Technical data. Standards: IEC/EN thermoplastic Protection class: IP 67 to EN Termination: cable LiYY 2 x 0.25 mm 2, length 1 m

Similar documents
Datasheet - BN 20-RZ. Ordering details. Approval. Global Properties :52:27h. Magnetic reed switch / BN 20.

Data Sheet for Precision Potentiometer

ES Series Features Detecting distance twice that of conventional

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton

M2 Assembly. M2 Sub-Assemblies mm Belt Sub-Assembly mm Belt Sub-Assembly Spider Sub-Assembly... 4

Inductive proximity switches IFL

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts

EAO Product Information. Series 84

Data Sheet for Angle Sensors

Vdc 9 to 30 (unregulated) and 5 ±0.5 (regulated) Supply voltage

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

Magnetic Switches. General Information on BERNSTEIN Magnetic Switches. Electromechanical and electronic variants

High Accuracy Positioning Sensors EG Series Features

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

TRD-J Series Incremental Encoders

NOVOTURN Multiturn Sensor non-contacting. Series RSM-2800

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

Inductive Proximity Sensor

Inductive Proximity Sensor

Description. 2-wire type reduces wiring cost Wiring time and labour is reduced by one-third compared to 3-wire types. Wiring errors also decrease.

TRD-N/NH Series Incremental Encoders

TRD-J Series Incremental Encoders

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Position switches FM series

SRS SEALED ROTARY SENSORS

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

Characteristics 5 TeSys k contactors and reversing contactors

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

Linear Sliders -Trac-SGT-F

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

XXXX e. X d.. X X X a

Rotary Measurement Technology Incremental Encoders

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

847H. Description. Features. Specifications

Rotary Position Technology Incremental Encoders

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable

Model PLM5113N PETROL LAWN MOWER

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

NOVOHALL Rotary Sensor touchless transmissive. Series RFX-6900

To install new top weight plate bushings in G7 strength units.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Long-distance Separate-amplifier Proximity Sensors ES Series Features Detecting distance twice that of conventional

10A to 40A hockey puck type FEATURES

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Long Range Metal Body Sensor

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

Absolute Encoders - Singleturn

Safety switches with slotted hole lever

E2C-EDA. Proximity Sensor with Separate Amplifier Enables Easily Making Highprecision Sensitivity Settings. Ordering Information

Capacitive Proximity Sensor

Phone: Fax: Web: -

E3S-C. Built-in Amplifier Photoelectric Sensor. Water- and Oil-resistive Photoelectric Sensor with Metal Housing Ensuring Long Sensing Distance

Relay Types. Reed V23100-V4 Relay. Typical applications. Features. DIP version (flat) DIP version (high) SIL version.

Electronic Installation Buzzer

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Absolute encoders multiturn

Directional valves Electrically operated Series 563, 565, 567. Brochure

Temposonics. Magnetostrictive Linear Position Sensors. EP2 CANopen Data Sheet

Absolute Encoders Multiturn

RoHS. High shaft load capacity. Shock / vibration resistant

AX1001. Smith/Functional training Combo-free weight ASSEMBLY INSTRUCTIONS

E2Q5. Square Proximity Sensor. Long Distance Square Inductive Proximity Sensor. Ordering Information

HQ Pole Upgrade Kit for HQ Adjustable Table and HQ QuilTable Assembly Instructions 1

Sensor technologies Proximity sensors Series ST9. Brochure

The Mind Project s Iris 1 Robotic Arm. Packing List Assembly instructions

Valve Island with Electronic I/O

FOR RELIABLY MEASURING +

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

The Mind Project s Iris 1 Robotic Arm. Assembly instructions Step 1

E2S World's Smallest Square Sensor with Built-in Amplifier

How-To Set-Up Vise Sensors, Omil-8mm Sensors Step 1 - Summary

LR Position Switches TECHNICAL DATASHEET

#46572 HI-HILO-3 Adjustable Pneumatic Workstation

PHOTOELECTRIC S300 MAXI SENSORS APPLICATIONS.

Vert-X 22E - 5V / PWM. Applications Wind vanes Valve control Level sensor Special purpose vehicles

EE-SX770/771/772/870/871/872(A/P/R)

Triple Beam Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in

Leveling Feet, Base Plates and Casters

INSTALLATION INSTRUCTION RRU DOUBLE LIGHT POLE MOUNT

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800

Demagnetizing. Clamping Chucks. Clamping Plates. Lifting Magnets. Holding Magnets. Demagnetizing. Units. Control Electronics. Non-Ferrous Separators

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Instruction Guide 4A90L

Triple Beam Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

XXXX e. X d.. X X X a

Ultraminiature Photoelectric Switches with Self-contained Amplifier

ASSEMBLY AND ADJUSTMENT

AC AC AC

INVENT3D Printer Kit Disassembly Instructions

WELDING POSITIONER PARTS BREAKDOWN DRAWING GP-200

Vert-X 22E - 24V / 4-20mA. Applications Wind vanes Valve control Level sensor Special purpose vehicles

Transcription:

B 6,5 3,5 4 44 33,5 13 4 00 Flat design on-contacting principle 1 Reed contact ctuating distance up to 60 mm depending on actuating magnet and version ctuating surface marked by protrusion Pre-wired cable available, cable length 1 m Protection class IP 67 tandards: IEC/E 6047-5-1 Protection class: IP 67 to E 6052 Termination: cable LiYY 2 x 0.25 mm 2, length 1 m witching voltage: max. 250 VC witching current: max. 0.5 max. V, W Dielectric strength: > 450 VC (50 Hz) witching time Close : max. 2 ms witching time Open : max. 0.07 ms max. 0.5 ms mbient temperature: 25 C + 75 ºC 5 million operations, Resistance to shock: 15 g on sine wave Resistance to vibration: 15 g on sine wave 1 C contact B -01z with - actuating magnet 1 O contact B -z with - actuating magnet B -rz with actuating magnet B -➀z o. Replace Description ➀ 01 1 C contact 1 O contact r 0, 0, 0,7 0,6 0,4 0,3 0,2 0,1 24 60 0 150 220 250 V 2-72

B 5 16,5 35 20 40 2 14 3 0,7 7,5 14 00 12 7,5 on-contacting principle Mounting with clamping feet and screw clamp Reed-contact to clip-in, on-location assembly djustment by loosening the central mounting screw ctuating distance up to 40 mm depending on actuating magnet and version Two individual wires LiYY 0.75 mm 2 Protection class IP 40 tandards: IEC/E 6047-5-1 Protection class: IP 40 to E 6052 Termination: 2 individual wires LiY 0.75 mm 2, length 1 m witching voltage: max. 60 VC/DC witching current: max. 1 max. 30 V/W Dielectric strength: 400 VDC witching time Close : max. 2 ms witching time Open : max. 0.07 ms max. 0.2 ms mbient temperature: 0 C... + 75 C 500 million operations, Resistance to shock: 60 g on sine wave Resistance to vibration: 60 g on sine wave B 5-rz with actuating magnet B 5-➀-➁ o. Replace Description ➀ r ➁ Mounting with clamping brackets + 2 single wires 131-1 Mounting on C DI rail and 2 single wires without screws 131-2 like above with screws 124-1 Mounting on C DI rail and sheathed cable without screws 124-2 like above with screws 124-3 Mounting with clamping brackets and sheathed cable 0, 0, 0,7 0,6 0,4 0,3 0,2 0,1 0 12 2430 40 50 60 V 2-73

s Magnetic reed switches B 5-5 15,5 30 30 30 30 140 6,5 on-contacting principle For triggering of relays 5 reed-contacts to clip-on Reciprocal switch function through rotating the individual switching elements by 1 LEDs to indicate the switching condition Unused plugs can be filled with blank elements With -pole plug-in connection Protection class IP 30 65 20 tandards: IEC/E 6047-5-1 Protection class: IP 30 to E 6052 Termination: connector, -pole witching conditions indicator: LED ctuating magnet: BP 7 witching voltage: 12 60 VDC witching current: max. 1 max. 30 W Dielectric strength: 400 VDC witching time Close : max. 2 ms witching time Open : max. 0.07 ms mbient temperature: C + 75 ºC 500 million operations, Resistance to shock: 60 g on sine wave Resistance to vibration: 60 g on sine wave ctuating distances: With mounting on ferro material: average max. actuating distance s: 14 mm max. actuating distance under unfavourable conditions s max : 11 mm min. actuating distance s min : 1 mm effective actuating distance s nenn : 6 mm With mounting on non-ferrous material (e.g. plastic rail): actuating distance s: 0 mm effective actuating distance s nenn : 5 mm B 5-5 B 5-5-2031 1 2 3 4 1 2 3 4 5 6 7 5 6 7 B 5-5-➀ o. Replace Description ➀ activation of relays 2031 for connection to control units uitable switch insert B 5-re must be ordered separately! Included in delivery: 2 blank inserts Unit without switch inserts The LED is illuminated when the switch is open. The LED is illuminated when the switch is closed. (ordering suffix -2031) please use the tables on page 2-4. 2-74

B 3 25 13 3,5 3 7 6,5 7 7,5 Flat design on-contacting principle 1 Reed contact ctuating distance up to 60 mm depending on actuating magnet and version ctuating surface and direction of actuation marked by switch symbol Pre-wired cable available, cable length 1 m Protection class IP 67 00 tandards: IEC/E 6047-5-1 Protection class: IP 67 to E 6052 Termination: cable H03VV-F 2 x 0.75 mm 2, length 1 m witching voltage: max. 250 VC witching current: max. 3 max. 120 V/W Dielectric strength: > 600 VC (50 Hz) witching speed: max. 1 m/s witching frequency: max. 300/s for B 3-01z, -z witching time Close : 0.3 ms - 1.5 ms witching time Open : max. 0.5 ms 0.3... 0.6 ms mbient temperature: 25 C + 75 ºC 1 million - 1 billion operations, Resistance to shock: 30 g / 11 ms Resistance to vibration: 30 g / 11 ms Resistance to vibration: 55 Hz, amplitude 1 mm witching point accuracy: ± 0.25 mm, T = constant 1 C contact B 3-01z with - actuating magnet 1 O contact B 3-z with - actuating magnet B 3-rz with actuating magnet 20+-3 20+-3 20+-3 20+-3 5 +- 2 5 +-2 B 3-rz with actuating magnet 5 +- 2 5 +-2 B 3-➀z o. Replace Description ➀ 01 1 C contact 1 O contact r 3,0 2,0 0 24 120 150 220250 V When the switches and actuators come together, the colours must coincide: Red () to red () and green () to green (). This does not apply to the bistable contact. The switch is to be mounted on iron with a non- layer of at least 20 mm. 2-76

B 32 24 26 5 7 4. M4 30 on-contacting principle 1 Reed contact ctuating distance up to 55 mm depending on actuating magnet and version ctuating surface and direction of actuation marked by switch symbol Mounting with two threaded bolts pade connector 4. mm Protection class IP 67 tandards: IEC/E 6047-5-1 Protection class: IP 00... IP 67 to E 6052 Termination: spade connector 4. mm spade connector 6.3 mm (ordering suffix -13) witching voltage: max. 250 VC B 32-11, -11r: max. 220 VC, 150 VDC witching current: max. 3 B 32-11, -11r: max. 1 max. 120 V/W B 32-11, -11r: max. 60 V/W Dielectric strength: > 600 VC (50 Hz) B 32-11, -11r: > 350 VC (50 Hz) witching speed: max. 1 m/s witching frequency: max. 300/s B 32-11, -11r: max. 200/s witching time Close : 0.3 ms - 1.5 ms witching time Open : max. 0.5 ms 0.3... 0.6 ms mbient temperature: 25 C + 0 ºC 1 million - 1 billion operations, Resistance to shock: Resistance to vibration: 15 g on sine wave Resistance to vibration: witching point accuracy: ± 0.25 mm, T = constant 1 O contact B 32-1 C contact B 32-01 1 change-over contact B 32-11 with - actuating magnet B 32-r 1 bistable change-over contact B 32-11r with actuating magnet B 32-r 1 bistable change-over contact B 32-11r with actuating magnet B 32- B 32-01 B 32-11 B 32-r B 32-11r B 32-r B 32-11r 14+- 3 5+- 2 5+- 2 14+- 3 5+- 2 5+- 2 B 32-➀ o. Replace Description ➀ 01 1 C contact 1 O contact 11 1 change-over contact r 11r 1 bistable change-over contact 3,0 2,0 0 24 120 150 220250 V C, O, bistable contact 0, 0, 0,7 0,6 0,4 0,3 0,2 0,1 0 12 2430 40 50 60 V change-over, bistable change-over contact 2-77

B 325 24 26 M4 5 30 on-contacting principle 1 Reed contact ctuating surface and direction of actuation marked by switch symbol Mounting with two threaded bolts pade connector 4. mm Protection class IP 40 tandards: IEC/E 6047-5-1 Protection class: IP 00 IP 40 with insulated plug IP 67 with cable output and additional shielding plate (ordering suffix -127 and -127-2) to E 6052 Termination: spade connector 4. mm (ordering suffix -123) spade connector 6.3 mm (ordering suffix -13) cable output (ordering suffix -127 and -127-2) witching voltage: max. 250 VC witching current: max. 3 max. 120 V Dielectric strength: > 600 VC (50 Hz) witching speed: max. 1 m/s witching frequency: max. 300/s witching time Close : max. 1.5 ms witching time Open : max. 0.5 ms 0.3... 0.6 ms mbient temperature: 25 C + 75 ºC 1 million - 1 billion operations, Resistance to shock: 50 g / 11 ms Resistance to vibration: 30 g on sine wave Resistance to vibration: 55 Hz, amplitude 1 mm witching point accuracy: ± 0.25 mm, T = constant B 325-r with actuating magnet 5+- 0,2 5+-0,2 B 325-r-➀ o. Replace Description ➀ pade terminal 4. mm and 1 shielding plate 123 pade terminal 4. mm and 2 shielding plates 13 pade terminal 6.3 mm and 2 shielding plates 127 Cable output left and 2 shielding plates 127-2 Cable output right and 2 shielding plates 3,0 2,0 0 24 120 150 220250 V 2-7

B 325 special versions M4, 24 Ø 5 26 30 additional shielding plate and cable output left or right (ordering suffix -127 and -127-2) see left 2-7

B 65 24 00 22 3 5 Ø20 M16x 60 ctuation from side Central mounting on-contacting principle ctuating surface and direction of actuation marked by switch symbol Pre-wired cable available, cable length 1 m Protection class IP 67 When the switches and actuators come together, the colours must coincide: Red () to red () and green () to green (). * Ø13 tandards: IEC/E 6047-5-1 tightening force on nut 22 mm /F max. 300 cm Protection class: IP 67 to E 6052 Termination: cable H03VV-F 2 x 0.75 mm 2, length 1 m witching voltage: max. 250 VC witching current: max. 3 max. 120 V/W Dielectric strength: > 600 VC (50 Hz) witching speed: max. 1 m/s witching frequency: max. 300/s witching time Close : 0.3 ms - 1.5 ms witching time Open : max. 0.5 ms 0.3... 0.6 ms max. 3 ms mbient temperature: 25 C + 75 ºC 1 million - 1 billion operations, Resistance to shock: 30 g on sine wave Resistance to vibration: 30 g on sine wave Resistance to vibration: 55 Hz, amplitude 1 mm witching point accuracy: ± 0.25 mm, T = constant 1 O contact B 65-z with - actuating magnet 20 23 +- 1 C contact B 65-01z with - actuating magnet B 65-rz with actuating magnet B 65-rz with actuating magnet +- 3 +-3 20 3 23 +-3 +- 3 +-3 This does not apply to the bistable contact. 15 6 +- 3 6 +-3 B 65-➀z➁ o. Replace Description ➀ 01 1 C contact 1 O contact r ➁ With bias magnet /1 Without bias magnet 3,0 2,0 0 24 120 150 220250 V 2-

B 65/V 24 00 22 3 5 Ø20 M16x 60 ctuation from front Central mounting on-contacting principle ctuating surface and direction of actuation marked by switch symbol Pre-wired cable available, cable length 1 m Protection class IP 67 When the switches and actuators come together, the colours must coincide: Red () to red () and green () to green (). This does not apply to the bistable contact. B 65-➀z/➁V o. Replace Description ➀ 01 1 C contact 1 O contact 11 1 change-over contact r 11r 1 bistable change-over contact ➁ With bias magnet /1 Without bias magnet * Ø13 tandards: IEC/E 6047-5-1 tightening force on nut 22 mm /F max. 300 cm Protection class: IP 67 to E 6052 Termination: cable H03VV-F 2 x 0.75 mm 2, 03VV-F 3 x 0.75 mm 2, length 1 m witching voltage: max. 250 VC B 65-rz/V, -11rz/V: max. 230 VC/DC witching current: max. 3 B 65-rz/V, -11rz/V: max. 1 max. 120 V/W B 65-rz/V, -11rz/V: max. 60 W Dielectric strength: > 600 VC (50 Hz) B 65-rz/V, -11rz/V: > 350 VC (50 Hz) witching speed: max. 1 m/s witching frequency: max. 300/s B 65-rz/V, -11rz/V: max. 200/s witching time Close : 0.3 ms - 1.5 ms witching time Open : max. 0.5 ms 0.3... 0.6 ms max. 3 ms mbient temperature: 25 C + 75 ºC 1 million -, Resistance to shock: 30 g on sine wave B 65-rz/V, -11rz/V: 15 g on sine wave Resistance to vibration: 30 g on sine wave B 65-rz/V, -11rz/V: 15 g on sine wave Resistance to vibration: 55 Hz, amplitude 1 mm witching point accuracy: ± 0.25 mm, T = constant 0, 0, 0,7 0,6 0,4 0,3 0,2 0,1 24 60 1 150 220 V change-over, bistable change-over contact 1 O contact B 65-z/V with actuating magnet 1 C contact B 65-01z/V with actuating magnet 1 change-over contact B 65-11z/V with actuating magnet B 65-rz/V with - actuating magnet 1 bistable change-over contact B 65-11rz/V with - actuating magnet 3,0 2,0 0 24 120 150 220250 V C, O, bistable contact 2-1

B 20 16 2 M 16x 7,5 6,5 6,5 60 75 30 1 4 25 47 52 luminium enlosure on-contacting principle 1 Reed contact Particularly resistant to vibration vailable for actuation from front or side ctuating distance up to 50 mm depending on actuating magnet and version crew terminal Protection class IP 67 When the switches and actuators come together, the colours must coincide: Red () to red () and green () to green (). tandards: IEC/E 6047-5-1 l i12 die-casting, chromated and painted Protection class: IP 67 to E 6052 Termination: screw terminals witching voltage: max. 250 VC witching current: max. 3 max. 120 V/W Dielectric strength: > 600 VC (50 Hz) witching speed: max. 1 m/s witching frequency: max. 300/s witching time Close : 0.3 ms - 1.5 ms witching time Open : max. 0.5 ms 0.3... 0.6 ms mbient temperature: 25 C + 0 ºC 1 million - 1 billion operations, Resistance to vibration: 50 g on sine wave witching point accuracy: ± 0.25 mm, T = constant 1 O contact B 20-z 1 C contact B 20-01z with - actuating magnet B 20-rz with actuating magnet B 20-rz with actuating magnet 17 +- 3 17 + - 3 6 +- 3 6 +- 3 6 +- 3 6 +- 3 B 20-➀z o. Replace Description ➀ 01 1 C contact 02 2 C contacts 1 O contact 20 2 O contacts 11 1 change-over contact r 2r 2 bistable contacts 11r 1 bistable change-over contact 3,0 2,0 0 24 120 150 220250 V 2-2

B 75 5,5 4,2 55 30 35 55,5 Float switch on-contacting principle 1 Reed contact vailable with plug-in connetor or pre-wired cable Protection class IP 6 Depending on how the floater is assembled, either a O contact or a C contact is possible. The switching function is reversed accordingly, if the floater in a change-over contact element is turned upside-down. The operating points listed, apply for water. 34 tandards: IEC/E 6047-5-1 Protection class: IP 6 plug connection IP 65 IP 67 cable connection (ordering suffix -131) to E 6052 Termination: witching voltage: max. 220 VC witching current: max. 1 max. 60 V/W Hysteresis: ca. 3 mm Dielectric strength: > 600 VC (50 Hz) B 75-11y: > 350 VC (50 Hz) 0.3... 0.6 ms B 75-11y: max. 0.2/0.5 ms mbient temperature: 25 C + ºC 1 million - 1 billion operations, 1 O contact B 75-y 47+- 3 45+- 3 47+ - 3 1 C contact B 75-01y 1 change-over contact B 75-11y B 75-➀y-➁ o. Replace Description ➀ 01 1 C contact 1 O contact 11 1 change-over contact ➁ Plug-in connector to DI 43650 131 Pre-wired cable 3,0 2,0 0 24 120 150 220250 V C, O, bistable contact 0, 0, 0,7 0,6 0,4 0,3 0,2 0,1 24 60 1 150 220 V change-over, bistable change-over contact 2-3

ystem components ystem components ystem components 1, 0 ø3,3 ø15 0 5 12 BP 6 0 ø ø14 BP 7 0 7,7 ø 3,3 ø 11, 17 BP 25 51 ø ø4,3 ø 0 65 15 27 ø 4,3 ø 2 25 51 () 65 15 27 BP 15 BP 20 / BP 20 () 0 ø 4,3 ø20 24 5 4 23 7,5 34 4 BP 15/2 BP 31 0 ø34 5,3 24 5 4 23 7,5 34 4 BP 34 BP 31 / BP 31 15 BP BP 20 BP 11 ctuating magnet Unenclosed, - BP 6 Unenclosed, - BP 7 Unenclosed, - BP Unenclosed, - BP ctuating magnet enclosure, - BP 15 Unenclosed, - BP 15/2 enclosure, - BP 34 metal enclosure, - BP 20 ctuating magnet metal enclosure l, BP 20 metal enclosure l, BP 20 enclosure, - BP 31 enclosure, BP 31 enclosure, BP 31 metal enclosure l, - BP 11 2-4

ca. 00 Magnetic reed switches ystem components ystem components ystem components 40 3 12 15 65 40 3 12 7 15 25 20 15 BP 11 / BP 11 2x BP 11 / 2x BP 11 BP 12 130 0 50 6,5 65 1 130 30 65 2x BP 12 / 2x BP 12 7,5 13 BP 21 35 BP 21 / BP 21 25 35 70 2x BP 22 / 2x BP 22 55 43 2,5 1 74 62 ø 4,3 5 66 160 145 140 BP 22 7,5 25 BP 22 / BP 22 35 7 25 25 ø 6,5 BP 12 / BP 12 2x BP 21 / 2x BP 21 BE 20 16,5 ctuating magnet metal enclosure l, BP 11 metal enclosure l, BP 11 metal enclosure l, 2x 2x BP 11 metal enclosure l, 2x 2x BP 11 metal enclosure l, - BP 12 metal enclosure l, BP 12 metal enclosure l, BP 12 ctuating magnet metal enclosure l, 2x 2x BP 12 metal enclosure l, 2x 2x BP 12 metal enclosure l, - BP 21 metal enclosure l, BP 21 metal enclosure l, BP 21 metal enclosure l, 2x 2x BP 21 metal enclosure l, 2x 2x BP 21 ctuating magnet metal enclosure Zn, - BP 22 metal enclosure Zn, BP 22 metal enclosure Zn, BP 22 metal enclosure Zn, 2x 2x BP 22 metal enclosure Zn, 2x 2x BP 22 Electromagnet, enclosure BE 20 2-5

pacer B 31/33,5 ø5 13 7 3,5 7 25 To mount the safety sensor and actuator on ferro material Holder H1/1 ø13 34 17,5 3 5,5 2 Terminal mounting H 15 15 ø15 M5 30 17 33 46 For B 65 Material: Compensating coil K 1 ca. 000 11 36 30 2,5 M20 27 3 3 7,5 For B 65 Metal holder with 2 elastic bearings Provides high resistance to vibration Dimension X = 23 mm For cable lengths up to 0 m Cable H07V-K 1 mm 2, cable length 1 m The bucking coil is to be wired in series with the reed contact Holder H2 Compensating coil K 2 ø13 16 27 ca. 000 11 23 5 22 4 11 M20 2,5 27 12 7 45 For B 65 Metal holder with rubber washer Dimension X = 36 mm For cable lengths up to 200 m or 2 x 0 m Cable H07V-K 1 mm 2, cable length 1 m The bucking coil is to be wired in series with the reed contact 2-6