gabotherm Skirting Board Systems gabotherm Comfort (Heating Skirting Board) 58 Comfort E (Heating and Electric Skirting Board) 59

Similar documents
Simplex Baseboard System Baseboard System

4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories

A q u a r i u s 3 5 M e d i u m a n d A q u a r i u s 3 5 W i d e

Table and Furniture Base Fittings Plinth Adjusting Fittings

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request

Digital flow ELEMENT transmitter for continuous flow measurement

REMA FLAT BLADE CONTACT CONNECTORS SR50 SR175 SR350

Customer Premise. Solutions for. Solutions for Customer Premise include products ranging from wall distribution to system distribution boxes.

Digital flow ELEMENT transmitter for continuous flow measurement

Section 11 CABLE & ROD SYSTEMS, SIGN FIXING & SIGN STANDOFFS. Web. acrylicdesign.ie .

Rod Display Systems. Catalogue. Cable Display / Rod Display / Standoff Display

Valve Island with Electronic I/O

SW 16mm. SW 15mm. SW 19mm

CONSTRUCTION PRODUCT TECHNICAL CARD

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS General Certifi cate of Education Ordinary Level

Ø mm. SYSTEM KAN therm. Press LBP. Innovativeness and uniqueness - One system, six functions TECHNOLOGY OF SUCCESS ISO 9001

Ø mm. SYSTEM KAN-therm. Press LBP. Innovativeness and uniqueness - One system, six functions TECHNOLOGY OF SUCCESS ISO 9001

CADprofi Table of contents list of new features in CADprofi 11.07:

NEW. Automation Technology 768 series

Digital conductivity transmitter

Setting Standards Connectors M 16

Products catalogue (I-P Edition)

Organisational Kitchen Fittings Kitchen Cabinet Accessories

the LooX LIgHtINg SySteM LeD lighting systems for furniture and furnishings

Cable glands and accessories

Door Hinges Drill-in Hinges

Mineral-insulated resistance thermometers to EN

Accessories for sensors

XV 1000 PARTS MANUAL Carousel ATC Fanuc / Siemens May 2007

ph or ORP Transmitter

CONSTRUCTION PRODUCT TECHNICAL CARD

OptiLine 45 Floor boxes

NEWS KNIPEX Quality Made in Germany

Product features and advantages

COYOTE Terminal Closure (Single Chamber) Hermetically Sealed With Hardened Adapters

WM en. Zero point clamping system SPEEDY hydratec 1

150mm to 200mm. With box in comp 2 2 = 1535mm² total area 2 = 691mm² 45% space factor. C. & C. Marshall Ltd.

KK series CABLE CARRIER MADE OF PLASTIC VERY SHORT END CONNECTORS DIRT RESISTANT

EDGE-, COVER-, SLIDEAND SEALING PROFILES

MIG/MAG Welding Torch ABIMIG 401 WT / ABIMIG 501 WT liquid-cooled, with divided liner

Installation Tools. Pipe Cutters for steel and cast iron pipes 598. Deburring Reamer / for stainless steel pipes 600. for copper pipes 602

...Your environment is our business

Conductivity Transmitter

Test Joints / Fixed Earthing Terminals

General Array Layout Sketch

TEMPERATURE PROBE. Temperature probe. Handheld instrument. Display / Controller. Logger / EASYBus. Transmitter. Application: NiCr-Ni (Type K)

Ultra-efficient installation solutions

Polished head, handles black atramentised. Polished head, dip-coated handles. Length mm

Cable Management Solutions with DLP TM

WSG 8-115; 8-125; P; WSG ; WSG P; WSG PS; WSG P; WSG 15-70Inox

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header

ELECTRICAL INFORMATION K012-A135-MP5.0/02 2 K012-A135-MP5.0/03 3. Molding Nylon PA66 to UL94, V-O Colour Green. Torque 3.5 lbs-in

METRIC LIGHTNING PROTECTION PRODUCTS

USB 2.0-IP67 Water Resistant Connector System

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

Current / residual current and voltage transformers. Current / residual current and voltage transformers

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

MIG/MAG Welding Torch System ROBO WH 455 D ROBO WHPP 455 D liquid cooled

elemento In general 2 Weights 2 Parts of the Elemento... 2 Mounting the Elemento.. 3 Placing the power cable... 4 Placing the controls...

Moveable Workstations. Enterprise KEWAUNEE. encouraging new discovery...worldwide

Factory Assistance: Phone: Fax: Page 1

Empfangsantennen / Receiving ROD Antennas STA E, STA E / EAU

Combination Pliers. Pliers. Long Nose Pliers, straight. Bent Nose Pliers, 200 mm. Flat Nose Pliers, 160 mm 2013/2014

Digital inductive conductivity transmitter

SOLDERING & BRAZING SOLDERING & BRAZING

77 cm. 5243/3-GA (3 pcs.) 5243/3-BO (3 pcs.)

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

SIT Group FLUE SYSTEMS

The new underfloor trunking system tehalit.bk broadway. Invisible perfection

SIGNAL // POWER // INDUSTRIAL ETHERNET

Online data sheet VTF18-4N1212 V18 CYLINDRICAL PHOTOELECTRIC SENSORS

installation instructions WC Frame 1180mm with Dual Flush Cistern

Sport-Thieme Handball Goal, 3x2 m, Free-Standing or socketed

RASCH / SAFIX. Release Numbering at RASCH / SAFIX. Structure of families with additional functions. Summary of the forms

installation instructions

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certifi cate of Secondary Education

CADprofi Summary of main changes made to the program since the CADprofi version.

Resistance Thermometers Model Series TR7X0, Sheathed Design

PLASTIC PIPE WELDING PLASTIC PIPE WELDING

Safety switches with slotted hole lever

Air-supply elements. Air-supply elements MGE Flanged plate (p. 5-3) M12-1/4" (p. 5-4) Longitudinal end connector (p.

INSERTION paddle wheel flowmeter for continuous flow measurement

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certifi cate of Secondary Education

NEWLONG. r PORTABLE FILLED BAG CLOSING MACHINE NEWLONG MACHINE WORKS, LTD.

ImproX (MMA) 125 khz Mullion Antenna Reader INSTALLATION MANUAL

YJ Bow Assembly. Installation Instructions INSTALLATION TIME SKILL LEVEL TOOLS. Vehicle Application: Jeep Wrangler YJ Part Number: 55004

KNIPEX Quality Made in Germany. Product Presentation. at the Point of Sale. Preliminary version - for internal use only!

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certifi cate of Secondary Education

W 23-2: Focussing on what is essential and economic

vacon nxs/p ac drives flange mounting kit for fr4-fr6 installation manual

MEFA mounting accessories

Flush Round Single or Multi-Service Non-Metallic Concrete Floor Box Floor Boxes

Trunking. light grey in U23X. Industrial Catalogue

600G2 Internal Sliding Adapter Panel Shelf Instructions

PCS. Patient Security Service Console. Installation Instructions.

D300K 3+3 SE KUBOTA PARTS LIST FOR RETURN TO MAIN INDEX

Installation instructions and notes on implementation of an intermeshed equipotential bonding system with EMClots

Screw-in resistance thermometers with terminal head Form B

Bracket guide. LK Pipe Pole. LK Radiator fixture Uni

WASP Extended Shuttle Fitting. Process Overview

Transcription:

Skirting Board Systems Comfort (Heating Skirting Board) 58 Comfort E (Heating and Electric Skirting Board) 59 Pipes / Fastenings 60 Connection Units 61 55

Skirting Board Systems: Comfort Comfort (Heating Skirting Board): Skirting board system for integrating oxygen-impermeable polybutene pipes with an outside diameter of 18.0 mm for connecting radiators. Skirting boards are especially used in the restoration of old buildings for installing heating pipes without having to perform chiselling and welding. This allows for a fast and clean installation. The Comfort skirting board (front and rear wall) incl. the fi ttings is available in different colours (, grey, light oak) and thus blends in with any room. The twin-wall skirting board (HxW = 90 x 45 mm) reduces heat loss through the exterior wall or to non-heated rooms. Two soft lips ensure that any unevenness of the walls or the fl oor is compensated for. Different connection units for the connection to the radiator are available as press or clamp connections for both single and dual-pipe systems. The PB heating pipes 18 x 2.0 mm are connected to the manifold for connecting radiators using euro-cone for accommodating clamp or press adapters or to an ascending pipe on the building site. 56

Skirting Board Systems: Comfort Comfort E (Heating and Electric Skirting Board): Skirting board system for integrating oxygen-impermeable polybutene pipes with an outside diameter of 18.0 mm for connecting radiators, and with electric cables in a separate conduit. The electric conduit corresponds to the requirements according to VDE 0100 T 520 and contains two separate chambers for laying different cable types (e.g. 230 V cables and data cables etc.). Suitable equipment racks are available from TEHALIT (tel. +49 (0)6333 / 992-0). Heating and electric skirting boards are especially used in the restoration of old buildings for installing heating pipes without having to perform chiselling and welding and simultaneously renewing the electrical installations. This permits one step installation of both heating and electrics. The Comfort electric skirting board has a common rear wall and separate front covers for the electric and the heating conduit, which ensures that the two systems can be accessed separately at any time. The twin-wall skirting board (H x W = 120 x 45 mm) prevents heat radiation into the electric conduit. The combined Comfort electric skirting board incl. the fi ttings is only available in. 57

Comfort Skirting Board System Heating Skirting Board and Fittings Heating Skirting Board front profi le and thermally insulating rear wall with soft lips against wall and fl oor, 90 mm high, 45 mm deep, 4 m long, with protective foil on the visible surface, available in grey, and light oak. GK-PNS 5 x 4 m 02728 02737 02730 Heating Skirting Board front profi le, with soft lip against the wall, 90 mm high, 45 mm deep, 4 m long, with protective foil on the visible surface, available in grey, and light oak, fastened to the wall using connecting clamp GK-SBS (item ID 03485). GK-PNF 4 m 03232 03231 02884 External Corner for connecting the skirting board conduit around a corner. GK-A 10 pieces 06824 00899 02798 Internal Corner for connecting the skirting board conduit around a corner. GK-I 10 pieces 06827 00898 02797 Joint Connector for covering skirting board joints. GK-SV 10 pieces 06858 00902 02795 End Cap for sealing the skirting board on the left or right. GK-EL GK-EL (left) 10 pieces 06867 00900 02791 GK-ER GK-ER (right) 10 pieces 06863 00901 02792 Covering Collar made from plastic, with self-adhesive rear side, for covering the skirting board cut-outs at the radiator connections. GK-AR 10 pieces 12193 12194 12759 58

Comfort Skirting Board System Combined Heating / Electric Skirting Board and Fittings Skirting Board with separate electric conduit, 120 mm high, 45 mm deep, 4 m long, colour: with protective foil on the visible surface GK-E 5 x 4 m 05961 External Corner for connecting the skirting board with electric conduit around a corner; colour ; GK-AE 10 pieces 05868 Internal Corner for connecting the skirting board with electric conduit around a corner. GK-IE 10 pieces 05867 End Cap for sealing the skirting board with electric conduit on the left or right. GK-EL GK-ELE (left) 10 pieces 05865 GK-ERE (right) 10 pieces 05864 GK-ER Covering Collar made from plastic, with self-adhesive rear side, for covering the skirting board cut-outs at the radiator connections. GK-AR 10 pieces 12194 Joint Connector for covering joints in the skirting board with electric conduit. GK-SVE 10 pieces 05866 59

Comfort Skirting Board System Pipes Heating Pipe thrice coextruded, oxygen-impermeable (diffusion resistant) polybutene pipe, corresponding to the technical requirements according to DIN 4726/27 and DIN EN 12319, various test certifi cates and certifi cations (MPA, DIN-Certco, KTW and DVGW) are available. Code Dim. Unit Item ID HR-PB DD 18 x 2.0 120 m 04780 Heating Pipe thrice coextruded, oxygen-impermeable (diffusion resistant) polybutene pipe, corresponding to the technical requirements according to DIN 4726/27 and DIN EN 12319, various test certifi cates and certifi cations (MPA, DIN-Certco, KTW and DVGW) are available. Code Dim. Unit Item ID HR-PB DD 18 x 2.0 15 x 4 m 00598 Protective Pipe protects the PB pipe for door underpasses, wall slits and on-wall laying. Code Dim. Unit Item ID GT-SR 25 20 m 04682 Fasteners Pipe Clip for fastening skirting board and PB pipe 18 x 2. GK-RK 50 pieces 06876 Fixed-Point Pipe Clip for fastening skirting board and PB pipe 18 x 2 in internal corners. GK-FK 50 pieces 01453 Skirting Board Connecting Clamp made from plastic, for fastening PB pipes 18 x 2 and skirting board front profi les GK-PNF to the wall. GK-SBS 50 pieces 03485 Pipe Support Bend made from impact-resistant plastic, for bending PB pipes 18 x 2 in corners by 90. GT-RB 15/18 1 piece 12001 60

Comfort Skirting Board System Connection Units, Fittings and Accessories (for Screwing) for radiator connection on both sides incl. 4 GTF-KA 18 x 2 coupling adapters and screws. GK-ZAE Ø 12 1 piece 07869 for the last radiator incl. 2 GTF-KA 18 x 2 coupling adapters and screws. GK-ZAEL Ø 12 1 piece 00754 for valve-radiators incl. 4 GTF-KA 18 x 2 coupling adapters and screws. GK-ZKE Ø 12 1 piece 07868 Single Pipe Connection for inlet and return fl ow incl. 2 GTF-KA 18 x 2 coupling adapters and screws. GK-EAE Ø 15 1 piece 06978 Transition from ½ to ¾ euro-cone, e.g. at the radiator valve, self-sealing with O-ring. GFL-UKAR ½ 10 pieces 01709 Pipe Coupling with ½ external thread according to DIN 8076, made from brass, for connection to the plastic pipe fi ttings. GTF-K 18 x 2 ½ 20 pieces 03498 Coupling Adapter according to DIN 8076, made from brass with euro-cone ¾ internal thread, for connecting PB pipes 18 x 2 to GK fi ttings or valves from Heimeier, Herz, Taco, etc. GTF-KA 18 x 2 20 pieces 07730 T-Piece with euro-cone ¾, for junctions in GK pipes. GFL-TKA ¾ 10 pieces 07911 Coupling adapters must be ordered separately. 61

Comfort Skirting Board System Blank end cap ¾" with seal, for sealing the last double pipe strand. Code Type Unit Item ID GK-BK ¾" 10 pieces 06816 Connection Units, Fittings and Accessories (for Pressing) press connection for radiator connection on both sides incl. 4 pieces GT-PKA 18 and screws. GK-ZAEP 12 1 piece 09086 press connection for the last radiator incl. 2 pieces GT-PKA 18 and screws. GK-ZAELP 12 1 piece 09087 press connection for valve-radiators incl. 4 pieces GT-PKA 18 and screws. GK-ZKEP 12 1 piece 09088 Press-Plug Connection Set for radiators with ¾ external thread, for separate press-plug adapter (GT-PSA) for PB pipe 18 x 2.0, for installation in the gabotherm Comfort skirting board system GK-HAG 12 1 pair 12722 Press-Plug Adapter for installation in above-mentioned connection set Code Type Unit Item ID GT-PSA 18 18 x 2.0 10 pieces 12712 62

Comfort Skirting Board System Press Transition Coupling for the transition from pipes to metal thread. Code Type Unit Item ID 18, ½ external GT-PUK thread 10 pieces 06272 18, ¾ external thread 10 pieces 05782 Press T-Piece for pipes. GT-PT 18/18/18 10 pieces 06290 Press End Cap for sealing PB pipes. GT-PEK 18 10 pieces 11628 Press Couplings for pipes GT-PK 18 10 pieces 06285 Press Elbow for pipes GT-PW 90 18 10 pieces 07762 Connection Pipes for Radiator Connection Units S Copper Pipes Ø 12, nickel-plated, for double pipe connection, distance of radiator axis from the wall 80 105 mm GK-Cu-S 12 1 pair 07859 Copper Pipe Elbows Ø 12, nickel-plated, for double pipe connection, distance of radiator axis from wall 80 105 mm. GK-Cu-W 12 1 pair 06977 Z Copper Pipes Ø 12 and Ø 15, nickel-plated, for single pipe connection, distance of radiator axis from the wall 50 105 mm GK-Cu-Z 12 1 pair 06522 GK-Cu-Z 15 1 pair 06975 63