Installation Guide Tilt/Swivel Flush Mount for 23'' and Larger Flat Panel Displays

Similar documents
Installation Guide. Cabinet Surface Mount for Single Display

Installation Guide Philips MP40/50/60/70 Installation Kit for Penlon Anesthesia Machine

Installation Guide Mounting Kit Philips MP70/EGM/FMS on Dräger Fabius Tiro

Installation Guide Philips MP80/90 Installation Kit for Penlon Anesthesia Machine

Installation Guide VHM Arm with 8'' Extension/Swivel Stop & 6'' Riser for Mounting Philips MP90 on Dräger Apollo

Installation Guide Philips IntelliVue MP20/30/40/50/60/70 MX400/450/500/550/600/700/800 M-Series Arm Mounting Kit for Dräger Primus Anesthesia Machine

Installation Guide Installation Kit for Mounting Philips MP20/30/40/50 on Datex-Ohmeda Aisys Anesthesia Machine

GEMSIT Tram-rac 4A Module Housing Installation Kit

Installation Guide Installation Kit for Mounting Philips MP20/30/40/50/60/70 on GE Healthcare Aisys Carestation

GCX Mounting Assembly Installation Guide. Drager Narcomed GS Anesthesia Machines with Philips MP60/70 IntelliVue Patient Monitor Kit

INSTALLATION INSTRUCTIONS GRILLE GUARD RAM 1500 PART # 5058/5058-2

Installation and Assembly: Flat \ Tilt Wall Mount for VESA 400x400

F l a t S c r e e n A R M S I n s t a l l a t i o n

Medium Flat Panel Dual Swing Arm Wall Mount JWD-V

INSTALLATION MANUAL FRONT. See pages 2 and 3 of this manual for configuration options. Level of Difficulty. Product Photo (center section only)

Installation Guide. Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

Installation and Assembly - Articulating Swivel Double-Arm for 42" - 71" Plasma Screens

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

Speaker Mount Center Channel Speaker Adapter (PAC-301)

INSTALLATION INSTRUCTIONS Small Flat Panel FMA Pivot Arrays Models: FMA-220 and FMA-320

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

INSTALLATION INSTRUCTIONS

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

INSTALLATION INSTRUCTIONS DODGE RAM 2 & 4WD 1500 PART # P5058

Flat Panel Dual Swing Arm Wall Mount (FWD-110) MSP-SA

INSTALLATION INSTRUCTIONS Horizontal And Vertical Table Stands and Accessories Model: KTP-Series

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

INSTALLATION INSTRUCTIONS Horizontal And Vertical Table Stands and Accessories Model: KTP-Series

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

3 wide x 3 deep Video Wall Display Installation Guide

Installation and Assembly: Flat-Panel Base Lock-Down Kit for Samsung Display Models

4 BAY Low Profile - SINGLE XL DISPLAY WALL MOUNT CABINET

User and Installation Manual. For Tandem Arm and Slim Line Models. Tandem Arm. Slim Line

(6) Plastic Retainers. Passenger/Right. Passenger/Right Support Brackets

INSTALLATION INSTRUCTIONS GRILLE GUARD 09-ON DODGE RAM PART #

Installation and Assembly - Desktop Swivel Mount For 32" - 55" Flat Panel Display

TYGER GUARD. Parts List BEFORE INSTALLATION WARNING TG-GD6D /7. Tyger Guard. Tube Brackets (Bull Bar) passenger or driver side

MPA-9000 Universal Ceiling Projector Mount Kit

ASSEMBLY AND ADJUSTMENT

INSTITUTIONAL LIFEGUARD STAND

INSTALLATION INSTRUCTIONS CONTOURED LIGHT BAR APPLICATION: CHEVY EQUINOX/ GMC TERRAIN PART NUMBERS: ,

CAB END BEDTRAX (SIDE VIEW)

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

SmartView Mounting Frame 3 Wide x 3 Deep Video Wall Display Installation Guide

O-Sullivan King 4 Poster Bed O-Sullivan Queen 4 Poster Bed Parts and Hardware List

INSTALLATION GUIDE Ceiling TV Mount MHP-52

INSTALLATION INSTRUCTIONS GRILLE GUARD FORD ESCAPE

Installation Instruction

4 BAY Low Profile-Dual Displays WALL MOUNT CABINET

MODULAR BUMPER INSTALLATION MANUAL

1. TOOLS + MATERIALS REQUIRED

4 BAY Low Profile WALL MOUNT CABINET

EDGE2 DUAL MONITOR ARM

INSTALLATION INSTRUCTIONS / DODGE RAM CREW CAB 2500/3500

TITAN2-EDGE Public Access Computer Station Dual Track

INSTALLATION INSTRUCTIONS SLBU / SLMU UNIVERSAL INTERFACE BRACKETS

INSTALLATION INSTRUCTIONS

Queen Wingback Bed King Wingback Bed

INSTALLATION INSTRUCTIONS GRILLE GUARD CHEVY TAHOE / AVALANCHE 1500/ SUBURBAN 1500 PART # /502795

Installation and Assembly: Wallmount for CPA100 and Whiteboard

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

(W) INSTALLATION INSTRUCTIONS 3" ROUND & 4" OVAL SIDEBAR (90-DEG BENT END) DODGE RAM 1500 QUAD CAB PART #DZ /DZ /DZ /DZ

40670 Transit Connect/NV200/City Express/ProMaster City Partition

INSTALLATION INSTRUCTIONS

Model D3348 Extension Block Kit Instruction Sheet

Vintage Kitchen in Pink Assembly Instructions

INSTALLATION INSTRUCTIONS 3"/4 BENT END SIDEBARS FORD F-150 SUPERCREW PART # DZ /DZ

B B B

STEP 1 STEP 2 LEVELER KIT OPTION MOBILE CASTER KIT OPTION

Toyota Extend-A-Fender Fender Flares Set of 4

INSTALLATION INSTRUCTIONS 6 OVAL BENT END SIDEBARS DODGE RAM 1500, CREW CAB PART#: /241533B

Mobile Cart for Flat Panel Display MSP-SPTC42 (PTC-2000 Series)

PART #MSP-DCCST Flat Panel Tilt Mount

Passenger/Right Center and Rear Support Brackets. Driver/Left Center and

Truss Pitch-Adjustable (TPP) Mount

Installation and Assembly: LCD UPRIGHT STAND FOR PEDESTAL CABINETS

MSP-DCCPGTU Large Screen Tilt Display Mount

CRITICAL INFORMATION:

This manual will aid in the assembly of the FireBall V90 and FireBall X90. The assembly of both machines will be identical, unless specified.

PFW 6851 Display Wall Mount, Turn & Tilt 80 kg INSTALLATION INSTRUCTIONS

NEC Display Solutions of America, Inc.

ASSEMBLY AND ADJUSTMENT

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

10-1.5mm x 40mm Hex Bolt 1 Driver/Left Front Inner Support Bracket (2WD & 4WD Vehicles W/O Skid Plate Only) 2

Driver/Left Top. Support Bracket

VIEWPOINT ALUMINUM RUNNING BOARD TOYOTA RAV4

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set

Installation and Assembly: Flat Panel Pull-out Swivel Wall Mount

Desk/Wall-Mount Rack

USSC LLC 4 ONE LLC FIELD MODIFICATION INSTRUCTIONS

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 65" Plasma Screens. Models: PLAV70, PLAV70-S

Medium Flat Panel Universal Interface Bracket (MSB-V)

6 BAY AV CREDENZA WITH DUAL DISPLAY MOUNT

Model MSPPWRTW Large Flat Panel Single Arm Wall Mount

Steele TV Stand Stock # BH

LCD TV WALL MOUNT INSTALLATION INSTRUCTIONS. DUAL Swing Arm (RFWD-110) WARNING

LEG CURL IP-S1315 INSTALLATION INSTRUCTIONS

Transcription:

Installation Guide Tilt/Swivel Flush Mount for 23'' and Larger Flat Panel isplays WRNING: This mounting system has a weight limit of 100 lbs [45.36 kg]. o not mount a display weighing more than 100 lbs [45.36 kg] on this Tilt/Swivel Flush Mount. The purpose of this guide is to describe installation of the mount and mounting a display on the mount. Parts Reference The following parts and hardware are included in this installation kit (hardware not shown: Item # escription Qty 1 Tilt/Swivel Flush Mount ssembly 1 2 Mounting dapter 1 3 M4 x 14 mm Pan Head Machine Screw (PHMS) 4 4 M4 x 12 mm PHMS 4 5 M4 x 10 mm PHMS 4 6 M6 x 16 mm Socket Head Machine Screw (SHS) 4 7 M6 x 14 mm SHS 4 8 5/16-18 Lock Nut, Nylon 4 9 Washer,.750 x.320 x.050 4 10 1/8'' Hex Wrench 1 11 3/16'' Hex Wrench 1 12 1/2'' Socket Wrench 1 1 2 Tools Required Phillips screwdriver (not provided) 1/8'' hex wrench (provided) 3/16'' hex wrenches (provided) 1/2'' socket wrench (provided). U-FLP-0010-01 Rev 9/08/08 GX orp. Page 1 of 6

Mounting Flush Mount in hannel 1. Guide hannel Slide (rear of Mount) into top of channel and move to desired mounting position. Using the 1/8'' hex wrench provided, tighten four (4) socket set screws (below right) to secure Mount in hannel. Tighten Set Screws Tighten Set Screws Existing hannel U-FLP-0010-01 Rev 9/08/08 GX orp. Page 2 of 6

Mounting a 23'' to 31'' isplay Installation Note: The display must be equipped with a 100 x 100 mm or 100 x 200 mm VES mounting pattern for attachment to the Tilt/Swivel Flush Mount. M4 pan head machine screws (PHMS) are included for different depths of threaded inserts in the VES mounting pattern. 1. etermine required length of M4 mounting screw for fastening display to Mount. 2. Thread two (2) M4 PHMS into the upper two (2) mounting holes of the VES mounting pattern (rear of display), leaving 5mm of thread exposed (upper illustration). Hang display on Mount by guiding these two (2) screws into the slots on top of the Mount. 100 x 200 mm Mounting Pattern 100 x 100 mm Mounting Pattern M4 PHMS (2) with 5 mm Exposed Thread Upper Slots 3. Thread two (2) M4 PHMS into the lower mounting holes and tighten all four (4) mounting screws. 100 x 100 mm Mounting Pattern 100 x 200 mm Mounting Pattern M4 PHMS (2) M4 PHMS (2) U-FLP-0010-01 Rev 9/08/08 GX orp. Page 3 of 6

Mounting a 31'' (iagonal) or Larger isplay Installation Note: The Mounting dapter (provided) must be used when mounting larger displays on the Tilt/Swivel Mount. M6 socket head cap screws (SHS) and M4 pan head machine screws (PHMS) are included for different depths of threaded inserts on the rear of the display. Various possible mounting patterns are shown below. WRNING: The Mounting dapter must be attached to the Tilt/Swivel Flush Mount with four (4) slots oriented upward as shown in below. Failure to attach the Mounting dapter with slots up could cause the display to fall off the Mount. The following table lists available mounting patterns and screw size required for each mounting pattern. See Parts Reference on page 1 for screw sizes included in this installation kit. Mounting patterns are identified below right. Pattern Size of Mounting Pattern Screw Size 100 mm x 300 mm M4 PHMS WRNING: Slots Must Face Upward 100 mm x 300 mm M6 SHS 200 mm x 200 mm M6 SHS 200 mm x 400 mm M6 SHS 1. Using the 1/2'' wrench provided, fasten the Mounting dapter to the Tilt/Swivel Mount with four (4) 5/16-18 Lock Nuts and 0.75 x 0.32 Washers as shown in illustration below. WRNING: Slots Must Face Upward 0.75 x 0.32 Washers (4) Mounting dapter 5/16-18 Lock Nuts (4) U-FLP-0010-01 Rev 9/08/08 GX orp. Page 4 of 6

2. etermine required mounting screw (M6 SHS or M4 PHMS) for fastening display to Mounting dapter. 3. Thread four (4) screws' into the 4-hole mounting pattern on the rear of display, leaving 5mm of thread exposed. Hang display on Mount by guiding screws into the corresponding slots and keyholes in the Mounting dapter. 4. Using the 3/16'' hex wrench (provided) for socket head screws or Phillips screwdriver (not provided) for pan head screws, tighten all mounting screws. Hang Upper SHS (2) in Slots or Keyholes Insert Lower SHS (2) in Keyholes djusting Tilt 1. Using a 1/2'' wrench on each end of the bolt, loosen the rear tilt bolt and tilt display to desired position. Note: It may be necessary to loosen the front tilt bolt slightly to allow the display to tilt. 2. With display at desired tilt, tighten the rear tilt bolt. Tighten front tilt bolt if necessary. djusting Swivel Tension 1. Remove plastic bolt cap from each end of swivel bolt (below). 2. Using a 1/2'' wrench on each end of the bolt, tighten or loosen bolt to achieve desired swivel tension. 3. Replace bolt caps. olt aps (2) Swivel olt Rear Tilt olt Front Tilt olt U-FLP-0010-01 Rev 9/08/08 GX orp. Page 5 of 6

Routine Maintenance Periodically inspect all mounting hardware. Tighten or adjust as necessary for optimal operation and safety. leaning the Mounting ssembly 1. The mounting assembly may be cleaned with most mild, non-abrasive solutions commonly used in the hospital environment (e.g. diluted bleach, ammonia, or alcohol solutions). 2. The surface finish will be permanently damaged by strong chemicals and solvents such as acetone and trichloroethylene. 3. o not use steel wool or other abrasive material to clean the mounting assembly. 4. amage caused by the use of unapproved substances or processes will not be covered by warranty. We recommend that any cleaning solution be tested on a small area of the mounting assembly that is not visible to verify compatibility. 5. Never submerge or allow liquids to enter the mounting assemblies. Wipe any cleaning agents off the mounting assembly immediately using a water-dampened cloth. ry all mounting assemblies thoroughly after cleaning. UTION: GX makes no claims regarding the efficacy of the listed chemicals or processes as a means for controlling infection. onsult your hospital s infection control officer or epidemiologist. To clean or sterilize mounted instruments or accessory equipment, refer to the specific instructions delivered with those products. U-FLP-0010-01 Rev 9/08/08 GX orp. Page 6 of 6