English. Where quality becomes beauty

Similar documents
Quality Design Because you pay more and more attention to the look and effectiveness of your practice

Digital medical imaging has significantly contributed to the improvement of diagnoses and the widespread use of less

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.

English. 100 % clinic

its power (1,250mW/cm 2 ) is greatly superior to that of most other lamps and nearly as efficient as plasma lamps, with no rise of temperature;

English. 100 % clinic

Intraoral X-Ray For Film and Digital Systems

I AM CONFIDENT SOPIX SERIES TECHNICAL SPECIFICATIONS. A successful X-ray every time with minimal exposure to radiation

TECHNICAL SPECIFICATIONS

NEWTOM GO 2D GREAT.VISION

X-Ray/ Digital Imaging

2100 Intraoral X-Ray System. User s Guide

Invisible sophistication. Visible simplicity. CS Welcome to the simplicity of compact panoramic imaging

Performance Meets Simplicity

2200 Intraoral X-Ray System. User s Guide

WARNING: We recommend that you consult the Safety, Regulatory and Technical Specification User Guide before using the CS 2200.

INTRAORAL X-RAY THE INTRAORAL X-RAY UNIT FAMILY A FLEXIBLE START IN THE WORLD OF IMAGE QUALITY. SIRONA.COM

KODAK 2200 Intraoral X-ray System. User s Manual

Veterinary Digital X-Ray System Quick Start Guide

Digital Panoramic X- Ray unit. Product Data

PRODUCT CATALOGUE 20 17

OTC18 OVERHEAD TUBE CRANE SYSTEM

OPERATOR'S INSTRUCTIONS

Image Quality. HTC Grid High Transmission Cellular Grid provides higher contrast images

MILADY. Product Data. Page 1 of 8

Practix. Mobile Radiography. Constantly on the move, and yet never tired. Practix 160

Comprehensive product portfolio. FONA, the most exciting new brand in dental. ALL THE ADVANTAGES OF DIGITAL Intraoral Imaging

The intraoral X-ray family. dentsplysirona.com

Printed on: 09 Apr 2013, 07:01:56 pm; Printed by: TOBIAS BAUER

ENDOS AC / ACP User's Manual. Release 13 July 2007 (Rev. 6)

P a n o r a m i c a n d C e p h a l o m e t r i c X - r a y s

Explor-X AC / ACP. User's Manual. Release 28 April 2009 (Rev. 0)

Digitalise your Practice with Ease, Speed and Comfort. NEW from Gendex!

OPERATOR S MANUAL. Operator s manual X-Mind unity VI (15) 11/2017 NUN0EN010I

RVG 5100 and RVG User Guide

Veraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced Radiation

ALL THE ADVANTAGES OF DIGITAL Intraoral Imaging

Distributed by. Ecotron Anyview Series. The Intelligent C-Arm System

Digital Radiography System

User Manual. Version May 30, 2014 (Rev. 1)

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

ORTHOPANTOMOGRAPH OP 2D Quality and design

Corsix R 32 Accu PRODUCT DATA

Image Quality. HTC Grid High Transmission Cellular Grid provides higher contrast images

X-RAYS - NO UNAUTHORISED ENTRY

Touch the Future of Digital Panoramic Imaging. Progeny VantagE TM

ART Plus CdTe-Sensor Technology

FMT18 FLOOR MOUNTED SYSTEM

P a n o r a m i c a n d C e p h a l o m e t r i c X - r a y s

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

ECOVIEW 9 / ECOVIEW 9 PLUS Digital Radiographic System

Dental Line. Digital Panoramic System. radiology ahead

THE PANTAK THERAPAX SXT 150

SDX User Guide. Schick Technologies, Inc th Avenue Long Island City, NY (718) (718) (fax)

Digital imaging à la carte

T h e D e n t a l C o m p a n y. Vario DG. Operating Instructions. English

Maximizing clinical outcomes

MaxRay Handheld X-ray Systems Operator Training Exam

Panoura 18S. 3-In-1 Panoramic System. ImageWorks. Autofocus Imaging. Multifocal layer technology

Release 15 April 2014 (Rev. 2)

FONA XDC. Operating Instructions. English

Tomosynthesis. Energy Subtraction. Long View Imaging

Welcome to the smiling world of SOREDEX CRANEX. Novus e. Easy as a breeze. soredex.com

ADAE portable X ray machine Operation manual

CIRCLEX 0.3/0.8P324&0.6/1.2P324DK-85

make it easy, with Ray

xgenus OPERATOR S MANUAL

ELECTRONIC CONTROL CONCEPTS 160 Partition Street Saugerties, NY or local phone

Luminos RF Classic. Where value meets performance.

EXPLOR-X 70. User's manual. with AP TIME X TIME X timer (120V version) Release 16 March 2001 (Rev. 1)

Q3D. Speak to a 3D Specialist. CBCT 3D / Panoramic Imaging GENERAL DIMENSIONS. Suni Imaging Product Lines GET.

KODAK RVG 6100 and 5100 Digital Radiography Systems

Practix. Mobile Radiography. Changing its point of view comes naturally. Practix 300

Efficiency with elegance

OPERATOR S INSTRUCTIONS (for USA & Canada)

Precision Performance Power

ODYSSEY HF SERIES. ULTRA High Frequency X-Ray Technology. Precision... Performance... Power. Innovations in Digital Imaging.

CS 9300 Family User Guide Including

ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical :

BCA 9RK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode

Philips XPER FD10C R7.0.4

Small. Smart. Fast. Digital imaging plate system

RADIOGRAPHIC EXPOSURE

XRC X-Ray Calibration System

Rotating Anode X-Ray Tube Housing Assembly. General Data

RaySafe X2. Effortless measurements of X-ray

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I

Beam-Restricting Devices

Medical Imaging. Latest generation bucky room. system. radiology ahead

Planmeca ProX ENGLISH

China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R

Digital Imaging started in the 1972 with Digital subtraction angiography Clinical digital imaging was employed from the 1980 ~ 37 years ago Amount of

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

BCA 9SK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode

Ysio Max. The most direct way to the image. Answers for life.

Technical data CAMARGUE CS-VH50/300. VARIABLE Height Bucky Table With Ceiling Suspension

Radiology. Radiograph: Is the image of an object made with use of X- ray instead of light.

Protect Yourself. Electromagnetic Spectrum (Enlargement Of Ultraviolet Region)

MULTIX PRO/TOP VERTIX PRO/TOP VERTIX Solitaire X-ray systems for radiographic rooms that make life easier

Transcription:

English Where quality becomes beauty

Quality, Design, your image Because you pay more and more attention to the look and effectiveness of your practice. ACTEON SATELEC has developed X-Mind TM unity with: uncompromising design clean lines proven quality superior materials unique technological advantages

+ The perfect union X-Mind TM unity is pre-wired to allow for the integration of the SOPIX digital sensor. Therefore, you can simply connect it to your X-Mind TM unity at the time of installation or anytime in the future. SOPIX inside enables integration without any visible cables. SOPIX inside connects effortlessly to the X-Mind TM unity without technical assistance within a minute. Plug and Play!

+ Less radiation With the ACE technology, patented by SOPRO, over-exposed images are eliminated. Regardless of the amount of radiation emitted by the generator, the SOPIX sensor only uses the optimal dose required for a quality image. This technology applied to X-Mind TM unity allows the SOPIX sensor to start and stop the generator thus avoiding all risk of over exposing the image and patient as well as unnecessary re-takes of acquisitions. The patient only receives the necessary and adapted dose to his dental morphology. Traceability. % up to 52 less radiation* The dose received by the patient after each exposure appears on the timer s screen. + Brand Y X-Ray intraoral system X-Rays Exposure X-Rays Exposure Perfect image End of exposure X-Rays Overexposure End of exposure ms With SOPIX inside, this dose is also recorded in the patient s file of SOPRO Imaging ensuring permanent traceability. * Reduction variable according to the patient s morphology.

+ Work comfort Due to its ergonomically designed holder there is no danger of the sensor falling or breaking and always remains within hands reach for optimal working comfort. SOPIX inside is internally wired eliminating the need for external wiring: ease of use and aesthetics of your practice.

A sharp and contrasted image The X-Mind TM unity has a 0.4 mm focal spot. It has several configurable radiological settings: the anodic voltage (60, 65 and 70 kv) the anodic current (from 4 to 7 ma) These parameters ensure a sharp and contrasted image with defined contours. The generator focal spot Y: 0.7 mm The generator focal spot of X-Mind TM unity: 0.4 mm

Fluidity and stability You can singlehandedly position and stabilize X-Mind TM unity. Movement is fluid and is done without any effort or stress. The anti-vibration and anti-movement mechanism ensures drift free positioning during an exposure.

Ergonomic and simplistic THE «MEMORY» FUNCTION allows modifying for the pre-programmed exposure times to adapt to the specifications of your sensor or film THE EXPOSURE PARAMETERS are adjusted according to the type of tooth - (incisive, premolar, molar)

A CLEAR AND LARGE LCD SCREEN to easily see the main parameters at a distance Displays THE PARAMETERS kv, ma, type of film and ACE selection (SOPIX inside) THE DOSE IS DISPLAYED when simultaneously pressing the buttons «and +» Selection of the PATIENT MORPHOLOGY adult, child SELECTION OF THE EXAM TYPE aocclusal or inter proximal Acquiring an X-ray is done with the integrated firing switch. A remote firing switch is available as an option.

More flexibility The X-Mind TM unity can accommodate any operatory configuration. 3 arm lengths are available: 0.40 m, 0.80 m, 1.10 m and can be top or bottom mounted. With its adaptable wall plate, it is easy to replace an older generator with the X-Mind TM unity without having to do additional drilling on the wall.

- RCS Paris B 337 934 483-028765e / 80 cm / 110 cm / 31 / 43 ) 188 cm / 228 cm / 258 cm (74 / 90 / 102 ) / 80 cm / 110 cm / 31 / 43 ) / 100 cm / 130 cm 4 / 39 / 51 ) 71 cm (27 ) 81 cm (31 ) Technical specifications Classification...Class 1 type B Supply voltage...100 240 V Maximum power absorption...850 VA X-ray tube...toshiba D-041 Frequency...50/60 Hz Focal spot... 0.4 mm Total filtration...>1.5 mm Al @ 70 kv Leakage radiation... < 0,25 mgy / h Cooling duty cycle for 1 s... 32 s Technology... High frequency DC Maximum anode current...7 ma 45 cm (18 ) X-ray tube voltage... 60/65/70 kv 20 cm 23 cm (8 ) Maximum (9 ) exposure time... 2 s Compatibility... Film, phosphor plate, digital sensor 87 cm (34 ) Weight... 23 kg Configuration... Wall mounting top and bottom Timer... Microprocessor controlled 30 cm (12 ) 70 cm (27 ) 9 cm (3,5 ) 36 cm (14 ) 87 cm (34 ) 40 cm / 80 cm / 110 cm (16 / 31 / 43 ) 79 cm / 119 cm / 149 cm (31 / 46 / 59 ) 71 cm (27 ) 81 cm (31 ) 79 cm (31 ) 36 cm (14 ) 87 cm (34 ) 40 cm / 80 cm / 110 cm (16 / 31 / 43 ) 60 cm / 100 cm / 130 cm (24 / 39 / 51 ) 71 cm (27 ) 81 cm (31 ) Accessories Circular cone Ø 60 mm...20 cm (8 ) or 30 cm (12 ) Rectangular cone 45 x 36 mm... 20 cm (8 ) Arm extension... 0.40 m, 0.80 m, 1.10 m SOPIX inside/sopix² inside...size 1, size 2 Adaptable mounting wall plate Remote exposure switch 36 cm (14 ) 130 cm (51 ) 40 cm / 80 cm / 110 cm (16 / 31 / 43 ) 188 cm / 228 cm / 258 cm (74 / 90 / 102 ) 20 cm 23 cm (8 ) (9 ) 30 cm (12 ) 45 cm (18 ) 87 cm (34 ) Non contractual document - Réf. D03021 V1-02/2013 - Copyright 2013 SATELEC. All rights reserved. No information or part of this document may be reproduced or transmitted in any form without the prior permission of SATELEC. Manufactured in compliance with currently applicable regulations and standards (EC Directive 93/42/EEC and sub-segment amendment). IEC 60601-2-65 imposes for each x-ray generator furnished with a digital sensor to use a square cone. SATELEC A Company of ACTEON Group 17 av. Gustave Eiffel BP 30216 33708 MERIGNAC cedex FRANCE Tel + 33 (0) 556 340 607 Fax + 33 (0) 556 349 292 E-mail : satelec@acteongroup.com www.acteongroup.com