INTERNAL LINING TIMBER LINTEL AS PER NZS 3604 FLEXIBLE FLASHING TAPE INSTALLED OVER AT AIRSEAL ON CORNERS PEF ROD GAP 7.5-8mm APPROX 35 RENDER 20mm DRAINED & VENTED CAVITY - BATTENS AT 300-600mm MAX.CTRS. PANEL FLASHING TAPE ONTO and OVER ALU.HEAD FLASHING STO upvc VENTED BASE CAP WITH MIN 5mm GAP ARCHITRAVE OR SLIMLINE DETAIL TIMBER WINDOW HEAD - PROFILE TO NZS 3610 10 10 5 MIN. 5mm GAP REQUIRED E2/AS1 COMPLIANT HEAD FLASHING, WITH 15 SLOPE AND 10mm MIN COVER TO JOINERY AND 10mm FLASHING OR PROPRIETARY STOPENDS TIMBER WINDOW JOINERY - HEAD DETAIL PP 870
10 FLEXIBLE FLASHING TAPE INSTALLED OVER WALL UNDERLAY AT CORNERS LINE OF JAMB FLASHING AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX TIMBER WINDOW SILL TO NZS 3610 CONTINUOUS PACKING E2/AS1 COMPLIANT SILL FLASHING WITH STOP-END, LAPPED UNDER JAMB FLASHING TURNED INTO FRAMING REVEALS AND TAPED AT CORNERS 25mm MIN. STO POREN PANEL END COVER WITH FLASHING TAPE STO upvc 6mm PREMESHED FINISHING EDGE MS SEALANT 20mm DRAINED & VENTED CAVITY - BATTENS AT 300-400mm MAX CTRS. RENDER JOINER TO EXTEND SILL WITH TIMBER FACING TO ACHEIVE MINIMUM 10mm COVER OVER SILL FLASHING (NOTE MEASURE ON SITE) TIMBER WINDOW JOINERY - SILL DETAIL PP 871
ARCHITRAVE OR SLIMLINE DETAIL INTERNAL LINING TURNED INTO FRAMING REVEALS AND TAPED AT CORNERS AIRSEAL GAP 10-12mm APPROX. AT JAMBS JAMB PACKER TO SUIT REBATE TIMBER JAMB - PROFILE TO NZS 3610 E2/AS1 COMPLIANT JAMB FLASHING SAWCUT AND SCREWED INTO JAMB WITH MS SEALANT OVER SCREWS PANEL POREN FIXING RENDER STO PREMESHED CORNER ANGLE LINE OF HEAD FLASHING LINE OF SILL FLASHING - LAPPED UNDER JAMB PACKING STO STICK ON JOINERY CONNECTOR ON JAMB FLASHING TIMBER WINDOW JOINERY - JAMB DETAIL PP 872
FLASHING TAPE 100mm MIN. UPSTAND TO JAMBS DOOR SILL TO NZS 3610 PROFILES TIMBER DOOR SILL TO NZS 3610 ON SUPPORT BAR STO upvc END CAP AND PREMESHED FINISHING EDGE AIR SEAL BOUNDARY JOISTS E2/AS1 COMPLIANT SILL FLASHING STOP ENDED AND LAPPED UNDER JAMB PACKERS 20mm CAVITY BATTENS @ 300-400mm MAX. CTRS MS SEALANT TURNED INTO FRAMING REVEALS DPC PANEL RENDER KEEP & BATTENS 20MM UP FROM BOTTOM EDGE OF CLADDING 50 STO upvc VENTED BASE CAP or FOOT TRAY TIMBER DOOR JOINERY - TIMBER FLOOR THRESHOLD DETAIL PP 873
FLASHING TAPE 100mm MIN.UPSTAND TO JAMBS TIMBER SILL TO NZS 3610 STO ADJUSTABLE FOOT TRAY ADAPTED TO SUIT 50 20mm REBATE WITH DPM, PEF ROD AND MS SEALANT AIRSEAL CONCRETE H3.2 TIMBER PACKER ON DPC TO SUPPORT SILL SECURED TO CONCRETE SLAB WITH MASONRY ANCHORS TIMBER DOOR JOINERY - CONC. FLOOR THRESHOLD DETAIL PP 874
5 20mm DRAINED CAVITY PANEL RENDER INTERIOR LINING TIMBER LINTEL AS PER NZS 3604 AIRSEAL OVER PEF ROD GAP 7.5-8mm APPROX 50mm 35mm MIN. 10 FLASHING TAPE ONTO STO upvc VENTED BASE CAP MIN. 5mm GAP REQUIRED ALUMINUM WINDOW HEAD FLASHING MIN.15 SLOPE AND 10mm COVER AT WINDOW HEAD SEALANT REQUIRED FOR VERY HIGH AND EXTRA HIGH WIND ZONES PROPRIETARY NK PVCu WINDOW 1. IN EXTRA HIGH WIND ZONES INCREASE FLASHING UPSTAND TO 60mm AND USE A RIGID UNDERLAY 2. 10mm MINIMUM HEAD FLASHING OR PROPRIETARY STOPENDS REQUIRED NK PVCu JOINERY - HEAD DETAIL PP 875
PROPRIETARY NK PVCu WINDOW RSEAL ON PEF ROD GAP 7.5-8mm APPROX. RETURNED INTO OPENINGS & FLASHING PE CONTINUOUS ALONG LL MIN 100mm UP JAMBS & 50mm ONTO FACE OF TIMBER FRAMING TO NZS 3604 INTERIOR LINING FRAME BLOCK MS SEALANT STO upvc SILL FLASHING FOR NK PVCu JOINERY STO PREMESHED upvc CNR JOINERY SUPPORT BAR REQUIRE FOR OPENINGS OVER 600mm 20mm DRAINED CAVITY PANEL RENDER NK PVCu JOINERY - SILL DETAIL PP 876
FLASHING TAPE (100mm UP JAMBS) AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX. H1.2 PACKER TO SUPPORT JOINERY STOTHERM 20mm VH CAVITY BATTEN LINE OF HEAD FLASHING OVER WITH STOPEND RENDER STO upvc JAMB FLASHING GLUE OR BED FLASHING IN PLACE BEFORE RENDERING PROPRIETARY NK PVCu WINDOW MS SEALANT TO JAMBS STO upvc PRE MESHED ANGLE NK PVCu JOINERY - JAMB DETAIL PP 877
20mm DRAINED CAVITY PANEL RENDER INTERIOR LINING TIMBER LINTEL AS PER NZS 3604 AIRSEAL OVER PEF ROD GAP 7.5-8mm APPROX 5 PROPRIETARY TAPE OVER HEAD FLASHING SUPPLIED AND INSTALLED BY FLASHMAN CONTRACTOR upvc VENTED BASE TRAY 25mm MIN. FROM OUTSIDE OF FRAMING TO BACK OF WINDOW FLANGE 25 MIN. 5mm GAP REQUIRED FLASHMAN EXTRUDED ALUMINIUM ONE PIECE CAVITY CLOSURE AND HEAD FLASHING WITH STOP END (SHOWN DASHED) SEALANT REQUIRED FOR VERY HIGH AND EXTRA HIGH WIND ZONES ALUMINIUM WINDOW JOINERY FLASHMAN HEAD FLASHING PP 878
FLASHMAN ALUMINIUM MITRE SOAKER SUPPLIED BY FLASHMAN INSTALLED BY BUILDER AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX. RETURNED INTO OPENINGS & FLASHING TAPE CONTINUOUS ALONG SILL MIN 100mm UP JAMBS & 50mm ONTO FACE OF WALL UNDERLAY 14 GAUGE HOT DIP GALV.(316SS WHERE REQ.) S.T.H.C SCREWS @ 600mm CTRS. WITH 65mm MIN. FRAME PENETRATION. SUPPLIED BY FLASHMAN TIMBER FRAMING TO NZS 3604 25 25mm MIN. FROM OUTSIDE FACE OF THE FRAMING LINE TO THE BACK OF WINDOW FLANGE SUPPORT PACKER FLASHMAN BACK PLATE - SHOWN DASHED FLASHMAN EXTRUDED ALU.EURO SILL WITH END CAP - SHOWN DASHED ALT.METRO SILL - SHOWN DASHED 8 STO STICK ON JOINERY CONNECTOR 8mm MIN. H3.1 PACKER SUPPLIED AND INSTALLED BY FLASHMAN 20mm DRAINED CAVITY POREN FIXING RENDER FLASHMAN SILL FLASHING PP 879
INTERNAL LINING TIMBER FRAMING TO NZS3604 AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX. FLASHING TAPE (100mm UP JAMBS) H1.2 PACKER TO SUPPORT JOINERY INSTALLED AS PER E2/AS1 ALUMINIUM WINDOW JOINERY 25 25mm MIN. FROM OUTSIDE FACE OF FRAMING TO BACK OF WINDOW FLANGE DO NOT FIX THROUGH FLASHING H3.1 PACKER SUPPLIED AND INSTALLED BY FLASHMAN CONTRACTOR FLASHMAN EXTRUDED ALUM. JAMB FLASHING upvc STICK ON JOINERY CONNECTOR STO upvc END CAP TO END OF PANEL LINE OF ALT. METRO SILL BELOW - SHOWN DASHED LINE OF FLASHMAN EURO SILL FLASHING FLASHMAN JAMB FLASHING PP 880
INSTALLED AS PER E2/AS1 20mm DRAINED CAVITY PANEL INTERIOR LINING TIMBER LINTEL AS PER NZS 3604 10 PANEL RENDER STO CAVITY JAMB FLASHING STOPENDS FLASHING TAPE ONTO STO upvc VENTED BASE CAP AIRSEAL OVER PEF ROD GAP 7.5-8mm APPROX 1. IN EXTRA HIGH WIND ZONES INCREASE FLASHING UPSTAND TO 60mm AND USE A RIGID UNDERLAY 2. 10mm MINIMUM HEAD FLASHING OR PROPRIETARY STOP ENDS REQUIRED 5 MIN. 5mm GAP REQUIRED ALUMINIUM WINDOW HEAD FLASHING MIN.15 SLOPE AND 10mm COVER AT WINDOW HEAD SEALANT REQUIRED FOR VERY HIGH AND EXTRA HIGH WIND ZONES PROPRIETARY HOMERIT PVC WINDOW JOINERY HOMERIT PVC JOINERY - HEAD DETAIL PP 881
AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX. RETURNED INTO OPENINGS & FLASHING TAPE CONTINUOUS ALONG SILL MIN 100mm UP JAMBS & 50mm ONTO FACE OF AS PER E2/AS1 TIMBER FRAMING TO NZS 3604 INTERIOR LINING 5 PROPRIETARY HOMERIT PVC WINDOW JOINERY JOINERY SUPPORT BAR REQUIRE FOR OPENINGS OVER 600mm MS SEALANT 5mm GAP BETWEEN JOINERY & RENDER STO upvc ADJUSTABLE CNR STO upvc CAVITY FACE FIXED SILL & JAMB FLASHING 20mm DRAINED CAVITY PANEL POREN FIXING RENDER HOMERIT PVC JOINERY - SILL DETAIL PP 882
INTERNAL LINING TIMBER FRAMING TO NZS3604 LAPPED & STAPLED ONTO INSIDE FRAME COVERED WITH FLASHING TAPE AS PER E2/AS1 AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX. FLASHING TAPE AS PER E2/AS1 H1.2 PACKER TO SUPPORT JOINERY STOTHERM 20mm VH CAVITY BATTENS PANEL FIXING RENDER PROPRIETARY HOMERIT PVC WINDOW JOINERY MS SEALANT STO upvc CAVITY JAMB FLASHING STO upvc PRE MESHED ADJUSTABLE CNR HOMERIT PVC JOINERY - JAMB DETAIL PP 883