x-ray Beam Size Monitor

Similar documents
CESRTA Low Emittance Tuning Instrumentation: x-ray Beam Size Monitor

Operation of a Single Pass, Bunch-by-bunch x-ray Beam Size Monitor for the CESR Test Accelerator Research Program. October 3, 2012

OPERATION OF A SINGLE PASS, BUNCH-BY-BUNCH X-RAY BEAM SIZE MONITOR FOR THE CESR TEST ACCELERATOR RESEARCH PROGRAM*

X-Ray Beam Size Monitor for CESRTA

Measurements of Small Vertical Beamsize using a Coded Aperture at Diamond Light Source. C. Bloomer G. Rehm J.W. Flanagan

RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS

A high resolution bunch arrival time monitor system for FLASH / XFEL

Beam Diagnostics, Low Level RF and Feedback for Room Temperature FELs. Josef Frisch Pohang, March 14, 2011

Supplementary Information

X-Ray Transport, Diagnostic, & Commissioning Plans. LCLS Diagnostics and Commissioning Workshop

Overview of performance and improvements to fixed exit double crystal monochromators at Diamond. Andrew Dent, Physical Science Coordinator, DLS

CSPADs: how to operate them, which performance to expect and what kind of features are available

Diamond X-ray Rocking Curve and Topograph Measurements at CHESS

Air Bearing Monochromator at APS 13-ID-E (GSECARS)

pcvd diamond beam position monitors for PETRA III

Results from Diamond Detector tests at ELETTRA

XH Germanium Microstrip Detector for EDAS.

Silicon Photomultiplier Evaluation Kit. Quick Start Guide. Eval Kit SiPM. KETEK GmbH. Hofer Str Munich Germany.

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

DESIGN NOTE: DIFFRACTION EFFECTS

Nano Beam Position Monitor

Novel laser power sensor improves process control

Totem Experiment Status Report

X-ray Detectors: What are the Needs?

Low noise readout techniques for Charge Coupled Devices (CCD) Gustavo Cancelo, Juan Estrada, Guillermo Fernandez Moroni, Ken Treptow, Ted Zmuda

Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4

MS260i 1/4 M IMAGING SPECTROGRAPHS

Large area position-sensitive CVD diamond detectors for X-ray beam monitoring with extreme position resolution

A Prototype Amplifier-Discriminator Chip for the GLAST Silicon-Strip Tracker

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Light gathering Power: Magnification with eyepiece:

Redefining Measurement ID101 OEM Visible Photon Counter

Pulse Shape Analysis for a New Pixel Readout Chip

Criteria for Optical Systems: Optical Path Difference How do we determine the quality of a lens system? Several criteria used in optical design

LCLS project update. John Arthur. LCLS Photon Systems Manager

Water-Window Microscope Based on Nitrogen Plasma Capillary Discharge Source

Shenglan Xu. GM/CA CAT Argonne National Laboratory

FIRST INDIRECT X-RAY IMAGING TESTS WITH AN 88-mm DIAMETER SINGLE CRYSTAL

Copyright 2000 Society of Photo Instrumentation Engineers.

Order Overlap. A single wavelength constructively interferes in several directions A given direction can receive multiple wavelengths.

Introduction... 3 Slits for AIR Operation... 4 Slits in Vacuum Vessels... 5 Slits for High Vacuum Operation... 6 Custom Slits... 7 Steel Slits...

DESIGN OF COMPACT PULSED 4 MIRROR LASER WIRE SYSTEM FOR QUICK MEASUREMENT OF ELECTRON BEAM PROFILE

Adaptive Optics for LIGO

Ultra fast single photon counting chip

X-Ray Detection Using SOI Monolithic Sensors at a Compact High-Brightness X-Ray Source Based on Inverse Compton Scattering

Characterisation of a novel super-polished bimorph mirror

BMC s heritage deformable mirror technology that uses hysteresis free electrostatic

Implementation of A Nanosecond Time-resolved APD Detector System for NRS Experiment in HEPS-TF

Check the LCLS Project website to verify 2 of 7 that this is the correct version prior to use.

Production of HPDs for the LHCb RICH Detectors

Short-Pulse X-ray at the Advanced Photon Source Overview

DEVELOPMENT OF CAPACITIVE LINEAR-CUT BEAM POSITION MONITOR FOR HEAVY-ION SYNCHROTRON OF KHIMA PROJECT

Electron-Bombarded CMOS

LITE /LAB /SCAN /INLINE:

X-ray Detectors at DESY

ABSTRACT. Supported by U.S. DoE grant No. DE-FG02-96ER54375

cividec DIAMOND DETECTORS & SYSTEMS FOR X-RAYS Instrumentation CIVIDEC Instrumentation GmbH Vienna The Netherlands +31 (0)

Studies of a Bulk Micromegas using the Cornell/Purdue TPC

CMS Tracker Upgrade for HL-LHC Sensors R&D. Hadi Behnamian, IPM On behalf of CMS Tracker Collaboration

The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, Kraków, Poland.

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

Filter & Spectrometer Electron Optics

Introduction to X-ray Detectors for Synchrotron Radiation Applications

High-Power, Passively Q-switched Microlaser - Power Amplifier System

Scanning X-ray microscopy with a single photon counting 2D detector

Optimization of the LCLS Single Pulse Shutter

Supplementary Figure 1

ITk silicon strips detector test beam at DESY

Comparison of FMCW-LiDAR system with optical- and electricaldomain swept light sources toward self-driving mobility application

Video-based X-Ray Beam Position Monitoring at CHESS Peter Revesz, Cornell University, CHESS Ithaca, NY 14850

Integrating Analogue to Digital Converter (ADC)

Optical coherence tomography

Week IX: INTERFEROMETER EXPERIMENTS

System Integration of the TPS. J.R. Chen NSRRC, Hsinchu

arxiv: v1 [physics.ins-det] 5 Sep 2011

Guide to SPEX Optical Spectrometer

PIXIS-XB: 1024BR X-RAY GROUP

LUSI Pulse Picker System

PROCEEDINGS OF SPIE. Automated asphere centration testing with AspheroCheck UP

PICO MASTER 200. UV direct laser writer for maskless lithography

Assembly and Experimental Characterization of Fiber Collimators for Low Loss Coupling

Performance of the SASE3 monochromator equipped with a provisional short grating. Variable line spacing grating specifications

CALICE AHCAL overview

ELECTRONICS FOR PULSE PICKERS

ELEC Dr Reji Mathew Electrical Engineering UNSW

Development of gating foils to inhibit ion feedback using FPC production techniques

CyberKnife Iris Beam QA using Fluence Divergence

Test Beam Measurements for the Upgrade of the CMS Phase I Pixel Detector

A Readout ASIC for CZT Detectors

Light Source Diagnostics. Hywel Owen ASTEC Daresbury Laboratory

UNIT VIII-SPECIAL PURPOSE ELECTRONIC DEVICES. 1. Explain tunnel Diode operation with the help of energy band diagrams.

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

A LATERAL SENSOR FOR THE ALIGNMENT OF TWO FORMATION-FLYING SATELLITES

e+/e- Vertical Beam Dynamics during CESR-C Operation

Muon detection in security applications and monolithic active pixel sensors

MEASUREMENT OF BEAM LOSSES USING OPTICAL FIBRES AT THE AUSTRALIAN SYNCHROTRON

Properties of a Detector

Pixel hybrid photon detectors

MINIATURE X-RAY SOURCES AND THE EFFECTS OF SPOT SIZE ON SYSTEM PERFORMANCE

Transcription:

x-ray Beam Size Monitor J. Alexander, N. Eggert, J. Flanagan, W. Hopkins, B. Kreis, M. McDonald, D. Peterson, N. Rider Goals: 2 products: tuning tool with rapid feedback of beam height during LET measurements of beam size evolution in response to beam characteristics Outline: x-ray beam line and detector configuration detector details detector improvements for May 2009 run calibrations capabilities beam tuning product possible improvements future xbsm status 20090626 Dan Peterson, Cornell page 1

The x-ray optics assembly holds a chip with the optical elements. There is currently a chip with 3 elements: square hole Coded Aperture (CA) Fresnel Zone Plate (FZP) Each has a gross size of about 1mm. There is also a vertically limiting adjustable slit. xbsm status 20090626 Dan Peterson, Cornell page 2

The x-ray detector operates in a vacuum, but must be isolated from the CESR vacuum to avoid contamination of CESR and allow quick-turnaround access to the detector. The detector vacuum (~0.5 Torr) is isolated from the x-ray line vacuum (~10-6 Torr ) by a diamond window (next slide). The pressure difference across the diamond window is controlled by this system. Protection from a catastrophic failure is with a gate valve. xbsm status 20090626 Dan Peterson, Cornell page 3

The thin (4um) diamond window separates high quality CESR vacuum low quality vacuum of the detector enclosure. The window transmits 76% of the x-rays at 2.5keV, and is supported by a thick silicon frame; the 4um membrane region is 2mm (horizontal) x 6mm (vertical). The window was fabricated by Diamond Materials GmbH of Freiburg xbsm status 20090626 Dan Peterson, Cornell page 4

The detector box contains movable slits for calibration, and the diode array detector and preamplifiers. The monochometer ia a silicon-tungsten multi-layer mirror. X-ray energies are selected as a function of angle with 1.5% FWHM bandwidth. This well matched the chromatic aberration of the 239 ring FZP. All devices are motor controlled. As this is in a vacuum, the amplifiers are water-cooled. xbsm status 20090626 Dan Peterson, Cornell page 5

Detector: an array of ~ 64 diodes, InGaAs, manufactured by Fermionics Inc., 50µm pitch (1.6mm coverage over 32 diodes), 400µm pixel width. The InGaAs layer id 3.5µm and absorbs 73% of photons at 2.5keV. We instrument 32 contiguous diodes for the fast readout, a FADC with 14ns repetition rate. There are also 8 diodes connected for the DC readout. xbsm status 20090626 Dan Peterson, Cornell page 6

10.186m 4.360m detector optics source magnification: image/source size = 2.34 xbsm status 20090626 Dan Peterson, Cornell page 7

This shows the typical output of the fast and DC readouts. The fast readout uses 32 contiguous diodes, instrumented with preamplifiers, a shaping circuit and 14ns FADCs. The array is in a fixed position during readout. Readout is synchronized to the bunch crossing to measure the peak of the response. The image is observed by the relative response of the 32 diodes. In the DC readout, one of the 8 instrumented diodes is read directly through a pico-ammeter. this is turn average response 32 diodes, FZP, monochrometer, 20090525-2368 The ammeter output is collected, synchronized to the motion of any of the available motions. In this case, the response is w.r.t. the vertical motion of the detector stage. Thus, the single diode is swept through the x-ray image. Integration is ~0.1 sec, the step size is typically less than a diode pitch. this is a slow scan of 1 diode, TADETZ, 2mm motion, FZP, no-mono 20090201 xbsm status 20090626 Dan Peterson, Cornell page 8

May 2009 run Wire Bonding improvement bonding efficiency before: ~25% (above) after: tested 4 boards, all have perfect 32 diode arrays xbsm status 20090626 Dan Peterson, Cornell page 9

Improvements to the fast readout amplifier for the May run Shaping was optimized as shown in the figures. The noise reduction is grounding seen in slide 5. Fermionics no shaping Fermionics 39pF shaping as in January run These are so-called storage oscilloscope runs ; a readout of 1 diode array element is read during many CESR turns with phase advancing 0.5ns / turn. Fermionics 150pF shaping May run xbsm status 20090626 Dan Peterson, Cornell page 10

Mapping was first mapping done by hand. Use narrow focus FZP with monochrometer. Scan the fast readout array across image. Locate array elements with strong signal at each vertical location of the illumination. Determine the physical order of the logical channels. Mapping was later automated, four detector boards mapped and certified There is also a channel-to-channel PH calibration based on the observed signal. This shows the first evidence that the PH and mapping calibrations were working. xbsm status 20090626 Dan Peterson, Cornell page 11

The monochometer is used to mask the chromatic aberration of the FZP; it greatly decreases the image width, thus improving the spatial resolution of the detector. On 20090525, we measured the number of photons reaching the detector by comparing the mean and variation of the PH in the peak channel. Using the FZP monochrometer, 1 bunch, 4.3ma. The observed rate is about 1 photon/(ma of beam) at the peak. Crisis: We will never have enough photons to use the monochrometer in one-turn measurements. a turn-averaged response 32 diodes FZP, monochrometer We investigated the use of white-beam. The image will be a convolution of x-ray energies, with varying amount of defocus. 20090529: Using the DC readout, and a controlled increase in the beam size, we compared the sensitivity of white-beam measurements w.r.t. monochromatic beam, Using FZP, monochrometer, FWHM changes from.21 to.25mm FZP and white-beam, FWHM changes from.46 to.50mm. The relative photon count, at the peak, is 114. 20090601: We verified that the fast readout shape matches the DC readout. Lesson: we can develop the measurement with white-beam. xbsm status 20090626 Dan Peterson, Cornell page 12

20090601: Measured the beam position and image size for 10000 consecutive turns, single bunch beam structure. The measurement is based on fits to the image, as observed in a single turn, with the fast readout. (At this point, it is a simple gaussian fit.) The history of the image position over 10,000 measurements, 0.0256 seconds, shows a disturbance initiated at 60 Hz, with amplitude of 150 µm. The image position measurement accuracy is σ<35µm, as indicated by the narrowest part of the wave form. The history of the image size does not show a correlation with the variation of the position. While the image shape has σ=250 µm, the variation of the image shape is σ σ ~ 35µm. (Based on the slow diode measurements 20090531, we expect σ (image shape) =230 µm.) xbsm status 20090626 Dan Peterson, Cornell page 13

A Fourier analysis of the position disturbance reveals the betatron frequency ~142 khz and the synchrotron frequency ~20 khz. xbsm status 20090626 Dan Peterson, Cornell page 14

The tuning tool (one of our goals) is a chart recorder of the beam size and position that gives feedback to the CESR tuner. We require a faster and stable calculation method for the tuning tool display. Sum distributions from 100 turns. Fit the sum to a gaussian, then refit with 2nd iteration within ± 2σ. With this, we define a window, FW=4σ, for determining center and RMS for individual turns. The window is the same for all turns. Positions are averaged over the 100 turns. Beam sizes (rms), now de-convolved from the position, are averaged over the 100 turns. Update time is ~ 2 seconds. xbsm status 20090626 Dan Peterson, Cornell page 15

(The saved data is more coarse than during measurements.) 20090612, ~22:15 we varied βsing1 position size (σ) µm µm 0 118 175 100 60 185 300-360 192-100 210 190-200 330 210 Current, ma Image Centroid, microns 5.000 4.500 4.000 3.500 3.000 2.500 2.000 1.500 1.000 0.500 0.000 800 700 600 500 400 300 200 100-100 0-200 -300-400 -500-600 -700-800 21.0 21.5 22.0 22.5 23.0 23.5 24.0 24.5 25.0 Time, relative to 20090612 00:00 20.0 20.5 21.0 21.5 22.0 22.5 23.0 23.5 24.0 24.5 25.0 Time, relative to 20090612 00:00 Beam position changes matched earlier observations with the DC readout. Scatter in the beam position and beam size are both ~ ±10 µm. The scatter in the beam size is improved relative to the single turn measurements by averaging. Image Centroid, microns Image Centroid, microns 250 240 230 220 210 200 190 180 170 160 150 20.0 20.5 21.0 21.5 22.0 22.5 23.0 23.5 24.0 24.5 25.0 Time, relative to 20090612 00:00 1000 900 800 700 600 500 400 300 200 100 0 20.0 20.5 21.0 21.5 22.0 22.5 23.0 23.5 24.0 24.5 25.0 Time, relative to 20090612 00:00 xbsm status 20090626 Dan Peterson, Cornell page 16

Next, measure size change over ~20 bunches. We can configure to measure 20 bunches in one turn. But, the turn would be asynchronous with the vertical modulation (below). We can collect and average a total of 10,000 bunch measurements. That would be exhausted in only 500 turns, still not covering a full period of the vertical modulation. To properly average, must reconfigure to (collect 20 bunches in one turn, wait 129 turns) repeat 50 times. Requires DAQ box software mods. xbsm status 20090626 Dan Peterson, Cornell page 17

We are investigating the possibility that using the Coded Aperture, rather the the FZP, will lead to an improvement in resolution. 1.2 1 0.8 FZP Shown are observed slow-scan distributions for the FZP and CA. We create a controlled beam size change with βsing1. Blue is for βsing1=+0; pink is for βsing1=+100. In the case of the FZP, Г=313 and 368µm at the image. 0.6 0.4 0.2 scan 76 scan 77 The peak of the FZP distribution, βsing1=+0, is arbitrarily set to a value of 1. The CA distribution, βsing1=+0, is beam-current normalized to the FZP. 0 45.8 46.8 47.8 48.8 49.8 0.6 In each case (FZP and CA) the βsing1=+100 scan is area normalized to the corresponding βsing1=+0 scan. This is how I would normalize when template-fitting. 0.5 0.4 0.3 CA scan 87 scan 88 I calculate, over a width of 1.6mm, the rms of ((PH(βsing1=+100)-PH(βsing1=+0))/σ, where σ=ph(βsing1=+0)1/2, 0.2 0.1 rms(ca) / rms(fzp) = 1.7 0 45.8 46.8 47.8 48.8 49.8 20090606 Based on the expected improvement, we will investigate further. The CA distribution uses all of the diode array and will require continuous alignment. xbsm status 20090626 Dan Peterson, Cornell page 18

The 4ns FADC readout is under development. Tests were made during 2 shifts of the May 2009 run. We uncovered 2 areas needing work: noise (related to the required speed), timing jitter. (The shape is due to the currently used amplifiers and shaping.) xbsm status 20090626 Dan Peterson, Cornell page 19

C-line, electrons D-line, positrons And finally, we are commissioning a second detector for the electron beam size. Modifications for the CHESS C-line are under-way. xbsm status 20090626 Dan Peterson, Cornell page 20