STOPOREN FACADE SYSTEM TIMBER WINDOW JOINERY - HEAD DETAIL

Similar documents
C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

STOLITE CONSTRUCTION SYSTEM EXT.CORNER - MANUF.STONE/STOLITE

The WANZ Guide to Window Installation

STOPOREN FACADE SYSTEM DRAWING REGISTER

System for 2+ Level Buildings

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

ALPINE TRAY. To get the best from this product please follow these recommendations.

E2 REDWAY FLASHINGS. Product. Scope. Appraisal No. 977 [2017] Appraisal No. 977 (2017) BRANZ Appraisals

The WANZ Guide to Window Installation. as described in E2/AS1 Amendment 7

How-To-build guide Garden shed

BBS Rusticated & Splaycut Cavity System

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.


Quantum Sliding Door. Features & Benefits. Trend Windows & Doors Design Manual Q-Mk-1 May 2014

4256HM JAMES HARDIE MONOLITHIC CLADDING

ADGV_001_FASTPOS. Date Jan 2013 Detail. Profile. Fastener Positioning Scale 1:20 Detail No. ADGV_ mm from top edge. 600mm MAX CTRS TIMBER STUDS

The Roofing Store TRS 9 35MM 78MM 150MM 78MM PRODUCT TECHNICAL DATA

A-lign Technical Manual

SPECIFICATION FOR. BRANZ Appraisal Certificate # 621 (2008)

THIS DRAWING IS INDICATIVE ONLY AND BY NO MEANS COMPREHENSIVE

UPVC Door Measuring Guide

Liniar Window. installation guide

JAMES HARDIE RIGID AIR BARRIERS

General Installation Guidelines

Timber Cavity Batten Technical Specifiction

Pipe penetration refer CT15. Viking CertainTeed Shingles General Roof details

A Shell construction

Acceptable Standards of Domestic Construction

9.0 PS Pacbld Sidings

PVCu FOLD & SLIDE DOOR OUTWARD OPENING

WINDOW JAMB FITTED SILL FLASHING GOES BEHIND SILL FIXING FIN AND AT LEAST 3 BRICK COURSES DOWN (LAP IF NECESSARY) WEEP HOLES ABOVE FLASHING

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

BARRIER SPECIFICATION & INSTALLATION GUIDE SEPTEMBER 2017

Installation instructions: Elements Vulcan+ Newport Hector Cladding

NEW HOME WARRANTY A REFERENCE GUIDE FOR TYPICAL WALL AND WINDOW DETAILS (RAINSCREEN SYSTEM) SHOWN AS FIBRE CEMENT CLADDING

NULINE PLUS WEATHERBOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 641 [2015]

ASS 70 FD folding/sliding door installation guide

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Picture Frame Method Revised 10/24/2016

STEEL FRAMING WEATHERBOARD SYSTEM

TEKTON WEATHERIZATION SYSTEM SPECIFICATION

Installation Guide. Evolve bi-fold. 8. Door restrictor- optional p9. 1. Before you start p2. 9. Adjustment. 2. Measuring and surveying p2

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016

ASS 70 FD folding / sliding door. Installation Guide

TYPICAL BARGE DETAIL - CROSS SECTION

ISSUE Erection Manual

DurasheetTM Fibre Cement

Extrusions GB-3-IN01. Updated: Scale: REV: - This Drawing is Protected by Copyright Altus NZ Ltd.

DURABARRIER RIGID SHEATHING / AIR BARRIER

UC SANTA CRUZ STANDARD PLASTER INSTALLATION AND DETAILS SEVERE WEATHER

SHADOWCLAD SPECIFICATION & INSTALLATION GUIDE

UNIT 5: EXTERIOR DOORS AND WINDOWS

PROTECTO SILL WINDOW SEALING SYSTEM. Product. Scope. Appraisal No. 444 [2017]

TRADE SILL FLASHING TAPE. Product. Scope. Appraisal No. 712 [2012] Appraisal No. 712 (2012) Amended 19 July BRANZ Appraisals

Dear Contractor, I am glad that you are interested in our window rebate program.

Installation Instructions

ThermoSpan EPS. Metalcraft COMMERCIAL ROOFING CREPS. Insulated Panel Systems DETAIL LIST

Window Frame Installation Instructions For Nail-on and Block Frames

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

A-lign Technical Manual

ES2. fully integrated screening system for bifold doors. load balancing technology. tough PVC-coated polyester mesh.

Timber to Timber - Timber to Concrete - Timber to Steel

The Leka System Installation Guide

How to operate (folding)

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Curtain Wall Installation Guide

Installation guide for 20/20

Gable HomeshedsTM INSTALLATION BEFORE YOU START TOOLS REQUIRED GUIDE LARGE SPAN. Council Approval. Before Starting

KS SERIES - VERTICAL INSTALLATION

Side Light Frame Pack Assembly Instructions

Before installation, check your local and state requirements for this type of install.

Finesse Profiles. Nailstrip

Door Canopy. PDL Building Products Industrial Parkway, N. Olmsted, OH Phone:

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

Side Light Frame Pack Assembly Instructions

MULTISLIDE DOORS INSTALLATION GUIDE & SITE PREPARATION

FD30 & FD60 FRAME & DOOR INSTALLATION GUIDE

CROSSBAR RAFTER ISOMETRIC

Integrity Polygon and Round Top Installation and Finishing Instructions

Note. Returns are blocks / mouldings that have finished sides suitable for doors and windows as shown below. Surround return.

Installation Guide. WarmCore. Folding Sliding door system. Glass Packing. Pre-Installation. Removing the Existing Door.

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Providing 3 Layers of Protection

DW HORIZONTAL INSTALLATION

maintenance-free free from painting easy to install Fixing Guide Cedral Lap

900 SERIES WALL PANELS

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS

SERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS

6x6 Shed Plans and Building Guide

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

Integrate the Window and WRB (1/2)

SovereignSeries. SovereignSeries

10x10 Shed Plans and Building Guide

Deluxe Cabana INSTALLATION INSTRUCTIONS. INSTALLATION Deluxe INSTRUCTIONS Cabana

In the 30-plus years that I ve been a remodeling contractor, I ve

DOOR INSTALLATION GUIDE WOOD FRAMING New Construction

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

A1-1 D O R S E T A V E N U E SITE PLAN SITE PLAN

Transcription:

INTERNAL LINING TIMBER LINTEL AS PER NZS 3604 FLEXIBLE FLASHING TAPE INSTALLED OVER AT AIRSEAL ON CORNERS PEF ROD GAP 7.5-8mm APPROX 35 RENDER 20mm DRAINED & VENTED CAVITY - BATTENS AT 300-600mm MAX.CTRS. PANEL FLASHING TAPE ONTO and OVER ALU.HEAD FLASHING STO upvc VENTED BASE CAP WITH MIN 5mm GAP ARCHITRAVE OR SLIMLINE DETAIL TIMBER WINDOW HEAD - PROFILE TO NZS 3610 10 10 5 MIN. 5mm GAP REQUIRED E2/AS1 COMPLIANT HEAD FLASHING, WITH 15 SLOPE AND 10mm MIN COVER TO JOINERY AND 10mm FLASHING OR PROPRIETARY STOPENDS TIMBER WINDOW JOINERY - HEAD DETAIL PP 870

10 FLEXIBLE FLASHING TAPE INSTALLED OVER WALL UNDERLAY AT CORNERS LINE OF JAMB FLASHING AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX TIMBER WINDOW SILL TO NZS 3610 CONTINUOUS PACKING E2/AS1 COMPLIANT SILL FLASHING WITH STOP-END, LAPPED UNDER JAMB FLASHING TURNED INTO FRAMING REVEALS AND TAPED AT CORNERS 25mm MIN. STO POREN PANEL END COVER WITH FLASHING TAPE STO upvc 6mm PREMESHED FINISHING EDGE MS SEALANT 20mm DRAINED & VENTED CAVITY - BATTENS AT 300-400mm MAX CTRS. RENDER JOINER TO EXTEND SILL WITH TIMBER FACING TO ACHEIVE MINIMUM 10mm COVER OVER SILL FLASHING (NOTE MEASURE ON SITE) TIMBER WINDOW JOINERY - SILL DETAIL PP 871

ARCHITRAVE OR SLIMLINE DETAIL INTERNAL LINING TURNED INTO FRAMING REVEALS AND TAPED AT CORNERS AIRSEAL GAP 10-12mm APPROX. AT JAMBS JAMB PACKER TO SUIT REBATE TIMBER JAMB - PROFILE TO NZS 3610 E2/AS1 COMPLIANT JAMB FLASHING SAWCUT AND SCREWED INTO JAMB WITH MS SEALANT OVER SCREWS PANEL POREN FIXING RENDER STO PREMESHED CORNER ANGLE LINE OF HEAD FLASHING LINE OF SILL FLASHING - LAPPED UNDER JAMB PACKING STO STICK ON JOINERY CONNECTOR ON JAMB FLASHING TIMBER WINDOW JOINERY - JAMB DETAIL PP 872

FLASHING TAPE 100mm MIN. UPSTAND TO JAMBS DOOR SILL TO NZS 3610 PROFILES TIMBER DOOR SILL TO NZS 3610 ON SUPPORT BAR STO upvc END CAP AND PREMESHED FINISHING EDGE AIR SEAL BOUNDARY JOISTS E2/AS1 COMPLIANT SILL FLASHING STOP ENDED AND LAPPED UNDER JAMB PACKERS 20mm CAVITY BATTENS @ 300-400mm MAX. CTRS MS SEALANT TURNED INTO FRAMING REVEALS DPC PANEL RENDER KEEP & BATTENS 20MM UP FROM BOTTOM EDGE OF CLADDING 50 STO upvc VENTED BASE CAP or FOOT TRAY TIMBER DOOR JOINERY - TIMBER FLOOR THRESHOLD DETAIL PP 873

FLASHING TAPE 100mm MIN.UPSTAND TO JAMBS TIMBER SILL TO NZS 3610 STO ADJUSTABLE FOOT TRAY ADAPTED TO SUIT 50 20mm REBATE WITH DPM, PEF ROD AND MS SEALANT AIRSEAL CONCRETE H3.2 TIMBER PACKER ON DPC TO SUPPORT SILL SECURED TO CONCRETE SLAB WITH MASONRY ANCHORS TIMBER DOOR JOINERY - CONC. FLOOR THRESHOLD DETAIL PP 874

5 20mm DRAINED CAVITY PANEL RENDER INTERIOR LINING TIMBER LINTEL AS PER NZS 3604 AIRSEAL OVER PEF ROD GAP 7.5-8mm APPROX 50mm 35mm MIN. 10 FLASHING TAPE ONTO STO upvc VENTED BASE CAP MIN. 5mm GAP REQUIRED ALUMINUM WINDOW HEAD FLASHING MIN.15 SLOPE AND 10mm COVER AT WINDOW HEAD SEALANT REQUIRED FOR VERY HIGH AND EXTRA HIGH WIND ZONES PROPRIETARY NK PVCu WINDOW 1. IN EXTRA HIGH WIND ZONES INCREASE FLASHING UPSTAND TO 60mm AND USE A RIGID UNDERLAY 2. 10mm MINIMUM HEAD FLASHING OR PROPRIETARY STOPENDS REQUIRED NK PVCu JOINERY - HEAD DETAIL PP 875

PROPRIETARY NK PVCu WINDOW RSEAL ON PEF ROD GAP 7.5-8mm APPROX. RETURNED INTO OPENINGS & FLASHING PE CONTINUOUS ALONG LL MIN 100mm UP JAMBS & 50mm ONTO FACE OF TIMBER FRAMING TO NZS 3604 INTERIOR LINING FRAME BLOCK MS SEALANT STO upvc SILL FLASHING FOR NK PVCu JOINERY STO PREMESHED upvc CNR JOINERY SUPPORT BAR REQUIRE FOR OPENINGS OVER 600mm 20mm DRAINED CAVITY PANEL RENDER NK PVCu JOINERY - SILL DETAIL PP 876

FLASHING TAPE (100mm UP JAMBS) AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX. H1.2 PACKER TO SUPPORT JOINERY STOTHERM 20mm VH CAVITY BATTEN LINE OF HEAD FLASHING OVER WITH STOPEND RENDER STO upvc JAMB FLASHING GLUE OR BED FLASHING IN PLACE BEFORE RENDERING PROPRIETARY NK PVCu WINDOW MS SEALANT TO JAMBS STO upvc PRE MESHED ANGLE NK PVCu JOINERY - JAMB DETAIL PP 877

20mm DRAINED CAVITY PANEL RENDER INTERIOR LINING TIMBER LINTEL AS PER NZS 3604 AIRSEAL OVER PEF ROD GAP 7.5-8mm APPROX 5 PROPRIETARY TAPE OVER HEAD FLASHING SUPPLIED AND INSTALLED BY FLASHMAN CONTRACTOR upvc VENTED BASE TRAY 25mm MIN. FROM OUTSIDE OF FRAMING TO BACK OF WINDOW FLANGE 25 MIN. 5mm GAP REQUIRED FLASHMAN EXTRUDED ALUMINIUM ONE PIECE CAVITY CLOSURE AND HEAD FLASHING WITH STOP END (SHOWN DASHED) SEALANT REQUIRED FOR VERY HIGH AND EXTRA HIGH WIND ZONES ALUMINIUM WINDOW JOINERY FLASHMAN HEAD FLASHING PP 878

FLASHMAN ALUMINIUM MITRE SOAKER SUPPLIED BY FLASHMAN INSTALLED BY BUILDER AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX. RETURNED INTO OPENINGS & FLASHING TAPE CONTINUOUS ALONG SILL MIN 100mm UP JAMBS & 50mm ONTO FACE OF WALL UNDERLAY 14 GAUGE HOT DIP GALV.(316SS WHERE REQ.) S.T.H.C SCREWS @ 600mm CTRS. WITH 65mm MIN. FRAME PENETRATION. SUPPLIED BY FLASHMAN TIMBER FRAMING TO NZS 3604 25 25mm MIN. FROM OUTSIDE FACE OF THE FRAMING LINE TO THE BACK OF WINDOW FLANGE SUPPORT PACKER FLASHMAN BACK PLATE - SHOWN DASHED FLASHMAN EXTRUDED ALU.EURO SILL WITH END CAP - SHOWN DASHED ALT.METRO SILL - SHOWN DASHED 8 STO STICK ON JOINERY CONNECTOR 8mm MIN. H3.1 PACKER SUPPLIED AND INSTALLED BY FLASHMAN 20mm DRAINED CAVITY POREN FIXING RENDER FLASHMAN SILL FLASHING PP 879

INTERNAL LINING TIMBER FRAMING TO NZS3604 AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX. FLASHING TAPE (100mm UP JAMBS) H1.2 PACKER TO SUPPORT JOINERY INSTALLED AS PER E2/AS1 ALUMINIUM WINDOW JOINERY 25 25mm MIN. FROM OUTSIDE FACE OF FRAMING TO BACK OF WINDOW FLANGE DO NOT FIX THROUGH FLASHING H3.1 PACKER SUPPLIED AND INSTALLED BY FLASHMAN CONTRACTOR FLASHMAN EXTRUDED ALUM. JAMB FLASHING upvc STICK ON JOINERY CONNECTOR STO upvc END CAP TO END OF PANEL LINE OF ALT. METRO SILL BELOW - SHOWN DASHED LINE OF FLASHMAN EURO SILL FLASHING FLASHMAN JAMB FLASHING PP 880

INSTALLED AS PER E2/AS1 20mm DRAINED CAVITY PANEL INTERIOR LINING TIMBER LINTEL AS PER NZS 3604 10 PANEL RENDER STO CAVITY JAMB FLASHING STOPENDS FLASHING TAPE ONTO STO upvc VENTED BASE CAP AIRSEAL OVER PEF ROD GAP 7.5-8mm APPROX 1. IN EXTRA HIGH WIND ZONES INCREASE FLASHING UPSTAND TO 60mm AND USE A RIGID UNDERLAY 2. 10mm MINIMUM HEAD FLASHING OR PROPRIETARY STOP ENDS REQUIRED 5 MIN. 5mm GAP REQUIRED ALUMINIUM WINDOW HEAD FLASHING MIN.15 SLOPE AND 10mm COVER AT WINDOW HEAD SEALANT REQUIRED FOR VERY HIGH AND EXTRA HIGH WIND ZONES PROPRIETARY HOMERIT PVC WINDOW JOINERY HOMERIT PVC JOINERY - HEAD DETAIL PP 881

AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX. RETURNED INTO OPENINGS & FLASHING TAPE CONTINUOUS ALONG SILL MIN 100mm UP JAMBS & 50mm ONTO FACE OF AS PER E2/AS1 TIMBER FRAMING TO NZS 3604 INTERIOR LINING 5 PROPRIETARY HOMERIT PVC WINDOW JOINERY JOINERY SUPPORT BAR REQUIRE FOR OPENINGS OVER 600mm MS SEALANT 5mm GAP BETWEEN JOINERY & RENDER STO upvc ADJUSTABLE CNR STO upvc CAVITY FACE FIXED SILL & JAMB FLASHING 20mm DRAINED CAVITY PANEL POREN FIXING RENDER HOMERIT PVC JOINERY - SILL DETAIL PP 882

INTERNAL LINING TIMBER FRAMING TO NZS3604 LAPPED & STAPLED ONTO INSIDE FRAME COVERED WITH FLASHING TAPE AS PER E2/AS1 AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX. FLASHING TAPE AS PER E2/AS1 H1.2 PACKER TO SUPPORT JOINERY STOTHERM 20mm VH CAVITY BATTENS PANEL FIXING RENDER PROPRIETARY HOMERIT PVC WINDOW JOINERY MS SEALANT STO upvc CAVITY JAMB FLASHING STO upvc PRE MESHED ADJUSTABLE CNR HOMERIT PVC JOINERY - JAMB DETAIL PP 883