76 www.sihga.com, Phone +43 (0) 7612/ 74 370-0 ZaFix support foot STZ For extra-fast assembly ZaFix support foot STZ with perfect structural wood protection ensures a durable and long-lived wood connection. Optimum splash-proof protection is ensured by choosing the suitable model size (we recommend a minimum distance of 160 mm between the wooden pillar and the finished floor). The sealing bush made of stainless high-grade steel looks elegant and at the same time hides the technically perfect height adjustment which can also be adjusted when the support foot has been already mounted. An integrated sliding ring for the distribution of pressure permits smooth height adjustment even under full pressure. The double standing tube of ZaFix support foot STZ sustains an above-average compressive stress and at the same time prevents early buckling out which may occur in customary support feet with threaded rods. The expansion bolt of the ZaFix support foot STZ presses its specially formed spikes into the wooden pillar without splitting it. This unique patent permits extra-fast assembly and an invisible force-fit tensile connection.
77 ZaFix STZ accessories ZaFix Lewis drill available with diameters of 30 and 40 mm and a total length of 235 mm. The geometry with a retractable tip is especially adapted for drilling in cross-grained wood. ZaFix For professional fastening of ZaFix support feet STZ we recommend BeziFix anchors which permit very small edge distances in the foundation and are screwed into the drill hole without dowels. As force is not transmitted by expansion, but through the whole surface of the flanks of the screw threads, it is sufficient to fasten the screw hand-tight to ensure full load transmission (page 92 of this catalogue).
78 www.sihga.com, Phone +43 (0) 7612/ 74 370-0 ZaFix STZ assembly Simple and easy application without slitting all you need is a drill hole by hand or by a joinery machine (Ø 30 mm or 40 mm) Then simply put the ZaFix support foot STZ into the drill hole together with the whole expansion bolt. Now only six more turns on the top nut are necessary to press the specially formed spikes into the wooden pillar- FINISHED! The height of this joint can be adjusted at any time. When the support foot has already been mounted, turn the stainless-steel sealing bush down, adjust the height and turn the stainless-steel sealing bush up again.
79 STZ 211 STZ 221 STZ 310 STZ 311 ZaFix STZ 320 STZ 321 Before construction, all calculations must be checked and cleared by the responsible planner. Data valid except for typographical and printing errors. SIHGA IdeFix Characteristic values ÖNORM B 4 objektpack STZ Height [mm] Pressure Tension Art. No. PU Type From To Rc,k Rt,k Pressure Tension 35909 10 STZ 211 120 160 44,63-35919 10 STZ 221 120 160 44,63-36009 10 STZ 310 120 160 70,42-36019 10 STZ 311 120 160 70,42-36059 10 STZ 320 120 160 70,42-36069 10 STZ 321 120 160 70,42-20,35-20,35 - Characteristic values for dimensioning according to EC 5 resp. DIN 1052:2008 *ÖNORM B 4 Characteristic values for strength class C 24 (rk 350 kg/m³) (withdrawn) The pressure values of the support feet have been dimensioned according to DIN 180-2 resp. 1052:2008 Ø 12 20 6 85 Ø 13 160 Ø 11 5
www.sihga.com, Phone +43 (0) 7612/ 74 370-0 STZ 330 125-160 mm STZ 331 125-160 mm STZ 332 165-200 mm 45 45 STZ 333 205-240 mm STZ 336 160-195 mm STZ 338 160-195 mm Before construction, all calculations must be checked and cleared by the responsible planner. Data valid except for typographical and printing errors. SIHGA IdeFix Characteristic values ÖNORM B 4 objektpack STZ Height [mm] Pressure Tension Art. No. PU Type From To Rc,k Rt,k Pressure Tension 36109 10 STZ 330 125 160 70,42 8,98 36119 10 STZ 331 125 160 70,42 8,98 36129 10 STZ 332 165 200 57,38 8,98 36139 10 STZ 333 205 240 46,26 8,98 36169 10 STZ 336 160 195 59,20 8,98 36189 10 STZ 338 160 195 59,20 8,98 32,10 3,95 32,10 3,95 26,16 3,95 21,08 3,95 26,99 3,95 26,99 3,95 Characteristic values for dimensioning according to EC 5 resp. DIN 1052:2008 *ÖNORM B 4 Characteristic values for strength class C 24 (rk 350 kg/m³) (withdrawn) The pressure values of the support feet have been dimensioned according to DIN 180-2 resp. 1052:2008 30 20 110 Ø 13 6 Ø 11 160 5 Ø 30 200
81 ZaFix STZ 742 165-210 mm STZ 743 2-260 mm STZ 744 265-310 mm Before construction, all calculations must be checked and cleared by the responsible planner. Data valid except for typographical and printing errors. SIHGA IdeFix Characteristic values ÖNORM B 4 objektpack STZ Height [mm] Pressure Tension Art. No. PU Type From To Rc,k Rt,k 36529 5 STZ 742 165 210 162,93 10,57 36539 5 STZ 743 2 260 140,08 10,57 36549 5 STZ 744 265 310 117,72 10,57 Pressure Tension 74,27 4,65 63,85 4,65 53,66 4,65 Characteristic values for dimensioning according to EC 5 resp. DIN 1052:2008 *ÖNORM B 4 Characteristic values for strength class C 24 (rk 350 kg/m³) (withdrawn) The pressure values of the support feet have been dimensioned according to DIN 180-2 resp. 1052:2008 40 20 140 8 Ø 13 160 8