3M Dynatel. Advanced Modular System 965AMS. Future proof. testing platform

Similar documents
Dynatel Advanced Modular System 965AMS

3M Dynatel Advanced Modular System 965AMS. Now. You Know. Sold by: Toll Free: (877)

Dynatel 900 Series Subscriber Loop Test Sets

3M Dynatel Far End Device III

Far End Device II Model 1342

Specifications for 3M Dynatel 2273M/M-iD Cable/Pipe and Fault Locators

DOCUMENT OBSOLETE. Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Obsolete Document. Dynatel

HT1000/2 Series Copper Wire Analyser

T-BERD /MTS-4000 Multiple Services Test Platform Copper Services Module

MaxTester 610 KEY FEATURES AND BENEFITS THE MAXTESTER 600 SERIES SPEC SHEET SMARTER COPPER TESTING FOR INSTALLATION TECHNICIANS

Dynatel Cable/Pipe and Fault Locator 2273M Cable/Pipe, Fault and Marker Locator 2273M-iD

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.

Dynatel 965DSP / 3M Far-End-Device Setup

UAT-600 Series. amprobe.com

Dynatel 2250E/2273E Advanced Cable and Fault Locator

Firmware upgrades with new features are freely available and can be easily downloaded to the LT51 in the field.

3 Dynatel M Series Locating and Marking System DOCUMENT NEW- TO- THE- WORLD TECHNOLOGY OBSOLETE DAMAGE PREVENTION PIN- POINT ACCURACY SAFETY

3M Dynatel Triple Play Customer Service Test Set INS970

A C T Advanced Communication Tester

AXS-200/ MHz COPPER TEST SET

CopperPro Series II. The complete test set for qualifying your local loop for ADSL, VDSL and special services.

Advanced Test Equipment Rentals ATEC (2832)

SAS-562B Active Loop Antenna Operation Manual

SAS-563B Active Loop Antenna Operation Manual

3M Locating and Marking System. Identify underground assets quickly and accurately

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

AXS-200/ MHz COPPER TEST SET. part of the SharpTESTER Access Line. Telecom Test and Measurement

Wilcom MODEL T336B CIRCUIT TEST SET. Operating Instructions

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

200Amp AC Clamp Meter + NCV Model MA250

Scotchlok UR2 Connector

Opternus GmbH. optische Spleiss- und Messtechnik. Tel. +49(0) Fax +49(0)

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

User s Guide. 400A AC/DC Clamp Meter. Model MA220

APPA 300 Series. The Most User-Friendly High Performance Multimeter

AT Underground Cable/Pipe Locator System. Users Manual Mode d emploi Bedienungshandbuch Manuale d Uso Manual de uso Användarhandbok

Wilcom MODEL T136BSBZW CIRCUIT TEST SET. Operating Instructions

Portable Multi-Channel Recorder Model DAS240-BAT

Shaping the future. ... in FIELD COMMUNICATIONS

Locate Plastic. Pipe &Conduit. 3M Infrastructure Protection Division

CABLE TESTER. Models CA7024, CA7026 & CA7028. Call toll free (800) or visit

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Locate Plastic. Pipe &Conduit. 3M Electrical Markets Division

ACT6000 Advanced Communication Tester

USER'S MANUAL DMR-6700

Data Sheet: TS 54 TDR

2801 Multilock. Communications System Analyzer. Data Sheet. Boosting wireless efficiency

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Signal Integrity Test Report

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

Agilent EPM Series Power Meters

CopperPro Series II. Fluke Networks Copper Pro Series II Specs Provided by

AT Advanced Wire Tracer. Users Manual

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

DL102 Counter Loop Amplifier

Wilcom MODEL T136BGMZW CIRCUIT TEST SET. Operating Instructions

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

TLS-3A. Telephone Line Simulator. User Manual , Rev. B Covers Model TLS-3A-01

DM-45 Digital Multimeter

Using the USB Output Port to Charge a Device

EQ-AMP60 60W Mixer Amplifier

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

3 Tone Slope FINAL TEST using manual meter mode process 5 Point Test and COT Assistance

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

PV200. Why buy the PV200? The most compact I-V curve tracer around.

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

3M TM High Routability Internal MiniSAS Cable Assembly, Series 8F36

Application Series. SunSet xdsl: TDR Testing Techniques for DSL Circuits

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

PIECAL 211 Automated RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

DA6002D-DA10004D. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

Acu-Park TM. user s guide Directed Electronics, Inc. Vista, CA N9100T 09-04

712B. Users Manual. RTD Calibrator. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

DA604D DA954D DA501D DA801D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

FTB-610 Wideband Copper Test Module

MICROTOOLS MICRONETBLINK KIT

On-site multifunction calibrator

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

SAS-543 Biconical Antenna Operation Manual

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 75. Field documenting multifunction calibrator

Dynatel TM 900/900M Series Test Set

Product Data Sheet. 3M Serial Advanced Technology Attachment (SATA) Boardmount Plug, Receptacle and Cable Assemblies

vscan Data Sheet V1.0

PI-10 Broadband Power Indicator

PV210. Why buy the PV210?

Circuit Breaker Finder

JD723A/JD724B/JD726A Cable and Antenna Analyzers

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

Rock Sounders. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQRCK400 / AQRCK41

Opternus GmbH. optische Spleiss- und Messtechnik. Tel. +49(0) Fax +49(0)

cable and pipe locators RD Utility cable and pipe locator

PAMS. User s Manual. Portable Attenuation Measurement System. The solution for making easy shielding effectiveness measurements.

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

For detailed specifications and ordering info go to

Practical Instrument Electronics. PIE 311 Diagnostic RTD & Milliamp Calibrator. Best RTD & Milliamp Calibrator on the market!

Transcription:

3M Dynatel Advanced Modular System 965AMS Future proof testing platform 3

The 3M Dynatel Advanced Modular System 965ams. Whatever the technology, we ve got the tester. The new Dynatel 965AMS system contains every feature of our previous 965 model plus a larger, brighter display that features 3M Vikuiti Display Enhancement technology, a user-friendly icon-based interface and rugged field-swapable modules.* These external modules can be shared between technicians and allow transmission testing of a variety of OSP technologies. The platform is available with an optional ADSL2+ modem module, and in the future, will also feature additional modules, such as: VDSL2, FTTx fiber test, VoIP and new technologies yet to come. *Excpet for ISDN modem test 3M Dynatel Advanced Modular System 965AMS 2

Features and Benefits Communications Flexible architecture Graphical user interface Help function Backlight Vehicle power adapter Windows/CE operating system Keyboard Yellow and green LED lights Software Bright big screen Modular design Dynatel yellow Capability to work with a PC or handheld computer supporting software upload and data downloads Supports various data modem protocols such as ADSL2+ User-friendly, icon-based display of test results An internal help and tutorial provides information as needed during operation High resolution/high contrast black and white LCD display Plugs into standard vehicle accessory outlet Provides open architecture software environment Allows rapid access to twelve different "blue key" functions, reducing menu levels. Also has cursors and supports alpha-numeric entry Signal battery state and communication status TDR and autotest knowledge based systems aids technicians during test interpretation Highly visible even in bright sunlight due to proprietary 3M Vikuiti brightness enhancement technology; 80% larger than 965DSP All you need is a new module to increase test capability (no need to replace test set) Rugged, dependable The complete testing platform for all outside plant telecommunications This microcomputer-controlled flexible test set family provides full-featured testing for the triple play-voice, video and data circuits. Because it s a Dynatel 965 series tester, the AMS model is easy to use, requiring minimal training for testing professionals. And because it emphasises fault diagnosis and fault location, customer problems can be solved quickly. Autotest The knowledge-based smart autotest function is the product of more than a hundred years of Dynatel team experience. It allows an automatic test of active and inactive lines with pass/fail limits. Autotest capabilities also include expert system analysis of test results with advice on how to repair or how to locate faults. 3M Dynatel Far End Device FED II and customizable selections of tests are supported by the autotest feature of the 965AMS platform. 3

External Modules The 3M Dynatel Advanced Modular System 965AMS modules are field swappable, testing the exact digital transmission modem needed for each job. The module supports special circuits technicians who work on a variety of circuit standards during a typical day. Because the modules are field swappable, the technicians can share them. So it s no longer necessary to buy a separate testing platform for each set of modules. The ADSL2+ and VDSL2 modules are currently available. The following is a list of future modem protocols: FTTx fiber test and VoIP. Rugged, weather-resistant design The hand-held 965AMS product is housed in a lightweight, ergonomically-designed case for portability and ease of handling. The unit is weather-resistant and weighs only 5 lbs (2.2kg). The unit operates on a desktop, on the ground, up in an aerial environment and in underground locations. The Dynatel brand and the distinctive Dynatel yellow case are your assurance of rugged dependability. Accessories Product Name Test leads European test leads RFL strap AC/DC adapter Description Five 5-ft (1.5m) test leads with 2mm gold-plated banana plugs one end and chrome-plated alligator clips on other end (black/red, blue/yellow, green). Lead styles include bed of nails, no nails, spike and Canadian test leads Five 5-ft (1.5m) test leads with 2mm gold-plated banana plugs one end and 4-mm gold plated banana plugs on other end (black/red, blue/yellow, green) 1.5ft (0.5m) with alligator clips on ends 100-250 VAC (50/60 Hz) input, 12 VDC (1 A) output Power cord with IEC socket, US cord included Environmental Specifications Operating temperature 0 o to 140 o F (-18 to 60 o C) Storage temperature -40 o to 165 o F (-40 to 75 o C) Moisture: rain, water and humidity proof Meets or exceeds IP65, IP67 Physical Specifications Size (H x W x D) IN. (CM) Weight (including batteries) 965AMS (includes ADSL2+ module) 11.5 x 5.75 x 3.25 (29 x 14.5 x 8.3) 5lb (2.2Kg) 4

General Specifications Functions Range Resolution Accuracy Voltage (DC) 0 to 99.9 V 0.1 V 1% ± 0.5 V 100 to 300 V 1 V 3% Voltage (AC) Meter resistance 100k or 1m 0 to 99.9 V 100 to 250 V 0.1 V 1V 1% ± 0.5 V 3% Current Shunt resistance 0 to 59.9 ma 60 to 110 ma 430 Ω 0.1 ma 0.1 ma 1% ± 0.3 ma 2% Resistance With CO voltage 0 to 9999 Ω 0 to 9999 Ω 10 k to 99.9 kω 100 k to 999 kω 1 M to 9.9 MΩ 10 M to 99 MΩ 100 M to 990 MΩ 1 Ω 1 Ω 0.1 kω 1 kω 10 kω 10.1 MΩ 1 MΩ 1% ± 5 Ω 1% ± 50 Ω 1% 3% 3% 5% 10% Opens (no noise) 0 to 3,000ft (0 to 1,000m) 3,000 to 10,000ft (1km to 3km) 10,000 to 50,000ft (3km to 15km) 50,000 to 100,000ft (15km to 30km) 1ft (1m) 1ft (1m) 10ft (10m) 100ft (100m) 1% ± 3ft (1m) 3% 5% 10% RFL Fault range Resistance to Fault (no noise) 0 to 20 MΩ 0 to 99.99 Ω 100 to 999.9 Ω 1 k to 3 kω RTS 0.01 Ω RTS 0.1 Ω RTS 1.0 Ω 0.1% of RTS ± 0.01 Ω 1 0.2% of RTS ± 0.01 Ω 1 1.0% of RTS ± 0.01 Ω 1 Wet section test Loop resistance Resistive balance 0 to 7 kω 0 to 3.5 kω 5% Loop resistance 0 to 99.9 Ω 100 to 999.9 Ω 1000 to 7000 Ω 0.01 Ω 0.1 Ω 1 Ω 0.1% ± 0.01 Ω 0.2% ± 0.01 Ω 1.0% ± 0.01 Ω Resistance difference 0 to 99.99 Ω 0.01 Ω 1% of loop resistance ± 0.01 Ω Tone output ID tone Precision tone- 600 Ω Zout 200 to 1000 Hz, fixed level 200 to 9999 Hz, -20 to +1 dbm 10 kto 19.99 khz, -20 to +1 dbm 8 volt peak to peak 1 Hz, 0.1 db 1 Hz, 0.1 db +1 Hz 1% Hz, 0.2 db 2% Hz, 1 db Ringers 0.0 to 4.0 ringer 0 to 2000 nf 0.1 ringer 10 nf Load coil count 0 to 5 1 ±1 load coil Ground resistance 5 to 500 Ω 1 Ω 1% ± 1 Ω Ohms/distance calculator 0-9999 Ω 0-99999 ft (0-30 km) 0.01 1 ft (0.1 m) Notes: 1 All resistance to fault measurement accuracies have an added facot of (2x10-8 ) R f ohms (R f =fault resistance in ohms) 5

Electrical Specifications Functions Range Resolution Accuracy TDR Ranges 100 ft, 200 ft, 500 ft, 1,000 ft, 1 ft 2,000 ft, 5,000 ft, 10,000 ft, 20,000 ft, 30,000 ft (30 m, 60 m, 150 m, 300 m, 600 m, 1.5 km, 3km, 6 km, 10 km) 1 ft (1 m) 5 ns, 34 ns, 135 ns, 0.3% range Fixed values 1660 ns, 600 ns Velocity input 0.50 to 0.99 (150 to 299 m/μs) Modes Single trace, dual trace, differential, memory, crosstalk, peak, memory diff. Loss (and frequency) With 600 Ω Zin -40 to +10 dbm, 200 to 3000 Hz, -40 to +10 dbm, 3000 to 9995 Hz, -40 to +10 dbm, 10 k to 19.9 khz 0.1 db, 1 Hz, 0.1 db, 10 Hz 1 db, 10 Hz ±0.5 db, 2 Hz ±0.5 db, 10 Hz ±1 db, 20 Hz Noise metallic 600 Ω Zin C and psophometric 0 to 50 dbrnc (-90 to 40 dbm0p) 1 db ± 2 db Noise to ground 600 Ω Zin 40 to 100 dbrnc (-50 to 10 dbm0p) 1 db ± 2 db Longitude balance 0 to 85 db 1 db ± 2 db Dial mode DTMF, pulse Standard Standard Caller ID (U.S. and canada only) Carrier level Date, time, number, name -4 to 32 dbm 1 dbm ± 2 db Short range wideband specifications (without SA option) Wideband loss -50 to +2 dbm, 20 khz to 1.2 MHz 100, 135 Ω Zin Wideband tone output100,135 Ω Zout 0 dbm, 20 k to 2.2 MHz 0.1 db, 100 Hz 1 khz ±2 db, 1% Hz ±+1 db Short wideband specifications (with SA option) Wideband loss 100, 135 Ω Zin -85 to +5 dbm, 20 khz to 2.2 MHz 0.1 db, 100 Hz ±1 db, 1% Hz Wideband noise metallic 100, 135 Ω Zin E, F, G & G2 filters E filter 10-90 dbm F filter 20-90 dbm G filter 30-90 dbm 1 dbm 1 dbm 1 dbm ± 2 db ± 2 db ± 2 db Wideband spectral analysis 100, 135 Ω Zin Dynamic range Wideband tone output100,135 Ω Zout 10 khz to 2.2 MHz 90 dbm to +10 dbm 0 dbm, 20 khz to 2.2 MHz 0.5% of span 1 db 1 khz 1% ±1 db ±0.1% frequency ±0.5 khz Impulse noise counting E, F, G & G2 filters Counting interval 1-60 minutes 1 minute ±5% Threshold Lower limits: 30 dbrnc & E 1 DB ±1 db (typical) 40 dbrnf 50 dbrng 100 dbrn upper limit All 30 db higher for N to Ground Count capacity 9999 1 6

Electrical Specifications Functions Filters: C and Psphometric E filter F filter G filter G2 filter Range 300 Hz 3400 Hz 1 khz 50 khz 4.9 khz 245 khz 20 khz 1.1 MHz 3 db points 20 khz 2.2 MHz General Specifications Drop test Survives 3 ft (1 m) drop onto concrete, (survives 5 ft drop onto concrete with soft case) using ASTM D4169 assurance level I method 5276 Vibration Meets Mil 810F method 514.5 Water, dust and chemical proof Meets IP65 per IEC 529(1989) for rain and dust Immersion test IP67 0.15 m deep Emissions Standards meet FCC part 15, class A: Digital Devices for the US, and EN55022 (radiated emissions) Built to ISO9001/2000 certification for manufacturing facilities and TL 9000 compliant Built to ANSI/IPC A610-C manufacturing standards Language Units Battery Display Stored results (All Results) English, Spanish, and French Canadian* Feet or meters, Fahrenheit or Celsius, dbrnc or dbm0p, m/us or Vp Rechargeable battery pack or alkaline, 9 hours typical use (50% on/off measures voltage) 4.1" x 3.1"(104 x 79 mm), 320 x 240 pixel resolution, high visibility in bright sunlight due to 3MTM VikuitiTM film technology 100 results total of all types maximum Notes: Routine lab calibration is not recommended or required *Available late 2005 Features Model Name 965 Basic 965AMS TDR 965AMS TDR+SA 965AMS Basic+ADSL2+ 965AMS Basic TDR+ADSL2+ 965AMS SA+ADSL2+ Features Basic VOM & POTS TDR Short range wideband loss/tone Wideband spectrum analysis + loss/tone ADSL2+ modem 7

Features 965AMS Basic Interconnectivity RS232 USB active synch client 1.1 Battery charger port Test lead connectors Basic vom Voltage Current Resistance Soak test Opens Resistive fault location Special resistance Wet section test Ringers Ground resistance ID tone Kick test Voice band tests Load coil count Loss Noise Longitude balnace Level trace Tone Autotest Dialling Microphone and speaker capability Caler ID functionality Range All modules include Communicates with a PC using a supplied cable Includes required USB cables All modules include Detects and measures the presence of central office (exchange) or foreign DC or AC voltages, including ringer voltages Measures DC loop current with a 430-ohm shunt Measures conductor and insulation resistance up to 1GigaOhms High voltage extended period resistance measurement that will expose corrosion-induced faults Locates opens at distances up to 100,000 ft. (30 km) Displays distance to fault Measures the loop resistance and the resistance difference between two conductors on a pair Allows RFL measurement when both wires in a pair are faulted and there is no separate good pair available Measures and displays capacitance associated with one or more ringers and the equivalent count. Measures the resistance of the ground path High power interrupted signal for tracing and identification Rapid, fast combination of resistance, voltage and opens for quickly evaluating cable pairs Noise, loss, tone, longitude blance, load coil counting and FED compatibility Indicates the presence of load coils in a loop circuit and distance to the first load coil Measures voiceband loss Measures noise metallic and noise to ground in dbrnc or dbm0p Provides active measurement of line balance Measures and displays the impedance of the un-terminated line as a function of frequency Provides test tones for conductor identification and transmission testing. 10 default tones, user selectable. Voiceband to 20 khz, ID tones to 1000 Hz Supports 3M Dynatel Far End Device FED II Offhook, dialing capability, monitoring capability Speaker has 1-watt power output for noisy environments Displays number, name, date, and time just like the customers callbox 8

Features Wideband shortrange testing Test impedance Tone Wideband loss with limited range, wideband tone. This feature set is enabled in the basic and TDR units. Wideband loss measurements for short range or low frequency 135 ohms only 20kHz to 1.2MHz at OdBm Opening Features TDR Single trace Dual trace Differential Crosstalk Memory Memory diff Peak WideBand tests Full-featured TDR with user-selectable pulse widths, length, gain zoom, filter and Vp. The TDR feature is enabled in the TDR and SA models Provides graphical representation of events on a pair. Including expert system analysis of trace results Allows active comparison of two traces Displays difference between two circuits Displays the crosstalk from one pair to another Allows comparison of an active trace with a trace stored in memory Difference between memory and live trace Displays a history of maximum and minimum values with the live trace Wideband loss, wideband noise, wideband tone, Spectrum Analyzer this feature set is enabled in the SA models WideBand Continuous sine wave insertion loss and noise measurements Test impedances 100 and 135 Wideband loss Loss measurements to 2.2 MHz for pre-qualifying xdsl Tone 20kHz to 2.2 MHz at 0dBm E, F, G, G2 filter Weighted noise and impulse noise counting Ordering Information Product Number Stock Number 965AMS-TDR/SA/ADSL2+/AC/DC/BON 80-6113-1614-4 965AMS-TDR/SA/ADSL2+/AC/DC/NN 80-6113-1660-7 Key Components 965AMS Basic 965AMS Basic Description 965AMS base unit, storage bag, blue, yellow, green, red and black test leads. Conductor strap, NiMH battery pack (packed in unit), alkaline battery holder, wire gauge, self test circuit board and chain bead, 110/220V AC adapter, certificate of calibration, vehicle power adapter, instruction manual, warranty card, quick reference card, USB cable, and ethernet cable (with ADSL2 options) 9

Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty and Remedy: This product will conform to 3M published specifications and be free from defects in materials and workmanship for a period of one year from the date of purchase. In addition, 3M provides the following Conditional Lifetime Warranty for its Electronic Marker Products: When installed in accordance with 3M s installation instructions, 3M warrants 3M Electronic Markers for the lifetime of the product, to be free from defects in material and manufacture, provided the Electronic Markers are located with 3M Dynatel Test and Measurements Instruments or other brand locators as may be designated by 3M in writing. This warranty does not extend to Electronic Markers that have been subjected to misuse or improper applications or that have been repaired or altered by others. 3M MAKES NO OTHER WARRANTY INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If the Marker is found to be defective within the stated warranty period, your exclusive remedy shall be, at 3M s option, to repair or replace the Marker or refund the purchase price. 3M will not be liable to any special, incidental, or consequential damage arising from use of this 3M product, regardless of the legal theory asserted. 3 Customer Contact Centre Tel: 0870 609 4639 Please recycle. 3M 2008. All rights reserved. 10