Agilent 81133A/81134A

Similar documents
AP034-OM-E Rev D ISSUED: January 2000 ²

Agilent Technologies 8133A 3 GHz Pulse Generator. Technical Specifications. The Standard in Pulse Generator Technology.

PXIe Contents. Required Software CALIBRATION PROCEDURE

Supplement. TDS5032 and TDS5034 Digital Phosphor Oscilloscopes

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

CERTIFICATE OF CALIBRATION

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications

DS 6000 Specifications

LAB I. INTRODUCTION TO LAB EQUIPMENT

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators

Agilent InfiniiVision 4000 X-Series Oscilloscopes. Service Guide

HP 16533A 1-GSa/s and HP 16534A 2-GSa/s Digitizing Oscilloscope

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.

Basic Communication Laboratory Manual. Shimshon Levy&Harael Mualem

TECHNICAL MANUAL INSTRUMENT CALIBRATION PROCEDURE PEAK POWER ANALYZER HEWLETT-PACKARD 8991AOPT003

54645D. Mixed Signal Oscilloscope

Notes on Experiment #1

Model 305 Synchronous Countdown System


ECE65 Introduction to the Function Generator and the Oscilloscope Created by: Eldridge Alcantara (Spring 2007)

Arbitrary/Function Generator AFG1000 Series Datasheet

Function Generator Guide Tektronix AFG3102

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

9200 Series, 300 MHz Programmable Pulse Generator

PXIe Contents CALIBRATION PROCEDURE

Specifications for DS1000CA Series

5790A/AF AC Measurement Standard

Test ID 5-15 Utility Line Impedance Test Procedures Guide

Oscilloscope Operation. Visualizing Signals and Making Measurements

ASNT_PRBS43A 48Gbps PRBS7/PRBS15 Generator with USB Control Interface

LAB I. INTRODUCTION TO LAB EQUIPMENT

Model 310H Fast 800V Pulse Generator

SAMPULSE50GHz and SAMPULSE70GHzANT PULSER/SAMPLER DEMO BOARD

PC-OSCILLOSCOPE PCS500. Analog and digital circuit sections. Description of the operation

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

MULT SWP X1K K VERN START FREQ DURATION AMPLITUDE 0 TTL OUT RAMP

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

Agilent E2695A SMA Probe Head for InfiniiMax 1130 Series Active Oscilloscope Probes. User s Guide

Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1]

Fluke 5820A Oscilloscope Calibrator Specifications

PicoSource PG900 Series

Combinational logic: Breadboard adders

3.003 Lab 3 Part A. Measurement of Speed of Light

AWG-GS bit 2.5GS/s Arbitrary Waveform Generator

Why Modern Servicing Requires Complete Waveform & Circuit Analyzing!

LeCroy 9304A, 9304AM Digital Oscilloscopes 200 MHz Bandwidth, 100 MS/s. Main Features

Analog Arts SF990 SF880 SF830 Product Specifications

Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1]

E2621A and E2622A Probe Adapters for Infiniium Oscilloscopes. User s Guide. Publication number E September 2002

EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS

U1604A Handheld Oscilloscopes, 40 MHz

Agilent U2701A and U2702A USB Modular Oscilloscope. Data Sheet

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

Virtual Lab 1: Introduction to Instrumentation

Data Sheet. Setting Standards

Calibration Guide. 8590L Spectrum Analyzer

Analog Arts SF900 SF650 SF610 Product Specifications

EENG-201 Experiment # 4: Function Generator, Oscilloscope

Digital Phosphor Oscilloscopes

NI Contents CALIBRATION PROCEDURE

Sept 13 Pre-lab due Sept 12; Lab memo due Sept 19 at the START of lab time, 1:10pm

Models 1421 and 1422 User s Manual. Broadband Amplifiers

EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial

Contents. CALIBRATION PROCEDURE NI PXIe-6555/6556. ni.com/manuals

SHF Communication Technologies AG

S5101 Handheld Radio Communication Analyzer

Appendix A: Specifications

Getting Started. MSO/DPO Series Oscilloscopes. Basic Concepts

Lab #1 Lab Introduction

TBS2000 Series Oscilloscopes Specification and Performance Verification

Experiment 1: Instrument Familiarization (8/28/06)

Name EET 1131 Lab #2 Oscilloscope and Multisim

High Speed Characterization Report

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

U1600 Series Handheld Digital Oscilloscopes

Tektronix Inc. DisplayPort Standard. Revision Tektronix MOI for Cable Tests (DSA8200 based sampling instrument with IConnect software)

GDS MHz Handheld Digital Oscilloscope New Product Announcement

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Easy to Use Design.

Contents. CALIBRATION PROCEDURE NI 5421/ MS/s Arbitrary Waveform Generator

Arbitrary/Function Waveform Generators 4075B Series

Cost-Effective Traceability for Oscilloscope Calibration. Author: Peter B. Crisp Head of Metrology Fluke Precision Instruments, Norwich, UK

FREEDOM Communications System Analyzer R8000C DATA SHEET

Circuit Characterization with the Agilent 8714 VNA

N2790A Differential Voltage Probe

EE 210: CIRCUITS AND DEVICES

Fluke 192/196/199. MS 190 and MA 190. Users Manual Supplement

Introduction to basic laboratory instruments

How to Setup a Real-time Oscilloscope to Measure Jitter

INSTRUMENTS, INC. Models 2960AR and 2965AR Disciplined Rubidium Frequency Standards. Section Page Contents

8800SX TETRA Base Station Operation

RIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.

941/942 Field Calibration C Procedure Created by: D.NEFF Date: 3JUN94 Sheet 1 of 5

FREEDOM Communications System Analyzer R8000C DATA SHEET

LeCroy 9384 Series Digital Oscilloscope 1 GHz Bandwidth, 1-4 GS/s

PIECAL 820 FIELD CALIBRATION PROCEDURE

FREEDOM Communications System Analyzer R8600 DATA SHEET

Divide. MHz models) waveform record

Laboratory Equipment Instruction Manual 2011

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Transcription:

Agilent 81133A/81134A Performance Verification Rev. 2.3, Dec. 2009 Agilent Technologies

Introduction Use these tests if you want to check that the Agilent 81133A / 81134A Pulse / Pattern Generator is working correctly. Before starting any testing allow all test equipment to warm up for at least 30 minutes and make sure that the SELFCAL of the unit was executed. Test Results Tables Tables for entering the results of the tests are included at the end of the tests. The tests are numbered and reference numbers for each Test Result (TR) are given in a small table at the end of each test. The reference number shows you where the actual results should be entered in the Test Results Tables. 3

Recommended Test Equipment and Accessories The following tables list the recommended test equipment you need to perform all the tests. You can use alternative instruments if they meet the critical specifications given. The test setups and procedures assume you are using the recommended equipment. Test Equipment Model Critical Specifications DCA Counter Digital Voltmeter Agilent 86100C with 86117A plug-in Agilent 53132A #010, 030 Agilent 3458A Agilent 34401A Frequency measurements up to 3.35 GHz, High-Stability Time Base Delay Line Agilent 54008A 22 ns (for 54120 series) 4

Accessories QTY Model Critical Specifications Attenuators 2 8493C#020 20dB Power Splitter 1 11667B SMS/SMA (m-m) Adapter SMA(f)/BNC(m) Adapter SMA Cable 1 1 Min 3 1250-1159 1250-1700 8120-4948 50 Ω Feedthrough Termination 1 10100C or better (see Figure) 2 W, 1% 10 W, 0.1 % Adapter 1 1251-2277 BNC to Banana Torque Wrench 1 8710-1582 5/16 in, 5 lb-in (56 Ncm) Important: When you connect the test equipment for the first time, and whenever you change the setup during the course of these tests, always switch off the 81133A/81134A' s outputs. Use the 8710-1582 torque wrench to tighten and loosen SMA connectors. This will ensure that the connectors are at the correct tightness and give the best signal transfer. 5

50Ohm, 0.1%, 10 W Feedthrough Termination The following figure provides a schematic and a parts list except for the case. The case must provide shielding and maintain grounding integrity. 50 Ohm, 0.1%, 10W Feedthrough Termination The following parts are required: R1 = 53.6 Ω, 1%, 10 W R2 = 200 Ω, 10%, 0.5 W, Variable Trimmer R3 = 681 Ω, 1%, 0.5 W Connectors: BNC male, BNC female 6

Test 1: Frequency Test Specifications Range: 15 MHz to 3.35 GHz Resolution: 1 Hz Accuracy: 50 ppm Equipment Needed Counter Cable 50Ω, SMA SMA/BNC adapter Procedure 1 Connect the 81133A/81134A Trigger Output to the Counter Channel 1 Input using the SMA/BNC adapter 2 Press [Recall] [0] to reset the 81133A/81134A to default settings 3 Set the 81133A/81134A as follows: 7

4 Switch on the trigger output and set the counter to measure the frequency at Channel 1 5 Check the frequency at the following settings: Frequency Acceptable Measured Frequency TR 15 MHz 14.99925 MHz to 15.00075 MHz 1-1 50 MHz 49.9975 MHz to 50.0025 MHz 1-2 100 MHz 99.995 MHz to 100.005 MHz 1-3 200 MHz 199.990 MHz to 200.010 MHz 1-4 6 Connect the 81133A/81134A Trigger Output to the Counter Channel 3 Input. 7 Press [Freq & Ratio] and select frequency 3 8 Check the frequency at the following settings: Frequency Acceptable Measured Frequency TR 500 MHz 499.975 MHz to 500.025 MHz 1-5 1.0 GHz 999.950 MHz to 1.00005 GHz 1-6 2.0 GHZ 1.9999 GHz to 2.0001 GHz 1-7 3.0 GHz 2.99985 GHz to 3.00015 GHz 1-8 3.35 GHz 3.34983 GHz to 3.35016 GHz 1-9 8

Test 2a: High and Low Levels Test Specifications Amplitude: Level Window: 50 mv pp to 2 V pp -2.00 V to +3.00 V Level Resolution: 10 mv Level Accuracy: 2 % of setting ± 20 mv Equipment needed Digitizing Voltmeter 50 Ω Feedthrough Termination, 0.1 %, 10 W BNC to Dual Banana plug Cable 50 Ω, SMA SMA/BNC adapter Procedure 1 Connect the 50 Ω Feedthrough Termination to the DVM input, using the BNC to Dual Banana plug 2 Connect the 81133A/81134A channel output to the 50 Ω Feedthrough Termination, using the SMA/BNC adapter 9

3 Set the channel to the following: 4 Set up the 81133A/81134A with a "zero" pattern as follows: On the 81134A set both channels and switch on only the channel that is being tested. 10

5 Switch on the channels and check the low level at the following settings (Program the High Level at least 500 mv larger than the Low Level to be tested) Low Level Acceptable Range TR - 2.00 V - 2.06 V to -1.94 V 2-1 -1.00 V - 1.04 V to -0.96 V 2-2 0 V - 20 mv to + 20 mv 2-3 1.00 V 0.96 V to 1.04 V 2-4 2.00 V 1.94 V to 2.06 V 2-5 6 Set up a "HI" pattern as follows: 11

7 Switch on the channel and check the high level at the following settings (Program the Low Level at least 500 mv lower than the High Level to be tested) High Level Acceptable Range TR -1.00 V - 1.04 V to -0.96 V 2-6 0 V - 20 mv to +20 mv 2-7 1.00 V 0.96 V to 1.04 V 2-8 2.00 V 1.94 V to 2.06 V 2-9 3.00 V 2.92 V to 3.08 V 2-10 For the 81134A repeat the test for the second channel. 12

Test 2b: Amplitude Test Specifications Amplitude: Resolution: Accuracy: 50 mv pp to 2 V pp 10 mv 2 % of setting ± 20 mv Equipment needed Digitizing Voltmeter 50 Ω Feedthrough Termination, 0.1 %, 10 W BNC to Dual Banana plug Cable 50 Ω, SMA SMA/BNC Adapter Procedure Same Connections as Test 2a 1 Connect the 50 Ω Feedthrough Termination to the DVM input, using the BNC to Dual Banana plug 2 Connect the 81133A/81134A channel output to the 50 Ω Feedthrough Termination, using the SMA/BNC adapter. 3 Set the channel to the following: 13

4 Set up the 81133A/81134A with a "zero pattern" as follows. On the 81134A set up both channels and switch on only the channel that is being tested. 5 Write down the measured voltage for the "zero Volt" level. 6 On the "Channel" screen switch to "Inverted" Levels and measure the high level. 7 Calculate the Amplitude from the measured levels and repeat the test for the following high levels, always measuring additionally the low level as well High Level Acceptable Range TR 50 mv 29 mv to 71 mv 2-11 1.00 V 0.96 V to 1.04 V 2-12 2.00 V 1.94 V to 2.06 V 2-13 For the 81134A repeat the test for the second channel. 14

Test 3: Overshoot and Ringing Test Specifications Equipment Needed Overshoot, Ringing < 10 % ± 10 mv Digitizing Oscilloscope 2x 20dB Attenuator 2x Cable SMA, 50 Ω Procedure 1 Connect the 81133A/81134A Trigger Output to the 86100C Trigger Input, using a 20 db attenuator 2 Connect the 81133A/81134A Channel Output to the 86117A Channel 1 input, using 20 db attenuator 3 Set up the 81133A/81134A as follows and switch on the channels. 15

On the 81134A set up both channels and switch on only the channel that is being tested. 4 On the Oscilloscope: Press [AUTOSCALE] Select Menu [Setup] -> [Averaging]: check [enable] & set Number of Averages to 64 Set the TIME/DIV to 350 ps/div (manually [Time/Delay] at the bottom) Set scale, offset and attenuation factor of channel 1 (lower left corner): Attenuation factor to 20dB Scale to 300 mv/div Offset to 950 mv Center a positive edge Press in the Ampitude Navigation Pane [Overshoot] 5 Check that the Overshoot of the positive edge is within specification (+ 10 % of amplitude ± 10 mv) and record the result in TR 3-1 Important The maximum specified overshoot is actually ± 10 % ± 10 mv which is ± 210 mv for an amplitude of 2 V. If the Overshoot is not within the ± 10% of amplitude limits, make a precise measurement against the specification of ± 210 mv. For the 81134A repeat the test for channel 2. 16

Test 4: Width Test Specifications Range: 100 ps to (period - 100 ps) Resolution: 1 ps Accuracy: ± 40 ps after autocal within a temperature range of ± 10 C Equipment Needed Digitizing Oscilloscope with Accessories 2x 20dB Attenuator 2x Cable 50 Ω, SMA Procedure Same Setup as before 1 Connect the 81133A/81134A Trigger Output to the Oscilloscope Trigger Input, using a 20 db attenuator 2 Connect the 81133A/81134A Channel 1 Output to the Oscilloscope Channel 1 Input, using a 20 db attenuator 3 Set up the Trigger Output as follows: 17

4 Set up the [Channel] screen as follows: On the 81134A set up both channels and switch on only the channel that is being tested. 5 Set the 86100C: Press [AUTOSCALE] Select Menu [Setup] -> [Averaging]: check [enable] & set Number of Averages to 64 6 Change the Agilent 81133A/81134A Width to 100 ps 7 Reduce the oscilloscope timebase to 100 ps/div and center the pulse in the oscilloscope display 8 Press in the Time Navigation Pane [More] -> [+Pulse Width] 9 Record the result in TR entry 4-1 10 Clear Display for each new setting 18

11 Check the Agilent 81133A/81134A pulse width at the following settings: Oscilloscope Timebase Width Acceptable Range TR 100 ps/div 100 ps 60 ps to 140 ps 4-1 100 ps/div 500 ps 460 ps to 540 ps 4-2 500 ps/div 1 ns 960 ps to 1.040 ns 4-3 500 ps/div 2 ns 1.96 ns to 2.04 ns 4-4 Larger pulse widths are generated with counted delays. The performance is guaranteed by the design and does not need to be verified. For the 81134A repeat the test for the second channel. 19

Test 5: Transition Times Test Specifications Transition Time (10% - 90%): Transition Time (20% - 80 %): < 90 ps < 60 ps Equipment Needed Digitizing Oscilloscope with Accessories 2x 20dB Attenuator 2x Cable SMA, 50 Ω Procedure Same Setup as before 1 Connect the 81133A/81134A Trigger Output to the Oscilloscope Trigger Input, using a 20 db attenuator 2 Connect the 81133A/81134A Channel Output to the Oscilloscope Channel input, using 20 db attenuator 3 Set up the 81133A/81134A as follows and switch on the channel 20

On the 81134A set up both channels and switch on only the channel that is being tested. 4 Rise Time 10% - 90% On the Oscilloscope: Press [AUTOSCALE] Select Menu [Setup] -> [Averaging]: check [enable] & set Number of Averages to 64 Set the Levels to 10-90% ([Measure]->[Configure Measure]- [Treshhold]) Adjust the delay until a positive edge is centered in the midle of the screen Set time to 20 ps/div Press [Rise Time] (First Button in Time Navigation Pane) 5 Check that the Rise Time 10% - 90% is < 90ps and record the measured valued in TR entry 5-1. 6 Keep in mind the actual delay (see lower section of the screen). 21

7 Fall Time 10% - 90 % On the Oscilloscope Add +33.3ns (period time divided by 2) to the delay (e.g. center of positive edge is at a delay of 37.17ns -> falling edge near 70.5ns = 37.17ns + 33.3ns) Center falling edge in the middle of the screen Press [Fall Time] in Time Navigation Pane 8 Check that the Fall Time 10% - 90% is < 90 ps and record the measured value in TR entry 5-2 9 Fall Time 20% - 80 % On the Oscilloscope Set the Levels to 20-80% ([Measure]->[Configure Measure]- [Treshhold]) Check that the Fall Time 20% - 80% is < 60 ps and record the measured value in TR entry 5-3 10 Rise Time 20% - 80 % On the Oscilloscope Go back to the remembered (original) delay (if you do not remember the delay, substract 33.3ns from your actual delay) Center the positive edge Press [Rise Time] 11 Check that the Rise Time 20% - 80% is < 60 ps and record the measured value in TR entry 5-4 For the 81134A repeat the test for channel 2. 22

Test 6: Delay Test Specifications Range: Variable Delay - 5 ns to + 230 ns Resolution: 1 ps Accuracy: ± 20 ps after autocal within a temperature range of ± 10 Equipment Needed Digitizing Oscilloscope 2x 20 db Attenuators Power Splitter SMA-SMA Adapter 3x Cable 50 Ω, SMA Procedure 1 Connect the 81133A/81134A to the oscilloscope as shown: Watch out for the colored dots in the picture above! 23

2 Set up the Pulse Generator as follows and switch on the trigger and the output channel On the 81134A set up both channels and switch on only the channel that is being tested. 24

3 Set the Oscilloscope: Press [AUTOSCALE] Set the Time/div to 5 ns/div Select Menu [Setup] -> [Averaging]: check [enable] & set Number of Averages to 64 Select [Measure]->[Configure Meas..]-[Delta Time Definition] and set both: [Edge Number 1], [Rising],[Middle Level] Adjust the delay until you see two rising edges Press [More] and [ Time] at the Navigation Pane 4 Record the measured value on the Test Record as the Fixed Delay Δt 0 for the Channel under test 5 Set the 81133A/81134A Delay to 1 ns, then press [CLEAR DISPLAY] on the Scope 6 Check the Delay at the following settings Oscilloscope Timebase Delay Acceptable Range TR 200 ps/div 1 ns 980 ps to 1.02 ns 6-1 500 ps/div 1.5 ns 1.48 ns to 1.52 ns 6-2 500 ps/div 2 ns 1.98 ns to 2.02 ns 6-3 Larger delays are generated as counted delay. The performance is guaranteed by the design and does not need to be verified. For the 81134A repeat the test for the second channel. 25

Test 7: Jitter Test Specifications Random Jitter: Data Jitter: < 4 ps RMS < 5 ps RMS Equipment Needed Digitizing Oscilloscope Delay Line Power Splitter SMA SMA Adapter 20dB Attenuator 3x Cable 50 Ω, SMA Proceure 1 Connect the 81133A/81134A to the oscilloscope as shown Watch out for the colored dots in the picture above! 26

2 Set up the [Channel] screen as follows: On the 81134A set up both channels and switch on only the channel that is being tested. 3 Set up the Oscilloscope: Press [AUTOSCALE] Select the chanel menu and set the Attenuation factor of channel 1 to 2 (because of the splitter) Center the second positive edge of the signal Increase the displayed edge by setting the timebase to TIME/DIV = 5ps/div and the vertical scale to 2mV/div In Measure/histogram/window set the measurement windows to +1mV and -1mV and horizontal to the full screen width In Measure/histogram/configure enable the histogram In measure/ tests/acquisition test set the number of samples to 100k Press [Clear Display] and [Run] Wait until all Samples are recorded (Number in DDJ Histogramm) 4 Record the RMS (=std dev) jitter. 5 Check the jitter at the following frequencies: 27

Frequency Acceptable Range TR 100 MHZ < 4 ps 7-1 1 GHz < 4 ps 7-2 2 GHz < 4 ps 7-3 6 Set the Channel Frequency Divider of the 81133A/81134A to 2 and check the clock jitter at 3 GHz. Record the result in TR 7-4. 28

7 Data Jitter Set up the 81133A/81134A as shown 8 Set up the Oscilloscope: Go to Eye/Mask Mode Disable Averaging ([Setup]->[Averaging]: uncheck [enabled] Disable [Pattern Lock] Press [AUTOSCALE] Zoom in (10ps/div 1.5mV/div) 9 Press [Jitter RMS] 10 Check the data jitter at the following frequencies: Frequency Acceptable Range TR 100 MHZ < 4 ps 7-5 1 GHz < 4 ps 7-6 2 GHz < 4 ps 7-7 11 Set the Channel Frequency Divider of the 81133A/81134A to 2 and check the data jitter at 3 GHz. Record the result in TR 7-8. For the 81134A repeat the tests for channel 2. 29

Performance Verification Test Report Agilent 81133A/81134A Date: RMA#: Serial #: Temperature: Technician #: Humidity: Frequency: TR Test / 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 1-9 15 MHz 50 MHz 100 MHz 200 MHz 500 MHz 1.0 GHz 2.0 GHz 3.0 GHz 3.35 GHz 14.99925 MHz 49.9975 MHz 99.995 MHz 190.990 MHz 499.975 MHz 999.950 MHz 1.9999 GHz 2.99985 GHz 3.34983 GHz 15.00075 MHz 50.0025 MHz 100.005 MHz 200.010 MHz 500.025 MHz 1.00005 GHz 2.0001 GHz 3.00015 GHz 3.35016 GHz Low Level (Output 1) TR Test / 2-1 2-2 2-3 2-4 2-5 -2.00 V -1.00 V 0 V +1.00 V +2.00 V -2.06 V -1.04 V -20 mv 0.96 V 1.94 V -1.94 V -0.96 V 20 mv 1.04 V 2.06 V High Level (Output 1) TR Test / 2-6 2-7 2-8 2-9 2-10 -1.00 V 0 V +1.00 V +2.00 V +3.00 V -1.04 V -20 mv 0.96 V 1.94 V 2.92 V -0.96 V 20 mv 1.04 V 2.06 V 3.08 V 81133A/81134A Performance Test Report Page 1 of 5

Low Level (Output 2) only for 81134A TR Test / 2-1 2-2 2-3 2-4 2-5 -2.00 V -1.00 V 0 V +1.00 V +2.00 V -2.06 V -1.04 V -20 mv 0.96 V 1.94 V -1.94 V -0.96 V 20 mv 1.04 V 2.06 V High Level (Output 2) only for 81134A TR Test / 2-6 2-7 2-8 2-9 2-10 -1.00 V 0 V +1.00 V +2.00 V +3.00 V -1.04 V -20 mv 0.96 V 1.94 V 2.92 V -0.96 V 20 mv 1.04 V 2.06 V 3.08 V Amplitude (Output 1) TR Test / 2-11 2-12 2-13 50 mv 1.00 V 2.00 V 29 mv 0.96 V 1.94 V 71 mv 1.04 V 2.06 V Amplitude (Output 2) only for 81134A TR Test / 2-11 2-12 2-13 50 mv 1.00 V 2.00 V 29 mv 0.96 V 1.94 V 71 mv 1.04 V 2.06 V Overshoot and Ringing (Output 1) TR Test / 3-1 pos. edge + 10 % of ampl. + 10 mv 81133A/81134A Performance Test Report Page 2 of 5

Overshoot and Ringing (Output 2) only for 81134A TR Test / 3-1 pos. edge + 10 % of ampl. + 10 mv Width (Output 1) TR Test / 4-1 4-2 4-3 4-4 100 ps 500 ps 1.0 ns 2.0 ns 60 ps 460 ps 960 ps 1.96 ns 140 ps 540 ps 1.04 ns 2.04 ns Width (Output 2) only for 81134A TR Test / 4-1 4-2 4-3 4-4 100 ps 500 ps 1.0 ns 2.0 ns 60 ps 460 ps 960 ps 1.96 ns 140 ps 540 ps 1.04 ns 2.04 ns Transition Times (Output 1) TR Test / 5-1 5-2 5-3 5-4 Rise 10 / 90 Rise 20 / 80 Fall 20 / 80 Fall 10 / 90 90 ps 60 ps 60 ps 90 ps Transition Times (Output 2) only for 81134A TR Test / 5-1 5-2 5-3 5-4 Rise 10 / 90 Rise 20 / 80 Fall 20 / 80 Fall 10 / 90 90 ps 60 ps 60 ps 90 ps 81133A/81134A Performance Test Report Page 3 of 5

Delay (Output 1) TR Test / Δt o 6-1 6-2 6-3 0.00 ns 1.00 ns 1.50 ns 2.00 ns 980 ps 1.48 ns 1.98 ns Fixed Delay 1.02 ns 1.52 ns 2.02 ns Delay (Output 2) only for 81134A TR Test / Δt o 6-1 6-2 6-3 0.00 ns 1.00 ns 1.50 ns 2.00 ns 980 ps 1.48 ns 1.98 ns Fixed Delay 1.02 ns 1.52 ns 2.02 ns Clock Jitter (Output 1) TR Test / 7-1 7-2 7-3 7-4 100 MHz 1.0 GHz 2.0 GHz 3.0 GHz 4 ps RMS 4 ps RMS 4 ps RMS 4 ps RMS Data Jitter (Output 1) TR Test / 7-5 7-6 7-7 7-8 100 MHz 1.0 GHz 2.0 GHz 3.0 GHz 5 ps RMS 5 ps RMS 5 ps RMS 5 ps RMS 81133A/81134A Performance Test Report Page 4 of 5

Clock Jitter (Output2) only for 81134A TR Test / 7-1 7-2 7-3 7-4 100 MHz 1.0 GHz 2.0 GHz 3.0 GHz 4 ps RMS 4 ps RMS 4 ps RMS 4 ps RMS Data Jitter (Output 2) only for 81134A TR Test / 7-5 7-6 7-7 7-8 100 MHz 1.0 GHz 2.0 GHz 3.0 GHz 5 ps RMS 5 ps RMS 5 ps RMS 5 ps RMS 81133A/81134A Performance Test Report Page 5 of 5