NRT 300: Electronic air-conditioning controller, heating/cooling, equiflex

Similar documents
43.019/1. NRT 300: Electronic controller for air-conditioning (heating/cooling) Sauter Components

NRT 105: Electronic fan-coil controller, equiflex

NRT 107: Room- and supply-temperature controller, equiflex

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

EY-EM 527: Remote I/O module, ecolink527

Room Temperature Controllers. for heating and cooling systems

43.030/1. NRT 101: Electronic room-temperature controller with time program. Sauter Components

Sauter Components

EY-EM 522, 523: Remote I/O module, ecolink522, 523

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Technical data. Safety notes. T5-HT24-SR-T en v Subject to changes 1 / 3

EQJW145. Content: 1 General. 2. Indicators and operating controls 3. Putting into service (by a technician) 4. How to operate (user)

Control solutions Biofloor

Self-learning Room Temperature Controller Receiver

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

Radiocontrol F. Floor Heating Controller Radio control system for floor heating

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Overview of types. Technical data

TLC3-BCR-U Series Thermostat

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Functional data Factory settings Variable Settings

EYL225: nova225, Compact automation station

CR24-.. Single room controllers

Fan-coil intelligent unitary controller

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

Electromotoric actuators

Power consumption In operation At rest For wire sizing

SERVICE-MANUAL ROOM TEMPERATURE CONTROLLER NEA 230V / 24V. Construction Automotive Industry

Room Temperature Sensors

SRC-110 Series Zone Controllers with Modbus RTU

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

ASV115CF132: Standard VAV compact controller

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Extension for ground plate Z-SMA. Shaft extension AV8-25. Reversible spindle clamp K-SA. Damper crank arm KH8. Extension from SM.. or AM.. to SM..A..

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Room Temperature Controller with Built-in Room Sensor 1 Feb 2002

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

Fan Coil Actuator FCA 2

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

R7426A. MicroniK 200 TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK

CONTROL Room. Room product for Swegon s WISE system for demand-controlled ventilation. Quick facts Room control against temperature, CO 2

/2 way motorised valves

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

Spring Return DuraDrive Proportional Actuator

Intelligent Compact Controller

Power consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

General Specifications

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke

Technical data. Safety notes

Non-Spring Return DuraDrive Modulating Actuator

Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

Technical manual GS 4x.00 knx application description air quality sensor

Room Sensors. for relative humidity and temperature

minimal installation depth: 57 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

Outside Temperature Sensors

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Electronic Air / Fuel Ratio Control System

Room sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Power amplifier for thermic valve actuators

Universal Controller

About AB Industrietechnik

PRODUCT MANUAL. ABB i-bus KNX VC/S 4.x.1 Valve Drive Controller

Microprocessor-based Temperature Controller

minimal installation depth: 25 mm without plug-in terminal min-/max-value recording display flashing at threshold exceedance / undershooting

Rotary actuators for ball valves

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

B 520 ELECTRONIC AMBIENT TEMPERATURE CONTROLLERS. RTB C2 Eng. COSTER BUS. B RTB C2 Eng MC REV 01

INSTAT 868 Radio Frequency Single-Room Controls

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

ASV115CF152: VAV compact controllers for laboratory and pharmaceutical applications

DDC volume flow controller

Process displays For standard signals, temperature, resistance measurement

Transcription:

roduct data sheet 43.019 NR 300: Electronic air-conditioning controller, heating/cooling, equiflex ow energy efficiency is improved ey directly on device for individual changeover between presence and absence Areas of use Individual unitary control and zone control (heating, cooling, heating/cooling) e.g. in air conditioning units (- or 4-pipe systems) in hotels and residential and business spaces. Features Air-conditioning controller for - and 4-pipe systems (heating, cooling, heating/cooling) easurement of room temperature by either integrated or external temperature sensor Saves energy costs by means of frontal presence/absence key and rotary knob Inputs for C/O signal, changeover between presence and absence, dew-point monitoring and setpoint shift Choice of or I control with -point, pulse-pause, 3-point or outputs (0...10 V) LED indicator SERVice level with adjustable control parameters Frost-protection function Electrical connection in baseplate Electronics in attachable housing NR300F0*1 NR300F041 echnical data NR300F061 ower supply ower supply 4 V~, ±0%, 50...60 z ower consumption Approx..5 VA arameters Dead zone Sensor time constant for air Setting range 10...30 C roportional band...0 Integral action time...0 min or OFF (as -controller) eriod or running time of actuator 0.5...0 min Control parameters Non-volatile Normal 0,4...5 Extended 8 In room (0.1 m/s) 8 min In duct (0.5 m/s) 3 min In duct (3 m/s) 1 min Admissible ambient temperature 0...50 C Admissible ambient humidity 5...95% rh, no condensation Command variable w 0...10 V, Ri = 90 kω Influence of w 1.6 /V Operating mode Sequence (heating/cooling) Change-over functions1), C/O, Weight 0.1 kg ousing ure white (RAL 9010) ousing material Fire-retardant thermoplastic Fitting Wall fitting/recessed junction box Ambient conditions Inputs/Outputs Function Construction 1) Cable feed At rear Screw terminals For wire of up to 1 mm² = dead zone ON/OFF; c/o = summer/winter, (changeover); = dew-point monitoring Right of amendment reserved 015 Fr. Sauter AG 7.3 1/7

Standards and directives ype of protection I 30 (EN 6059) rotection class III (IEC 60730) CE conformity according to EC directive 004/108/EC EN 61000-6-1, EN 61000-6-, EN 61000-6-3, EN 61000-6-4 Overview of types ype Output signal Load on outputs NR300F041 Switched 0.5 A (0.9 A when external sensor fitted) NR300F061 Continuous 0...10 V, load > 5 kω; with overflow > 11 V (load-dependent) A NR300F061: Suitable as a master controller for max. 10 NR300: (slope S = -band X p ; shift starting point FF = setpoint X s ; operating mode = sequence) Accessories ype AVF*** AV*** AX*** AX** EG10F001 EG10F101 Description otorised valve actuator (see product data sheet) otorised valve actuator (see product data sheet) otorised valve actuator (see product data sheet) hermal valve actuators (see product data sheet) Dew-point monitor with sensor in housing Dew-point monitor with sensor on cable 09674000 Sensor holder for wall mounting 0368139000 Rubber bung as sensor holder in ventilation duct 030314000 Recessed junction box 031314001 Fing kit for all applications (holder, heat-conducting paste, retaining strap) 0313347001 Cover plate, pure white, for 76 76 mm 0313367001 Cable-type sensor (NC) 1.5 m, for measurements in air duct, max. 70 C, R5 = 10 kω 0313367003 Cable-type sensor (NC) 3.0 m, for measurements in air duct, max. 70 C, R5 = 10 kω 0313367010 Cable-type sensor (NC) 10 m, for measurements in air duct, max. 70 C, R5 = 10 kω 031336700 Cable-type sensor (NC) 0 m, for measurements in air duct, max. 70 C, R5 = 10 kω 0313409001 older for sensor cartridge in ventilation duct 0313414001 Bracket for wall mounting 038673001 lug-in power unit, input 30 V~, output 1 V~ (0.34 A), length of cable 1.8 m, I 30 0313501001 ousing with scale 10...30 C Description of operation he temperature is measured with a temperature sensor. In the room controller, the sensor is integrated into the housing. For channel controllers, an external sensor is connected. he resistance of the sensor is converted into an actual-value signal (x i ) by a measuring bridge, and is then compared with the setpoint X S. he controller amplifies the control offset and, depending on its type, creates the corresponding output signals: F041, S1/ = OFF: OEN/SO/CLOSED signals (3-point control) for the I control with a motorised drive without a positioner. For heating with changeover to cooling via external signal (C/O) for -pipe system. F041, S1/ = ON: ulse-pause signals (-point control) for control for heating and cooling, for a thermal or continuous actuator for 4-pipe systems, or heating with changeover via external signal (C/O) to cooling for thermal actuator of a -pipe system. F061: Continuous signal for I control for heating and cooling, for a continuous actuator for 4-pipe systems, or heating with changeover via external signal (C/O) to cooling for continuous actuator of a -pipe system. /7 7.3 Right of amendment reserved 015 Fr. Sauter AG

100 Stroke % 0 h n I-part -part ime Open-Stop-Close signals (roportional-integral control F041) In the case of an abrupt control offset, first a longer pulse and then continuous smaller I pulses are output, until the control offset is smaller than half the switching range X Sh. 1 0,5 0 E ulse-ause signals (proportional control F041) Control factor E (pulse duration/period duration) changes in proportion to the control offset. As a result, the average heating output also changes, as well as the stroke of a proportional thermal actuator such as a -controller. / XSd E=0,5 x E=0,50 XSh E=0,75 B01806_de Dead zone changeover (X t ): hus, for the heating/cooling sequence, the dead zone is increased to 4. As a result, the temperature is decreased in heating mode and increased in cooling mode (Eco mode). Setpoint shift (command variable w): he setpoint is increased with respect to the defined value X S with an influence of + 1.6 /V. his can be used, for example, to adjust the room temperature to the increasing outside temperature (summer shift), or to avoid condensation due to rising humidity. Dew point (): Frost-protection function: When the contact of the dew-point monitor is closed, the cooling output becomes inactive or the cooling valve is closed. Independently of the defined setpoint and dead zone, at temperatures < 6 C, the heating valve is opened. If the temperature rises above 7 C, the frost-protection function becomes inactive. If necessary, the temperature must be compensated in order to adhere precisely to the switching points. Summer-/wintertime changeover (C/O): When the contact is closed, the output for heating is switched to cooling. Factory settings: roportional band Dead zone for normal Integral action time emperature compensation X p = X tn = 0.4 t n = inactive ZERO = inactive Additionally for F041: eriod or running time t p = 4 min t y = 4 min Control characteristics n X tr = X tn ± 4 F041 F061 F041 F061 100% 10V 100% 10V y1 y y1 y 50% 5V 50% 5V 0% 0V XS 0% 0V XS Contact X t open; presence: sequence operating mode (heating and cooling). When actual value x i = setpoint X s : both control units closed Contact X t closed; absence: sequence operating mode (reduced mode). he dead zone is increased and causes a decrease in the heating mode and an increase in the cooling mode. Right of amendment reserved 015 Fr. Sauter AG 7.3 3/7

Fixed-value + schedule function With NR 300 as the master controller With NR 300 as the slave controller aster controller Output Room temperature C 10V y S Command variable C Command variable C FF Output y or y 1 of the master controller can influence multiple controllers. With setpoint adjustment knob X S, shift starting point FF can be selected, and with - band X the slope can be selected. Intended use In the fixed-value range, all the connected controllers regulate to the defined value X S. In the follow-on range, the temperature is increased with slope S. he result of the influence of 1.6 /V for the slave controller and the -band of the master controller of 10 V/X is: S = 16/X p. With X =...0 for the master controller, the following slope results in /: S = 8...0.8 his product is only suitable for the purpose intended by the manufacturer, as described in the Description of operation section. All related product documents must also be adhered to. Changing or converting the product is not admissible. Disposal When disposing of the product, observe the currently applicable local laws. ore information on materials can be found in the Declaration on materials and the environment for this product. Connection diagrams NR 300 F041: 4-pipe system/-pipe system/-pipe system NR300 F041 (pt) S1/ = On I (3pt) S1/ = Off 4V~ S1/1 S ;n; ;p I S1/ A sequence B change-over B/A S ;n; ;y I S1/ 1 int shift setpoint change-over R = 100% dead zone shift setpoint change-over R = 100% dead zone 9 8 7 6 10 3 4 5 4 5 7 6 10 3 4 5 313367 w c/o w c/o ext NR 300 F061: 4-pipe system/-pipe system 4/7 7.3 Right of amendment reserved 015 Fr. Sauter AG

Dimension drawing Accessories 9674 15 9, 5 0 50 6 4 50 0038c 368139 Ø1...14 Ø11 Ø16,5 8,5 5, Right of amendment reserved 015 Fr. Sauter AG 7.3 5/7

31314 313409 Ø 5,8 mm 38 313367 6 Ø 9 mm 10 30 400,5 7 55 07779 50 Ø6 08443 38673 40 51 57 313414 8 1,5 30 15 4,5 08557 07778 74 3,5 40 60 95 6/7 7.3 Right of amendment reserved 015 Fr. Sauter AG

Fixed-value control for heating/cooling NR 300 NR 300 NR 300 4V~ 1 4 5 y1 y 6 10 3 6 10 3 6 10 3 c/o F041: amum of 4 actuators per output F061: Outputs y 1 and y (total load > 5 kω) for actuators with positioner, e.g. max. 6 per R i = 30 kω (AVR...S, B1W...S, V1W...S, AR...S, A...S) Fixed-value + schedule control with NR 300 F061 as master controller 4 V~ NR 300 F061 NR 300 NR 300 1 S1/1 = ON 0-10V 0-10V 0-10V Y1 Y 1 W Y1 Y 1 0-10V W Y1 Y 9 8 4 5 w1 w 7 3 4 5 7 3 4 5 ext w1 w y1 y y1 y 1 3 1 3 1 3 1 3 GND Outputs w1 (y 1 ) and w (y ) (total load > 5 kω) of the master controller to shift max. 10 NR 300 ey w eating Cooling emperature Command signal Fr. Sauter AG Im Surinam 55 C-4016 Basel el. +41 61-695 55 55 www.sauter-controls.com Right of amendment reserved 015 Fr. Sauter AG 7.3 7/7