Output Voltage nom. (adjustable)

Similar documents
Output Voltage nom. (adjustable)

Output Voltage* (nom.)(adjustable)

CB Scheme UL508 UL ATEX II3G

C B. Models. Models 2MOPP

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

Metal Case Power Supplies

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Enclosed Power Supplies

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

4.59A 2.36A 6.8A 13A 3.85W 2.85W ms 21ms. 31ms 100ms 48Vout 49ms 100ms. 240mVp-p 480mVp-p C 48Vout 480mVp-p

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

General. Environmental. EMC & Safety

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

PDAM500 Series 500W Power Supply

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

CCH400 & CCH600 Series

Features. Switching Regulator. 2.0 Amp SIP3 Single Output R-78B-2.0 R-78B DC/DC Converter

LB115S 115W Single Output

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter

CP-T range Product group picture

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms. 100mVp-p 200mVp-p 120mVp-p 240mVp-p -25 C - 70 C 48Vout 240mVp-p

Features. Regulated Converter. REM6 6 Watt 2:1 & 4:1 DIP24 Single and Dual. Output. DC/DC Converter

Load (2) Single or Dual

VOF XX - XXX - X

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

IEC/EN/UL60950 & CE certified, EN55032 Class B

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

Load (2) Single or Dual

Parameter Condition Min. Typ. Max. Internal Input Filter. refer to line derating graph on PA-4 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Switching power supplies CP range, Linear power supplies CP-L range. Content

Series AM50E-NZ 50 Watt DC-DC Converter

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

CP-T range Benefits and advantages

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

3 in 1 Dimmable (0-10Vdc, PWM signal, or resistance)

TE40 40W Single Output External Power Test & Measurement/Industrial Series

Watts HCP Series

Efficiency [%] 115VAC 230VAC. Parameter Condition Value. Line Regulation low line to high line ±0.5% max. Load Regulation 10% to 100% load ±0.5% max.

TB65 65W Single Output Test and Measurement/Industrial Series

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

Output Current 1.2VDC 1.5VDC 1.5VDC 1.2VDC 1.5VDC 1.5VDC 0.65VDC. Vout=3.6VDC 180µA. Vout=1.8VDC, use E-cap 330µF Vout=3.3VDC and 3.6VDC.

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

Features. Regulated Converter. REM10 10 Watt. 2:1 & 4:1 DIP24 Single and Dual Output REM10- / DC/DC Converter

MB120S 120W Single Output Medical Series

General. Environmental. EMC & Safety

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

TE60 60W Single Output External Power Test & Measurement/Industrial Series

300µA max at 264Vac & 63Hz (normal condition, 500µA Single Fault Condition) Adjustment Range V V. Channel

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

HEC-45LTN-45PFAS Rev A

Product Specification sheet

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

500 ma DC-DC Step Down Converter P78G-Series

CP-E range Benefits and advantages

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

LFWLP W 12V 15.00A 25.00A 92%

TE60 60W Single Output External Power Test & Measurement/Industrial Series

Type CP-S, CP-C & CP-A Switch mode

TE W Single Output External Power Test & Measurement/Industrial Series

TE90 90W Single Output External Power Test & Measurement/Industrial Series

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

LPS. TE20 15W-20W Single Output External Power Test & Measurement/Industrial Series. Features

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

High power density 3W Converter in SIP7 case. 3kVDC and 4kVDC Isolation Options

For more information, please visit the product page. output. output current max (A)

Electrical Specifications

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

Features. Regulated Converters. RS6 6 Watt. SIP8 Single and Dual Output. DC/DC Converter. Description. Selection Guide

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

Packaging. nom. Output Voltage

Ordercode Output Power Output 1 Output 2 Output 3 PCB-mounting Chassis mounting max. with solder pins with screw terminals

Pinning (3) 4:1 Input Single or Dual. Notes: Note3: /X2 is without ON/OFF CTRL and without Output Voltage Trimming

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

Power Supplies 3. SDN-C Compact DIN Rail Series

HEC-100RTA-48QSCA Rev A1.0

Power supply CP-T 48/20.0 Primary switch mode power supply

Transcription:

Industrial Power Supplies TIB Series, 80 480 W Slim profile, reduced module width Alternative side-mounting for flat panels Active Power Factor High efficiency up to 94% Back power immunity 150% peak current (4 sec.) Operating temperature range: 25 C to +70 C max. Adjustable output voltage Short circuit and overload protection OK indicator CB Scheme U508 This new DI-Rail mounting power supplies are designed for industrial applications and electric control cabinets with minimum space occupation on the DI-Rail. Most efficent circuit topology keeps the heat dissipation very low and the conversion efficiency high. The power supply can deliver high overload currents up to 4 seconds. s Order Code Output Power (max.) Output Voltage nom. (adjustable) Output Current (max.) Efficiency (typ.) TIB 080-124 80 W 24 V (23.5 28) 3.4 A 90.0 % TIB 120-124 120 W 24 V (23.5 28) 5.0 A 93.5 % TIB 240-124 240 W 24 V (23.5 28) 10 A 94.5 % TIB 480-124 480 W 24 V (23.5 28) 20 A 94.7 % http://www.tracopower.com Page 1 of 10

Input Specifications Input voltage nominal ranges 100 240 VAC effective ranges 85 264 VAC (below 90 VAC a derating of 3%/V is required) Input voltage frequency Standby power cunsumption Power Factor Correction (PFC) 45 65 Hz 80 W model: 0.9/1.3 W (115/230 VAC) 120 W model: 1.9/1.6 W (115/230 VAC) 240 W model: 1.7/1.9 W (115/230 VAC) 480 W model: 3.8/3.8 W (115/230 VAC) 80 W model: 0.48/0.48 (115/230 VAC) 120 W model: 0.97/0.8 (115/230 VAC) 240 W model: 0.98/0.92 (115/230 VAC) 480 W model: 0.99/0.97 (115/230 VAC) Harmonic limits acc. E 61000-3-2 80 W model: class A 120 480 W models: class A, B, C, D Inrush current Output Specifications Output voltage adjustment 1) 15/30 A max. (115/230 VAC) 23.5 28.0 V Regulation Input variation 0.1 % max. oad variation (10 90 %) 0.5 % max. Temperature coefficient 0.02 %/K Hold-up time 80 W model: 20/160 ms min. (115/230 VAC) 120 480 W models: 20 ms min. Start-up time Ripple and oise (20MHz bandwidth) Output overvoltage protection (OVP) 2) Power back immunity 3) 2 s max. 100 mvp-p max. 80 240 W models: 32 35 V 480 W model: 29 30 V < OVP level Operation ominal operation 100 % of Iout nom. Peak power operation 105 150 % of Iout nom. Constant current (cc) 155 % of Iout nom. Duty cycle 4) Threshold > 105 % (for peak and cc mode) CC or peak opeartion timer 4 s max. (switch off) normal operation / off period < 10 s (automatic restart after switch off or peak and cc operation timer reset) Short circuit Switch off after 4s delay, automatic restart OK signal Vout > 22.5 V typ. relay contact closed, max. 1 A, < 100mOhm OFF Vout < 21.5 V typ. relay contact open, max 30 V 1) Output voltage can be adjusted as indicated. However, output power has to be maintained at nominal value. This means the output nominal current has to be reduced in accordance with the increase of output voltage. 2) In case of an internal error a second voltage regulation loop keeps the output voltage at a save level, the power supply turns off and restarts after 10 seconds. 3) When external voltage is supplied above set output voltage and below OVP threshold, the power supply will function normally without switch off or destruction, even if external voltage is applied continuously. 4) In case of overload or short circuit, the unit switches the output voltage off after 4 seconds and tries to restart every 10 seconds. All specifications valid at nominal input voltage, full load and +25 C after warm-up time unless otherwise stated. http://www.tracopower.com Page 2 of 10

General Specifications Operating temperature Cooling Overtemperature protection Humidity (non condensing) Altitude during operation 25 C to +70 C max. derating above +60ºC : 2.0%/K convection cooling, no internal fan switch off at overtemperature 5 95 % rel. H max. 5000 m max. Isolation Voltage Input/Ouput 4250 V Input/Chassis 1500 V Ouput/Chassis 750 V Creapage Clearance Input/Ouput 8 mm Input/Chassis 4 mm Output/Chassis 1.5 mm MTBF (acc. to IEC 61709) 80 W model: > 1 950 000 h 120 W model: > 1 450 000 h 240 W model: > 1 300 000 h 480 W model: > 1 000 000 h Safety standards Information technology equipment IEC/E 60950-1, U 60950-1 CSA 22.2 o 60950-1-03 Safety low voltage switchgear and controlgear U 60947-1 (replaces U 508) Certification documents www.tracopower.com/overview/tib Electromagnetic compatibility (EMC), Emissions E 61000-6-3, E 61204-3 Conducted RI suppression on input E 55022, E 55011 class B, Radiated RI suppression E 55022, E 55011 class B, Electromagnetic compatibility (EMC), Immunity E 61000-6-2, E 61204-3 Electrostatic discharge (ESD) IEC/E 61000-4-2 4 kv/8 kv criteria A Radiated RF field immunity IEC/E 61000-4-3 10 V/m criteria A Electrical fast transient / burst immunity IEC/E 61000-4-4 2 kv criteria B Surge immunity IEC/E 61000-4-5 1 kv/2 kv criteria B Immunity to conducted RF disturbances IEC/E 61000-4-6 10 V criteria A Power frequency field immunity IEC/E 61000-4-8 30 A/m criteria A Mains voltage dips and interruptions IEC/E 61000-4-11 criteria B/C Voltage sag immunity SEMI F47 Environment Vibration acc. IEC 60068-2-6-3 3 axis, 2 g sine sweep, 10 55 Hz, 11 okt/min Shock acc. IEC 60068-2-27 3 axis, 25 g half sine, 11 ms Enclosure material Chassis aluminium Cover stainless steel Mounting DI-rail mounting for DI-rails as per E 50022-35x15/7.5 Environmental compliance Reach www.tracopower.com/products/reach-declaration.pdf RoHS RoHS directive 2011/65/EU Connection screw terminals Remote On/Off The unit can be controlled by external relay (480 W model only) contact or open collector signal. contact rating open: 15 V; leakage current max 100 µa close: 0.3 V; max drop at 15 ma signal assignement ormal operation Reserved operation 3 2 Pending 1 3 2 1 = open OFF = closed = closed OFF = open http://www.tracopower.com Page 3 of 10

Function Specification Block Diagrams Circuit block diagram for TIB 80, wide range Flyback Circuit block diagram for TIB 120 and TIB 240 http://www.tracopower.com Page 4 of 10

Function Specification (continued) Circuit block diagram for TIB 480 Output Characteristic Characteristic: Output voltage vs output current for overload conditions until switch off after 4 s at nominal input voltages http://www.tracopower.com Page 5 of 10

Output Characteristic (continued) Derating: max load vs input voltage Derating: oad vs ambient temperature http://www.tracopower.com Page 6 of 10

Outline Dimensions TIB 80: * Measurement from fron panel to DI-Rail 98,6 ±1 * 94,2 ±1 32 ±1 6,35 24 V/ 3.4 A OK 114,2 ±1 80 W TIB 080-124 100-240 VAC,50-60 Hz 2.00-0.90 A DI-Rail Hook 6,35 Alternative side mounting: 24 V/ 3.4 A OK 80 W TIB 080-124 100-240 VAC,50-60 Hz 2.00-0.90 A http://www.tracopower.com Page 7 of 10

Outline Dimensions TIB 120: * Measurement from fron panel to DI-Rail 118,6* 114,2 36 ±1 6,35 24 V/5 A OK 124,2 ±1 120 W TIB 120-124 1.50-0.78 A DI-Rail Hook 9,5 Alternative side mounting: 24 V/5 A OK 120 W TIB 120-124 1.50-0.78 A http://www.tracopower.com Page 8 of 10

Outline Dimensions TIB 240: * Measurement from fron panel to DI-Rail 118,6 ±1* 114,2 ±1 48 ±1 6,35 24 V/10 A OK 124,2 ±1 240 W TIB 240-124 2.89-1.27 A DI-Rail Hook 9,5 Alternative side mounting: 24 V/10 A OK 240 W TIB 240-124 2.89-1.27 A http://www.tracopower.com Page 9 of 10

Outline Dimensions TIB 480: * Measurement from fron panel to DI-Rail 118,6 ±1* 114,2 ±1 82 ±1 6,35 24 V/20 A 124,2 ±1 480 W TIB 480-124 OK Remote /OFF 2.89-1.27 A GD DI-Rail Hook M2 3,5 9,5 Alternative side mounting: 24 V/20 A 480 W TIB 480-124 Remote OK /OFF GD 2.89-1.27 A Copyright 2016 Traco Electronic AG Specifications can be changed without notice! www.tracopower.com Rev. ovember 11. 2016 Page 10 of 10