module) 3.9 C/Watt Recommended Conditions for Use Characteristic Symbol Condition Min. Typ. Max. Units Supply Voltage V CC Applied between P-N Terminals 0 300 400 Volts Control Supply Voltage V D Applied between V P1 -V NC, V N1 -V NC 13.5 15.0 16.5 Volts V DB Applied between V UFB -U, 13.0 15.0 18.5 Volts V VFB -V, V WFB -W Control Supply Variation dv D, dv DB -1 1 V/µs Arm Shoot-through Blocking Time t DEAD For Each Input Signal, T C 100 C 1.5 µs Allowable Minimum Input P WIN(on) 0.5 µs Pulse Width* P WIN(off) 0.5 µs V NC Voltage Variation V NC Between V NC -N (Including Surge) -5.0 5.0 Volts *DIP-IPM might not make response or work properly if the input signal pulse width is less than the recommended minimum value.

Application Circuit

Protection Function Timing Diagrams Short-Circuit Protection (Lower-arms only with the external shunt resistor and RC filter) LOWER-ARMS CONTROL INPUT A6 A7 PROTECTION CIRCUIT STATE SET INTERNAL IGBT GATE A3 A1 A2 SC A4 OUTPUT CURRENT I C A8 SENSE VOLTAGE OF THE SHUNT RESISTOR FAULT OUTPUT F O A5 SC REFERENCE VOLTAGE CR CIRCUIT TIME CONTAINS DELAY (NOTE) A1: Normal operation IGBT turn on and conducting current. A2: Short-circuit current detected (SC trigger). A3: IGBT gate hard interrupted. A4: IGBT turn off. A5: F O output with a fixed pulse width of t FO(min) = 20µs. A6: Input L IGBT off. A7: Input H IGBT on is blocked during the F O output period. A8: IGBT stays in off state. Under-Voltage Protection (Lower-side, UV D ) CONTROL INPUT PROTECTION CIRCUIT STATE SET UV Dr CONTROL SUPPLY VOLTAGE V D B1 UV Dt B3 B6 B2 B4 B7 OUTPUT CURRENT I C FAULT OUTPUT F O B5 B1: Control supply voltage rise After the voltage level reaches UV Dr, the drive circuit begins to work at the rising edge of the next input signal. B2 : Normal operation IGBT turn on and conducting current. B3: Under-voltage trip (UV Dt ). B4: IGBT turn off regardless of the control input level. B5: F O output during under-voltage period, however, the minimum pulse width is 20µs. B6: Under-voltage reset (UV Dr ). B7: Normal operation IGBT turn on and conducting current.

Protection Function Timing Diagrams Under-Voltage Protection (Upper-side, UV DB ) CONTROL INPUT PROTECTION CIRCUIT STATE SET CONTROL SUPPLY VOLTAGE V DB UV DBr C1 UV Dt C3 C5 C2 C4 C6 OUTPUT CURRENT I C FAULT OUTPUT F O HIGH LEVEL (NO FAULT OUTPUT) C1: Control supply voltage rises After the voltage level reaches UV DBr, the drive circuit begins to work at the rising edge of the next input signal. C2: Normal operation IGBT turn on and conducting current. C3: Under-voltage trip (UV DBt ). C4: IGBT stays off regardless of the control input level, but there is no F O signal output. C5: Under-voltage reset (UV Dr ). C6: Normal operation IGBT turn on and conducting current. Typical Interface Circuit 5V LINE MCU 10kΩ DIP-IPM U P, V P, W P, U N, V N, W N 3.3kΩ (MIN) F O V NC (LOGIC) NOTE: RC coupling at each input (parts shown dotted) may change depending on the PWM control scheme used in the application and the wiring impedance of the printed circuit board. The DIP-IPM input signal section integrates a 3.3kΩ (min) pull-down resistor. Therefore, when using an external filtering resistor, care must be taken to satisfy the turn-on threshold voltage requirement. Wiring Method Around Shunt Resistor Wiring inductance should be less than 10nH. (Equivalent to the inductance of a copper pattern with length = 17mm, width = 3mm, and thickness = 100µm.) DIP-IPM NU Shunt Resistors V NC NV NW Please make the connection of shunt resistor close to V NC terminal. 7