Fiber Optic Outside Plant Cables (4-144 Fibers)

Similar documents
Single-Armored Cables, Fibers

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

features and benefits

Exhibit A Construction Project Manual and Drawings

Outdoor, Fig 8 Armored, Multi Tube

Outdoor, CCTV or CCTV, Fig 8 Armored.

Outside Plant All Dielectric

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

Datasheet Outside Plant Cable

Ø 1250 * 688 mm 93 kg ± 105m

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

Industrial Automation

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

Optical Systems Contents

Ø560*336mm 4.25 kg 2100 ± 105m

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

FTTH Fiber Optical Cable

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

Fibre Optic Indoor/Outdoor Cable

TECHNICAL DATASHEET FOR LOOSE TUBE OPTICAL FIBER CABLE. Air Blown Micro LC Cable

SPECIFICATION. Optical Fiber Cable

Z EE E E Z E Z Z Z Z Z

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

How Bend Insensitive Multimode Fiber is Affecting Installation and Testing of Enterprise and Data Center Cabling

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

Standard Monotube SAFE

Type QG-G50-2C- M-BU

CORNING OPTICAL COMMUNICATIONS GENERIC SPECIFICATION FOR FlexNAP DISTRIBUTION SYSTEMS: DISTRIBUTION TRUNK, TAP, AND TETHER. July 2018.

ekсkoм TECHNICAL DATA SHEET FOR Duct/Aerial Application kabeli.eu (SM 24 Fibers) Technical literature for Optical Fiber Cable

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Optical Fiber Cable. MODEL:GYTA53 PE Jacket. optic.com. For detailed inquiry please contact our sales team at:

One Enterprise. One Infrastructure. One Partner. Optical Fiber Loss Testing. Optical loss testing in the field is not as simple as it seems.

Installing the Avaya 10-Gigabit

LSSS-OF FOR. Zero Water Peak Single-Mode Optical Fiber. (Reference: ITU-T G.652.D) Prepared by Eun Kyung Min Engineer Passive Solution Team

Integrating Global Communications...

Faster. Easier. Better.

Optical Ground Wires (OPGW)

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813

Install & Go SMARTen (Cat.6A) STP Trunk Cable Assembly General

Migration to 50/125 µm in the Local Area Network

GYFY-24FO Total Dry. Item Material Description PE outer sheath HDPE Nominal thickness:1.8mm

SPECIFICATION FOR SINGLE-MODE OPTICAL FIBRES

u n a B Optical Cables UNIFLEX CABLES LTD.

ORTRONICS FIBER TRUNK CABLE SYSTEM BY LEGRAND. designed to be better.

Bending the Truth - Get the straight story about Corning ClearCurve multimode fibers

Parallel Fiber Application Note Introduction to types and uses of parallel multi-mode ribbon cable in optical fiber data transmission.

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

UNIRAIL D RS485 and BUS cables

Introduction.

CUSTOM DESIGN COAXIAL CABLES BY SICAB

Install & Go Cat.8 STP Trunk Cable Assembly Description

Filled Solid ALPETH Cable

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

Detailed Specifications & Technical Data

14 AWG 2 AWG: 600 Volt

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

ENDLESS INNOVATION OPTICAL FIBER. Bendfree Bendfree+ UltraPass. WidePass. Ultra Bendfree

Product Bulletin. Temperature Tunable 10 mw WDM Laser for Direct Modulation in Links up to 180 km CQF413/608 Series

FiberHome Fiber Products

400G-BD4.2 Multimode Fiber 8x50Gbps Technical Specifications

AVA5-50FX. Product Classification. Standards And Qualifications. Construction Materials. Dimensions. Electrical Specifications

Medium Voltage Power Cables

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

NETWORK CONNECTIVITY SYSTEMS

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

REQUEST FOR INFORMATION (RFI) RFI NO: /WJG

Canadian OSP Copper I-1. Table of Contents

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

SPECIFICATION. FOR SINGLE-MODE OPTICAL FIBER (FutureGuide -SR15E)

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

* Peaks of 1.3mm MAX allowed only in a rate of 2% or less

White Paper: The Ins and Outs of Testing Bend Insensitive Multimode Fiber (BIMMF): The Need for Encircled Flux

CommunicationCables FIBER OPTICS OPGW FTTH

Nexans Industrial Solutions PRODUCT CATALOG

kv: medium voltage reeling cable with fibreoptics

Multi Fiber Cable Assemblies

af-phy July 1996

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, SEMIRIGID, COAXIAL, SEMI-AIR-DIELECTRIC,.875 TO INCHES OUTSIDE DIAMETER, 50 OHMS

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

C400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

FIBER OPTIC CABLE ASSEMBLIES

Fireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485

Optical Fiber Attributes

C240-NFSM-3M. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR

Product Bulletin. 2 mw WDM Laser for Direct Modulation in Links up to 100 km CQF915/108 Series

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

UTP Copper. SFTP Copper. FUTP Copper. Composite. Special Applications Copper. Category 5e. Category 6 Category 5E Category 3. Category 7A Category 7

AMP NETCONNECT Category 6 System

Transcription:

Fiber Optic Outside Plant Cables (4-144 ) Central Tube Dielectric Cable 4-12 Fiber Water Blocking Strength Members Multi-Tube Dielectric Cable 24-216 Fiber The number of tubes changes depending on fiber count. Central Strength Member Water Blocking Strength Members Central Tube Armored Cable 4-12 Fiber Water Blocking Strength Members Corrugated Steel Armor Multi-Tube Armored Cable 24-144 Fiber The number of tubes changes depending on fiber count. Central Strength Member Water Blocking Strength Members Corrugated Steel Armor Description: AMP NETCONNECT outside plant cables are designed for campus-type environments or for long runs between buildings in aerial, duct or direct buried installations. The cables consist of 250µm inked fibers encased in color coded buffer tubes with a water-barrier gel filling compound. Central tube designs (4 to 12 fibers) include a single tube surrounded by water blocking strength members and a medium-density polyethylene outer jacket. Stranded tube designs (24 to 144 fibers) include multiple tubes stranded around a central strength member, then covered by water blocking strength members and a medium-density polyethylene outer jacket. The cables are available in all dielectric and corrugated steel tape armored versions. All cables have a black outer jacket. Standards Compliance: AMP NETCONNECT cables are designed and tested to conform to the fiber and cable performance requirements of TIA 568, ISO 11801, Telcordia GR-20-CORE and ICEA-640 Standards. Cable Print: Cables will be marked every two feet with: AMP NETCONNECT OPTICAL CABLE OSP or OSPA <fiber count> <fiber type> MM/YY SO<shop order number> XXXXX FEET Specification 114-92003 Revision E Date 12/8/2010 Page 1 of 5

Fiber Optic Outside Plant Cables (4-144 ) Dielectric Part Numbers: Fiber Count Units x /Unit 62.5/125µm 50/125µm 50/125µm OM3 50/125µm OM4 Single-mode 4 1 x 4 6-1553386-1 6-1553386-2 6-1553386-4 6-1553386-5 6-1553386-3 6 1 x 6 6-1553387-1 6-1553387-2 6-1553387-4 6-1553387-5 6-1553387-3 8 1 x 8 6-1553388-1 6-1553388-2 6-1553388-4 6-1553388-5 6-1553388-3 12 1 x 12 6-1553389-1 6-1553389-2 6-1553389-4 6-1553389-5 6-1553389-3 24 2 x 12 (with 3 fillers) 6-1553390-1 6-1553390-2 6-1553390-4 6-1553390-5 6-1553390-3 36 3 x 12 (with 2 fillers) 6-1553391-1 6-1553391-2 6-1553391-4 6-1553391-5 6-1553391-3 48 4 x 12 (with 1 filler) 6-1553392-1 6-1553392-2 6-1553392-4 6-1553392-5 6-1553392-3 72 6 x 12 6-1553393-1 6-1553393-2 6-1553393-4 6-1553393-5 6-1553393-3 96 8 x 12 6-1553394-1 6-1553394-2 6-1553394-4 6-1553394-5 6-1553394-3 144 12 x 12 6-1553395-1 6-1553395-2 6-1553395-4 6-1553395-5 6-1553395-3 216 18 x 12 6-1553440-1 6-1553440-2 6-1553440-4 6-1553440-5 6-1553440-3 Armored Part Numbers: Fiber Count Units x /Unit 62.5/125µm 50/125µm 50/125µm OM3 50/125µm OM4 Single-mode 4 1 x 4 6-1553396-1 6-1553396-2 6-1553396-4 6-1553396-5 6-1553396-3 6 1 x 6 6-1553397-1 6-1553397-2 6-1553397-4 6-1553397-5 6-1553397-3 8 1 x 8 6-1553398-1 6-1553398-2 6-1553398-4 6-1553398-5 6-1553398-3 12 1 x 12 6-1553399-1 6-1553399-2 6-1553399-4 6-1553399-5 6-1553399-3 24 2 x 12 (with 3 fillers) 6-1553400-1 6-1553400-2 6-1553400-4 6-1553400-5 6-1553400-3 36 3 x 12 (with 2 fillers) 6-1553401-1 6-1553401-2 6-1553401-4 6-1553401-5 6-1553401-3 48 4 x 12 (with 1 filler) 6-1553402-1 6-1553402-2 6-1553402-4 6-1553402-5 6-1553402-3 72 6 x 12 6-1553403-1 6-1553403-2 6-1553403-4 6-1553403-5 6-1553403-3 96 8 x 12 6-1553404-1 6-1553404-2 6-1553404-4 6-1553404-5 6-1553404-3 144 12 x 12 6-1553405-1 6-1553405-2 6-1553405-4 6-1553405-5 6-1553405-3 Specification 114-92003 Revision E Date 12/8/2010 Page 2 of 5

Fiber Optic Outside Plant Cables (4-144 ) Hybrid Outdoor Cables: Total OSP (dielectric) or OSPA (armored) Single-mode 50/125µm OM2 50/125µm OM3 50/125µm OM4 fibers 62.5/125µm Part Number 12 OSP 6-6 - - 2111077-1 18 OSPA 6 12 - - - 1499599-1 24 OSP 12 12 - - - 1553484-8 24 OSP 12-12 - - 2111078-1 24 OSP 12 - - 12-1499948-1 24 OSP 12 - - - 12 4-1664208-5 24 OSPA 12 - - 12-1499951-1 24 OSPA 12-12 - - 2111084-1 36 OSP 12 - - - 24 4-1664209-5 48 OSP 24 - - 24-4-1664420-5 48 OSPA 24 24 - - - 1553296-1 48 OSP 24 - - - 24 1553602-8 72 OSP 24 - - - 48 4-1664210-5 96 OSP 48-48 - - 1777230-1 96 OSP 72 - - - 24 1777205-1 96 OSP 72 - - 24-1777231-1 96 OSPA 48 48 - - - 1553503-8 96 OSPA 48-48 - - 1553504-8 192 OSP 96-96 - - 1777229-1 Note: Hybrid cables shall be constructed in order of core size from smallest to largest. (i.e. single-mode fibers taking the first positions, followed by 50/125µm then 62.5/125µm). Specification 114-92003 Revision E Date 12/8/2010 Page 3 of 5

Fiber Optic Outside Plant Cables (4-144 ) Performance Specifications: AMP NETCONNECT outside plant cables are designed and tested in accordance with TIA 568, ISO 11801, ICEA 640, and Telcordia GR-20-CORE. Performance specifications are measured in accordance with the Fiber Optic Test Procedures (EIA/TIA-455 documents) and the test procedures of IEC 60793 and IEC 60794. Mechanical Specifications: Cable Type Dielectric Fiber Count (tubes x fibers per tube) 4 (1 x 4) 6 (1 x 6) 8 (1 x 8) 12 (1 x 12) 24 (2 x 12 with 3 fillers) 36 (3 x 12 with 2 fillers) 48 (4 x 12 with 1 fillers) 72 (6 x 12) 96 (8 x 12) 144 (12 x 12) Cable O.D. 11.7±1.7 (0.46±0.06) 13.2±1.8 (0.52±0.07) 16.9±1.8 (0.67±0.07) Tube O.D. Nominal Weight kg/km (lbs/1000ft) Rated Tensile Load Long Install Term N (lbf) N (lbf) Minimum Bend Radius Long Install Term 100 (67) 2670 (600) 890 (200) 242 (9.5) 121 (4.8) 93 (62) 2670 (600) 890 (200) 242 (9.5) 121 (4.8) 97 (65) 2670 (600) 890 (200) 242 (9.5) 121 (4.8) 130 (87) 2670 (600) 890 (200) 252 (9.9) 126 (5.0) 158 (106) 2670 (600) 890 (200) 287 (11.3) 144 (5.6) 252 (169) 2670 (600) 890 (200) 364 (14.3) 182 (7.2) 216 (18 x 12) 17.3±2.2 (0.68±0.08) 264 (177) 2670 (600) 890 (200) 376 (14.8) 188 (7.4) Armored 4 (1 x 4) 6 (1 x 6) 8 (1 x 8) 12 (1 x 12) 24 (2 x 12 with 3 fillers) 36 (3 x 12 with 2 fillers) 48 (4 x 12 with 1 fillers) 72 (6 x 12) 96 (8 x 12) 144 (12 x 12) 14.7±2.9 (0.58±0.11) 16.3±3.1 (0.64±0.12) 20.0±3.2 (0.79±0.13) 214 (144) 2670 (600) 890 (200) 315 (12.4) 158 (6.2) 218 (146) 2670 (600) 890 (200) 315 (12.4) 158 (6.2) 223 (150) 2670 (600) 890 (200) 315 (12.4) 158 (6.2) 265 (178) 2670 (600) 890 (200) 335 (13.2) 167 (6.6) 307 (206) 2670 (600) 890 (200) 378 (14.9) 189 (7.4) 498 (335) 2670 (600) 890 (200) 455 (17.9) 228 (9) Specification 114-92003 Revision E Date 12/8/2010 Page 4 of 5

Fiber Optic Outside Plant Cables (4-144 ) Performance Characteristics: 62.5/125µm 50/125µm 50/125µm OM3 50/125µm OM4 Single-mode (1310nm/1550nm) Maximum Attenuation 3.5/1.2 db/km 3.5/1.5 db/km 3.2/1.2 db/km 3.2/1.2 db/km 0.4/0.3dB/km OFL Bandwidth 200/500 MHz km 500/500 MHz km 1500/500 MHz km 3500/500 MHz km Not Applicable 850nm Effective Modal Not Applicable Not Applicable 2000 MHz km 4700 MHz km Not Applicable Bandwidth 10 Gigabit Ethernet at 850nm 33m 82m 300m 550m Not Applicable Maximum Distance Fiber Specification TIA-492AAAA IEC 60793-2-10 A1b TIA-492AAAB IEC 60793-2-10 A1a.1 TIA-492AAAC IEC 60793-2-10 A1a.2 TIA-492AAAD IEC 60793-2-10 A1a.3 TIA-492CAAB ITU-T G.652.D Temperature Ratings: Operation Installation Storage/Shipping -40 C to +70 C -30 C to +60 C -40 C to +70 C (-40 F to +158 F) (-22 F to +140 F) (-40 F to +158 F) U.S.A. 1-800-553-0938 Canada 905-475-6222 Mexico 52-55-1106-0800 South and Central Americas 54-11-4733-2200 On the web: http://www.ampnetconnect.com/ email: mailto:networking.help@tycoelectronics.com Copyright 2010 by Tyco Electronics Corporation. All Rights Reserved. AMP, AMP NETCONNECT, NETCONNECT, LIGHTCRIMP, LIGHTCRIMP PLUS, and TYCO are trademarks. OTHER PRODUCTS, LOGOS AND COMPANY NAMES MENTIONED HEREIN MAY BE TRADEMARKS OF THEIR RESPECTIVE OWNERS. Specifications subject to change without notice. Specification 114-92003 Revision E Date 12/8/2010 Page 5 of 5