Digital Quality Control Phantom for X-ray Mammography Image

Similar documents
Quality Control of Full Field Digital Mammography Units

Improved Tomosynthesis Reconstruction using Super-resolution and Iterative Techniques

Mammography: Physics of Imaging

Practical Aspects of Medical Physics Surveys of Mammography Equipment and Facilities

Studies on reduction of exposure dose using digital scattered X-ray removal processing

Studies on reduction of exposure dose using digital scattered X-ray removal processing

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Quality Control for Stereotactic Breast Biopsy. Robert J. Pizzutiello, Jr., F.A.C.M.P. Upstate Medical Physics, Inc

Evaluation of a quality control phantom for digital chest radiography

QC Testing for Computed Tomography (CT) Scanner

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

Image Quality. HTC Grid High Transmission Cellular Grid provides higher contrast images

Computed Radiography

GE Healthcare. Senographe Crystal The choice is crystal clear

Enhanced Functionality of High-Speed Image Processing Engine SUREengine PRO. Sharpness (spatial resolution) Graininess (noise intensity)

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

General Hospital Catalog

High-Resolution Radiographs of the Hand

Breast Ultrasound QA Phantom Recommended by Japan Association of Breast and Thyroid Sonology

GE Healthcare. Senographe Crystal The choice is crystal clear

Threshold contrast visibility of micro calcifications in digital mammography

FUJICHROME PROVIA 1600 Professional [RSP]

Mammography Solution. AMULET Innovality. The new leader in the AMULET series. Tomosynthesis, 3D mammography and biopsy are all available.

STUDENT REVIEW QUESTION SET K CR/DR CONTENT AREA

IBEX TECHNOLOGY APPLIED TO DIGITAL RADIOGRAPHY

Optimization of Digital Mammography Resolution Using Magnification Technique in Computed Radiography 1

Nuclear Associates

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

Comparison between film-screen and computed radiography systems in Brazilian mammography

Image evaluation method for digital mammography with soft-copy reading using a digital phantom

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING

radiography detector

Breast Tomosynthesis. Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School

FFDM in the Field: Physicist's Role in the QC of Mammography Laser Printers May Carl R. Keener, Ph.D., DABMP, DABR

GE Healthcare. Senographe 2000D Full-field digital mammography system

Nuclear Associates

Display of mammograms on a CRT

STEREOTACTIC BREAST BIOPSY EQUIPMENT SURVEYS

Acceptance Testing of a Digital Breast Tomosynthesis Unit

Ludlum Medical Physics

GE Healthcare. Performa. High-performance breast imaging

Image Quality. HTC Grid High Transmission Cellular Grid provides higher contrast images

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II

X-RAY MEDICAL EQUIPMENT

Exposure System Selection

Your worldwide source of grids. What a difference a grid makes

Light) Conditions. Lens Aperture Shutter Speed (sec.) NOTES. Light. Conditions. Lens Aperture Shutter Speed (sec.) None LBB-12** (or Wratten No.

ZANCO Journal of Pure and Applied Sciences. Image Quality Assessment of Diagnostic X-ray machines of Different Hospitals in Erbil

Observer Performance of Reduced X-Ray Images on Liquid Crystal Displays

Amorphous Selenium Direct Radiography for Industrial Imaging

A Practical Overview of the Clinical and Operational Impact of Computed Radiography(CR) Implementations. Shirley Weddle, RT(R)(M), CIIP, BBA

Indicator of Small Calcification Detection in Ultrasonography using Decorrelation of Forward Scattered Waves

Introduction. Digital Mammography QA: Comparing the Manufacturers Recommendations. What is QC and why is it important? Review & compare QC tests

- KiloVoltage. Technique 101: Getting Back to Basics

Film Replacement in Radiographic Weld Inspection The New ISO Standard

The Evaluation of Collimator Alignment of Diagnostic X-ray Tube Using Computed Radiography System

Nuclear Associates

Investigation of the line-pair pattern method for evaluating mammographic focal spot performance

Seminar 8. Radiology S8 1

Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions. More information using less radiation

Applied Sciences at Winterthur)

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

CR Basics and FAQ. Overview. Historical Perspective

SUSPENSION CRITERIA FOR IMAGE MONITORS AND VIEWING BOXES.

Unit thickness. Unit area. σ = NΔX = ΔI / I 0

Features and Weaknesses of Phantoms for CR/DR System Testing

Automated dose control in multi-slice CT. Nicholas Keat Formerly ImPACT, St George's Hospital, London

Patient-Assisted Compression Impact on Image Quality and Workflow

MICROSTRIPS CRYSTALLINE SILICON DETECTOR FOR DIGITAL MAMMOGRAPHY ABSTRACT

Published text: Institute of Cancer Research Repository Please direct all s to:

Attikon, Rimini 1, , Athens, Greece , Athens, Greece , Athens, Greece

Radiology. Radiograph: Is the image of an object made with use of X- ray instead of light.

IBEX MATERIALS DETECTION TECHNOLOGY

FUJICOLOR NPC 160 PROFESSIONAL [NPC]

Effect of Backscattered Radiation on X-Ray Image Contrast

THE ART OF THE IMAGE: IDENTIFICATION AND REMEDIATION OF IMAGE ARTIFACTS IN MAMMOGRAPHY

LECTURE 1 The Radiographic Image

AF3-024E COLOR REVERSAL FILMS 1. FEATURES AND USES 2. SPEED

8/2/2017. Radiologist Responsibilities. Radiologist Responsibilities. Medical Physicist Mammography Equipment Evaluation and Annual Survey

Physical characteristics of four roentgenographic chains proposed for chest radiography

BASICS OF FLUOROSCOPY

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

Aspire HD. Program Manual. 2nd Edition - October 2012

DRAFT Technical evaluation of Philips Microdose SI digital mammography system

I. Introduction.

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

KODAK DIRECTVIEW CR Mammography Feature User s Guide

ACPSEM Position Paper RECOMMENDATIONS FOR A DIGITAL MAMMOGRAPHY QUALITY ASSURANCE PROGRAM V4.0

Introduction. MIA1 5/14/03 4:37 PM Page 1

DIGITAL RADIOGRAPHY ARTIFACTS

The Influence of Film Processing Temperature and Time on Mammographic film Characteristics

2017 West Coast Educators Conference Orlando. Projection Geometry. 1. Review hierarchy of image qualities (amplified version):

Comparison of computed radiography and filmõscreen combination using a contrast-detail phantom

7/24/2014. Image Quality for the Radiation Oncology Physicist: Review of the Fundamentals and Implementation. Disclosures. Outline

RADIOGRAPHIC EXPOSURE

TESTING FLAT-PANEL IMAGING SYSTEMS: What the Medical Physicist Needs to Know. JAMES A. TOMLINSON, M.S., D.A.B.R. Diagnostic Radiological Physicist

The Flash IIP Console is the heart of every FCR system. It s designed to maximize productivity in the busiest environments.

KODAK PRIMETIME 640T Teleproduction Film / 5620,7620

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

Introduction. Sam R. Kottamasu Lawrence R. Kuhns

Transcription:

Digital Quality Control Phantom for X-ray Mammography Image Yuichi Nagai, Atsuko Takada National: Cancer Hospital East Department of Radiology Collaborated by Nobuyuki Niwa : Kyoto Kagaku Co., Ltd. Introduction Yasuhito Aizawa Kyokko Co., Ltd. Recently, in Japan the incidence of breast cancer has been increasing, but the chances of survival can be improved by early detection. Therefore, more and more mammography screening is being administrated nationwide. So far, the mammography has carried out by analog medium, screen and X-ray films, and diagnoses have been made on the images. Current development in digitalization of medical imaging is significant, and the advantageous digital techniques such as image processing, data transfer and automatic diagnostic system are being used in diagnostic imaging. Those digital techniques have begun to being applied even to mammography, the field which requires the most delicate imaging. Thus there has been pressing need to create new evaluation tools for digital quality control in mammography in order to support reliable diagnosis. It is to meet the above requirements that we have developed an innovative Digital Mammography Phantom that provides comprehensive visual evaluation with one exposure, and also produce an overall source for quality control by quantifying the evaluation result. The difficulty in developing a digital imaging phantom is to quantify the graininess and granularity in images. It depends on recording latitude, output resolution and frequency enhancement. We approached the problem from several different angles, e.g. an Aluminum Ring for the evaluation of frequency enhancement, a Teflon Ruler to see contrast and resolution, and a Bar Wave Chart to check sharpness, and then integrattion of those evaluation results through an original point-system. We also carried out a performance assessment study of the phantom and the point system, comparing the phantom image and clinical image. Physical evaluation Visual evaluation 1238 Visual evaluation 45 Noise check disk 6 Contrast evaluation (characteristic curve) 7 20Lp/mm Chart X-ray image 9 Frequency enhancement check

Ⅰ -2 Contrast Disk Including Simulated Calcifications (300μ Aluminum oxide) It is important for the mammary image to catch all the fine calcifications found in actual mammary glands. Check the four disks including five calcifications each. When 5 calculi appear in every 4 disks... = 1 point Otherwise... = 0 points Standard Score : 1 Point 1mm 2mm 3mm 4mm Thick Teflon discs (Diameter:10mm) -3 Aluminum Ring: Frequency enhancement check Evaluation of the frequency enhancement processing (Frequency band and degree of enhancement) is important for checking the mammary image of patients who have breast implants. When a black border appears around the ring... = 0 points Without a black border... = 1 point When the density differs between inside and outside of the circle by more than 0.05 D... =0 Points Without density difference... = 1 point Standard Score : 2 Points Border Difference in Density

Evaluation Method Basical conditions: scanning & output Phantom body is made of tissue-equivalent material which is the same as ACR156.We used a molybdenum target and a molybdenum filter, and fixed the scanning condition as voltage 28kV and exposure 50mAs.The images were output through printers and image analyzers that each collaborating laboratories had, adjusting the density at the center of image at 1.4 more or less 0.05. I Visual Evaluation I-1 Simulated fibroid tissue, Simulated calcification and Simulated lump Each simulated tissues are arranged in a figure of "8", which is designed to change visibility gradually from left to right. When it looks like "8"= 5 points "3"= 3 points "1"= 1 point None of them = 0 points Standard Score : 9 Points 1 Simulated fibroid tissue Nylon Length: 7mm each Diameter: 3 variations (0.1mm, 0.2mm,0.3mm) 0.1mm 0.3mm 0.2mm 2 Simulated calcifications (Aluminum oxide) 3 Simulated lump b. 0.8mm thick Dots diameters: 5mm each Thickness: 3 variations (0.1mm, 0.8mm, 1mm) Material: Acrylic(a, b) : Soft polyethylene(c) c. 0.1mm thick a. 1mm thick b. 0.8mm thick

-2 Contrast evaluation (characteristic curve) Since the contrast curve of a digital image is controllable, management of contrast gradation is important. When something seems to be wrong with equipment, scanner, image analyzer or output printer, this device allows one to find out where in the contrast gradation the problem is happening. Teflon Ruler Thi k Measurement Method No point system here. Measure on the image of Teflon Ruler at every 5mm from low density area to high density area with a diffuse densitometer. Then check the resultant contrast curve.

Physical Evaluation -1 Image Granularity Check Disk Measure the image noise in two disks in order to evaluate the scanning radiation insufficiency, often caused by damaged scanner, and the effects of frequency enhancement. Radiation insufficiency: This phantom designed to suit 28kV and 50mA, though radiation dosage at 50mA depends on scanning equipment. Frequency enhancement: Frequency enhancement processing will enhance the noise at certain degree. Measurement Method 1,Scan the film with a microdensitometer Aperture width: 0.1mm Aperture height: 1mm Scanning speed: 0.1mm/sec 2,Analysis the noise by special software Scan the film with a microdensitometer Analyze the noise Standard image granularity at the range of 1-5 cycle/mm is from 10-3 to 10-4. Score is counted at each disk as follows. Low density disk High density disk When the granularity is no less than 10-2 = 0 points When the granularity is within the standard range = 1 point When the granularity is no more than 10-5 =3 Points Standard range Standard Score : 2 Points

Total Evaluation Evaluation of phantom image Standard points Visual 1 Fibroid tissue 3 2 Calicification 3 3 Lump 3 8 Teflon discs 1 9 Aluminum Ring, Border 1 9 Aluminum Ring, Contrast 1 Physical 4 High density granular disk 1 5 Low density granular dislk 1 Total standard score 14 Performance assessment study of the Digital Mammography Phantom and the point system We studied the relation between the phantom image and clinical image, based on the actual clinical samples at 9 facilities. Evaluation method of clinical images We made X-ray films of 3 kinds of clinical samples, dense, dispersed and fatty mammary glands and evaluated their graininess, sharpness and contrast. Excellent = 5 points Good = 3 points Poor = 0 points Standard average score =3 points Graininess Sharpness Contrast avarage score Fatty Dispersed Dense Fatty Dispersed Dense average

-3 Contrast Transfer Function Check the sharpness of images affected by degradation of X-ray tube,focus, etc. Sharpness is evaluated by CTF, Contrast Transfer Function, because it is better adapted to evaluate image films processed and outputted by diverse equipment than MTF. Measurement Method 1,Scan the film with a microdensitometer and record the rectangular wave amplitude with pen recorder. Aperture width: 0.01mm Aperture height: 1mm Scanning speed: 0.1mm/sec 2,Measure the ratio of wave amplitude at each frequency bands. Compare them with the standard contrast ratio, which can be seen in the top two windows of the chart, as "D=1". standard contrast: D=1 No point system here.

Relation between Phantom image and clinical image Facility Clinical image score Phantom image score A 2.94 11.816 B 3.36 15.45 C 2.43 9.17 D 2.92 12.368 E 2.92 10.183 F 2.71 10.549 G 2.58 9.45 H 2.92 12.546 I 2.67 8.628 Standard score 3 14 r=0.90735 0.666383 P<0.05 significant correlation* r=0.90735 0.797681 P<0.01 significant correlation** There is a significant relation between phantom image and clinical image. Equipment which are applied in the assessment study Scanner 1. MAMMOMAT 3000T 2. LORAD M-IV 3. Senograph 500T 4. Performa 5. Sepio 6. senograph 2000D Image analyzer 1. Fuji Computed Radiography AC-3HQ (Sampling Size : 100μ) 2. Fuji Computed Radiography 5000MA (Sampling Size : 50μ) 3. Konica Regius 150 (Sampling Size : 87.5μ) 4. GE senograph 2000D (Sampling Size : 100μ) Output printer 1. Fuji Computed Radiography CR-DP 3543T 2. Fuji Computed Radiography Dry Pix 7000 3. Fuji Computed Radiography CR-DPL 4. Konica Computed Radiography Dry Pro 752 Conclusions Today, with remarkable improvement of medical equipment, various kinds of equipment for scanning and processing mammography images are being developed. This innovative Digital Mammography Phantom makes it possible to standardize the image quality of digital mammography and to keep up the quality which is required for making clinical diagnosis.