USER GUIDE. Mini InfraRed Thermometer with Laser Pointer MODEL 42500

Similar documents
High Temperature InfraRed Thermometer with Laser Pointer

USER GUIDE. IR Thermal Scanner. Model IRT500

Non-contact Forehead IR Thermometer

User Manual InfraRed Thermometer With Laser Pointer and High/Low Alarms Model IR270

Non-contact Forehead IR Thermometer

User Guide. Heavy Duty Psychrometer + IR Thermometer. Model HD550

Heavy Duty CFM-CMM Thermo-Anemometer With built-in non-contact IR Thermometer and Laser Pointer Model HD300

OPERATION MANUAL INFRARED THERMOMETER FIRT 500

IR-829 Infrared Thermometer User Manual

Model R2002. Instruction Manual. Infrared Thermometer. reedinstruments www.

16mm. inch. Sensor Beam

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297

TERMOMETRO A DISTANZA A INFRAROSSI INFRARED NON-CONTACT THERMOMETER THERMOMÈTRE À INFRAROUGES SANS CONTACT TERMÓMETRO INFRARROJO SIN CONTACTO

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

Non-Contact Infrared Thermometers. 8818H/8819H/8828H series. Operation Manual

User Guide. AC/DC Mini Clamp Meter. Model

Non-Contact Infrared Thermometers Operating Manual

User Guide. EasyView Digital Light Meter. Model EA31

Professional Dual-Laser Infrared Thermometer with 50:1 Distance-to-Sight Ratio, Data Logging, USB Output, Single Type K Input, and Temperature Alarm

USER MANUAL. UV AB Light Meter. Model UV505. Additional User Manual Translations available at

User s Guide. Model MA A AC Mini Clamp-on Meter

INSTRUCTION MANUAL INF Fax: (503)

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

EasyView Light Meter with Memory

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

USER MANUAL. LUX/FC Light Meter. Model LT505. Additional User Manual Translations available at

netzerotools.com USER GUIDE Extech LT40 LED Light Meter Extech LT45 Color LED Light Meter LED Light Meter Model LT45 netzerotools.

USER MANUAL. Laser Distance Meter MODELS DT40M, DT60M, and DT100M

400Amp True RMS AC Clamp Meter + NCV

R/C SMD Tweezers Multimeter Model RC200

Passive Component LCR Meter

Micro-Ohmmeter Model UM200

Laser Distance Finder Extech DT500

Infrared Thermometer Remote Temperature Measurement ( Non-Contact ) 1327 INSTRUCTION MANUAL

USER GUIDE. White LED Light Meter. Model LT Washington Street Melrose, MA Phone Toll Free

400Amp True RMS AC/DC Clamp Meter Model EX613

MT2 and MT4 Noncontact Thermometer Berührungsloses Thermometer Thermomètre sans Contact Termómetro sin Contacto Termômetro sem Contato

Advanced Test Equipment Rentals ATEC (2832)

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Laser Distance Finder Extech DT500

RF EMF Strength Meter

Handheld Infrared Thermometers

USER MANUAL. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

Infrared Gun. Perfect For. Easy To Use. Features. Get Professional Results Every Time! Battery Installation. Model: IN1022

Psychrometer With IR DT-8896 Operation Manual

MICROSCANNER TM D-Series

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

USER GUIDE. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

ed560l Laser Distance Meter User Manual

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

RF EMF Strength Meter

Compact MultiMeters + Voltage Detector

User s Guide. Combination Photo-Tachometer Stroboscope Model

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

Bidirectional Ultrasonic Distance Measurement

Visit us at

Carbon Monoxide (CO) and Carbon Dioxide (CO 2 ) Meter With Air Temp/RH Measurements and Dew Point/Wet Bulb calculations

LA-1010 User s Manual 3 in 1 Stud/Metal/AC Voltage Finder With Laser Line Level.

THERMAL PROFILE OF HOT MIX ASPHALT

Manifold Electronic Gauge. Model: KC-100B-1 Operation Manual

30:1 ULTRA WIDE-RANGE IR THERMOMETER WITH K PORT USER S MANUAL

Measuring. Calibrating. Testing. Measuring and calibration for use in Ex-hazardous areas.

User s Guide. Digital AC/DC Clamp Meter Model 38394

Dawson DSM150. Digital Light Meter User s Manual

True RMS AC / DC Power Clamp Meter Model

User's Guide. AC Circuit Load Tester. Model CT70

Fluke 570 Series Infrared Thermometers:

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

QUANTUM CALCU-FLASH-S OPERATING INSTRUCTIONS

User Manual 4 wire Earth Resistance Tester Model GRT300

200Amp AC Clamp Meter + NCV Model MA250

Laser LA-4P. Operating instructions

12:1 INFRARED THERMOMETER with K TYPE THERMOCOUPLE & ADJUSTABLE EMISSIVITY

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

Model OI-6940 Notis Quad 4-Gas Sensor Assembly

User Guide. Digital AC/DC Clamp Meter Model 38394

Mini Environmental Quality Meter

Manual Laser Range Finder PCE-LDM 44

Operating Manual Infrared thermometer

LazerTape 160. Lazer Distance Meter TRIPLETT. Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

Thermal Imaging Camera IR0001. Instruction Manual

ProfiScale MULTI Multimeter

Power Measurment. Hand-held Design Brings Peak Performance to the Field. Introduction. Features

TYPE - K.J.E.T. PRINTING THERMOMETER. Model INSTRUCTION MANUAL

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

GSIR 6816 Series Infrared Thermometer

Ambient Weather WS-0270 Wireless Indoor / Outdoor Thermometer with Indoor Humidity User Manual

Digital Wireless Weather System

USER MANUAL. Multi Field EMF Meter. Model EMF Washington Street Melrose, MA Phone Toll Free

DT-250 Instruction manual AM/FM stereo 2 bands PLL Synthesized Personal Radio

Model: &

OPERATIONS MANUAL DP-110 IN-DUCT DIGITAL PSYCHROMETER TABLE OF CONTENTS

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

Revision 1.8 II WARANTY

INTRODUCTION CHAPTER 1

SILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets

Transcription:

USER GUIDE Mini InfraRed Thermometer with Laser Pointer MODEL 42500

Introduction Congratulations on your purchase of the Model 42500 IR Thermometer. This thermometer makes noncontact (infrared) temperature measurements at the touch of a button. The built-in laser pointer increases target accuracy while the backlit LCD and handy push-buttons combine for convenient, ergonomic operation. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version of this User Guide, Product Updates, and Customer Support. Safety Use extreme caution when the laser pointer beam is on Do not point the beam toward anyone's eye or allow the beam to strike the eye from a reflective surface Do not use the laser near explosive gases or in other potentially explosive areas Meter Description 1. LCD Display 2. Function Buttons 3. Handle Grip 4. IR Sensor 5. Laser pointer beam 6. Measurement Trigger 7. Battery Compartment 1 2 3 4 5 6 7 2

Operating Instructions 1. Hold the meter by its Handle Grip and point it toward the surface to be measured. Read the Field of View section below for distance to target ratio information. 2. Pull and hold the Trigger to turn the meter on and begin testing. The display will light if the battery is good. Replace the battery if the display does not light. 3. While continuing to pull the Trigger: a. Push the Laser button to switch the laser pointer ON. When the laser is on, the laser icon will appear on the LCD over the temperature reading. Aim the red beam approximately a half inch below the point of test (pressing the Laser button again turns the laser off). b. Select the temperature units using the o C / o F button. c. Push the backlight button to switch ON the LCD backlighting function. 4. Release the Trigger; the reading will hold for approximately 6 seconds, after which the meter will automatically shut off. 5. The meter defaults to the programmed conditions in use when the meter was last switched off. For example, if the laser is set to ON and the temperature units are set to o F at the time the unit is switched OFF, the unit will switch ON and use the same settings. Over-range Indicator If the temperature measurement exceeds 500 F (260 C), the thermometer will display dashes in place of a temperature reading. Field of View The meter s field of view is 6:1. For example, if the meter is 12 inches from the target (spot), the diameter of the target must be at least 2 inches. Other distances are shown below in the field of view diagram. Note that measurements should normally be made closer than 2 feet from the target. The meter can measure from further distances but the measurement may be affected by external sources of light. In addition, the spot size may be so large that it encompasses surface areas not intended to be measured. 3 0.5 6 Diameter of Spot 2 1 12 24 4 Sensor Beam 0.63 Laser Beam Distance to Object 3

Measurement Notes 1. The object under test should be larger than the spot (target) size calculated by the field of view diagram. 2. If the surface of the object under test is covered with frost, oil, grime, etc., clean before taking measurements. 3. If an object's surface is highly reflective apply masking tape or flat black paint to the surface before measuring. 4. The meter may not make accurate measurements through transparent surfaces such as glass. 5. Steam, dust, smoke, etc. can obscure measurements. 6. The meter compensates for deviations in ambient temperature. It can, however, take up to 30 minutes for the meter to adjust to extremely wide ambient temperature changes. 7. To find a hot spot, aim the meter outside the area of interest then scan across (in an up and down motion) until the hot spot is located. Battery Replacement When the low battery symbol appears on the LCD, replace the meter s 9V battery. The battery compartment is located on the bottom of the meter's handle. Open the compartment by sliding the battery compartment cover off in the direction of the arrow. Replace battery and re-install the battery compartment cover. You, as the end user, are legally bound (EU Battery ordinance) to return all used batteries, disposal in the household garbage is prohibited! You can hand over your used batteries / accumulators at collection points in your community or wherever batteries / accumulators are sold! Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the end of its lifecycle 4

Specifications Infrared Thermometer Specifications Range / Resolution -4 to 500 o F (-20 to 260 o C) 1 o F/C Accuracy ± 2% of reading or ±4 o F (2 o C) whichever is greater, from 60 to 113 o F (15 to 50 o C) ± 3% of reading or ±6 o F (3 o C) whichever is greater, for remainder of range: -4 to 500 o F( -20 to 260 o C) Note: Accuracy is specified for the following ambient temperature range: 64 to 82 F (18 to 28 C) Emissivity 0.95 fixed value Field of View D/S = Approx. 6:1 ratio (D = distance, S = spot) Laser power Less than 1mW Spectral response 6 to 14 m (wavelength) General Specifications Display Display rate Operating Temperature Operating Humidity Power Supply Automatic Power Off Weight Dimensions 1999 count, backlit LCD display with function indicators 1 second approx. 32 F to 122 F (0 C to 50 C) Max. 80% RH 9V battery Meter shuts off automatically after 6 seconds 4.9 oz. (140g) 6.7 x 1.7 x 1.6 (170 x 44 x 40mm) Copyright 2013 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form www.extech.com 5