VERSAROC CEMENT BONDED PARTICLE BOARD ROOF SHEATHING VERSAROC CEMENT BONDED PARTICLE BOARD ROOF SHEATHING

Similar documents
Section Section Section

Installation Manual for M4-Exterior Sheathing

COMPOSITE SIDING INSTALLATION GUIDE

Installation Manual for Thermo Panel

MAXISHINGLE LAP SIDING INSTALLATION GUIDE

Inteplast Trim Free Foam

Re-Roofing Policy SPECIAL REQUIREMENTS AND NOTES

Engineered Hardwood Flooring Installation Instructions

Endura-Classic Craftsman Information

MULTISHAKE LAP SIDING INSTALLATION GUIDE STORAGE AND HANDLING: PACKAGING:

LAP SIDING INSTALLATION GUIDE

1. Section : Rough Carpentry 2. Section : Exterior Insulation and Finishing Systems 3. Section : Metal Roof Panels

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

ForceField Air & Water Barrier System. installation instructions

KuraStone TM Installation Guide

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans

LuxCore Installation Instructions

ZIP System Roof Sheathing INSTALLATION MANUAL A REVOLUTION IN ROOFING

eco-shake INSTALLATION INSTRUCTION

Installation Guide: NC 25 System

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

INSTALLATION INSTRUCTIONS

GREEN WORLD LUMBER GENUINE MAHOGANY DECKING INSTALLATION GUIDE

March High performance building boards

About Everite and Nutec 2. Nutec Bigsix Tiles : Compsition and Product Quality 4. Installation Guide 5. Support Structure 6

Description. Lesson Outcomes. Assumptions. Build a Floor. Carpenter

TRIVERSA TRIVERSA ID. Triversa Triversa ID Installation Instructions. Remove the wall base and doorway trim. Always undercut wood door casings

LAP SIDING INSTALLATION GUIDE

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

Forming and Shoring Product Selector

PAREFEU PANEL Environmentally Sustainable Product with High Fire Rating

SECTION WOOD SHINGLES

installation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

RESIDENTIAL ROOFS ADDENDUM NUMBER ONE. August 28, 2017

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

MAGNUM BOARD INTERIOR INSTALLATION GUIDELINES

B. Sequencing: Schedule installation to keep sheathing exposure to UV within the manufacturer s recommended limits.

This document is provided for guidance only, it is not intended to cover all local code variations.

The Passive Fire Protection Handbook

ENDUREED VIVA SERIES Specifications

A. Product Data: For each type of process and factory-fabricated product indicated.

THE ENGINEERED WOOD ASSOCIATION

Inspire Aledora Slate Application Guidelines

4. Metal roof jacks at penetrations and attachments


HERITAGE LAMINATED ASPHALT SHINGLES Frederick, MD

A. ASTM D Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position.

HardieTrim NT3 TM board is a decorative non-load bearing trim product. Figure 3. Fasten HardieTrim Flat Tab to minimum 7/16" OSB.

Installation Instructions for Engineered Wood Flooring

Wood structures Copyright G G Schierle, press Esc to end, for next, for previous slide 1

Installation Instructions for Viking Hearth Engineered Wood Flooring

pacific build supply ltd

Nailed Structural-Use Panel and Lumber Beams

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

DIVISION 6 WOOD AND PLASTICS

Panel Installation Instructions

INSTALLATION GUIDE NICHIPRODUCTS & NICHIFRONTIER

Product Information & Installation Instructions

Installation Instructions

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

LP SmartSide Soffit ON SITE STORAGE PREPARATION. Application Instructions Vented and Non-Vented Smooth Finish or Cedar Texture. General Information

The Passive Fire Protection Handbook

NichiProducts Installation Guidelines

Product Guide Specification

V3 Engineered Flooring- Installation Instructions

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016

LAP SIDING INSTALLATION GUIDE

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

INSTALLATION MANUAL STORAGE

HOLLOW CORRUGATED SHEETS

Customer Service: Installation, Care and Maintenance

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM

PANEL INSTALLATION GUIDE

Featuring TJ Rim Board and TimberStrand LSL

The City of Winnipeg SHINGLE ROOF REPLACEMENT Section Replacement of Shingle Roof - Louis Riel Library Page 1 of 5 Bid Opp. No.

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA

INSTALLATION INSTRUCTIONS for Vinyl Projecting Windows with Integral Nailing Fin (JII023)

Resysta 6 and 4 Flat Board Siding System Assembly Installation Guidelines

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

Mach Wall Installation Instructions

SECTION CARPENTRY

DuraLife Porch Collection Installation Instructions

FASTENERS BUILDING DEPARTMENT

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

Installation Guide. Versilux Lining INTERIORS

4) Verify that the size of the supporting member can accommodate the connector s specified fasteners.

ICC-ES Evaluation Report Reissued June 1, 2010 This report is subject to re-examination in one year.

SECTION SLATE SHINGLES. 1.1 SUMMARY A. Section Includes: 1. Slate shingles over underlayment nailed to roof sheathing.

INSTALLATION MANUAL. ZIP System Roof & Wall Sheathing FASTER. TIGHTER. ENERGY EFFICIENT.

SECTION PLASTIC FABRICATIONS PART I GENERAL 1.01 SECTION INCLUDES

The Passive Fire Protection Handbook

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

Sections & Details VOCABULARY

Hugger Installation. Roof Hugger, LLC P: P.O. Box 1027 F: Odessa, FL

ROOF-CEILING CONSTRUCTION

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

DuPont Flashing Systems Installation Guidelines. Integral Flanged Door Before water-resistive. Version 2

Transcription:

PRODUCT SUBMITTAL SHEET CEMENT BONDED PARTICLE BOARD ROOF SHEATHING A cement bonded particle board roof sheathing that can be combined with other fire resistant materials to create fire-rated roof assemblies. Strong, durable cement bonded particle board structural fire-resistant panel in standard sizes of 4 x 8 with tongue & groove edges on the long dimensions and square edges on the short dimensions. Minimum 19 mm (3/4 ) thickness for receiving nailed on roofing shingles. Versaroc roof sheathing panels may be unsealed or sealed. Versaroc panels have a maximum linear variation with change in moisture from 50% to 90% relative humidity of 0.06% tested in accordance with ASTM D1037, which means the panels will not buckle or warp like wood sheathing. Cutting of Versaroc panels requires a carbide-tipped saw blade and a circular saw equipped with dust collection or suppression to control airborne dust. Fastening is also conventional, using a screw gun and self-drilling No. 8 gauge screws. Because these panels are so durable, they may be installed in most weather conditions, including mild precipitation (rain or snow) and temperatures from 0 degrees F. Highly fire resistant. UL tested and listed for zero flame spread and zero smoke development in accordance with ASTM E84 / UL 723. Zero silica content zero asbestos content zero formaldehyde content. 100% termite & rot resistant. U.S. Architectural Products Versaroc roof sheathing is screw fastened to cold-formed steel joist or truss framing members. A fire-rated ceiling assembly is attached to the bottom of the floor joists or trusses to complete the construction. This roof system is designed to carry gravity and lateral loads. Tar paper may be stapled onto Versaroc panels using 16 gauge galvanized wide crown staples or with pneumatically operated staple guns. Roofing shingles are nailed onto Versaroc panels using pneumatically operated nail guns. Use 1-1/2 galvanized roofing nails. Follow shingle manufacturer s instructions for nailing on of the shingles. Hand nailing of roofing shingles is not recommended. Other mechanically fastened roof finishing materials such as metal roofing may be screw fastened using corrosion resistance fasteners as recommended by the roof finish manufacturer. Limitation As with all types of constructions, appropriate safety procedures must be followed to protect installers from personal injuries resulting from lifting incorrectly, falling, and eye, hand, and lung irritation from dust. Care must be taken when placing pallets of Versaroc on the roof framing. A pallet of Versaroc 19mm (3/4 ) 4 x 8 (22 panels) weighs approximately 3,600 lbs. Do not exceed roof limits of the framing system when loading pallets or panels onto the roof framing. Installation Specifications To perform in the expected manner, Versaroc roof panels must be installed according to U.S. Architectural Products specifications, using only the listed materials and components. For a complete set of specifications, see the following URL: https://www.architecturalproducts.com/wp-content/uploads/2016/08/versaroc_floor_roof_specifications.pdf

Framing The steel roof framing must be designed to meet the strength and deflection criteria specified in the contract documents. The attachment or bearing edge must be a minimum of 2 (51mm) wide with at least ¾ of the panel bearing on the supporting flange. Metal framing must be minimum of 16 gauge and spaced no greater than 24 (610mm) o.c. Follow the contract documents and the steel framing manufacturer s recommendations for the proper installation and bracing of the framing. Recommended Fastners Do not gap Versaroc panels. A recommended construction adhesive must be placed in all panel joints (both tongue & grove and square edge joints) prior to boards being tightened and screw fastened to framing. ALPHA Systems PEMCO P5100 Joint Adhesive Henkel FS-450 Joint Adhesive SikaFlex Joint Adhesive Jobsite Traffic Protection Place protective sheathing materials (i.e. plywood or additional layer of Versaroc) on the roof in high traffic areas to protect the newly installed panels.

Typical fastener layout for installation of S = Support centers not to exceed 24 inches on center. A = 16 or 24 dependant upon support spacing. B = 12 on center at panel endings over supports. C = 16 on center along supports within field of panel. D = 3/4 from panel end joint edges. E = 2 from panel side joint edges. M-P = Bond all board edges with non-flammable adhesive. Bonding of Joints in fire rated assemblies: All long dimensions of panels are tongue & groove configuration. All short dimensions of panels are square edges. Tongue & groove as well as square edged conditions both are to be bonded using PEMCO 5100 Polyurethane Adhesive or equal. Adhesive to be non-flammable, solvent free, zero V.O.C., and compatible with portland cement based products (see adhesives & bonding notes on page 5). Fastener Recommendations: Corrosion resistant screws with self-countersinking heads, such as Hilti PWH SD Cement Board Screw, No. 00372760 (#8 x 1-5/8 ) or Grabber Part No. HS8158JBWG2 (#8 x 1-5/8 ) or equal, #8 diameter minimum with self-drilling TEK point for metal framing are recommended. The length of the fastener to be selected should be 2 to 3 times the board thickness. Surface treatments being applied should always be considered when selecting the appropriate fastener types. Self countersinking head Steel Framing Wood Framing Handling & Storage Versaroc panels should be stored indoors or under protective cover from inclement weather. Store panels flat on level supports not exceeding 30 o.c. Never store panels on edges or upright. Stack full pallets no more than 4 units high. If temporarily stored outdoors, a weather protective covering must be secured over the pallets. When hand carrying single panels, the must be carried on edge with the 4 ft. dimension vertical.

Load Tables 1. Continuous loading conditions where panels span 3 or more supports of equal spacing. Uniformly distributed live loads in pounds per square foot allowable on panels. Panel Thickness PANELS SPANNING 3 OR MORE SUPPORTS Load Governed By 12 o.c. Supports 16 o.c. Supports 24 o.c. Supports 16mm (5/8 ) 212 212 117 117 50 50 19mm (3/4 ) 299 299 166 166 71 71 22mm (7/8 ) 402 402 224 224 96 96 25mm (1 ) 520 520 28mm (1-1/8 ) 654 654 365 365 158 158 32mm (1-1/4 ) 790 790 477 477 208 208 38mm (1-1/2 ) 889 889 605 605 264 264

2. Single Span Condition Uniformly distributed live loads in pounds per square foot allowable on panels. Panel Thickness PANELS SPANNING 3 OR MORE SUPPORTS Load Limited By 12 o.c. Supports 16 o.c. Supports 24 o.c. Supports 16mm (5/8 ) 169 169 93 93 39 30 19mm (3/4 ) 239 239 132 132 56 51 22mm (7/8 ) 321 321 178 178 76 76 25mm (1 ) 415 415 231 231 99 99 28mm (1-1/8 ) 521 521 32mm (1-1/4 ) 682 682 380 380 164 164 38mm (1-1/2 ) 865 865 482 482 209 209 * Load calculations based upon a safety factory of 4. Moisture content of is assumed to be 9% by weight (+-3%) as shipped from the factory - this is considered dry condition. If is allows to become saturated, reduce to live load working capacity approximately 30% until the boards have re-dried. All load table data remains valid for re-dried boards. Technical tables and specifications are provided as a general guidelines only. No table can be sufficiently comprehensive to over all details of a specific project design. We recommend that all installations be designed and reviewed by a qualified architect or engineer. Roof Finishes Follow the contract documents and the roof finish manufacturer s recommendations for the application of roof finishes. Before the application of roof finish materials, ensure that all panels are properly fastened with the fastener head driven flush or slightly below panel surface. Availability Stocking warehouses: Newark, NJ Suffolk, VA Garden City, GA Pasadena, TX Rancho Dominguez, CA Fife, WA Denver, CO

Physical / Mechanical Properties PHYSICAL PROPERTIES VALUE TEST STANDARD Thermal Conductivity (12mm / ½ ) Coefficient of Linear Thermal Expansion (12mm / ½ ) K value 1.054 BTU/hr-ft 2 - F R value 0.447 hr-ft 2 - F/BTU 0.589 x 10-5 per F 1.06 x 10-5 per C ASTM C518 ASTM D696 Density - Oven Dry 77 lbs. per cu. ft. ASTM D1037 Moisture Content 6.8% ASTM D1037 Linear Variation With Change In Moisture ASTM D1037 50% to 90% relative humidity: Parallel to fibers Perpendicular to fibers 0.06% 0.09% Saturated Thickness Swelling (24 hour 0.51% ASTM D1037 water immersion) PH Value 12 Manufacturer Water Vapor Permeance 3.93 Perm-Inches ASTM E96 6.342 US Perms Formaldehyde Content Zero EN 120 Asbestos Content Zero EN 120 Silica Content Zero EN 120 Frost Resistance No Effect - 50 cycles EN 112 Freeze / Thaw Rot & Termite Resistance Resident to destruction 100% Resistant MECHANICAL PROPERTIES VALUE TEST STANDARD Modulus of Elasticity, psi 717,800 ASTM C120 Modulus of Rupture, psi 1,840 ASTM C120 Shear Strength, psi 1,424 ASTM D732 Tensile Strength, psi 667 ASTM D1037 Compressive Strength, psi 4,852 ASTM D1037 Impact Strength, Izod Method 0.4607 ASTM D256 Permissible Design Value, psi 326 Manufacturer COMBUSTION CHARACTERISTICS VALUE TEST STANDARD Flame Spread / Smoke Development Zero/Zero ASTM E84* Fire Resistance Ratings 1 & 2 hour Floor/Ceiling Assemblies ASTM E119 Fire Resistance Ratings 1&1 ½ Hr. Rated roof assemblies ANSI/UL 263 Underwriters Laboratories tested in accordance with ASTM E84 and ANSI / UL 723 UL listed Filed # R25404 or R25239 UL Assembly BXUV.P523 acceptable alternate for roof sheathing New York City MEA Approvals: 453-04-M Versaroc accepted as a non-combustible building material. 453-04-M Versaroc 1 hour fire-rated floor assembly. 453-04-M Versaroc 2 hour fire-rated floor assembly.

Submittal Approvals Project Name: Contractor / Architect: Date: US Architectural Products, 103 Carnegie Center, Suite 320, Princeton, NJ 08540, United States 1-800-243-6677 Email: sales@architecturalproducts.com Twitter: @USAP_Build LinkedIn: www.linkedin.com/company/u.s.-architectural-products