Rotary actuators for ball valves

Similar documents
Rotary actuators for ball valves

Rotary actuators for ball valves

Rotary actuators for ball valves

GLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V

Rotary actuators for ball valves

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

Rotary actuators for ball valves

Air damper actuators

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

Configured air damper actuators 6FU11xx-xDxxx-xxxx

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

OpenAir Linear actuators GDB/GLB...2 Technical basics. CE1Z4664en Building Technologies

Electromotoric actuators

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Functional data Factory settings Variable Settings

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

Technical Instructions Document No EA GQD June 23, OpenAir

Electromotoric actuators for stroke valves

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electromotoric actuators for valves

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke

Room Temperature Controllers. for heating and cooling systems

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

Outside Temperature Sensors

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

s Climatix extension module 26 I/Os POL985.00/XXX

Room Sensors. for relative humidity and temperature

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

DCS-62 Series Spring Return Electronic Actuator Product Bulletin

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

M7061 ROTARY VALVE ACTUATORS

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

QFM21... Duct sensors. Symaro. for relative humidity and temperature

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Room sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Electronic Air / Fuel Ratio Control System

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

Overview of types. Technical data

Modulating control valves with magnetic actuator, PN 16

Differential pressure sensors

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Rotary gear motor series AG8...

OpenAir Electric Damper Actuators GDE/GLB Series Non-spring Return Rotary 24 Vac - Modulating Control 0 to 10 Vdc

Spring Return DuraDrive Proportional Actuator

Explosion proof rotary actuator - On/Off or programmable regulating actuator

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Power amplifier for thermic valve actuators

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Rotary Measuring Technology

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

RE17LLBM asymmetrical flashing relay s V AC - solid state output

Zelio Control Measurement Relays

Room Temperature Sensors

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

EC centrifugal fan. backward curved, single inlet

Type 3374 Electric Actuator

Rotary Measuring Technology

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Type overview. Technical data

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

Actuators for modulating control AME 85, AME 86

MODEL: MRP6. Final Control Elements

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

Rotary Measurement Technology Incremental Encoders

QAC910. Meteo Sensor. Synco living

Technical data. Parameterisable damper actuator in the

Wireless multizone receiver RDE-MZ6

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data sheet. Technical data. Safety notes

Power consumption In operation At rest For wire sizing

Transcription:

4 658 Rotary actuators for ball valves for ball valves VAI61.. / VBI61.. and VAI60.. / VBI60.. / DC 24 48 V / AC 230 V Electromotive rotary actuators with spring return for emergency position For 2-position, 3-position, and modulating control Pre-wired with 0.9 m long connection cables Remarks This data sheet provides a brief overview of these rotary actuators. Please refer to the Technical Basics in document Z4614en for a detailed description as well as information on safety, engineering notes, mounting and commissioning. Use For 2-port and 3-port threaded control ball valves from DN15 to DN50 For open/close ball valves 2-port and changeover ball valves 3-port, internally threaded connections DN15 to DN50 Suitable for use with modulating controllers (DC 0 10 V), 3-position controllers or 2-position controllers In plants where the rotary actuator must move to the zero position (emergency position) during power failure C2N4658en 2012-11-12 Building Technologies

Type summary GA121.9E GA321.9E GA131.9E GA161.9E Operating voltage / DC 24 48 V Operating voltage AC 230 V Control type 2-position Control type 3-position Positioning signal Y = Position indicator U = Functions Type 1) GA..21.9E GA131.9E GA161.9E Control type 2-position control 3-position control odulating control Rotary direction for mounting on ball valve (NC/NO) Emergency position (Spring return) Position indication: echanical Position indication: Electrical anual adjustment NC (normally closed) ball valve Switch on operating voltage: Actuator opens (counter-clockwise) Switch off operating voltage: Actuator closes with spring (clockwise) NC (normally closed) ball valve Signal on Y1 rotation counterclockwise ball valve opens Signal on Y2 rotation clockwise ball valve closes NC (normally closed) ball valve 0 10 V counter-clockwise Flow = 0% at Y = 0 V Flow = 100% at Y = 10 V See the mounting instructions 4658 for other switchings. On power failure or when the operating voltage is switched off, the spring moves the ball valve to its mechanical zero position. Rotary angle position indication with manual lever as position indicator. Output voltage U = DC 0...10 V is generated proportional to the rotary angle. Without voltage supplied, the rotary actuator can be rotated and fixed in any position using the supplied Allen key. The rotary actuator returns to the zero position (actuator closed) if mechanically unlocked via Allen key or via short-term voltage supply. 1) When combining GA..1E and ASK77.2: You must consult the mounting instructions 4696 (74 319 0648 0)! Equipment combinations The rotary actuators are suitable for operation of the following Siemens ball valves: VAI61.. 2-port control ball valves Type k vs [m 3 /h] Rp DN PN Δp max Δp s VAI61.15.. 1 10 Rp ½ 15 VAI61.20.. 4 10 Rp ¾ 20 350 1400 VAI61.25.. 6.3 16 Rp 1 25 PN40 VAI61.32.. 10 25 Rp 1¼ 32 1000 VAI61.40.. 16 40 Rp 1½ 40 350*/240** 800 VAI61.50.. 25 63 Rp 2 50 600 Data sheet N4211 2/6

VBI61.. 3-port control ball valves Type k vs [m 3 /h] Rp DN PN Δp max Δp s VBI61.15.. 1.6 6.3 Rp ½ 15 VBI61.20.. 4 6.3 Rp ¾ 20 350 1400 VBI61.25.. 6.3 10 Rp 1 25 PN40 VBI61.32.. 10 16 Rp 1¼ 32 1000 VBI61.40.. 25 Rp 1½ 40 350*/240** 800 VBI61.50.. 40 Rp 2 50 600 Data sheet N4211 * VAI61.32-10/16, VAI61.40-16, VAI61.50-25 **VAI61.32-25, VAI61.40-25/40, VAI61.50-40/63 * VBI61.15 VBI61.40-16 **VBI61.40-25, VBI61.50-40 VAI60.. / VBI60.. open/close 2-port and changeover ball valves 3-port Type k vs [m 3 /h] Rp DN PN Δp max Δp s VAI60.15-15 15 Rp ½ 15 VAI60.20-22 22 Rp 1 20 1400 VAI60.25-22 22 Rp 1 25 PN40 350 VAI60.32-35 35 Rp 1¼ 32 1000 VAI60.40-68 68 Rp 1½ 40 800 VAI60.50-96 96 Rp 2 50 600 Data sheet N4213 VBI60.15-5L 5 Rp ½ 15 VBI60.20-9L 9 Rp 1 20 VBI60.25-9L 9 Rp 1 25 VBI60.32-13L 13 Rp 1¼ 32 VBI60.40-25L 25 Rp 1½ 40 VBI60.50-37L 37 Rp 2 50 VBI60.15-12T 12 Rp ½ 15 VBI60.20-16T 16 Rp 1 20 VBI60.25-16T 16 Rp 1 25 VBI60.32-25T 25 Rp 1¼ 32 VBI60.40-49T 49 Rp 1½ 40 VBI60.50-73T 73 Rp 2 50 PN40 350 N4213 PN40 350 N4213 Notes For more details about these rotary actuators see document Z4614. ounting Both ball valve and rotary actuator can easily be assembled at the mounting location. Neither special tools nor adjustments are required. The rotary actuator is supplied with ounting Instructions 4658 (74 319 0653 0) The ball valve: VAI61.. / VBI61.. is supplied with ounting Instructions 4211 (74 319 0647 0), the ball valve: VAI60.. / VBI60.. is supplied with ounting Instructions 4213 (74 319 0883 0). Orientation 90 90 4716Z16 Commissioning When commissioning the system, check wiring and the function of the rotary actuator. 3/6

Technical data Supply voltage DC 24 48 V (SELV / PELV) Supply voltage AC 230 V Function data Positioning signal for GA131.9E Positioning signal for GA161.9E Position indicator for GA161.9E Connection cables Degree of protection of housing Protection class Environmental conditions Standards and directives Weight Operating voltage AC / Frequency Operating voltage (DC) Power consumption GA1.1.9E: Running GA121.9E/GA131.9E: Holding GA161.9E: Holding Operating voltage AC / Frequency Power consumption GA321.9E Running Holding Nominal torque Nominal rotary angle / ax. rotary angle Runtime for rotary angle 90 (motor operation) Closing time with return spring (on power failure) Switching current (at / DC 24 48 V) for "Open"/"Close" Input voltage Y (wires 8-2) ax. permissible input voltage Output voltage U (wires 9-2) ax. output current Cross-section of the prewired connection cables Standard length Degree of protection as per EN 60 529 (note mounting instructions) Insulation class / DC 24 48 V AC 230 V Operation / Transport Temperature Humidity (non-condensing) Product standards Automatic electrical controls for household and similar use Electromagnetic compatibility (EC) Immunity Emission CE conformity EC directive Low voltage directive ± 20 % / 50/60 Hz DC 24 48 V ±20 % AC: 5 VA / 3.5 W // DC: 3.5 W AC/DC: 2 W AC/DC: 2.5 W AC 230 V ± 10 % / 50/60 Hz 7 VA / 4.5 W 3.5 W 7 Nm 90 / 95 ± 2 90 s 15 s > AC/DC 8 ma DC 35 V DC ± 1 ma 0.75 mm 2 0.9 m IP54 EN 60730 lll ll IEC 60721-3-3 / IEC 60721-3-2 32...+55 C / 32...+70 C < 95% r. h. / < 95% r. h. EN 60730-2-14 (ode of operation, Type 1) IEC 61000-6-2 IEC 61000-6-3 2004/108/EC 2006/95/EC C-Tick conformity Emissions AS / NZS 61000-6-3 Without packaging: GA1..9E GA3..9E 1.2 kg 1.3 kg Disposal The document on technical basics Z4614en and the environmental declaration provide information on environmental compatibility and disposal of this device. 4/6

Internal diagrams GA..21.9E GA131.9E GA161.9E 2-position control 3-position control odulating control 1 (G) AC 0 V 6 7 1 8 (G0) 2 AC 230 V 3 (L) (G) (G0) 1 2 100% 0% (G0) (U) 2 9 (N) 4 Cable labeling Connection Cable Code No. Color Abbreviation eaning Rotary actuators G 1 red RD System potential / DC 24 48 V G0 2 black BK System neutral DC 24 48 V Y1 6 purple VT Positioning signal AC 0 V, / DC 24 48 V "counter-clockwise" N.C. Y2 7 orange OG Positioning signal AC 0 V, / DC 24 48 V "clockwise" N.C. Y 8 grey GY Positioning signal U 9 pink PK Position indication Rotary actuators L 3 brown BN Line AC 230 V AC 230 V N 4 blue BU Neutral Dimensions 465801a Dimensions in mm = > 100 mm = > 200 mm inimum clearance from ceiling or wall for mounting, connection, operation, maintenance etc. 5/6

6/6 2010 2012 Siemens Switzerland Ltd Subject to change