Test Report : ITB-010

Similar documents
Test Report. Applicant : ICP DAS Co., LTD Address : No. 111, Kuang-Fu N. Rd., Hsin-Chu Industrial Park, Hukou Shiang, HSINCHU 303, Taiwan

Test Report. Applicant ICP DAS CO., LTD. Address No. 111, Kuangfu N. Rd., Hukou Shiang, Hsinchu, Taiwan 303, R.O.C.

Test Report. Product Name: Cable Modem Model No.: BEFCMU10 ver.3 FCC ID. : Q87-BEFCMU10V3

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

CERTIFICATE. Issued Date: Sep. 21, 2007 Report No.: R-ITCEP07V04. : HMLCD19L, HMLCD19xxxxx (X=0~9, A~Z) : Honeywell Video Systems

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

Test Report. Product Name : PC2PC-Bluetooth Model No. : MS Date of Receipt : Apr. 22, Date of Test : May 09, Report No.

Test Report. Product Name : MEGABOOK Model No. : MS-1010, M620

CE EMC Test Certification

CE TEST CERTIFICATION

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

CE TEST CERTIFICATION

Test Report. Product Name : Access Point Model No.: MS-6809 FCC ID.: I4L-MS6809

Report No R-RFCEP02V01. Test Report. Model No. MS-6638, AE 1900 Transmitter Module. MSI / MS-6890

Report No R-RFCEP02V01. Test Report. Model No. MS-N012, U110, U115 Transmitter Module. MSI / MS-6890

Report No R-RFCEP02V01-A. Test Report. Model No. MS-1223, MS-1331 Transmitter Module. MSI / MS Date of Receipt Apr.

Test Report. Applicant MICRO-STAR INT L CO., LTD Address No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan. Date of Receipt Dec.

Test Report. Product Name : IPC Model No.

Report No R-RFCEP02V01. Test Report. Model No. MS-163C Transmitter Module. Intel / 4965AGN. Date of Receipt July 03, 2007

Report No R-RFCEP02V01-A. Test Report. Product Name Notebook Model No. MS-1731 Transmitter Module MSI / MS-6894

Report No R-RFCEP02V01. Test Report. Model No. MS-N033,U123 Transmitter Module. MSI / MS-6894

Report No R-RFCEP02V01-A. Test Report. Model No. MS-1227, MS-1333 Transmitter Module. MSI / MS Date of Receipt Jul.

Report No. 074L001-RFCEP02V01. Test Report. Model No. MS-1221, PR200 Transmitter Module. Intel / 4965AGN. Date of Receipt Mar.

Report No. 09C136R-RFCEP76V01-B. Test Report. Product Name Notebook Model No. MS-1681, CR620, A6200 Transmitter Module MSI / MS-3870

Test Report. Product Name : b P3 Wireless LAN PCMCIA Card Model No. : WN-110 FCC ID : QDWWN110

Report No R-RFCEP02V01-B. Test Report. Model No. MS-1227, MS-1333 Transmitter Module. Atheros / AR5BXB63

Report No R-RFCEP02V01-A. Test Report. Model No. MS-1452, EX460, EX461 Transmitter Module. MSI / MS-6891

CERTIFICATE. Issued Date: Apr. 02, 2009 Report No.: R-ITUSP01V01

Test Report. : 09A255R-ITCEP28V01 Report Version : V1.0

Test Report. Model No. MS-1049, MS-1049B, L710, 7100U Series (with MS-6833)

Report No R-RFCEP76V01. Test Report

Test Report MS-1651, GX620, GT620. MICRO-STAR INT L Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

CERTIFICATE. Issued Date: Aug. 22, 2008 Report No.: R-ITCEP07V03 This is to certify that the following designated product

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

Report No. 062L020-RF-CE-P02V01-1. Test Report. MS-1034, MS-1034B, MS-10341, MS-10341B, MS-10342, MS-10342B Transmitter Module.

Test Report. Applicant MICRO-STAR INT L CO., LTD No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan. Date of Receipt Mar.

Test Report. Applicant : Moxa Networking Co., Ltd. Address : Fl.8, No.6, Alley 6,Lane 235, Pao-Chiao Rd. Shing Tien City, Taiwan, R.O.C.

2620 Modular Measurement and Control System

Report No R-RFCEP02V01-A. Test Report. Model No. MS-1674, EX620 Transmitter Module. MSI / MS-6890

Report No R-RFCEP02V01-A. Test Report MS-1644, PR621, PR621X

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

ELECTRONICS TESTING CENTER(ETC), TAIWAN

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

Report No R-RFCEP02V01. Test Report. Model No. MS-163A,GX600,GX600X Transmitter Module. Intel / 4965AGN

Report No R-RFCEP02V01. Test Report. Date of Receipt Apr. 28, Issued Date May. 23, 2008

Test Report. MS-1031,M640,6400,6400 series. Applicant MICRO-STAR INT L CO., LTD No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

Report No. 071L112-RFCEP02V01-A. Test Report. Model No. MS-1719 Transmitter Module. Intel / 4965AGN. Date of Receipt Jan. 23, 2007

Report No. 062L020-RF-CE-P02V01-2. Test Report. Model No. MS-1613 Transmitter Module. Intel / WM3945ABG. Date of Receipt Dec.

EMC TEST REPORT. according to

EMC VERIFICATION SUMMARY Report No.: SZHH

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

1 SUMMARY OF STANDARDS AND RESULTS

Test Report. Model No. MS-6421, Media Live Transmitter Module. MSI / MS-6874

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

CE EMC CERTIFICATION

APPENDIX A. GENERAL DESCRIPTION OF EQUIPMENT UNDER TEST

Report No R-RFCEP76V01. Test Report

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

Report No R-RFCEP76V01. Test Report

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

CONFORMANCE TEST REPORT FOR EN /-6

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

Report No R-RFCEP02V01. Test Report MS-1644, PR621, PR621X

Report No R-RFCEP76V01-A. Test Report

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

Report No.: 063L107-RF-CE-P14V02-2. Test Report. MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

CE EMC Test Certification

CERTIFICATE. Issued Date: July 27, 2007 Report No.: 076L030-ITCEP07V03

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

CERTIFICATE. Issued Date: May 21, 2008 Report No.: R-ITUSP02V01

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

TEST REPORT... 1 CONTENT...

9. Electrostatic Discharge Immunity Test (ESD)

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

CERTIFICATE EN 55022: 2006 EN 55024: 1998+A1: 2001+A2: EN :2006 IEC Edition 1.2: (Level 3)

Test Report. Applicant Address. : MICRO-STAR INT L Co., LTD. : No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

Report No R-RFCEP76V01. Test Report MS-6681, DC520, DE520

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

C E R T I F I C A T I O N

FCC 47 CFR PART 15 SUBPART B

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

CERTIFICATE EN 55022: 1998+A1: 2000+A2: 2003 EN 55024: 1998+A1: 2001+A2: EN : 2000 IEC Edition 1.

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

Report No R-RFCEP02V01. Test Report. Date of Receipt Jun. 04, Issued Date Jul. 21, 2008

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

Transcription:

Test Report Product Name : Digital Ink Pad Model No. : ITB-010 Applicant : WALTOP International Corp. Address : 6F, No. 19-1 Industry E. Rd. IV, Hsinchu Science Park, Hsin-Chu 30077, Taiwan, R.O.C. Date of Receipt : 2005/07/15 Issued Date : 2005/07/20 Report No. : 057H059E The test results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation. Page: 1 of 74

Declaration of Conformity The following products is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility Directive (89/336/EEC). The listed standard as below were applied: The following Equipment: Product Trade Name Model Number : Digital Ink Pad : WALTOP : ITB-010 This product is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility Directive (89/336/EEC).For the evaluation regarding EMC, the following standards were applied: RFI Emission: EN 55022:1998+A1: 2000+A2: 2003 Class B : Emission standard EN 61000-3-2:2000 Class A : Limits for harmonic current emission EN 61000-3-3:1995+A1: 2001 : Limitation of voltage fluctuation and flicker in Immunity: low-voltage supply system EN 55024:1998+A1: 2001+A2: 2003 : Immunity standard The following importer/manufacturer is responsible for this declaration: Company Name : Company Address : Telephone : Facsimile : Person is responsible for marking this declaration: Name (Full Name) Position/ Title Date Legal Signature

EMC/Safety Test Laboratory Accredited by DNV, TUV, Nemko and NVLAP QTK No.: 057H059E Statement of Conformity The certifies that the following designated product Product : Digital Ink Pad Trade Name : WALTOP Model Number : ITB-010 Company Name : WALTOP International Corp. This product is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility Directive (89/336/EEC).For the evaluation regarding EMC, the following standards were applied: RFI Emission: EN 55022:1998+A1: 2000+A2: 2003 Class B : Emission standard EN 61000-3-2:2000 Class A : Limits for harmonic current emission EN 61000-3-3:1995+A1: 2001 : Limitation of voltage fluctuation and flicker in low-voltage supply system Immunity: EN 55024:1998+A1: 2001+A2: 2003 : Immunity standard TEST LABORATORY Bob Fang/Director The verification is based on a single evaluation of one sample of above-mentioned products. It does not imply an assessment of the whole production and does not permit the use of the test lab. Logo. QuieTek Corporation / No.75-1, Wang-Yeh Valley, Yung-Hsing, Chiung-Lin, Hsin-Chu County, Taiwan, R.O.C. Tel: 886-3-5928858, Fax: 886-3-5928859, E-mail: service@quietek.com

Test Report Certification Issued Date : 2005/07/20 Report No. : 057H059E Product Name : Digital Ink Pad Applicant : WALTOP International Corp. Address : 6F, No. 19-1 Industry E. Rd. IV, Hsinchu Science Park, Hsin-Chu 30077, Taiwan, R.O.C. Manufacturer : WALTOP International Corp. Model No. : ITB-010 Rated Voltage : AC 230 V / 50 Hz EUT Voltage : DC 5V Trade Name : WALTOP Applicable Standard : EN 55022: 1998+A1: 2000+ A2: 2003, AS/NZS CISPR 22: 2004 EN 61000-3-2: 2000, EN 61000-3-3: 1995+A1: 2001 EN 55024: 1998+A1: 2001+ A2: 2003 Classification : B Test Result : Complied The test results relate only to the samples tested. The test report shall not be reproduced except in full without the written approval of QuieTek Corporation. Documented By : Tested By : (Sandy Chuang) Approved By : (Winson Wen) (Bob Fang) Page: 2 of 74

TABLE OF CONTENTS Description Page 1. General Information...6 1.1. EUT Description...6 1.2. Test Mode...7 1.3. Tested System Details...8 1.4. Configuration of tested System...9 1.5. EUT Exercise Software...10 1.6. Test Facility...11 2. Conducted Emission...13 2.1. Test Equipment...13 2.2. Test Setup...13 2.3. Limits...14 2.4. Test Procedure...14 2.5. Test Specification...14 2.6. Test Result...15 2.7. Test Photo...17 3. Radiated Emission...18 3.1. Test Equipment...18 3.2. Test Setup...18 3.3. Limits...19 3.4. Test Procedure...19 3.5. Test Specification...19 3.6. Test Result...20 3.7. Test Photo...22 4. Power Harmonics...23 4.1. Test Equipment...23 4.2. Test Setup...23 4.3. Limits...24 4.4. Test Procedure...25 4.5. Test Specification...25 4.6. Test Result...26 4.7. Test Photo...27 5. Voltage Fluctuation and Flicker...28 5.1. Test Equipment...28 5.2. Test Setup...28 5.3. Limits...29 5.4. Test Procedure...29 5.5. Test Specification...29 5.6. Test Result...30 5.7. Test Photo...31 6. Electrostatic Discharge (ESD)...32 6.1. Test Equipment...32 6.2. Test Setup...32 6.3. Limits...33 6.4. Test Procedure...33 Page: 3 of 74

6.5. Test Specification...33 6.6. Test Result...34 6.7. Test Photo...35 7. Radiated Susceptibility (RS)...36 7.1. Test Equipment...36 7.2. Test Setup...36 7.3. Limits...37 7.4. Test Procedure...37 7.5. Test Specification...37 7.6. Test Result...38 7.7. Test Photo...39 8. Electrical Fast Transient/Burst (EFT/B)...40 8.1. Test Equipment...40 8.2. Test Setup...40 8.3. Limits...41 8.4. Test Procedure...41 8.5. Test Specification...41 8.6. Test Result...42 8.7. Test Photo...43 9. Surge...44 9.1. Test Equipment...44 9.2. Test Setup...44 9.3. Limits...45 9.4. Test Procedure...45 9.5. Test Specification...45 9.6. Test Result...46 9.7. Test Photo...47 10. Conducted Susceptibility (CS)...48 10.1. Test Equipment...48 10.2. Test Setup...48 10.3. Limits...49 10.4. Test Procedure...49 10.5. Test Specification...49 10.6. Test Result...50 10.7. Test Photo...51 11. Power Frequency Magnetic Field...52 11.1. Test Equipment...52 11.2. Test Setup...52 11.3. Limits...53 11.4. Test Procedure...53 11.5. Test Specification...53 11.6. Test Photo...55 12. Voltage Dips and Interruption...56 12.1. Test Equipment...56 12.2. Test Setup...56 12.3. Limits...57 12.4. Test Procedure...57 Page: 4 of 74

12.5. Test Specification...57 12.6. Test Result...58 12.7. Test Photo...59 Attachement...60 EUT Photograph...60 Reference : Laboratory of License Page: 5 of 74

1. General Information 1.1. EUT Description Product Name Trade Name Model No. Digital Ink Pad WALTOP ITB-010 Component USB Cable Shielded, 1.5m, two ferrite cores bonded. Note: 1. This EUT is a Digital Ink Pad. Page: 6 of 74

1.2. Test Mode QuieTek has verified the construction and function in typical operation. All the test modes were carried out with the EUT in normal operation, which was shown in this test report and defined as: Pre-Test Mode EMC Final Test Mode EMI EMS Mode 1: Normal Operation Mode 1: Normal Operation Mode 1: Normal Operation Page: 7 of 74

1.3. Tested System Details The types for all equipments, plus descriptions of all cables used in the tested system (including inserted cards) are: Product Manufacturer Model No. Serial No. Power Cord 1 PC HP DL109A#AB0 SGH3300897 Non-shielded, 1.8m 2 Monitor SONY PVM-14M2U 2018559 Non-Shielded, 1.8m 3 Keyboard HP SK-2502C M020303883 -- 4 Mouse IBM M-SAU-IBM6 23-022676 -- 5 Portable Hard DISK Top Disk Enterprise Me-910 220957 -- 6 Portable Hard DISK Top Disk Enterprise Me-910 220951 -- 7 USB 2.0 Flash Ridata PEN000-DP065-37 N/A -- Memory 8 USB 2.0 Flash Ridata PEN000-DP065-37 N/A -- Memory 9 USB 2.0 Flash Memory Ridata PEN000-DP065-37 N/A -- 10 Modem ACEEX DM-1414 980033034 Non-Shielded, 1.6m 11 Printer HP C8952D CN277180B6 Non-Shielded, 1.8m Page: 8 of 74

1.4. Configuration of tested System Connection Diagram A J K Monitor (2) PC (1) H EUT Printer (11) G D E F L Portable Hard DISK (5) Portable Hard DISK (6) USB 2.0 Flash Memory (7) USB 2.0 Flash Memory (8) USB 2.0 Flash Memory (9) I B C Keyboard (3) Mouse (4) Modem (10) Internet Signal Cable Type Signal cable Description A VGA Cable Shielded, 1.6m B Keyboard Cable Shielded, 1.8m C Mouse Cable Shielded, 1.8m D USB Cable Shielded, 1.2m E USB Cable Shielded, 1.2m F USB Cable Shielded, 1.2m G USB Cable Shielded, 1.2m H USB Cable Shielded, 1.2m I Modem Cable Shielded, 1.5m J Printer Cable Shielded, 1.2m K USB Cable Shielded, 1.5m, two ferrite cores bonded L LAN Cable Non-Shielded, 3.0m Page: 9 of 74

1.5. EUT Exercise Software 1 Setup the EUT and simulators as shown on section 1.4. 2 Turn on the power of all equipments. 3 Boot the PC from Hard Disk. 4 EUT (Digital Ink Pad) writes data into PC. 5 The personal computer s monitor will show the transmitting and receiving characteristics when the communication is success fully linked. 6 Repeat the above procedure (4) to (5). Page: 10 of 74

1.6. Test Facility Ambient conditions in the laboratory: Items Test Item Required (IEC 68-1) Actual Temperature ( C) EN55022 CE 15-35 20 Humidity (%RH) 25-75 50 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) EN55022 RE 15-35 20 Humidity (%RH) 25-75 65 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) EN61000-3-2 15-35 20 Humidity (%RH) 25-75 50 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) EN61000-3-3 15-35 20 Humidity (%RH) 25-75 50 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) IEC 61000-4-4 15-35 22 Humidity (%RH) 25-75 48 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) IEC61000-4-11 15-35 22 Humidity (%RH) 25-75 48 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) IEC61000-4-2 15-35 22 Humidity (%RH) 30-60 48 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) IEC61000-4-3 15-35 22 Humidity (%RH) 25-75 48 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) IEC61000-4-5 15-35 22 Humidity (%RH) 10-75 48 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) IEC61000-4-6 15-35 22 Humidity (%RH) 25-75 48 Barometric pressure (mbar) 860-1060 950-1000 Temperature ( C) IEC61000-4-8 15-35 22 Humidity (%RH) 25-75 48 Barometric pressure (mbar) 860-1060 950-1000 Page: 11 of 74

Site Description: Accredited by NVLAP NVLAP Lab Code: 200347-0 Effective through: September 30, 2005 Accredited by CNLA Accreditation Number: 1313 Effective through: September 27, 2007 February 23, 1999 Accreditation on DNV Statement No. : 413-99-LAB11 1313 ILAC MRA June 15, 2004 Accreditation on TUV Rheinland Certificate No.: 10011438-2-2004 October 08, 2003 Accreditation on Nemko Certificate No.: ELA 165 Site Name: Quietek Corporation Site Address: No.75-1, Wang-Yeh Valley, Yung-Hsing, Chiung-Lin, Hsin-Chu County, Taiwan, R.O.C. TEL : 886-3-5928858 / FAX : 886-3-5928859 E-Mail : service@quietek.com Page: 12 of 74

2. Conducted Emission 2.1. Test Equipment The following test equipment are used during the test: Item Equipment Manufacturer Model No. / Serial No. Last Cal. Remark 1 Test Receiver R & S ESCS 30/825442/018 Sep., 2004 2 Artificial Mains Network R & S ENV4200/848411/10 Feb., 2005 Peripherals 3 LISN R & S ESH3-Z5/825562/002 Feb., 2005 EUT 4 Pulse Limiter R & S ESH3-Z2/357.8810.52 Feb., 2005 5 No.2 Shielded Room N/A Note: All equipment upon which need to calibrated are with calibration period of 1 year. 2.2. Test Setup Page: 13 of 74

2.3. Limits Frequency EN 55022 Limits (dbuv) Class A Class B MHz QP AV QP AV 0.15-0.50 79 66 66-56 56-46 0.50-5.0 73 60 56 46 5.0-30 73 60 60 50 Remarks : In the above table, the tighter limit applies at the band edges. 2.4. Test Procedure The EUT and simulators are connected to the main power through a line impedance stabilization network (L.I.S.N.). This provides a 50 ohm /50uH coupling impedance for the measuring equipment. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test setup and photographs.) Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed according to EN 55022: 1998+A1: 2000+A2: 2003 on conducted measurement. Conducted emissions were invested over the frequency range from 0.15MHz to 30MHz using a receiver bandwidth of 9kHz. 2.5. Test Specification According to EN 55022: 1998+A1: 2000+A2: 2003 Page: 14 of 74

2.6. Test Result Product Digital Ink Pad Test Item Conducted Emission Test Mode Mode 1: Normal Operation Date of Test 2005/07/14 Test Site No.2 Shielded Room Frequency Cable LISN Reading Emission Limits Loss Factor Level Level MHz db db dbuv dbuv dbuv ================================================================== Line 1 Quasi-Peak 0.181 0.10 0.10 28.33 28.53 64.43 0.451 0.10 0.10 26.19 26.39 56.86 4.173 0.15 0.21 30.65 31.01 56.00 11.908 0.26 0.53 43.83 44.61 60.00 * 15.896 0.31 0.72 49.33 50.36 60.00 23.849 0.42 0.96 43.72 45.10 60.00 Average 0.181 0.10 0.10 24.70 24.90 54.44 0.451 0.10 0.10 14.90 15.10 46.86 4.173 0.15 0.21 22.70 23.06 46.00 11.908 0.26 0.53 35.10 35.88 50.00 * 15.896 0.31 0.72 39.90 40.93 50.00 23.849 0.42 0.96 33.30 34.68 50.00 Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. *, means this data is the worst emission level. 3. Emission Level = Reading Level + LISN Factor + Cable Loss. Page: 15 of 74

Product Digital Ink Pad Test Item Conducted Emission Test Mode Mode 1: Normal Operation Date of Test 2005/07/14 Test Site No.2 Shielded Room Frequency Cable LISN Reading Emission Limits Loss Factor Level Level MHz db db dbuv dbuv dbuv ================================================================== Line 2 Quasi-Peak 0.198 0.10 0.10 39.31 39.51 63.68 0.298 0.10 0.10 32.71 32.91 60.29 2.978 0.14 0.16 30.93 31.23 56.00 11.931 0.26 0.38 44.13 44.77 60.00 * 15.878 0.31 0.52 49.27 50.10 60.00 23.834 0.42 0.76 43.78 44.96 60.00 Average 0.198 0.10 0.10 38.30 38.50 53.69 0.298 0.10 0.10 31.30 31.50 50.30 2.978 0.14 0.16 28.40 28.70 46.00 11.931 0.26 0.38 33.70 34.34 50.00 * 15.878 0.31 0.52 38.60 39.43 50.00 23.834 0.42 0.76 32.90 34.08 50.00 Note: 1. All Reading Levels are Quasi-Peak and Average value. 2. *, means this data is the worst emission level. 3. Emission Level = Reading Level + LISN Factor + Cable Loss. Page: 16 of 74

2.7. Test Photo Test Mode : Mode 1: Normal Operation Description: Front View of Conducted Emission Test Setup Test Mode : Mode 1: Normal Operation Description: Back View of Conducted Emission Test Setup Page: 17 of 74

3. Radiated Emission 3.1. Test Equipment The following test equipment are used during the test: Item Equipment Manufacturer Model No. / Serial No. Last Cal. 1 X Test Receiver R & S ESCS 30 / 836858/023 Jan., 2005 2 X Spectrum Analyzer Advantest R3261C / 81720471 N/A 3 X Pre-Amplifier QuieTek QTK-AMP / AMP1 N/A 4 X Bilog Antenna Chase CBL6112B / 2708 Sep., 2004 5 No.2 OATS Sep., 2004 Note: 1. All equipments that need to calibrate are with calibration period of 1 year. 2. Mark X test instruments are used to measure the final test results. 3.2. Test Setup Page: 18 of 74

3.3. Limits EN 55022 Limits (dbuv/m) Frequency MHz Class A Distance dbuv/m (m) Class B Distance dbuv/m (m) 30 230 10 40 10 30 230 1000 10 47 10 37 Remark: 1. The tighter limit shall apply at the edge between two frequency bands. 2. Distance refers to the distance in meters between the measuring instrument antenna and the closed point of any part of the device or system. 3. RF Voltage (dbuv/m) = 20 log RF Voltage (uv/m) 3.4. Test Procedure The EUT and its simulators are placed on a turn table which is 0.8 meter above ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT was positioned such that the distance from antenna to the EUT was 10 meters. The antenna can move up and down between 1 meter and 4 meters to find out the maximum emission level. All cable leaving the table-top EUT for a connection outsidethe test site (for example, mains cable, telephone lines, connections to auxiliary equipment located outside the test area) shall be fitted with ferrite clamps placed on the floor at the point where the cable reached the floor. Both horizontal and vertical polarization of the antenna are set on measurement. In order to find the maximum emission, all of the interface cables must be manipulated according to EN 55022: 1998+A1: 2000+A2: 2003 on radiated measurement. Radiated emissions were invested over the frequency range from 30MHz to1ghz using a receiver bandwidth of 120kHz. Radiated was performed at an antenna to EUT distance of 10 meters. 3.5. Test Specification According to EN 55022: 1998+A1: 2000+A2: 2003 Page: 19 of 74

3.6. Test Result Product Digital Ink Pad Test Item Radiated Emission Test Mode Mode 1: Normal Operation Date of Test 2005/07/14 Test Site No.2 OATS Frequency Cable Probe PreAMP Reading Emission Margin Limit Loss Factor Level Level MHz db db/m db dbuv dbuv/m db dbuv/m ========================================================== Horizontal: 81.000 2.40 8.49 0.00 6.22 17.11 12.89 30.00 120.000 3.00 12.02 0.00 4.20 19.22 10.78 30.00 160.000 3.60 10.32 0.00 1.30 15.22 14.78 30.00 192.000 3.80 9.00 0.00 0.30 13.10 16.90 30.00 235.250 4.20 10.85 0.00 5.44 20.49 16.51 37.00 255.900 4.40 13.29 0.00 1.65 19.34 17.66 37.00 * 540.000 7.00 18.87 0.00 0.45 26.32 10.68 37.00 Note: 1. All Reading Levels are Quasi-Peak value. 2. *, means this data is the worst emission level. 3. Emission Level = Reading Level + Probe Factor + Cable Loss. Page: 20 of 74

Product Digital Ink Pad Test Item Radiated Emission Test Mode Mode 1: Normal Operation Date of Test 2005/07/14 Test Site No.2 OATS Frequency Cable Probe PreAMP Reading Emission Margin Limit Loss Factor Level Level MHz db db/m db dbuv dbuv/m db dbuv/m ========================================================== Vertical: 81.000 2.40 7.43 0.00 8.17 18.00 12.00 30.00 120.600 3.00 11.66 0.00 1.33 15.99 14.01 30.00 166.625 3.60 9.67 0.00 1.69 14.96 15.04 30.00 233.500 4.40 10.51 0.00 0.43 15.34 21.66 37.00 288.000 4.80 13.17 0.00 1.78 19.75 17.25 37.00 317.800 5.20 14.31 0.00 0.81 20.32 16.68 37.00 * 540.000 7.00 18.25 0.00 0.43 25.68 11.32 37.00 Note: 1. All Reading Levels are Quasi-Peak value. 2. *, means this data is the worst emission level. 3. Emission Level = Reading Level + Probe Factor + Cable Loss. Page: 21 of 74

3.7. Test Photo Test Mode : Mode 1: Normal Operation Description: Front View of Radiated Emission Test Setup Test Mode : Mode 1: Normal Operation Description: Back View of Radiated Emission Test Setup Page: 22 of 74

4. Power Harmonics 4.1. Test Equipment The following test equipment are used during the test: Item Equipment Manufacturer Model No. / Serial No. Last Cal. 1 EMC Emission Tester EMC PARTNER AG Switzerland HARMONIC-1000-1P/ 109 Mar., 2005 2 No.1 Shielded Room N/A Note: All equipment upon which need to calibrated are with calibration period of 1 year. 4.2. Test Setup Page: 23 of 74

4.3. Limits Limits of Class A Harmonics Currents Harmonics Harmonics Maximum Permissible Maximum Permissible Order Order harmonic current harmonic current n A n A Odd harmonics Even harmonics 3 2.30 2 1.08 5 1.14 4 0.43 7 0.77 6 0.30 9 0.40 8 n 40 0.23 * 8/n 11 0.33 13 0.21 15 n 39 0.15 * 15/n Limits of Class B Harmonics Currents For Class B equipment, the harmonic of the input current shall not exceed the maximum permissible values given in table that is the limit of Class A multiplied by a factor of 1.5. Limits of Class C Harmonics Currents Harmonics Order Maximum Permissible harmonic current Expressed as a percentage of the input current at the fundamental frequency n % 2 2 3 30.λ * 5 10 7 7 9 5 11 n 39 (odd harmonics only) 3 *λ is the circuit power factor Page: 24 of 74

Limits of Class D Harmonics Currents Harmonics Order n Maximum Permissible harmonic current per watt ma/w Maximum Permissible harmonic current A 3 3.4 2.30 5 1.9 1.14 7 1.0 0.77 9 0.5 0.40 11 0.35 0.33 11 n 39 (odd harmonics only) 3.85/n See limit of Class A 4.4. Test Procedure The EUT is supplied in series with power analyzer from a power source having the same normal voltage and frequency as the rated supply voltage and the equipment under test. And the rated voltage at the supply voltage of EUT of 0.94 times and 1.06 times shall be performed. 4.5. Test Specification According to EN 61000-3-2: 2000 Page: 25 of 74

4.6. Test Result Product Digital Ink Pad Test Item Power Harmonics Test Mode Mode 1: Normal Operation Date of Test 2005/07/19 Test Site No.1 Shielded Room Urms = 230.1V Freq = 50.000 Range: 5 A Irms = 0.435A Ipk = 1.838A cf = 4.230 P = 47.12W S = 100.00VA pf = 0.471 THDi = 88.4 % THDu = 0.10 % Class A Test - Time : 5min ( 100 %) Test completed, Result: PASSED Order Freq. Iavg Iavg%L Imax Imax%L Limit [Hz] [A] [%] [A] [%] [A] 1 50 0.2073 0.2216 2 100 0.0000 0.0000 0.0018 0.1695 1.0800 3 150 0.1975 8.5868 0.2106 9.1553 2.3000 4 200 0.0000 0.0000 0.0018 0.4258 0.4300 5 250 0.1847 16.199 0.1956 17.159 1.1400 6 300 0.0000 0.0000 0.0021 0.7121 0.3000 7 350 0.1664 21.604 0.1743 22.631 0.7700 8 400 0.0000 0.0000 0.0021 0.9288 0.2300 9 450 0.1440 35.993 0.1498 37.460 0.4000 10 500 0.0000 0.0000 0.0024 1.3269 0.1840 11 550 0.1194 36.183 0.1242 37.638 0.3300 12 600 0.0000 0.0000 0.0024 1.5922 0.1533 13 650 0.0946 45.026 0.0986 46.939 0.2100 14 700 0.0000 0.0000 0.0021 1.6254 0.1314 15 750 0.0710 47.304 0.0745 49.642 0.1500 16 800 0.0000 0.0000 0.0018 1.5922 0.1150 17 850 0.0502 37.899 0.0531 40.120 0.1324 18 900 0.0000 0.0000 0.0018 1.7912 0.1022 19 950 0.0330 27.897 0.0357 30.151 0.1184 20 1000 0.0000 0.0000 0.0015 1.6586 0.0920 21 1050 0.0202 18.844 0.0223 20.793 0.1071 22 1100 0.0000 0.0000 0.0012 1.4595 0.0836 23 1150 0.0120 12.276 0.0137 14.038 0.0978 24 1200 0.0000 0.0000 0.0009 1.1942 0.0767 25 1250 0.0086 9.5007 0.0095 10.512 0.0900 26 1300 0.0000 0.0000 0.0009 1.2937 0.0708 27 1350 0.0079 9.4880 0.0085 10.254 0.0833 28 1400 0.0000 0.0000 0.0006 0.9288 0.0657 29 1450 0.0078 10.103 0.0082 10.620 0.0776 30 1500 0.0000 0.0000 0.0006 0.9951 0.0613 31 1550 0.0073 10.126 0.0076 10.512 0.0726 32 1600 0.0000 0.0000 0.0003 0.5307 0.0575 33 1650 0.0068 9.9519 0.0070 10.295 0.0682 34 1700 0.0000 0.0000 0.0003 0.5639 0.0541 35 1750 0.0061 9.5090 0.0064 9.9691 0.0643 36 1800 0.0000 0.0000 0.0003 0.5971 0.0511 37 1850 0.0053 8.6418 0.0058 9.5350 0.0608 38 1900 0.0000 0.0000 0.0003 0.6303 0.0484 39 1950 0.0001 0.1862 0.0049 8.4635 0.0577 40 2000 0.0000 0.0000 0.0003 0.6634 0.0460 Page: 26 of 74

4.7. Test Photo Test Mode : Mode 1: Normal Operation Description: Power Harmonics Test Setup Page: 27 of 74

5. Voltage Fluctuation and Flicker 5.1. Test Equipment The following test equipment are used during the test: Item Equipment Manufacturer Model No. / Serial No. Last Cal. 1 EMC Emission Tester EMC PARTNER AG Switzerland HARMONIC-1000-1P/ 109 Mar., 2005 2 No.1 Shielded Room N/A Note: All equipment upon which need to calibrated are with calibration period of 1 year. 5.2. Test Setup Page: 28 of 74

5.3. Limits The following limits apply: - the value of P st shall not be greater than 1.0; - the value of P 1t shall not be greater than 0.65; - the value of d(t) during a voltage change shall not exceed 3.3 % for more than 500 ms; - the relative steady-state voltage change, d c, shall not exceed 3.3 %; - the maximum relative voltage change, d max, shall not exceed; a) 4 % without additional conditions; b) 6 % for equipment which is: - switched manually, or - switched automatically more frequently than twice per day, and also has either a delayed restart (the delay being not less than a few tens of seconds), or manual restart, after a power supply interruption. NOTE The cycling frequency will be further limited by the P st and P 1t limit. For example: a d max of 6%producing a rectangular voltage change characteristic twice per hour will give a P 1t of about 0.65. c) 7 % for equipment which is: - attended whilst in use (for example: hair dryers, vacuum cleaners, kitchen equipment such as mixers, garden equipment such as lawn mowers, portable tools such as electric drills), or - switched on automatically, or is intended to be switched on manually, no more than twice per day, and also has either a delayed restart (the delay being not less than a few tens of seconds) or manual restart, after a power supply interruption. P st and P 1t requirements shall not be applied to voltage changes caused by manual switching. 5.4. Test Procedure The EUT is supplied in series with power analyzer from a power source having the same normal voltage and frequency as the rated supply voltage and the equipment under test. And the rated voltage at the supply voltage of EUT of 0.94 times and 1.06 times shall be performed. 5.5. Test Specification According to EN 61000-3-3:1995+A1: 2001 Page: 29 of 74

5.6. Test Result Product Digital Ink Pad Test Item Voltage Fluctuation and Flicker Test Mode Mode 1: Normal Operation Date of Test 2005/07/19 Test Site No.1 Shielded Room Urms = 229.9V Freq = 50.000 Range: 5 A Irms = 0.413A Ipk = 1.624A cf = 3.935 P = 47.12W S = 94.86VA pf = 0.497 Test - Time : 1 x 10min = 10min ( 100 %) LIN (Line Impedance Network) : L: 0.24ohm +j0.15ohm N: 0.16ohm +j0.10ohm Limits : Plt : 0.65 Pst : 1.00 dmax : 4.00 % dc : 3.30 % dtlim: 3.30 % dt>lim: 500ms Test completed, Result: PASSED Page: 30 of 74

5.7. Test Photo Test Mode : Mode 1: Normal Operation Description: Voltage Fluctuation and Flicker Test Setup Page: 31 of 74

6. Electrostatic Discharge (ESD) 6.1. Test Equipment The following test equipment are used during the test: Item Equipment Manufacturer Model No. / Serial No. Last Cal. 1 EM TEST EM UCS 500-M / UCS500M4 Jan., 2005 2 Electrostatic Discharge EM P18 / 1198-34 Jan., 2005 3 Horizontal Coupling Plane(HCP) QuieTek HCP AL50 N/A 4 Vertical Coupling Plane(VCP) QuieTek VCP AL50 N/A 5 No.1 Shielded Room N/A Note: All equipment upon which need to calibrated are with calibration period of 1 year. 6.2. Test Setup Page: 32 of 74

6.3. Limits Item Environmental Phenomena Units Test Specification Performance Criteria Enclosure Port Electrostatic Discharge kv(charge Voltage) ±8 Air Discharge ±4 Contact Discharge B 6.4. Test Procedure Direct application of discharges to the EUT: Contact discharge was applied only to conductive surfaces of the EUT. Air discharges were applied only to non-conductive surfaces of the EUT. During the test, it was performed with single discharges. For the single discharge time between successive single discharges will be keep longer 1 second. It was at least ten single discharges with positive and negative at the same selected point. The selected point, which was performed with electrostatic discharge, was marked on the red label of the EUT. Indirect application of discharges to the EUT: Vertical Coupling Plane (VCP): The coupling plane, of dimensions 0.5m x 0.5m, is placed parallel to, and positioned at a distance 0.1m from, the EUT, with the Discharge Electrode touching the coupling plane. The four faces of the EUT will be performed with electrostatic discharge. It was at least ten single discharges with positive and negative at the same selected point. Horizontal Coupling Plane (HCP): The coupling plane is placed under to the EUT. The generator shall be positioned vertically at a distance of 0.1m from the EUT, with the Discharge Electrode touching the coupling plane. The four faces of the EUT will be performed with electrostatic discharge. It was at least ten single discharges with positive and negative at the same selected point. 6.5. Test Specification According to IEC 61000-4-2 Edition 1.2: 2001-04 Page: 33 of 74

6.6. Test Result Product Digital Ink Pad Test Item Electrostatic Discharge (ESD) Test Mode Mode 1: Normal Operation Date of Test 2005/07/19 Test Site No.1 Shielded Room Item Amount of Discharge Voltage Required Criteria Complied To Criteria (A,B,C) Results Air Discharge 10 10 +8kV -8kV B B A A Pass Pass Contact Discharge 50 50 +4kV -4kV B B A A Pass Pass Indirect Discharge 50 +4kV B A Pass (HCP) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Front) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Left) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Back) 50-4kV B A Pass Indirect Discharge 50 +4kV B A Pass (VCP Right) 50-4kV B A Pass NR: No Requirement Meet criteria A: Operate as intended during and after the test Meet criteria B: Operate as intended after the test Meet criteria C: Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at kv. No false alarms or other malfunctions were observed during or after the test. Remark: The Contact discharges were applied-at least total 200 discharges at a minimum of four test points. Page: 34 of 74

6.7. Test Photo Test Mode : Mode 1: Normal Operation Description: Electrostatic Discharge (ESD) Test Setup Page: 35 of 74

7. Radiated Susceptibility (RS) 7.1. Test Equipment The following test equipment are used during the test: Item Equipment Manufacturer Model No. / Serial No. Last Cal. 1 Signal Generator R & S SYM02 / 825454/029 Jan., 2005 2 Power Amplifier A & R 100W10000M7 / A285000010 3 RF Power Amplifier OPHIRRF 5022F / 1075 N/A 4 Bilog Antenna Chase CBL6112B / 2452 Sep., 2004 5 Power Meter R & S NRVD / 100219 Sep., 2004 6 Directional Coupler A & R DC6180 / 22735 Feb., 2005 7 No.4 EMC Fully Chamber Jul., 2005 Note: All equipment upon which need to calibrated are with calibration period of 1 year. N/A 7.2. Test Setup Page: 36 of 74

7.3. Limits Item Environmental Phenomena Units Test Specification Performance Criteria Enclosure Port Radio-Frequency MHz 80-1000 Electromagnetic Field V/m(Un-modulated, rms) 3 A Amplitude Modulated % AM (1kHz) 80 7.4. Test Procedure The EUT and load, which are placed on a table that is 0.8 meter above ground, are placed with one coincident with the calibration plane such that the distance from antenna to the EUT was 3 meters. Both horizontal and vertical polarization of the antenna and four sides of the EUT are set on measurement. In order to judge the EUT performance, a CCD camera is used to monitor EUT screen. All the scanning conditions are as follows: Condition of Test Remarks 1. Field Strength 3 V/m Level 2 2. Radiated Signal AM 80% Modulated with 1kHz 3. Scanning Frequency 80MHz - 1000MHz 4 Dwell Time 3 Seconds 5. Frequency step size f : 1% 6. The rate of Swept of Frequency 1.5 x 10-3 decades/s 7.5. Test Specification According to IEC 61000-4-3: 2002+A1: 2002 Page: 37 of 74

7.6. Test Result Product Digital Ink Pad Test Item Radiated Susceptibility (RS) Test Mode Mode 1: Normal Operation Date of Test 2005/07/14 Test Site No.4 Chamber Frequency (MHz) Position (Angle) Polarity (H or V) Field Strength (V/m) Required Criteria Complied To Criteria (A,B,C) Results 80-1000 0 H 3 A A Pass 80-1000 0 V 3 A A Pass 80-1000 90 H 3 A A Pass 80-1000 90 V 3 A A Pass 80-1000 180 H 3 A A Pass 80-1000 180 V 3 A A Pass 80-1000 270 H 3 A A Pass 80-1000 270 V 3 A A Pass Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at V/m at frequency MHz. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. Page: 38 of 74

7.7. Test Photo Test Mode : Mode 1: Normal Operation Description: Radiated Susceptibility (RS) Test Setup Page: 39 of 74

8. Electrical Fast Transient/Burst (EFT/B) 8.1. Test Equipment The following test equipment are used during the test: Item Equipment Manufacturer Model No. / Serial No. Last Cal. 1 EM TEST EM UCS 500-M / UCS500M4 Jan., 2005 2 Clamp HAEFELY 093 506.1 / 083 593-23 Jan., 2005 3 No.1 Shielded Room N/A Note: All equipment upon which need to calibrated are with calibration period of 1 year. 8.2. Test Setup Page: 40 of 74

8.3. Limits Item Environmental Phenomena Units Test Specification Performance Criteria I/O and communication ports Fast Transients Common kv (Peak) +0.5 Mode Tr/Th ns 5/50 B Rep. Frequency khz 5 Input DC Power Ports Fast Transients Common kv (Peak) +0.5 Mode Tr/Th ns 5/50 B Rep. Frequency khz 5 Input AC Power Ports Fast Transients Common kv (Peak) +1 Mode Tr/Th ns 5/50 B Rep. Frequency khz 5 8.4. Test Procedure The EUT is placed on a table that is 0.8 meter height. A ground reference plane is placed on the table, and uses a 0.1m insulation between the EUT and ground reference plane. The minimum area of the ground reference plane is 1m*1m, and 0.65mm thick min, and projected beyond the EUT by at least 0.1m on all sides. Test on I/O and communication ports: The EFT interference signal is through a coupling clamp device couples to the signal and control lines of the EUT with burst noise for 1minute. Test on power supply ports: The EUT is connected to the power mains through a coupling device that directly couples the EFT/B interference signal. Each of the Line and Neutral conductors is impressed with burst noise for 1 minute. The length of the signal and power lines between the coupling device and the EUT is 0.5m. 8.5. Test Specification According to IEC 61000-4-4: 2004 Page: 41 of 74

8.6. Test Result Product Digital Ink Pad Test Item Electrical Fast Transient/Burst (EFT/B) Test Mode Mode 1: Normal Operation Date of Test 2005/07/19 Test Site No.1 Shielded Room Inject Line Polarity Voltage kv Inject Time (Second) Inject Method Required Criteria Complied to Criteria Result L ± 1kV 60 Direct B A Pass N ± 1kV 60 Direct B A Pass PE ± 1kV 60 Direct B A Pass L+N ± 1kV 60 Direct B A Pass L+PE ± 1kV 60 Direct B A Pass N+PE ± 1kV 60 Direct B A Pass L+N+PE ± 1kV 60 Direct B A Pass Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at kv of Line. No false alarms or other malfunctions were observed during or after the test. Page: 42 of 74

8.7. Test Photo Test Mode : Mode 1: Normal Operation Description: Electrical Fast Transient/Burst (EFT/B) Test Setup Page: 43 of 74

9. Surge 9.1. Test Equipment The following test equipment are used during the test: Item Equipment Manufacturer Model No. / Serial No. Last Cal. 1 EM TEST EM UCS 500-M / UCS500M4 Jan., 2005 2 No.1 Shielded Room N/A Note: All equipment upon which need to calibrated are with calibration period of 1 year. 9.2. Test Setup Page: 44 of 74

9.3. Limits Item Environmental Phenomena Units Test Specification Performance Criteria Signal Ports and Telecommunication Ports(See 1) and 2) ) Surges Tr/Th us 1.2/50 (8/20) Line to Ground kv ± 1 B Input DC Power Ports Surges Tr/Th us 1.2/50 (8/20) Line to Ground kv ± 0.5 B AC Input and AC Output Power Ports Surges Line to Line Line to Ground Tr/Th us kv kv 1.2/50 (8/20) ± 1 ± 2 B Notes: 1) Applicable only to ports which according to the manufacturer s may directly to outdoor cables. 2) Where normal functioning cannot be achieved because of the impact of the CDN on the EUT, no immunity test shall be required. 9.4. Test Procedure The EUT and its load are placed on a table that is 0.8 meter above a metal ground plane measured 1m*1m min. and 0.65mm thick min. And projected beyond the EUT by at least 0.1m on all sides. The length of power cord between the coupling device and the EUT shall be 2m or less. For Input and Output AC Power or DC Input and DC Output Power Ports: The EUT is connected to the power mains through a coupling device that directly couples the Surge interference signal. The surge noise shall be applied synchronized to the voltage phase at 0 0, 90 0, 180 0, 270 0 and the peak value of the a.c. voltage wave. (Positive and negative) Each of Line-Earth and Line-Line is impressed with a sequence of five surge voltages with interval of 1 min. 9.5. Test Specification According to IEC 61000-4-5 Edition 1.1: 2001-04 Page: 45 of 74

9.6. Test Result Product Digital Ink Pad Test Item Surge Test Mode Mode 1: Normal Operation Date of Test 2005/07/19 Test Site No.1 Shielded Room Inject Line Polarity Angle Voltage kv Time Interval (Second) Inject Method Required Criteria Complied to Criteria Result L-N ± 0 1kV 60 Direct B A Pass L-N ± 90 1kV 60 Direct B A Pass L-N ± 180 1kV 60 Direct B A Pass L-N ± 270 1kV 60 Direct B A Pass N-PE ± 0 2kV 60 Direct B A Pass N-PE ± 90 2kV 60 Direct B A Pass N-PE ± 180 2kV 60 Direct B A Pass N-PE ± 270 2kV 60 Direct B A Pass L-PE ± 0 2kV 60 Direct B A Pass L-PE ± 90 2kV 60 Direct B A Pass L-PE ± 180 2kV 60 Direct B A Pass L-PE ± 270 2kV 60 Direct B A Pass Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at kv of Line. No false alarms or other malfunctions were observed during or after the test. Page: 46 of 74

9.7. Test Photo Test Mode : Mode 1: Normal Operation Description: Surge Test Setup Page: 47 of 74

10. Conducted Susceptibility (CS) 10.1. Test Equipment The following test equipment are used during the test: Item Equipment Manufacturer Model No. / Serial No. Last Cal. 1 Signal Generator R & S SYM01 / 10065 Jan., 2005 2 Power Amplifier A & R 150A220 / 23076 N/A 3 Power Meter HP EPM-4418A / GB37482040 Feb., 2005 4 Power Sensor Agilent 8482A / MY41091031 Aug., 2004 5 Directional Coupler A & R DC2600 / 23325 Feb., 2005 6 CDN Lüthi CDN L-801 M1 / 2047 Jun., 2005 7 CDN Lüthi CDN L-801 M2/M3 / 2043 Jun., 2005 8 FIXED PAD TRILITHIC HFP-525-3/6-NF/NF / N/A N/A 9 EM Clamp Lüthi EM101 / 3552C Apr., 2005 10 No.5 Shielded Room N/A Note: All equipment upon which need to calibrated are with calibration period of 1 year. 10.2. Test Setup Page: 48 of 74

10.3. Limits Item Environmental Phenomena Units Test Specification Performance Criteria Signal Ports and Telecommunication Ports Radio-Frequency MHz Continuous Conducted V (rms, Un-modulated) % AM (1kHz) Input DC Power Ports Radio-Frequency MHz Continuous Conducted V (rms, Un-modulated) % AM (1kHz) Input AC Power Ports Radio-Frequency MHz Continuous Conducted V (rms, Un-modulated) % AM (1kHz) 10.4. Test Procedure 0.15-80 3 80 0.15-80 3 80 0.15-80 3 80 A A A The EUT are placed on a table that is 0.8 meter height, and a Ground reference plane on the table, EUT are placed upon table and use a 10cm insulation between the EUT and Ground reference plane. For Signal Ports and Telecommunication Ports The disturbance signal is through a coupling and decoupling networks (CDN) or EM-clamp device couples to the signal and Telecommunication lines of the EUT. For Input DC and AC Power Ports The EUT is connected to the power mains through a coupling and decoupling networks for power supply lines. And directly couples the disturbances signal into EUT. Used CDN-M2 for two wires or CDN-M3 for three wires. All the scanning conditions are as follows: Condition of Test Remarks 1. Field Strength 130dBuV(3V) Level 2 2. Radiated Signal AM 80% Modulated with 1kHz 3. Scanning Frequency 0.15MHz 80MHz 4 Dwell Time 3 Seconds 5. Frequency step size f : 1% 6. The rate of Swept of Frequency 1.5 x 10-3 decades/s 10.5. Test Specification According to IEC 61000-4-6 Edition 2.1: 2004-11 Page: 49 of 74

10.6. Test Result Product Digital Ink Pad Test Item Conducted Susceptibility (CS) Test Mode Mode 1: Normal Operation Date of Test 2005/07/19 Test Site No.5 Shielded Room Frequency Voltage Inject Tested Port of Required Performance Result Range Applied Method EUT Criteria Criteria (MHz) dbuv(v) Complied To 0.15~80 130 (3V) CDN AC IN A A PASS Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at dbuv(v) at frequency MHz. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. Page: 50 of 74

10.7. Test Photo Test Mode : Mode 1: Normal Operation Description: Conducted Susceptibility (CS) Test Setup Page: 51 of 74

11. Power Frequency Magnetic Field 11.1. Test Equipment The following test equipment are used during the test: Item Equipment Manufacturer Model No. / Serial No. Last Cal. 1 Magnetic Field Testing HAEFELY MAG100 / 080 938-05 May, 2005 2 Triaxial ELF Magnetic Field Meter F.B.BELL 4090 / 9852 Apr., 2005 3 No.1 Shielded Room N/A Note: All equipment upon which need to calibrated are with calibration period of 1 year. 11.2. Test Setup Page: 52 of 74

11.3. Limits Item Environmental Phenomena Units Test Specification Performance Criteria Enclosure Port Power-Frequency Magnetic Field Hz A/m (r.m.s.) 50 1 A 11.4. Test Procedure The EUT and its load are placed on a table which is 0.8 meter above a metal ground plane measured at least 1m*1m min. The test magnetic field shall be placed at central of the induction coil. The test magnetic Field shall be applied 10minutes by the immersion method to the EUT. And the induction coil shall be rotated by 90 in order to expose the EUT to the test field with different orientation (X, Y, Z Orientations). 11.5. Test Specification According to IEC 61000-4-8 Edition 1.1: 2001-03 Page: 53 of 74

Test Result Product Digital Ink Pad Test Item Power Frequency Magnetic Field Test Mode Mode 1: Normal Operation Date of Test 2005/07/19 Test Site No.1 Shielded Room Polarization Frequency Magnetic Required Performance Test Result (Hz) Strength Performance Criteria (A/m) Criteria Complied To X Orientation 50 1 A A PASS Y Orientation 50 1 A A PASS Z Orientation 50 1 A A PASS Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information EUT stopped operation and could / could not be reset by operator at A/m. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. Page: 54 of 74

11.6. Test Photo Test Mode : Mode 1: Normal Operation Description: Power Frequency Magnetic Field Test Setup Page: 55 of 74

12. Voltage Dips and Interruption 12.1. Test Equipment The following test equipment are used during the test: Item Equipment Manufacturer Model No. / Serial No. Last Cal. 1 EM TEST EM UCS 500-M / UCS500M4 Jan., 2005 2 No.1 Shielded Room N/A Note: All equipment upon which need to calibrated are with calibration period of 1 year. 12.2. Test Setup Page: 56 of 74

12.3. Limits Item Environmental Phenomena Units Test Specification Performance Criteria Input AC Power Ports Voltage Dips % Reduction Period 30 25 C % Reduction Period >95 0.5 B Voltage Interruptions % Reduction Period > 95 250 C 12.4. Test Procedure The EUT and its load are placed on a table which is 0.8 meter above a metal ground plane measured 1m*1m min. And 0.65mm thick min. And projected beyond the EUT by at least 0.1m on all sides. The power cord shall be used the shortest power cord as specified by the manufacturer. For Voltage Dips/ Interruptions test: The selection of test voltage is based on the rated power range. If the operation range is large than 20% of lower power range, both end of specified voltage shall be tested. Otherwise, the typical voltage specification is selected as test voltage. The EUT is connected to the power mains through a coupling device that directly couples to the Voltage Dips and Interruption Generator. The EUT shall be tested for 30% voltage dip of supplied voltage and duration 25 Periods, for 95% voltage dip of supplied voltage and duration 0.5 Periods with a sequence of three voltage dips with intervals of 10 seconds, and for 95% voltage interruption of supplied voltage and duration 250 Periods with a sequence of three voltage interruptions with intervals of 10 seconds. Voltage phase shifting are shall occur at 0 0, 45 0, 90 0,135 0,180 0,225 0, 270 0,315 0 of the voltage. 12.5. Test Specification According to IEC 61000-4-11 Second Edition: 2004-03 Page: 57 of 74

12.6. Test Result Product Digital Ink Pad Test Item Voltage Dips and Interruption Test Mode Mode 1: Normal Operation Date of Test 2005/07/19 Test Site No.1 Shielded Room Voltage Dips and Angle Test Required Performance Test Result Interruption Reduction(%) Duration (Periods) Performance Criteria Criteria Complied To 30 0 25 C A PASS 30 45 25 C A PASS 30 90 25 C A PASS 30 135 25 C A PASS 30 180 25 C A PASS 30 225 25 C A PASS 30 270 25 C A PASS 30 315 25 C A PASS >95 0 0.5 B A PASS >95 45 0.5 B A PASS >95 90 0.5 B A PASS >95 135 0.5 B A PASS >95 180 0.5 B A PASS >95 225 0.5 B A PASS >95 270 0.5 B A PASS >95 315 0.5 B A PASS >95 0 250 C C PASS >95 45 250 C C PASS >95 90 250 C C PASS >95 135 250 C C PASS >95 180 250 C C PASS >95 225 250 C C PASS >95 270 250 C C PASS >95 315 250 C C PASS Meet criteria A : Operate as intended during and after the test Meet criteria B : Operate as intended after the test Meet criteria C : Loss/Error of function Additional Information The nominal voltage of EUT is 230V. EUT stopped operation and could / could not be reset by operator at. No false alarms or other malfunctions were observed during or after the test. The acceptance criteria were met, and the EUT passed the test. Page: 58 of 74

12.7. Test Photo Test Mode : Mode 1: Normal Operation Description: Voltage Dips and Interruption Test Setup Page: 59 of 74

Attachement EUT Photograph (1) EUT Photo (2) EUT Photo Page: 60 of 74

(3) EUT Photo (4) EUT Photo Page: 61 of 74

(5) EUT Photo (6) EUT Photo Page: 62 of 74

(7) EUT Photo Page: 63 of 74

(8) EUT Photo Page: 64 of 74

(9) EUT Photo (10) EUT Photo Page: 65 of 74

(11) EUT Photo (12) EUT Photo Page: 66 of 74

(13) EUT Photo (14) EUT Photo Page: 67 of 74

(15) EUT Photo (16) EUT Photo Page: 68 of 74

(17) EUT Photo (18) EUT Photo Page: 69 of 74

(19) EUT Photo (20) EUT Photo Page: 70 of 74

(21) EUT Photo (22) EUT Photo Page: 71 of 74

(23) EUT Photo (24) EUT Photo Page: 72 of 74

(25) EUT Photo (26) EUT Photo Page: 73 of 74

Reference : Laboratory of License Page: 74 of 74