X-RAYS - NO UNAUTHORISED ENTRY

Similar documents
China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R

Digital Imaging started in the 1972 with Digital subtraction angiography Clinical digital imaging was employed from the 1980 ~ 37 years ago Amount of

Beam-Restricting Devices

Veterinary Science Preparatory Training for the Veterinary Assistant. Floron C. Faries, Jr., DVM, MS

Technical data CAMARGUE CS-VH50/300. VARIABLE Height Bucky Table With Ceiling Suspension

RADIOGRAPHIC EXPOSURE

MXHF-1500RF is controlled by Digital key panel console that displays KV, ma and mas with APR menu programmed.

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

Nuclear Associates

Ch. 223 VETERINARY MEDICINE CHAPTER 223. VETERINARY MEDICINE GENERAL PROVISIONS X-RAYS RADIOACTIVE MATERIAL. Authority

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II

Dose Reduction and Image Preservation After the Introduction of a 0.1 mm Cu Filter into the LODOX Statscan unit above 110 kvp

X-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah

Overview of Safety Code 35

Enhanced Functionality of High-Speed Image Processing Engine SUREengine PRO. Sharpness (spatial resolution) Graininess (noise intensity)

1-1. GENERAL 1-2. DISCOVERY OF X-RAYS

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.

Nuclear Associates

Digital radiography. bucky table and wall stand as a dual detector or wireless system. Amadeo DR Systems

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

Product data Remote Controlled Table

1. Carlton, Richard R., and Arlene M. Adler. Principles of Radiographic Imaging: An Art and a Science, 5th edition (2013).

Teaching Digital Radiography and Fluoroscopic Radiation Protection

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

LECTURE 1 The Radiographic Image

Nuclear Associates , , , , , ,

RULES OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF RADIOLOGICAL HEALTH CHAPTER USE OF X-RAY APPARATUS

FMT18 FLOOR MOUNTED SYSTEM

Nuclear Associates

CR Basics and FAQ. Overview. Historical Perspective

Version 1.0. TechnicVR. Student Guide

Institutional Information:

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development

AeroDR X60. Motorized X-ray System

universal Digital Radiography (DR) System

Assessment of Beam Alignment, Collimation and Half Value Layer of Some Selected X-Ray Machines in Plateau State, Nigeria

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

Digital Radiography System

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

Maximizing clinical outcomes

Exposure System Selection

REQUIREMENTS FOR LICENCE HOLDERS WITH RESPECT TO QUALITY CONTROL TESTS FOR DIAGNOSTIC X-RAY IMAGING SYSTEMS

Minnesota Rules, Chapter 4732 X-ray Revision

Digital Radiography X-Ray System. X Twin with X Mobil Roesys GmbH [rshsmi] 1/11

C-ARM FLUOROSCOPIC AND SPOT-FILM SYSTEMS

China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW Digital RF System - HF51-5

Nuclear Associates

OTC18 OVERHEAD TUBE CRANE SYSTEM

Diagnostic X-Ray Shielding

C501-E029C. RADspeed. GENERAL RADIOGRAPHIC SYSTEM Automatic

MULTIX PRO/TOP VERTIX PRO/TOP VERTIX Solitaire X-ray systems for radiographic rooms that make life easier

Medical Imaging. Latest generation bucky room. system. radiology ahead

Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them?

Ludlum Medical Physics

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

INNOVATION BY DESIGN. Toshiba A History of Leadership REMOTE CONTROL R/F SYSTEM

QC Testing for Computed Tomography (CT) Scanner

10/26/2015. Study Harder

Key words: fluoroscopy, dose-area-product, kerma-area-product, calibration of KAP meters, patient exposure

RAD. Experiences Using the RADspeed Pro EDGE Package. 1. Hospital Description. 2. Background of Adoption. Hirohito Tanaka

Visibility of Detail

Nuclear Associates

PD233: Design of Biomedical Devices and Systems

Corsix R 32 Accu PRODUCT DATA

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

Investigation of the line-pair pattern method for evaluating mammographic focal spot performance

Test Equipment for Radiology and CT Quality Control Contents

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology

QUALITY CONTROL TESTS IN SOME DIAGNOSTIC X-RAY UNITS IN BANGLADESH

GE AMX 4+ Portable X-Ray

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

Half value layer and AEC receptor dose compliance survey in Estonia

Distributed by. Ecotron Anyview Series. The Intelligent C-Arm System

10/3/2012. Study Harder

DIAGNOSTIC ACCREDITATION PROGRAM. Radiology and CT Quality Control Procedures Workbook

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

MULTIX PRO/TOP, VERTIX Solitaire, VERTIX PRO/TOP

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

JEFFERSON COLLEGE COURSE SYLLABUS BET220 DIAGNOSTIC IMAGING. 3 Credit Hours. Prepared by: Scott Sebaugh Date: 2/20/2012

Contrast. Contrast: the difference in density on adjacent areas of a radiograph or other image receptor. Subjective. Long Scale (Low Contrast)

2012 :15th SESSION of ESMP

R&F X-ray systsem. Savings With Every Exposure

NJDEP Medical Physicist s Radiographic QC Survey Registration Number:

Visualization of sources of scattered radiation from x-ray equipment used for interventional radiology

COURSE SYLLABUS. Instructor Information. Course Description. Prerequisites/Corequisites SCANS. End-of-Course Outcomes/Objectives

Nuclear Associates

Photons interaction with matter

Overview. Professor Roentgen was a Physicist!!! The Physics of Radiation Oncology X-ray Imaging

MaxRay Handheld X-ray Systems Operator Training Exam

The Evaluation of Collimator Alignment of Diagnostic X-ray Tube Using Computed Radiography System

MILADY. Product Data. Page 1 of 8

X-RAY MEDICAL EQUIPMENT

Ultimate DR flexibility

Truly flexible to meet your clinical needs

CHAPTER 6 QC Test For Fluoroscopic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

X-ray Tube and Generator Basic principles and construction

Diagnostic Imaging Equipment & Consumables. Patient Positioning

RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT

Transcription:

Licencing of premises Premises Refer Guidelines A radiation warning sign and warning notice, X-RAYS - NO UNAUTHORISED ENTRY must be displayed at all entrances leading to the rooms where x-ray units are installed. A sign must be visible on display panels of mobile units. The sign shall be triangular in shape. Black and yellow. The minimum length for the legs of the triangle shall be 150mm. Warning lights Warning lights for General, CT & Fluoroscopy units (excluding theatres): A red warning light, which is only activated when the beam is on and when fluoroscopy is in progress, must be mounted in a conspicuous place outside the entrance to the x-ray rooms. Required warning lights must be in working order. X-ray room Refer Guideline Access doors should be of the sliding type to give better radiation protection. The doors should be lined with a lead (Pb) sheet specifically designed for the room (normally 2 mm thickness). The walls should be kiln baked solid clay brick or

lead sheet sandwiched between partitioning or brick with barium plaster (specifically designed). X-ray room continue General radiographic rooms should be approximately 16 m² There should be sufficient space for a permanently built protective cubicle. Fluoroscopic rooms should be approximately 25 m² An opening of 1.5 m is recommended at doors. The overlap of the door the slide door should be 100 mm each side Barium plaster mix: 1 part coarse barium sulphate 1 part fine barium sulphate 1 part cement Or specifically designed for the room. Walls should be protected up to a height of 2.2 m. If the x-ray room is above ground level the solid concrete slab of density 2.35 g/cm³ must be of 150 mm thickness. Thickness of ceiling slabs, if space above is occupied, should not be less than 100 mm. Windows and air conditioning units should be fixed at least 2 m above the floor. Alternatively, access near the window must be prevented effectively. Windows of upper floor x-ray rooms can be of normal height. X-ray tube Refer Guideline must have a focal spot and rotating anode Tube rating Tube filtration (to limit beam to image forming x-rays) Collimator (to restrict the beam to just the interested area)

Bucky table Floating-top table must support a patient weighing at least 110 kg, sitting in the middle of the table, without appreciable distortion. Protective cubicle A protective cubicle should be located such that unattenuated direct scatter radiation originating on the examination table or the erect Bucky do not reach the operator in the cubicle. The x-ray control for the system should be fixed within the cubicle and should be at least 1.02 m from any open edge of the cubicle wall which is nearest to the examination table The cubicle should have at least one viewing window which will be placed in such a way that the operator can view the patient during any exposure. The size of the window should be at least 30 cm x 30 cm. The minimum height of the cubicle is 2.2 meter. Should the change cubicles lead into the x-ray room the doors must be lined with a lead shield of at least 1.5 mm. Collimation Use collimation- collimate the x- ray beam to the area of interest. Collimate at least smaller than the cassette size. Collimate thus as soon as you have chosen the cassette size by using the controls. You can collimate even smaller after positioning of the patient.

Mobile used as a fixed unit Fixed C-arm (or mobile used as a fixed unit) Doors - lined with 1 mm lead sheet Walls - 115 mm brick or 1 mm lead sheet PANOREX /CEPH Dental Unit Fixed diagnostic x-ray installations Refer Guideline Direction of the primary beam is important. Alignment of tube and Bucky and appropriate grid. Additional protection can be required into walls in the direction of the primary beam- what is behind the wall if the erect Bucky is mounted? Consultation with appropriate professionals is recommended. Must consist of acceptable power rating, Exposure time, Maximum nominal electric energy, Generator control panel. Tube must have a focal spot and rotating anode Floating-top table must support a patient weighing at least 110 kg, sitting in the middle of the table, without appreciable distortion The equivalent density of the table top should be no more than 1.5 mm Al Tube assembly (U-arm) A gauge shall be installed to indicate tube assembly rotation (degrees). The X-ray tube and cassette holder shall be mounted in such a way that a recumbent

patient can also be examined with a horizontal x-ray beam. Devices shall be installed to indicate the focus-film distance (FFD) or source image receptor distance (SID). Brakes for tube assembly: Mechanical and/or electromagnetic. Grids Refer Appendix R20 GRIDS with a minimum grid ratio of 10:1 are required for a basic radiological system. The purpose of the grid is to absorb scatter x-rays. Grids with a minimum grid ratio of 10:1 are required for a basic radiological system. Usually 8:1 grids give adequate results below 90 kvp.above 90 kvp, 12:1 grids are preferred. Catheter lab Doors - lined with 2 mm lead sheet The walls should be 230 mm kiln baked solid clay brick or 2 mm lead sheet sandwiched between partitioning or 115 mm brick with 6 mm barium plaster Protective glass - The lead equivalence of the viewing window must be at least 1 mm of lead Minimise number of frames and cine runs to clinically acceptable level.

Computed tomography Doors - lined with 1.6mm lead sheet The walls should be 230 mm kiln baked solid clay brick or 1.6 mm lead sheet sandwiched between partitioning or 115 mm brick with 4 mm barium plaster Protective glass 1.5 mm lead glass (90 mm plate glass) Warning lights are required outside all entrances to CT rooms. The light must be connected to the generator in such a way that it will illuminate only during activation of the tube. CT examinations should only be carried out after a proper clinical justification by the radiologist CT Screening programmes of asymptomatic persons shall not be instituted unless approved by DOH. Screening programmes prescribed by other Governmental Acts are acceptable. Most conventional x-ray units deliver less ionizing radiation than CT systems In some cases, conventional radiography, sonography, or magnetic resonance imaging (MRI) can be just as effective as CT, and with lower radiation exposure. Optimise CT settings Based on patient weight or diameter and anatomic region of interest evaluate whether your CT operating conditions are optimally balanced between image quality and radiation exposure. CT scan is performed on a child or small adult with different technique factors. With a factor that is used for a typically sized adult, the small patient receives a significantly larger effective dose than the full-sized patient. Reduce the number of multiple scans with contrast material. Often, CT scans are done before, during, and after injection of IV contrast material. When medically appropriate, multiple exposures may be reduced by eliminating pre-contrast images. Increase table increment (axial scanning) or pitch (helical scanning). If the pitch is increased, the amount of radiation needed to cover the anatomical area of interest is decreased.