Test systems made by SebaKMT. Don t stress over tests! SebaKMT has the right answers: reliability, speed, economy.

Similar documents
VLF. DAC tandelta. Partial Discharge. Experience the world of Megger electrical testing

Investigations on a Combined Resonance/VLF HV Test System Partial Discharge (PD) characteristics at VLF and DAC voltages

BEST PRACTICES FOR OFFLINE DIAGNOSIS OF MV CABLES

vlocpro NEW Features & Accessories NEW Standard Features available now! New Displays

HVA SERIES VLF TEST SETS. Hipot Testers HVA Series for VLF (0.1 Hz) testing of MV and HV cables.

Cable testing and diagnostics

PHG 70 TD PD / PHG 80 TD PD

CITY SERIES. Compact, fully equipped cable fault location, test and diagnostic systems

EI HIGH VOLTAGE INSULATION TESTING POLICY

OFFLINE PD DIAGNOSTICS USING SEVERAL EXCITATION VOLTAGES

NEW. The new Centrix 2.0 sets the standard for testing, diagnosis and fault location of power cables.

Fault location on power cables. Fault location on power cables

Cable test vans and systems

Cable test vans and systems

portable affordable CDS Series Cable Fault Locators Thumpers - Surge Generators

ECP HV INSULATION TESTING

INSULATION DIAGNOSIS OF HIGH VOLTAGE POWER CABLES

ECP HV INSULATION TESTING

Specialists in HV and MV test and diagnostics. Testing in Substations

Centrix 2.0 The world s most modern and powerful cable test van system

Simultaneous Partial Discharge and Tan Delta Measurements: New Technology in Cable Diagnostics

Field Experiences. Partial Discharge Diagnosis on MV Cables. Philipp Legler. XVI. Szigetelésdiagnosztikai Konferencia (

BY JASON SOUCHAK, Megger

H V T E S T S O L U T I O N S PA RT N E RS F O R H V & E M C

PRY-CAM BREAKTHROUGH TECHNOLOGY FOR CONDITION ASSESSMENT AND ASSET MANAGEMENT

USING DAMPED AC VOLTAGES

High Voltage Diagnostics Sarl 4, Rue de Lac CH 1897 Le Bouveret Switzerland

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Cable diagnostic in MV underground cable networks

MV Power Cable Diagnostics by Frequency Domain Spectroscopy. Peter Werelius Programma Electric AB

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

Testing and PD Diagnosis of MV Cable Systems with DAC Voltage Educational Session May St Pete Beach, Fl

CIGRE General Session, Paris 2014 Group Meeting SC B1 Insulated Cables, 27th August, 2014 Results of CAG Questionnaire

Transformer condition assessment with an integrated test van

NOVEL METHOD FOR ON-SITE TESTING AND DIAGNOSIS OF TRANSMISSION CABELS UP TO 250KV

Cable fault location. The shortcut to locating a fault

Insulating oil testing

PD Testing Considerations for MV Plant Cables

Aspects of PD interpretation in HV power cables. by Edward Gulski, Piotr Cichecki, Rogier Jongen

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Onsite Mobile AC High Voltage Test System

Assuring the Reliability of Critical Power Cable Systems

Cable fault location in power cables. Systematics for cable testing, diagnosis and cable fault location

HVI - The World s Source For High Voltage Test Equipment

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

Insulating oil testing

MONTRANO. Continuous monitoring system for power transformers

MIT510/2, MIT520/2 and MIT1020/2

Long lengths transmission power cables on-site testing up to 500 kv by damped AC voltages

Why partial discharge testing makes good sense

Equipment for cable fault location, testing and diagnostics

TRAINING OVERVIEW EDUCATION IS POWER. HIGH V O L T A G E T E S T S OLUTION S. reliable. precision.

EQUIPMENT AND MOBILE LABORATORIES FOR NDT AND DIAGNOSTICS OF UNDERGROUND COMMUNICATION LINES.

MEDIUM & HIGH VOLTAGE

Exploring the Necessity of the Hot Hipot Test

IN HOUSE CALIBRATION OF PD DETECTOR SYSTEM FOR FIELD TEST RESULT RELIABILITY

ONLINE OFFLINE B Y WIL L IAM H IG INBOT H AM,

ELECTRICAL SAFETY TESTERS. Wings for Your Projects. APPLICATION NOTE

Base Station Installation and Maintenance

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

OMICRON Seminar on Partial Discharge Diagnostics on HV Assets. January 30, 2018 Beirut, Lebanon

Top-Innovator MotorAnalyzer 2. Multi-purpose testers for electric motors and windings. Made in Germany Expect more.

Sensor Technology. Applications for medium voltage

HV Module Systems for Testing, Training and Research

MIT510, MIT520 and MIT1020

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

HV AC TESTING OF SUPER-LONG CABLES

Reprint E Two Years of Experience with a Mobile Resonant Test System for Testing of Installed Medium- and High Voltage Power Cables

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

Partial Discharge, Survey or Monitor?

MV Power Cable Testing Training

General Specifications

Dynamic MotorAnalyzer

CIGRE- AORC Technical Meeting 2016 and International Conference on Global Trends in the Development of Power T&D System including Smart Grid

IMPORTANCE OF ACCURATE MEASUREMENTS DURING THE LIFE CYCLE OF UTILITIES

An Overview of Diagnostic Testing of Medium Voltage Power Cables John Densley

PD Solutions. On-Line PD Measurement Devices

Large-Capacity, High-Efficiency 3-Level UPS for North America 7000HX-T3U

Continuous Monitoring on the SSE Networks Transmission System

EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY

The Polytransformer. The Multivoltage Substation Power Transformer

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

Estimating the Impact of VLF Frequency on Effectiveness of VLF Withstand Diagnostics

5-kV and 10-kV Insulation Resistance Testers. n CAT IV 600 V safety rating. n Line supply or battery operated

Innovative Test Techniques and Diagnostic Measurements to Improve the Performance and Reliability of Power System Transformers

Xu Xiao Ming, AP Services, March 2010 Machine services Life expectance analysis program (LEAP)

Partial discharge diagnostics on very long and branched cable circuits

Ground Bond & Optional HV & HC Scanner. Ground Bond & Functional Run Test. Ground Bond, Functional Run Test & Line Leakage Test. Features and Benefits

RESIDUAL LIFE ASSESSMENT OF GENERATOR TRANSFORMERS IN OLD HYDRO POWER PLANTS

PERMANENT ON-LINE MONITORING OF MV POWER CABLES BASED ON PARTIAL DISCHARGE DETECTION AND LOCALISATION AN UPDATE

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

METREL Measuring and Regulation Equipment

OMICRON Seminar on Substation Testing and Diagnosis. October 23, 2017 Dubai, United Arab Emirates. October 24, 2017 Abu Dhabi, United Arab Emirates

AORC Technical meeting 2014

Dynamic MotorAnalyzer

PD Diagnostic Applications and TechImp solutions

IDAX 300 Insulation Diagnostic Analyzer. Dielectric Frequency Response Also known as: Frequency Domain Spectroscopy

SENSITIVITY ASPECTS OF ON-LINE PD DIAGNOSIS OF MV POWER CABLES

PDL 650. Acoustic PD Fault Localization in High-Voltage Equipment

Transcription:

Test systems made by SebaKMT Don t stress over tests! SebaKMT has the right answers: reliability, speed, economy.

Know how to do it. And what happens next. Test first and save later Connected to the future To make networks more economical and to increase is still essential! Cable faults aren t just infuriating. For the network operator, they usually take up enormous resources in terms of logistics, time and therefore money. That is why it s vital that electrical installations and equipment are checked to see that they fulfi l all the necessary standards, both before they are fi rst used and after any modifi cations or repairs. Test systems made by SebaKMT As the world s leading developer of measuring instruments, SebaKMT can offer the whole palette of useful and effi cient testing technologies. For medium voltage networks SebaKMT offers sine wave test systems as well as its patented cosine rectangular wave test systems. Solutions are available ranging from portable units to powerful systems with 25 µf testing capacity. The test used originally for the medium voltage range is becoming more and more widespread for high and extra-high voltages. This has essentially been the result of the increase in HV connections in on- and off-shore applications. the reliability, commissioning tests are being increasingly performed in combination with partial discharge with a partial discharge diagnosis. You can fi nd more detailed information about this subject in the SebaKMT diagnosis brochure. Along with the withstand test, the quality of the cable laying and installation is being increasingly combined with a PD diagnosis (pictures ABB) 2 3

sine wave testing: compatibility and convenience as standard. For all requirements, for all applications... The SebaKMT sine wave test systems range from portable, robust and versatile systems such as the sine wave 34 kv to integrated test systems, for example diagnostic test vans. All the systems are designed for continuous operation which prevents unnecessary waiting times and increases test effi ciency drastically. Compatible and expandable SebaKMT test systems with a sinusoidal voltage can be upgraded with SebaKMT diagnostic technologies to create universal test and diagnostic systems. A tan delta test attachment can turn the portable devices into the ideal solution for mobile loss factor measurements. You can fi nd more detailed information about the tan delta test attachment in the SebaKMT diagnosis brochure. Convenient and multifunctional Whether it s a portable device or a unit integrated in a test van, a SebaKMT system can always be operated easily and reliably. The convenient single-button operation is based on the wellestablished Centrix software, the fruit of decades of development experience from SebaKMT. All SebaKMT sine wave test systems have USB logging as standard. This makes working in the fi eld far easier. Furthermore all systems are provided with an integrated sheath fault testing and fault pinpointing facility, using step voltage procedures and automatic frequency adjustment. SebaKMT diagnosis brochure sine wave 34 kv Test, diagnosis and fault location van Centrix 1-40 + sine wave 54 + TanD + OWTS M 28 4 5

The CR test: achieve more with less! As simple as voltage, as reliable as voltage Test passed The 0.1 Hz test, based on the cosine rectangular wave voltage, was developed and patented by SebaKMT more than 25 years ago. There are now in excess of 2,500 systems with this technology being used. Practical fi eld experience and numerous scientifi c studies have confi rmed the effectiveness of SebaKMT 0.1 Hz cosine rectangular wave systems for PE/XLPE, paper-impregnated cables and their accessories. This is refl ected today in all the common standards. Clear benefits The main advantages of the cosine rectangular wave technology used by SebaKMT are the near-operational test parameters and extremely low power consumption, combined with the high testable capacity. Low power consumption is possible because the electricity stored in the cable is reused. Any losses are compensated for and the cable is recharged with the opposite polarity. It is precisely this polarity reversal that allows the test to be performed with a near-operational frequency. Because even if the test uses 0.1 Hz, the polarity reversal itself is a full sine or cosine wave that ranges from 50 to 100 Hz. The extremely effi cient use of energy compared to conventional technologies allows effective testing with very low power consumption. Three-phase testing can even be easily performed on long cables, subsequently the test time is reduced by a third. Suited for special requirements Cosine rectangular wave technology is particularly useful due to the wide range of testable voltages. This also enables highly powerful, customised solutions to be created. A 60 kv/25 µf installation has already been set up, for example. cosine rectangular wave voltage and polarity reversal Our test equipment is also ideally suited for offshore applications, e.g. testing of 35 kv rated cables using the CR-60 6 7

The CR test: because simple is simply better. Clear test results and clear benefits in terms of mobility Test and diagnosis van with CR-80 + OWTS M 60 and SPG 40 Time will tell! Both the VDE standard and international standards recommend a test duration of one hour for XLPE cables. This makes sense since defects, particulary water trees, in the XLPE insulation very often lead to a breakdown just shortly before the 60 minutes test duration passes. All SebaKMT test systems are ideally suited for this test duration and are even designed for continuous operation. Hightech for easy handling cosine rectangular wave test systems from SebaKMT have a host of features that make work far simpler for your staff and reliably document the test results. Leakage current measurement The leakage current measurement is used for evaluating the quality of the cable by recording the trend during the test. Parameterisation The measurements taken are stored on a chip card, ready for further processing, and printed as a report using the software supplied. At the same time, the measurement parameters can be transferred to the chip card, allowing the system to be programmed directly with the test parameters stored. This avoids operator error and provides very high consistency in test quality and repeatability. After the test, all the results are stored on the chip card. A print-out of the report, automatic breakdown detection and storage of the measurements also make up the package alongside the test results. Easytest now even easier! The Easytest represents a simplifi ed version of the standard test. It has been designed to verify operational integrity versus operational reliability, which is the objective of a standard test in accordance with the respective standards. Typically, a simplifi ed test is performed in accordance with company specifi cations after repairs or after a new cable or circuit has been installed. The purpose of this test is a workmanship test to verify the integrity of splices and terminations before switching a circuit back into service. Unfortunately, it is still common practice to perform this type of testing with a traditional hipot tester. The test voltage of 20 kv is well above the normal operating voltage in order to provide a safe indication regarding operational integrity. CR-40 Easytest 20 kv 8 9

and testing: trusted technology at its most modern. with voltage with voltage The OWTS HV 250 allows testing up to 250 kv using the method. Flexibility is the trump card voltage testing was the fi rst, and for a long time, the only method to check cables. This is refl ected in its widespread use. It offers outstanding performance even today, especially with cables with PVC and paper insulation. SebaKMT voltage testing They are used ideally for: devices cover all applications paper-insulated cables and ranging from low voltage to high accessories and extra-high voltage. HV cables HV transformers switchgear/bushings SebaKMT has solutions, starting with small, portable and batteryoperated appliances through to the modular and bipolar 800 kv system for testing HV transmission cables. Portable 800 kv SebaKMT voltage test system Effective and flexible Today, the 50 Hz test is still the most effective method because its voltage shape and frequency come closest to the operating parameters of the test objects. Due to their small and portable design, SebaKMT 50 Hz test devices were developed specially for analysing transformers, switchgear and other components with low capacity. T 22/1 These products range from 35 kv to 350 kv. Using the same basic components as for the voltage test, optional rectifi ers can also be employed for a voltage test. The method For a number of years now, SebaKMT has also been offering the method in addition to the 50 Hz test. The advantage of this standardised process with damped voltage is that, despite being small, the corresponding systems are extremely powerful. The integrated PD detection and localisation facilities also enable normcompliant PD measurements to be performed. Because of the valuable information it provides, the PD measurement is being increasingly used for commissioning testing. The test and diagnostic systems range from 28 kv to 350 kv. You can fi nd more information about this technology and SebaKMT OWTS systems in the SebaKMT diagnosis brochure. SebaKMT diagnosis brochure 1 0 1 1

Countries with SebaKMT representatives Expertise: We are the world s leading developer and manufacturer of measurement equipment for diagnosing the condition of networks and for locating faults. Our market sectors include electricity supply networks as well as communication and pipe networks. Performance: We concentrate on five areas: network condition analysis, cable fault location, leak location, sewer TV inspection and line location. We are thus in the position to offer high performance in each of these areas. Availability: SebaKMT has representatives in 130 countries worldwide with excellently trained staff and the most modern technology. This means we have the best service and support network coverage in the industry. Wherever your international activities may lead you we look forward to speaking to you. SebaKMT Dr.-Herbert-Iann-Straße 6 96148 Baunach/Germany Tel. +49 (0) 95 44-6 80 Fax +49 (0) 95 44-22 73 sales@sebakmt.com www.sebakmt.com Broschüre_Prüfung_eng_2011_43 sebakmt is the registered trademark of the sebakmt Group